TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

Similar documents
CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Contact person Date Reference Page Richard Johansson P (2) Fire Research

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test Report: ICL/CR15/11/087

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

Certifikat och provningsprotokoll för art och 4511

Classification report

Additional Reaction to Fire Classification Report

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

TFI Report Classification

Reaction to fire classification report No C-rev.1

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

2005-CVB-R0192 Onderzoek naar de mogelijke invloed van FirePro aërosol op in werking zijnde computerapparatuur

Additional reaction to fire classification report No H

CLASSIFICATION REPORT

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66

Reaction to fire classification report No C

CLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN :2007

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

Classification Report

BS EN ISO : 2010

Centrum stavebního inženýrství a.s.

BS EN ISO : 2010

P.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands

Form: KSD-100:10 Page 1 of 3

Analysis Report

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC)

REVIEW ON TWO PERFORMANCE-BASED TESTS FOR ASSESSING FLAME SPREAD IN HONG KONG

Analysis Report

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

TFI Report Reaction to fire test

Test Report: ICL/H18/9039 Rev 1

Technical Sheet. Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

Sýnishorn Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

TFI Report Classification

MFPA Leipzig GmbH Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme

BS EN ISO : 2010

BS 476: Part 6: 1989+A1:2009

IMO Resolution MSC 61(67): Annex 1: Part 2

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

DELTA Classification Report

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Vescom bv Sint-Jozefstraat AV Deurne Nederland

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

MEDIUM-DENSITY HOUSING # 7. Fire safety

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

Not all insulation is the same! from fire testing to real fires.

Facts about insulation and fires 29 October 2014

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

BS 476: Part 6: 1989+A1:2009

New European Fire Testing Classification for Construction Products

Review Fire Test Report

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CERTIFICATE OF APPROVAL No ME 5085

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

BCTC CARPET TECHNICAL CENTRE

New European Cable Testing and Classification

FUNDERMAX GMBH FIRE TEST REPORT

CPR: EUROCLASSIFICATION & TESTS FOR CABLES

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

2 Examination of Cladding Panels (Laboratory)

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

Report VNLF Test Report

CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

SUBJECT: ASSESSMENT FOR INTERNAL SURFACE FINISHES OF LIGHTBETON PANEL FOR COMPLIANCE WITH THE NEW ZEALAND BUILDING CODE(NZBC)

Development of a Test Procedure for Sandwich Panels using ISO 9705 Philosophy

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

BS EN : 2001 & IEC :2000

Loss Prevention Standard

Analysis Report

NF X : Parts 1, 2, 3, 4 & 5

Classification of Fire Performance of Wall and Ceiling Lining Materials

Test Report No: ICL/H17/7967

Circular Fire Damper Cartridge

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

Information Data Sheet. Fire behavior of decorative high pressure laminates (HPL)

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

Transcription:

ederlandse Organisatie voor toegepast-natuurwetenschappelijk onderzoek / etherlands Organisation for Applied Scientific Research TO report Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box 49 26 AA Delft www.tno.nl E 13823:22 "Single Burning Item" and E 11925-2:22 "Ignitability" test report of examination on the reaction to fire performance of EVIROGRAF PRODUCT 42: Intumescent paint and Varnish on PU foam substrate manufactured by ORAC Belgium T +31 15 276 3 F +31 15 276 3 25 Date January 26 Author(s) F. Paap W. Langstraat umber of pages 11 (including graphs and pictures) Sponsor Envirograf House, Barfrestone DOVER, Kent CT15 7JG United Kingdom Project name Reaction to Fire Project number 6.55494/1.1 All rights reserved. o part of this publication may be reproduced and/or published by print, photoprint, microfilm or any other means without the previous written consent of TO. In case this report was drafted on instructions, the rights and obligations of contracting parties are subject to either the Standard Conditions for Research Instructions given to TO, or the relevant agreement concluded between the contracting parties. Submitting the report for inspection to parties who have a direct interest is permitted. 26 TO

TO report 2 / 1 Products: Product 42-1 intumescent coating Purpose of test: Examination of Product 42-1 intumescent coating on a rigid polyurethane foam substrate on reaction to fire performance and smoke production in accordance with E 13823: 22 Single Burning Item (SBI). Contractor, manufacturer and production site: Envirograf House, Barfrestone DOVER, Kent CT15 7JG United Kingdom Dates of examination: January 1 and 11, 26 Period of report issue and report number: 26; 26-CVB-R????. Product description: The product 42-1 is an intumescent coating system, to be applied to a substrate. The test specimen were constructed as follows: - 9.mm WBP plywood, density between 6 to 65 kg/m 3. - 12.5mm S/E gypsum plasterboard. - Polyurethane K24 material, approximately 9.mm thick, non Fire rated, density 4 kg/m 3. - Paint system is one coat of HW1 White or Coloured intumescent water based coating applied at 8-1m² per litre per coat. Mounting configuration: The mounting of the panels was in accordance with the prescriptions in the SBI standard E 13823:22. The panels were mounted directly onto a CaSi backing board In the long wing of the specimens a vertical joint was positioned at 2 mm distance, and a horizontal joint at 5 mm. Samples: Sampling procedure: by contractor Age: At time of examination: PU foam substrate four/six months, Envirograf product 42 coating applied eight weeks prior to test date. Date of receipt: 23 ovember 25 Examination: A total of three SBI test were carried out.

TO report 3 / 11 Table 1: SBI classification parameter results. Product ref. and test no. Values used for Classification FIGRA.2MJ [W/s] Heat production / flame spread Smoke production Flaming debris FIGRA.4MJ [W/s] THR 6s [MJ] LFS edge {Y/} SMOGRA [m 2 /s 2 ] TSP 6s [m 2 ] FDP f 1s {Y/} FDP f >1s {Y/} 28 128 8.6 75 151 276 157 8.4 86 169 21 126 7.7 9 15 231 137 8.2 84 157 Observations during the tests: In the second test, not all checks were OK due to a too high difference between duct and ambient temperature, 4.1 K where 4 K is allowed. In the third test, not all checks were Ok due to a (marginally) too high volume flow in the first part of the test sequence (first 2 minutes). In the opinion of TO Centre for Fire Research this will not have influenced the classification parameter results significantly. Ignitability following E 11925-2:22 The results are given in Table 2. Table 2: Ignitability classification parameter results, ignition time 3 s sample Ignition of sample Maximum flame height t 15 Afterburning time Ignition of filter paper [Y/] [mm] [s] [s] Y/ Edge ignition 1 2 3 4 5 6 48 49 53 52 52 41 not reached Value used for classification 49 surface ignition 1 2 3 4 5 6 6 51 52 51 65 64 not reached Value used for classification 57

TO report 4 / 11 Observations of physical behaviour of the test specimen: the material did not shrink and melt away from the flame without ignition. Applying the testing protocol as specified in Annex A of the standard was therefore deemed not necessary. Conclusions/Remarks: 1. A formal classification is to be assessed in accordance with the E 1351-1, Classification using fire reaction tests. 2. The field of application of the test results is limited to the end use applications in accordance with the mounting and fixing used in the test. 3. Graphs of rate of heat release HRR av (t), total heat release THR(t), 1 HRR av (t)/(t 3), rate of smoke production SPR av (t), total smoke production TSP(t) and 1 SPR av (t)/(t-3), are presented hereafter. 4. The test results relate to the behaviour of the test specimens of a material under the particular conditions of the test; they are not intended to be the sole criterion for assessing the potential fire hazard of the material in use. 5. Regarding the precision of the test method, the following information is given in the Annex B of the E 13823: Table B.2 Average relative standard deviations FIGRA,2MJ FIGRA,4MJ THR6s SMOGRA TSP6s Average ( sr /m) 14 % 15 % 11 % 15 % 18 % Following Annex B of E 11925-2 the absolute repeatability/reproducibility for this test method is within 3 s to 5 s. W. Langstraat F. Paap Ph.D.

TO report 5 / 11

TO report 6 / 11

TO report 7 / 11

TO report 8 / 11

TO report 9 / 11

TO report 1 / 11

TO report 11 / 11 Pictures of test specimen before and after the test.