Corning LSE Digital Dry Bath Heater

Similar documents
Corning LSE 6L Digital Water Bath

Digital Heat Block User Manual

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Corning LSE Benchtop Shaking Incubator

MD-MINI Dry Bath. Instruction Manual

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

Operator s Manual. Histology Bath

Dry Bath Heating Systems

Reacti-Therm I and III Heating Modules

Instruction Manual for the Revolutionary Science RS-PB-200 Dual Poly Pro Bath

Operation Manual Vortex mixer unitexer 1

Note To The User: This product has updated features not yet mentioned in the product manual.

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Reacti-Therm I and III Heating/Stirring Modules

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge

Whynter Portable Ice Maker 33 lb capacity - White

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Operator s Manual. IP-100 Immersion Probe Cooler

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

Revolutionary Science RS-IF-202

Instruction Manual for the Revolutionary Science RS-PB-100 Poly Pro Bath TABLE OF CONTENTS

62 MAX/62 MAX + Infrared Thermometer

Operator s Manual. The Quietek

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Towel Warmer. Luxurious warmth for towels, robes and blankets

POWERSHRED OPERATING INSTRUCTIONS NOTICE D'UTILISATION MANUAL DEL PROPIETARIO BETRIEBSANLEITUNG 420 C C C-420C 420-2HS C-420HS

Fellowes 4200SC/ 4200CC/C-420HS Paper Shredder

POWERSHRED OPERATING INSTRUCTIONS NOTICE D'UTILISATION MANUAL DEL PROPIETARIO BETRIEBSANLEITUNG C 480-2HS

Projection Alarm Clock USER GUIDE

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

Environmental Monitoring SmartSlot Card

POWERSHRED C OPERATING INSTRUCTIONS NOTICE D'UTILISATION MANUAL DEL PROPIETARIO BETRIEBSANLEITUNG

MT4 MAX/MT4 MAX + Infrared Thermometer

Instruction Manual and Warranty

Portable Heated Black Glass Shelves

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

TTT Digital Incubator

IMPORTANT SAFETY INFORMATION:

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Owner & Operator s Manual. Table of Contents

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

AH-470. Flat Panel Micathermic Space Heater OWNERS MANUAL. Read and save these instructions.

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

Precision Infrared Thermometer. Users Manual

Infrared Thermometer

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Infrared Thermometer. Getting Started

Towel Warmer MAKE EVERYDAY A SPA DAY

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

USER GUIDE. Metal Ceramic Heater NS-HTMCSL6. Before using your new product, please read these instructions to prevent any damage.

700G Series. Pressure Gauge. Safety Information

PROCESSING UNIT II V Hz V Hz. Table of Contents

- Oscillating Table Model Fan

62 MAX/62 MAX + Infrared Thermometer

SAFEVIEW-MINI2 TRANSILLUMINATOR

HC12W COOL MIST ULTRASONIC HUMIDIFIER OWNER S MANUAL. Read and save these instructions.

WA A Aqua Sub Bottom-load Water Cooler

Stand Fan. English. Owner s Guide. Model F R

Users Manual. Air Velocity Meter

CABINET INFRARED HEATER

OPERATION, SERVICE & PARTS MANUAL

Canister Vacuum. OWNER S MANUAL Models CV520HB/HR/HY 120V., 60Hz., 10 Amps

Operators Manual. Microprocessor Controlled. Water Baths

WHYNTER PORTABLE ICE MAKER 49 LB CAPACITY - STAINLESS STEEL

555 Hotplate 565 Magnetic Stirrer 575 Hotplate-Stirrer

Pasto Sous vide water bath

FEATHERWEIGHT PRO USER GUIDE 1703 SERIES

INSTALLATION AND USER INSTRUCTION GUIDE. Electric Fire With Remote Control. Model: WM-3522CF. Please read all instructions carefully and

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

Cavitator Ultrasonic Cleaner Instruction Manual

IMPORTANT SAFETY INFORMATION:

Power Conditioners User s Manual. For use with Standard Power Conditioners, Medical Power Conditioners and Ground Guard Power Conditioners

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Performance Thermal Binder

Alen A350 HEPA Air Purifier USER MANUAL

Model OEM-2 INSTRUCTIONS FOR USE

User s Guide for the SunDanzer BFRV55

Shaking Hot Tubs. Orbital / Reciprocating Shaking Water Bath Liter 115V S 28 Liter 115V Liter 230V

IMPORTANT SAFETY INFORMATION:

Operators Manual. Microprocessor Controlled. Water Baths

Refrigerated Incubator Model and Operating Instructions

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

HIn3550 Magnetic Field Monitor User's Manual

IMPORTANT SAFETY INFORMATION:

USER GUIDE DEEP FRYER WITH OIL FILTRATION SYSTEM

T100 Air Purifier USER MANUAL

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

CALIBRATABLE 3-FUNCTION THERMO- HYGROMETER USER S MANUAL

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

BLT-999W-2 Item # 60757

150 SERIES VACUUM SEALING SYSTEM

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

All about the Use &Care

Transcription:

Corning LSE Digital Dry Bath Heater Instruction Manual Model Nos. 6875-SB, 6885-DB, 6895-FB 6876-SB, 6886-DB, 6896-FB 6877-SB, 6887-DB, 6897-FB 6878-SB, 6888-DB, 6898-FB About This Manual This manual is designed to assist you in the optimal usage of your Corning LSE Digital Dry Bath Heater. The manual is available in English, French, German, Italian, Portuguese, and Spanish at www.corning.com/lifesciences.

Corning LSE Digital Dry Bath Heaters Single-, Dual-, and Four-block models

Instruction Manual Corning LSE Digital Dry Bath Heater Table of Contents 1.0 General Specifications... 2 2.0 Safety Precautions... 2 3.0 Installation... 3 4.0 Controls... 3 5.0 Operation... 4 6.0 Calibration... 4 7.0 USB Interface... 5 8.0 Troubleshooting Guide... 6 9.0 Service and Repair Information... 6 10.0 Cleaning and Maintenance... 7 11.0 Equipment Disposal European Regulations... 7 12.0 Appendix: Symbols and Conventions... 7 13.0 Limited Warranty... 8 Intended Use Corning LSE Digital Dry Bath Heaters provide comprehensive designs for a wide variety of life science research applications. Excellent temperature control figures can deliver accurate and reliable experimental results from one experiment to another. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 1

1.0 General Specifications Temperature range Ambient +5 C to 150 C Temperature display resolution Temperature uniformity Temperature accuracy Temperature controller Timer Operating altitude Control I/O 0.1 C 4 digit LED ±0.2 C (at 37 C in block) ±0.3 C Microprocessor user calibratable 1 to 99 hours 59 minutes or continuous in 1 minute increments Not to exceed 2,000 meters PI Microprocessor controller USB unidirectional Dimensions Single and dual block models: (W x D x H) 8.3 x 12.4 x 4.7 in. (21 x29 x 12 cm) Four block models: 8.3 x 16.3 x 4.7 in. (21 x 39 x 12 cm) Weight Electrical requirements 2.0 Safety Precautions Single and dual block models: 7.0 lbs. (3.2 kg) Four block models: 9.6 lbs. (4.4 kg) 6875-SB: 115V, 50/60Hz, 1 A, fuse 1.6 AT 6876-SB: 230V, 50/60Hz, 0.5 A, fuse 1AT 6877-SB: 230V, 50/60Hz, 0.5 A, fuse 1AT (UK plug) 6878-SB: 100V, 50/60Hz, 1 A, fuse 1.6 AT 6885-DB: 115V, 50/60Hz, 1.9A, fuse 3.15AT 6886-DB: 230V, 50/60Hz, 0.95 A, fuse 1.6AT 6887-DB: 230V, 50/60Hz, 0.95 A, fuse 1.6AT (UK plug) 6888-DB: 100V, 50/60Hz, 1.9A, fuse 3.15AT 6895-FB: 115V, 50/60Hz, 3.73 A, fuse 5 AT 6896-FB: 230V, 50/60Hz, 1.86 A, fuse 3.15 AT 6897-FB: 230V, 50/60Hz, 1.86 A, fuse 3.15 (UK plug) 6898-FB: 100V, 50/60Hz, 3.73 A, fuse 5 AT Do not use this product in an explosive environment. Do not use in the presence of flammable or combustible material. Do not heat substances that react violently when heated. Do not touch block when hot or when unit is heating. Use block lifter. Do not touch area around block or block well when unit is hot. Do not spill liquids into the well area or into the unit side vent holes. Connect unit only to a properly grounded outlet. 2

Caution: HOT surfaces that can burn or cause injury. Use of this product in any manner not specified by the manufacturer or modification of the product may cause injury and/or may void the warranty. 3.0 Installation Upon unpacking the Corning LSE Digital Dry Bath Heater, inspect for damage. Shipping damage is the responsibility of the carrier. Inspect that the following are present: instruction manual, data logger software, line cord, block lifter, lid, USB cable. Select a location that is dry and not subject to drafts or moving air from heating or air conditioning vents or air blown by other equipment. Place the unit on a flat, preferably non-flammable, surface. Allow sufficient room around the unit for access and cooling (six inches minimum on all sides is suggested). Plug the unit into a properly grounded outlet. Using the lifter, insert the block(s) into the well. The unit is now ready for use. 4.0 Controls On/Off rocker switch, located on the back of the unit: Turns primary power on and off. Start/Stop LED, red: Used to activate or stop the unit. Illuminates when unit is in heating mode; off in temperature set mode. Time LED, green: Used to set or select Time mode. This LED light indicates running Time mode. Heating LED, red: Illuminates when unit is in Heating mode and unit is applying heat to the block. This LED is on continuously during heat-up and cycles on and off when the unit is at the set temperature. Temperature Up arrow key: Raises set temperature when unit is in Set mode. Temperature Down arrow key: Lowers set temperature when unit is in Set mode Timer Up arrow key: Raises set time when unit is in Set mode. Timer Down arrow key: Lowers set time when unit is in Set mode. 3

5.0 Operation 1. Place the Corning LSE Digital Dry Bath Heater on a sturdy and level surface in a safe, dry place away from laboratory traffic. 2. Ensure the AC power switch is Off, then plug the three-pronged power cord into a grounded three-prong AC outlet of the appropriate voltage (115V or 220V as indicated on the rating sticker near the AC cord on the back of the unit). 3. Select suitable module block(s) or appropriate water volume and put the block(s) into the Corning LSE Digital Dry Bath Heater. 4. Turn the AC power On. 5. Run temperature calibration procedure when using the instrument for the first time. 6. Press the Temperature Up or Down keys to adjust to the desired temperature. 7. Press the Timer Up or Down keys to adjust to the desired time. 8. Press the Start/Stop key to start heating. 9. If you need to reset the timer during heating, press the Start/Stop key to deactivate heating. 10. Press the Start/Stop key again to stop the unit. 11. If the lid is to be used, align the shaded area on the dry bath surface with the magnet of the lid to attach it to the housing. To remove the lid, press one hand firmly on the housing and use the other hand to pull the lid off. To use the lid, the tube should not exceed 25 mm above the heating block. 6.0 Calibration Calibration allows the unit temperature display to be adjusted or matched to the temperature of a single sample or to a calibrated thermometer, thereby making an independent temperature measure of the block. Corning LSE Digital Dry Bath Heaters are calibrated at the factory at 40 C using a standard small hole-pattern block. If you are using a block with a high heat loss rate, such as a block with large holes or a platform style block, you may choose to recalibrate the unit to your specific application. 4

Also, if you are using very loose or odd shaped vessels, the calibration function can help you match the display temperature to your actual sample temperature. To calibrate the unit for a given block or sample, first turn the unit off using the On/Off switch. Then place a thermometer of known accuracy* into the block thermometer hole or a thermocouple or other sensor into your sample. Make sure there is a good fit between the thermometer and the block or good contact between any sensor and sample or sensor and block. To calibrate the block or sample to the display: 1. Press and hold the Start/Stop key, then simultaneously power up the unit with the On/Off switch. 2. You should hear a DU-DU-DU sound from the dry bath and the display will have one segment flashing on the left and will show a set temperature, and the right will show adjt. 3. Use the Temperature Up and Down arrow keys to set the desired temperature at which you want to calibrate the unit. Then press the Start key. 4. Allow a minimum of 10 minutes (maximum 20 minutes) for the unit to heat up to your set temperature and to equilibrate at this temperature. The entire LED display will start flashing when equilibration is reached. 5. After the entire display has started flashing, read the thermometer (or sensor meter) and use the Up and Down arrow keys to adjust the display to the thermometer or sensor reading. Then press the Start/Stop key. 6. The unit will then begin to automatically adjust its operating temperature to your original set point with the recalibration factor included. Allow sufficient time for the unit to re-equilibrate, then compare the thermometer or sensor reading to the calibrated display again. They should closely match. If not, repeat the calibration procedure. 7.0 USB Interface Corning LSE Digital Dry Bath Heaters have a USB unidirectional data port. A cable and software are available which allow a user to use a desktop or laptop computer to record and/or print a record of the temperature profile produced by the dry bath. *Thermometers used for calibration purposes should have a written calibration certificate and be traceable back to NIST or other certified body. General lab thermometers are often not accurate enough for calibration work. 5

8.0 Troubleshooting Guide Problem Display/LEDs do not light up Unit not heating Unit display overshoots Block or sample temperature not the same as display temperature Solution 1. Check power cord and outlet. 2. Check On/Off switch. 3. Check fuse. 4. Contact Corning Life Sciences for service. 1. Is set point below room temperature? 2. Is Start LED illuminated? 3. Press Start key. 4. Contact Corning Life Sciences for service. 1. Normal operation. Display set point in heat-up overshoots on initial heat-up but block and sample do not overshoot (see Operation section). 1. Is unit in heating mode? 2. Is unit sitting in a drafty area? 3. Check accuracy of thermometer. 4. Is thermometer making good contact? 5. Follow calibration procedure. 9.0 Service and Repair Information If you have a question about the Corning LSE Digital Dry Bath Heater or have a service inquiry, contact Corning Customer Service immediately at: 1.800.492.1110 (for toll-free calling within the U.S. and Canada) 1.978.442.2200 (outside the U.S.), or Contact your local Corning support office listed in the back of this manual. Before returning any unit for service, a Return Authorization (RA) number must first be obtained. Equipment sent in without prior authorization will be returned at the customer s expense. When returning a unit to Corning for service, it should be sent in the original packaging. If this is not possible, be sure that the unit is sufficiently packed. Any damage resulting from improper packaging is the responsibility of the customer. A written explanation should accompany the unit along with the RA number. 6

10.0 Cleaning and Maintenance Make sure that the Corning LSE Digital Dry Bath Heater and block are cool and the power cord is disconnected before performing any cleaning or maintenance. Repair or maintenance should only be performed by an authorized service technician. The dry bath may be cleaned with a moist cloth containing a mild soap solution. Do not immerse the dry bath in water or any liquid. The blocks may also be cleaned in a mild soapy solution. Be sure that all items have thoroughly dried before attempting to connect the cord or use the unit. Spills: In the event liquid is accidentally spilled into the bath or well area, disconnect the plug from the outlet and turn the unit upside down to minimize liquid contact with the internal components. Remove the bottom cover and inspect to assure liquid has not contacted heater elements, electronic controls, or connectors. Have a qualified service technician clean the unit and replace any damaged parts. 11.0 Equipment Disposal European Regulations According to Directive 2012/19/EU of the European Parliament and of the Council of 4 July 2012 on waste electrical and electronic equipment (WEEE), the Corning LSE Digital Dry Bath Heater is marked with the crossed-out wheeled bin and must not be disposed of with domestic waste. Consequently, the buyer shall follow the instructions for reuse and recycling of waste electronic and electrical equipment (WEEE) provided with the products and available at the following link: www.corning.com/weee 12.0 Appendix: Symbols and Conventions The following chart is an illustrated glossary of the symbols that may be used in this manual or on the product. CAUTION: This symbol refers you to important operating and maintenance (servicing) instructions within the product Instruction Manual. Failure to heed this information may present a risk of damage or injury to persons or equipment. ATTENTION: Hot Surface. Indicates disposal instruction. DO NOT throw this unit into a municipal trash bin when this unit has reached the end of its lifetime. To ensure utmost protection of the global environment and minimize pollution, please recycle this unit. 7

13.0 Limited Warranty Corning Incorporated (Corning) warrants that this product will be free from defects in material and workmanship for a period of three (3) years from date of purchase. This warranty is valid only if the product is used for its intended purpose and within the guidelines specified in the supplied instruction manual. Should this product require service, contact Corning Customer Service department at 1.800.492.1110 or 978.492.1110 to receive a return authorization number and shipping instructions. Products received without proper authorization will be returned. All items returned for service should be sent postage prepaid in the original packaging or other suitable carton, and padded to avoid damage. Corning will not be responsible for damage incurred by improper packaging. Corning may elect for onsite service for larger equipment. This warranty does not cover damage caused by accident, neglect, misuse, improper service, natural forces, or other causes not arising from defects in original material or workmanship. This warranty does not cover motor brushes, fuses, light bulbs, batteries, or damage to paint or finish. Claims for transit damage should be filed with the transportation carrier. ALL WARRANTIES INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION OF 36 MONTHS FROM THE ORIGINAL DATE OF PURCHASE. CORNING S SOLE OBLIGATION UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT, AT CORNING S DISCRETION, OF A DEFECTIVE PRODUCT. CORNING IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGE, COMMERCIAL LOSS, OR ANY OTHER DAMAGES RESULTING FROM THE USE OF THIS PRODUCT. Some states do not allow limitation on the length of implied warranties or the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights. You may have other rights which vary from state to state. No individual may accept for, or on behalf of Corning, any other obligation of liability, or extend the period of this warranty. For your reference, make a note of the model and serial number, date of purchase, and supplier here. Model No. Serial No. Date Purchased Supplier 8

Notes 9

Register your product warranty online at www.corning.com/lifesciences/warranty. For more specific information on claims, visit the Certificates page at www.corning.com/lifesciences. Warranty/Disclaimer: Unless otherwise specified, all products are for research use only. Not intended for use in diagnostic or therapeutic procedures. Corning Life Sciences makes no claims regarding the performance of these products for clinical or diagnostic applications. For additional product or technical information, visit www.corning.com/lifesciences or call 800.492.1110. Outside the United States, call +1.978.442.2200 or contact your local Corning sales office. Corning Incorporated Life Sciences 836 North St. Building 300, Suite 3401 Tewksbury, MA 01876 t 800.492.1110 t 978.442.2200 f 978.442.2476 www.corning.com/lifesciences For a listing of trademarks, visit www.corning.com/clstrademarks. All other trademarks are the property of their respective owners. 10 Worldwide Support Offices ASIA/PACIFIC Australia/New Zealand t 61 427286832 China t 86 21 3338 4338 f 86 21 3338 4300 India t 91 124 4604000 f 91 124 4604099 Japan t 81 3-3586 1996 f 81 3-3586 1291 Korea t 82 2-796-9500 f 82 2-796-9300 Singapore t 65 6572-9740 f 65 6861-2913 Taiwan t 886 2-2716-0338 f 886 2-2516-7500 EUROPE France t 0800 916 882 f 0800 918 636 Germany t 0800 101 1153 f 0800 101 2427 The Netherlands t 020 655 79 28 f 020 659 76 73 United Kingdom t 0800 376 8660 f 0800 279 1117 All Other European Countries t 31 (0) 20 659 60 51 f 31 (0) 20 659 76 73 LATIN AMERICA grupola@corning.com Brasil t (55-11) 3089-7400 Mexico t (52-81) 8158-8400 2017 Corning Incorporated. All rights reserved. Printed in Mexico 2/17 CLS-EQ-121/LN207000