Product Specifications 4 Breaker Main Disconnect Panel with Undervoltage Trip

Similar documents
Product Specifications 3 Breaker Main Disconnect Panel with Undervoltage Trip

Product Specifications Fail Safe Emergency Power Off Control Panel 480V 3 Phase

Product Specifications 480 VAC, 175A Main Power Distribution Panel

Product Specifications Warning Light Control Cabinet

Product Specifications 480 VAC, 70A Main Power Distribution Panel

Product Specifications Warning Light Control Cabinet

Product Specifications Auto Restart Main Power Distribution Panel

Product Specifications Linear Accelerator Relay Junction Box

Product Specifications MaxLumen MRI LED Diffused Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

MaxLite LED High Bay Fixtures

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

MaxLite Polygon Linear LED Light

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

Installation, Operation & Service Manual

Guide Specification Model CTG Automatic Transfer Switch

Panel Mounted Heat Exchangers by Dantherm, Inc.

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

GETZ MANUFACTURING PART # CYLINDER DRYER

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

INSTALLER S & OWNER S MANUAL

Quest Power Electric Heat EHS 31 Pro

Elevator Control ES Switch

Owner s Manual Phoenix FireBird

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

A PROUD HERITAGE OF EXPERIENCE & QUALITY. Beverage Cooler VT-SC-1

Quest Power Electric Heat EHS 62 Pro

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

For use with models: BP , BP , BP

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. MARCH 2011 version 7

INSTALLATION INSTRUCTIONS

MaxLite LED Round Pendant Highbay Series

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

VT SERIES VERTICAL TOASTER OPERATOR S MANUAL TABLE OF CONTENTS

INSTALLER S & OWNER S MANUAL

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

SECTION AUTOMATIC TRANSFER SWITCHES

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

SC Installation, Operation & Application Guide

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Owner s Manual Phoenix Aquadry TX 200

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

PowerWave 2 Busway System

Instruction Manual and Warranty

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Installation and Operations Manual

Installation & Maintenance Instructions

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Quest PowerHeat HFC 100 Pro

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

INSTALLATION, OPERATION AND MAINTENANCE

Desiccant / Pump Dehumidification System. Model Operating Manual

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

Phoenix AirMAX - Radial Air Mover

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Installation Instructions

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

SC Installation, Operation & Application Guide

IW-25-2 Dehumidifier Installation & Operations. Manual

Quest Dry 105, 155, and 205 Dual

MaxLite LED Vapor Tight Linear Fixture

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

InstructIon Manual KrEs EQuIPMEnt stands

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Superdryer Dehumidifiers

MACURCO INC. CONTROLLERS & CARBON MONOXIDE DETECTORS SS103-3A, SS103-10A SS102H, SS102HC-1 INSTALLATION & OPERATING INSTRUCTIONS

WIRING MODEL 20 Low Water Cut-Off and Pump Control MAXIMUM PRESSURE: 20 PSI INTERNAL WIRING BLUE WHITE UPPER PROBE (FEED OFF) FEED PROBE (FEED ON) ALL

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

ion Genesis Pump Controller

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

D E S I G N G U I D E REVISED 10 / 2017

IMPORTANT SAFETY INFORMATION

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

D E S I G N G U I D E REVISED 9 / 2018

Intelligent Lighting Controller

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Wiring Diagrams Units Produced After April 20, 2009

Spa Control System OWNER S MANUAL

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Transcription:

NOVA Energy & Automation Product Specifications 4 Breaker Main Disconnect Panel with Undervoltage Trip Model NEAS-44125-G-UVR-C 03 January 2012

Product Description 1. Standard Applications The Nova 4 Breaker Main Disconnect Panel is an integrated Main Circuit Breaker Panel with Undervoltage trip specifically designed to meet the requirements of Siemens Medical imaging installations. The low voltage internal control panel provide a safe, low voltage interface between the imaging equipment, control, and room line voltage. Under Voltage Release Details Figure 1 Main Disconnect Panel One Line The Under voltage release mechanism trips the circuit breaker by removing power from an internal coil. Power must be present and applied to the UVR coil before the main disconnect can be energized. If power is not provided to the UVR coil the breaker will continue to trip while one attempts to turn it on. UVR coils are designed to trip when its applied voltage falls between 35 to 70% of nominal rating. The UVR mechanism is best suited for interlocking a number of other equipment safety checks, as all circuits would need to be satisfied and all normally closed contacts would be wired in series. Any one of the contacts could open thereby tripping the circuit breaker. Another benefit of the UVR is that it will not automatically restart the equipment after a power outage. It would require that a person would go to the breaker panel and manually energize it after checking to see that conditions are safe to do so. Co Author: JF 2

2. System Compatibility Siemens Medical Solutions Cath Lab: Artis Zee Ceiling and several other related installations Please select item NEAS-44125-G-UVR-C 3. Identification Siemens Medical Solutions Cath Lab: The proper distribution panel can be identified in the Siemens Constructions Drawings sheet E-501 Power Diagram item MP NEAS-44125-G-UVR-C Equal to item P2E1E4125FTS with related components A, B, C, D, E, F,H, J, K: 120VAC U.V. trip, ground bus bar, 100A 3P feeder (to PU1), 50A 3P feeder (to SC1), 20A 2P feeder (to RMP), 480-120 transformer 4. Features/ Benefits Features Benefits Integrated design provides all of the Main Disconnect Panel s controls into an easy to configured panel with Undervoltage Trip mechanism integrated into the main Circuit Breaker Utilizes heavy duty ABB Circuit Breaker to handle inrush currents. UL and cul listed to conform to NEC. Labeled to conform to NFPA99, NFPA-70. Provides Short Circuit and Overload Protection Provides differential protection Internally derived 120 Vac Under Voltage Release Neutral Block and Ground Block Factory wired and tested. Single point main disconnect and termination point Factory wired to match Siemens equipment and tested Designed, tested, and installed on several projects worldwide Manufactured using the highest quality components for high reliability and long life Provides protection for sensitive electronic equipment Manufactured to a tolerance which exceeds the specifications of Siemens equipment. Field adjustable overload and instantaneous trip Reduced weight- all components are within a small 40lb enclosure Field adjustable ranges allow for coordination with the facility distribution coordination. Eliminated the need for multiple control panels for short circuit, overload and Emergency Power Off Reduces installation time and cost by eliminating delays in obtaining individually enclosed components and by eliminating on site assembly. Provides a standardized platform for other future modifications or upgrades. Co Author: JF 3

Figure 2 Main Disconnect Panel Front View 5. Specifications Model Application Input Voltage Input Current Output Voltage Output over current protection NEAS-44125-G-UVR-C Main Disconnect Panel for Medical Imaging Equipment 480/277 VAC, 3 Phase 5-wire: 3 Phase Conductors + Neutral + Ground AC input (maximum): 125 A (other Amp ratings are available) 480/277 VAC, 3 Phase (follows input voltage) 125A 3P Main 100A 3P for PU1 50A 3P for SC1 20A 2P for RMP Control Voltage Emergency Power Off Controls Operator Controls Internally derived 120VAC 250VA for Undervoltage Trip Circuit 120VAC Undervoltage release (N.O) Compatible with 120 VAC and Low Voltage EPO operator devices Co Author: JF 4

Compatible Estop Buttons Door Mounted Devices Grounding Short Circuit Current Protection Instantaneous Trip Settings Approvals Normally closed Siemens Cath: 4 ESTOPS- 2 N.C. contacts Direct -Mount Circuit Breaker Operating Mechanism with OSHA Lockout Isolated and non isolated ground bar 25 kaic Field adjustable from 1-10x of over current rating UL/cUL Figure 3 Main Disconnect Panel Interior View Co Author: JF 5

6. Warranty This limited warranty set forth below is given by Nova Automation ( Seller ) with respect to the electrical equipment ( Product ) packaged with this limited warranty. The Product, when delivered to you in new condition in its original packaging, is warranted against defects in materials or workmanship as follows: For a period of one (1) year from the date of original purchase, defective parts or a defective Product returned to a Seller, or its authorized service providers, as applicable, and proven to be defective upon inspection, will be repaired, or exchanged for a new Product, as determined by the Seller, or the authorized service provider. This limited warranty covers all defects encountered in normal use of the Product, and does not apply in the following cases: Loss of or damage to the Product due to abuse, mishandling, alteration, accident, electrical current fluctuations, failure to follow operating, maintenance or environmental instructions prescribed by Seller, failure to follow Sellers installation instructions, or service performed by someone other than Seller or its authorized service provider. Nova assumes no responsibility for labor or freight costs incurred in connection with the installation, removal, or replacement of products determined to be defective or any consequential or incidental damages arising from the use of the product. Nova Automations entire liability on any claim of loss or damage resulting from a defective product is limited to the replacement of the product. WARRANTY IS VOID IF PRODUCT IS NOT USED FOR THE PURPOSE FOR WHICH IT WAS MANUFACTURED. 7. Product Service and Technical Assistance Nova Automation, LLC 2722 N. Avondale Blvd Milwaukee WI 53210 PH# 262-309-2950 Website: www.novaautomation.net Co Author: JF 6

8. Approvals Prepared By ([Job Title]) This document requires the following approvals Approved By ([Job Title]) ([Job Title]) Approval Date Co Author: JF 7