PULSE WIDTH MODULATING VALVES

Similar documents
June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

Bulletin , March Electric Hot Gas Bypass Valves

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostatic Expansion Valves Type TR 6

Product Catalog VALVES

Refrigerant Valves/Accessories

General information on refrigerant controllers

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

Suction Accumulators. Introduction. Suction Accumulators

Typical Piping Diagram

Head Pressure Control Valves

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

Owner s Manual Therma-Stor II Heat Recovery System

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

Emerson Superheat Control. The smart solution for your application

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

water to water heat pumps

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

Sporlan Valve Division Parker Hannifan/CIC Group

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

REFRIGERATION PRODUCTS

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Heat Reclaim. Benefits,Methods, & Troubleshooting By Dave Demma, Manager Supermarket Sales, Sporlan Division - Parker Hannifin Corporation

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Copeland Scroll Condensing Units for the Food Service Market

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Air-Cooled Condensing Units with Compact Screw Compressors

Check valve Types NRV and NRVH

Above & Beyond. Refrigerated Compressed Air Dryers

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

These valves can also be ordered as a bidirectional valve, allowing control of flow in both directions for use on heat pump applications.

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

RCTA Horizontal Evaporator Coil Installation Instructions

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

MAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

JCseries EVAPORATIVE CONDENSER. engineering data

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

APPLICATION DATA SHEET

GTX Series Thermal Xchange Cycling Refrigeration Dryers GREAT LAKES AIR ANDARD ELECTRONIC DRAIN 5 -YEAR WARRANTY F PRESSURE DEWPOINT

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

Tube-in-tube heat exchanger Type HE

Call us today! (800)

PL Series Premier Indoor Plenum Coils

Condensing Unit Installation and Operating Instructions

Commercial Refrigeration

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Low Profile Unit Coolers

Condensing Unit Installation and Operating Instructions

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Call us today! (800)

Call us today! (800)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

Installation Instructions

REFRIGERATION AND AIR CONDITIONING RÉFRIGÉRATION ET CLIMATISATION POST-SECONDARY NIVEAU POSTSECONDAIRE

REFRIGERATION PRODUCTS

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Low Profile Unit Coolers

PAJ3. Product Specifications

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

Installation Instructions

MACH N-407 Heat Pump Air-Cooled Chiller

Compressors, Chillers & Condensers

horizontal air discharge outdoor discus condensing unit

Outstanding Performance; Application Flexibility

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

PACKAGED AIR COOLED Product Data Catalog

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

Installation, Operation, and Maintenance Information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

2 shp 13 lc 1 36 t - 1 a

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

HEAT PUMPS. Carrier Corporation GT72-01 Cat. No

500 EX Fusion Compressor Series

TOSHIBA AIR CONDITIONING

Transcription:

PULSE WIDTH MODULATING VALVES PARKER PULSE WIDTH MODULATING VALVES MODEL HP P4144 MODELS CS & DS P4145 Features Long life (100 million cycles). Suitable for all common refrigerants except ammonia. Maximum use of entire evaporator surface with minimum superheat result in increased efficiency (SEER). No superheat adjustment necessary. Wide range capacity results in reduced inventory. Fast, precise response to load changes. Readily adaptable to providing functions related to Maximum Operating Pressure (M.O.P.). Remote system control. Readily interfaces with a microcomputer and variable speed capacity compressor technology. Standard angle pattern solder connections: 3/8 ODM x 3/8 ODM (Model HP) 3/8 ODM x 1/2 ODF (Models CS/DS) (Consult factory for different connections.) U.L. Recognized File MH5567. 628

PULSE WIDTH MODULATING VALVES PARKER PULSE WIDTH MODULATING VALVES Capacity Tables Pulse Modulating s R-12 US Extended Capacities in MBTU/H Type Evaporator Temp F Pressure Drop (psig) 40 0-40 40 60 80 100 120 140 60 80 100 120 140 160 80 100 120 140 160 180 Orifice HP120 1/64 0.68 0.84 0.97 1.08 1.18 1.28 0.71 0.82 0.92 1.01 1.09 1.16 0.37 0.41 0.45 0.49 0.52 0.55 HP130 1/32 1.20 1.47 1.70 1.90 2.08 2.25 1.25 1.44 1.61 1.77 1.91 2.04 0.65 0.72 0.79 0.85 0.91 0.97 HP145 3/64 2.47 3.02 3.49 3.90 4.27 4.61 2.57 2.97 3.32 3.63 3.92 4.19 1.33 1.48 1.62 1.75 1.87 1.33 HP160 1/16 4.14 5.06 5.85 6.54 7.16 7.74 4.31 4.97 5.56 6.09 6.58 7.03 2.22 2.48 2.72 2.94 3.14 3.33 CS1073 5/64 7.23 8.86 10.23 11.43 12.52 13.53 7.53 8.69 9.72 10.65 11.50 12.29 3.89 4.34 4.76 5.14 5.50 5.83 CS1085 3/32 9.40 11.51 13.29 14.86 16.28 17.59 9.79 11.30 12.63 13.84 14.96 15.98 5.05 5.65 6.19 6.68 7.14 7.58 DS1100 7/64 11.57 14.16 16.36 18.29 20.03 21.64 12.04 13.90 15.54 17.03 18.39 19.66 6.22 6.95 7.81 8.22 8.79 9.32 DS1120 1/8 13.13 16.08 18.57 20.76 22.74 24.56 13.67 15.78 17.64 19.33 20.88 22.32 7.05 7.89 8.64 9.33 9.98 10.58 R-22 US Extended Capacities in MBTU/H Type Evaporator Temp F Pressure Drop (psig) 40 0-40 40 60 80 100 120 140 60 80 100 120 140 160 80 100 120 140 160 180 Orifice HP120 1/64 1.39 1.61 1.80 1.97 2.13 2.28 1.23 1.42 1.58 1.74 1.87 2.00 0.74 0.81 0.87 0.93 0.99 1.04 HP130 1/32 2.45 2.83 3.16 3.47 3.74 4.00 2.16 2.49 2.78 3.05 3.29 3.52 1.30 1.42 1.53 1.64 1.74 1.83 HP145 3/64 5.03 5.81 6.50 7.12 7.69 8.22 4.43 5.11 5.72 6.26 6.76 7.23 2.66 2.92 3.15 3.37 3.57 3.77 HP160 1/16 8.44 9.74 10.89 11.93 12.88 13.77 7.42 8.57 9.58 10.50 11.34 12.12 4.46 4.89 5.28 5.65 5.99 6.31 CS1073 5/64 14.75 17.03 19.04 20.86 22.53 24.08 12.98 14.99 16.76 18.35 19.83 21.19 7.81 8.55 9.24 9.87 10.47 11.04 CS1085 3/32 19.17 22.14 24.75 27.12 29.29 31.31 16.87 19.48 21.78 23.86 25.77 27.55 10.15 11.12 12.01 12.84 13.62 14.35 DS1100 7/64 23.59 27.24 30.56 33.36 36.04 38.52 20.76 23.97 26.80 29.36 21.71 33.90 12.49 13.68 14.77 15.79 16.75 17.66 DS1120 1/8 26.78 30.92 34.57 37.87 40.90 43.73 23.56 27.21 30.42 33.32 35.99 38.48 14.17 15.53 16.77 17.93 19.02 20.04 R-404A US Extended Capacities in MBTU/H Type Evaporator Temp F Pressure Drop (psig) 40 0-40 40 60 80 100 120 140 60 80 100 120 140 160 80 100 120 140 160 180 Orifice HP120 1/64 0.92 1.06 1.19 1.30 1.41 1.50 0.78 0.90 1.01 1.11 1.19 1.28 1.00 0.49 0.53 0.57 0.61 0.64 HP130 1/32 1.62 1.87 2.09 2.29 2.47 2.64 1.37 1.59 1.78 1.94 2.10 2.25 0.79 0.87 0.94 1.00 1.06 1.12 HP145 3/64 3.32 3.83 4.29 4.70 5.07 5.42 2.82 3.26 3.64 3.99 4.31 4.61 1.63 1.78 1.93 2.06 2.19 2.30 HP160 1/16 5.57 6.43 7.19 7.87 8.50 9.09 4.73 5.46 6.11 6.69 7.23 7.73 2.73 2.99 3.23 3.45 3.66 3.86 CS1073 5/64 9.73 11.24 12.57 13.77 14.87 15.90 8.27 9.55 10.68 11.70 12.64 13.51 1.00 5.23 5.65 6.04 6.41 6.75 CS1085 3/32 12.65 14.61 16.34 17.90 19.33 20.67 10.76 12.42 13.89 15.21 16.43 17.57 6.21 6.80 7.35 7.85 8.33 8.78 DS1100 7/64 15.57 17.98 20.10 22.02 23.78 25.43 13.23 15.28 17.09 18.72 20.22 21.61 7.64 8.37 9.04 9.66 10.25 10.80 DS1120 1/8 17.67 20.41 22.82 24.99 27.00 28.86 15.02 17.35 19.39 21.24 22.95 24.53 8.67 9.50 10.26 10.97 11.63 12.26 Liquid Refrigerant Temperature Correction Factor Liquid Line Temp F 50 60 70 80 90 100 110 120 130 140 Multiplier R-12 1.30 1.24 1.18 1.12 1.06 1.00 0.94 0.88 0.81 0.75 Multiplier R-22 1.29 1.23 1.17 1.12 1.06 1.00 0.94 0.88 0.82 0.76 Multiplier R-404A 1.56 1.45 1.34 1.23 1.12 1.00 0.88 0.75 0.62 0.48 Multiplier R-134a 1.35 1.28 1.21 1.14 1.07 1.00 0.93 0.86 0.78 0.71 NOTE: All capacities shown are based on 100 F liquid entering the valve, 40 F saturated evaporator temperature and 50% duty cycle during steady-state operation. Nominal capacities are shaded. Duty Cycle Correction Factor Duty Cycle Correction Factor 30% 0.7 40% 0.8 50% 1.0 60% 1.1 70% 1.2 80% 1.4 90% 1.5 100% 1.7 629

HOT GAS DEFROST VALVES PARKER 3-WAY HOT GAS DEFROST VALVES RS65 P4139 P4140 RS55 Suction Line Capacities Tons Capacities Tons Evaporator Temperatures in @ 1 psi Pressure Fahrenheit Degrees Drop 20 10 0-10 -20-40 R-12 2.9 2.6 2.3 2.0 1.7 1.3 R-22 4.4 4.0 3.5 3.1 2.7 2.0 R-502 3.5 3.1 2.8 2.4 2.1 1.6 R-134a 4.2 3.7 3.2 2.8 2.4 1.7 R-404A (HP-62)* 3.9 3.5 3.1 2.8 2.4 1.8 R-507 (AZ-50)* 3.9 3.5 3.1 2.8 2.4 1.8 *AZ-50 & HP-62 are products of Allied Signal & DuPont respectively. Application Designed for hot gas defrost from the suction side of the evaporator coil, these valves are commonly used with modern multiplex systems. Connections Type Evaporator Line Suction Line Discharge Line RS-55 1-1/8 ODF 1-1/8 ODF 7/8 ODF RS-65 RS-70 1-3/8 ODF 1-3/8 ODF 7/8 ODF RS65, RS70 Suction Line Capacities Tons Capacities Tons @ 1 psi Pressure Drop Evaporator Temperatures in Fahrenheit Degrees 20 10 0-10 -20-40 R-12 6.9 6.1 5.4 4.7 4.0 3.0 R-22 10.5 9.4 8.4 7.4 6.5 4.9 R-502 8.4 7.4 6.6 5.8 5.0 3.7 R-134a 10.0 8.8 7.6 6.6 5.6 4.0 R-404A (HP-62)* 9.4 8.4 7.4 6.6 5.8 4.3 R-507 (AZ-50)* 9.4 8.4 7.4 6.6 5.8 4.3 *AZ-50 & HP-62 are products of Allied signal & DuPont respectively. P4141 630

ALCO 4031RD 3-WAY SOLENOID VALVE FOR HEAT RECLAIM APPLICATIONS 4031RD Series 3-Way Solenoid s are designed to meet the requirements of the high temperatures and pressures existing in compressor discharge gas applications. The 4031RD is designed specifically to divert discharge gas to an auxiliary condenser for heat reclaim applications. Normal Operation: When the solenoid coil is de-energized, the valve is in the normal operating mode and the refrigerant gas is diverted to the normal condenser. With the 3-way solenoid pilot de-energized, the slide is positioned so as to connect to ports D1 with B, and A with S1. When the pilot is de-energized, high pressure discharge gas builds up on the end of the main slide. The other end of the main slide is isolated from the high pressure suction gas. The unbalance force, due to the difference between discharge and suction pressures acting on the full end area of the main slide holds the slide in the position as shown in Figure 1. HEAT RECLAIM VALVES FEATURES P1362 UL file number MP604 CSA file number LR3204 Superior control in diverting discharge gas to an auxiliary condenser for heat reclaim All copper fittings for easy brazing High capacity, less pressure drop with higher system efficiency Operates in any position Rugged internal construction Heat Reclaim Operation: When the solenoid is energized, the slide in Long-life Molded Coils - water, chock, and vibration protection in the pilot solenoid valve shifts, now connecting coil winding pilot ports D1 with A, and B with S1. With the pilot solenoid so positioned, the discharge pressure imposed on the other end of the main slide, will flow through the pilot solenoid valve to the suction side of the system. At the right end of the main slide, high pressure discharge gas will accumulate so as to increase the pressure. An unbalanced force in that direction is again due to the difference between discharge and suction pressures acting on opposite ends of the main slide. This unbalanced force moves the main slide to the position as shown in Figure 2 and the force unbalance across the area of the main slide holds the slide in the new position. P1363 P1364 NOMENCLATURE example: 4031RD BF 5 5 4031RD B F 5 5 ODF Inlet Connection Outlet Connection Series Size (in 1/8 ) (in 1/8 ) P1365 P1366 ALCO Heat Reclaim s provide superior control whether your condensers are parallel or in series. Flow through auxiliary condenser is accomplished when the 4031RD is energized. 631

ALCO 4031RD DIMENSIONAL DATA HEAT RECLAIM VALVES 4031RDB P1367 P1368 VALVE INLET D OUTLET C1, C2 A B E F G H J 4031RDBF 5 5 5/8 ODF 5/8 ODF 5/8 5/8 5/8 5/8 3-1/4 2-5/8 5-7/8 4031RDBF 7 7 7/8 ODF 7/8 ODF 7/8 7/8 7/8 7/8 3-1/4 3-3/4 7-63/64 4031RDC P1369 P1370 4031RD DISCHARGE GAS EXTENDED CAPACITY TABLE - TONS VALVE TYPE EVAPORATOR TEMP F PRESSURE DROP ACROSS VALVE - PSI R-134A R-22 R-404A/R-507 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 40 2.8 4.0 4.8 5.5 6.1 4.1 5.8 7.0 8.2 9.0 3.3 4.5 5.6 6.5 7.2 20 2.6 3.7 4.5 5.2 5.8 3.9 5.4 6.6 7.6 8.4 3.0 4.2 5.2 5.8 6.6 4031RDBF 5 5 0 2.4 3.4 4.3 4.9 5.5 3.6 5.1 6.1 7.1 8.0 2.8 3.9 4.7 5.5 6.1-20 2.3 3.2 3.9 4.5 5.0 3.4 4.7 5.8 6.7 7.5 2.5 3.5 4.3 5.0 5.5-40 2.1 2.9 3.6 3.9 4.6 3.1 4.5 5.4 6.3 7.0 2.2 3.2 3.9 4.4 4.8 All capacities shown are at 40 F Evaporator Temperature. For other temperatures, refer to correction factor tables. 632

REVERSING VALVES ALCO 401RD 4-WAY STEEL REVERSING VALVE FOR REVERSE CYCLE SYSTEMS ALCO 401RD Series 4-Way Reversing s are designed for use on energy-conserving, reverse-cycle comfort systems. Heating Cycle (see Figure 1) The system is on heating cycle with discharge gas flowing through ports D to C2, making the indoor coil the condenser. The suction gas is flowing from the outdoor coil (evaporator) through reversing ports C1 to S and back to the compressor. With the 4-way solenoid pilot de-energized, the slide s position connects the port D1 to B and A to S1. Cooling Cycle (see Figure 2) P1371 UL file number MP604 CSA file number LR44912 When the coil is energized, the slide in the pilot solenoid valve shifts, now connecting pilot ports D1 to A and B to S1. The system has now changed over to the cooling cycle with the discharge gas flowing through reversing valve ports D to C1, making the outdoor coil the through port C2 to S, thus making the indoor coil the evaporator. CAUTION: Depending on the manner in which the reversing valve is piped into the system, power failure to the pilot solenoid valve coil will cause the system to fail-safe on either the heating or cooling cycle. In the diagrams shown below, the valve is piped to fail-safe on heating. In order to fail-safe on cooling, the indoor coil would be connected to the reversing valve port C and the outdoor coil connected to port C2. FEATURES High efficiency and higher capacity through suction and discharge All stainless steel pilot enclosing tube for longer life Connections to fit your system SPECIFICATIONS Maximum safe working pressure: 500 PSIG Compatible with R-134a, R-22, R-404A, R-507, and the new CFC, HCFC, and HFC refrigerants MOPD: 400 PSIG Coil style: Open frame P1372 633

REVERSING VALVES NOMENCLATURE example: 401RD 6F46 401R D 1 F 3 5 Design Nominal Rating F = ODF Discharge Connection Outlet Connection Series Series (in tons) connections (in 1/8 ) (in 1/8 ) 410R CAPACITY TABLE VALVE TYPE NOMINAL CAPACITIES* R-134a R-22 R-404A/R-507 401RD1 0.9 1.5 1.1 401RD10 7.2 11.5 8.7 401RB15 15.2 *Based on 100 F condensing temperature, 40 F evaporator and a 2 PSI pressure drop across the valve suction ports. P1374 TYPICAL 401R PIPING DIAGRAM P1375 P1376 634

ALCO 401R DIMENSIONAL DATA REVERSING VALVES 401RD-1 P1380 401RD-10 P1381 P1382 401RB P1383 P1384 VALVE TYPE CAPACITY* CONNECTIONS NUMBER (tons) Discharge 1, S, 2 A B C E F G H J K L M N 401RD134 1.5 3/8 ODM 1/2 ODF 1/2 1/2 5/8 1-1/8 2-13/16 1-15/16 4-3/4 2-5/16 2-25/32 5-9/16 2-31/64 2-41/64 401RD1F34 1.5 3/8 ODF 1/2 ODF 1/2 1/2 5/8 1-1/8 2-13/16 1-15/16 4-3/4 2-5/16 2-25/32 5-9/16 2-31/64 2-41/64 401RD135 1.5 3/8 ODM 5/8 ODF 1/2 5/8 55/64 1-1/8 2-7/8 1-15/16 4-13/16 2-11/32 2-25/32 5-9/16 2-31/64 2-41/64 401RD1F35 1.5 3/8 ODF 5/8 ODF 1/2 5/8 55/64 1-1/8 2-7/8 1-15/16 4-13/16 2-11/32 2/25/32 5-9/16 2-31/64 2-41/64 401RD10F46 11.5 1/2 ODF 3/4 ODF 7/16 11/16 1-5/16 1-3/4 3-7/8 3-7/32 7-3/32 3-3/8 4-15/32 8-15/16 3-1/16 3-11/32 401RD10F47 11.5 1/2 ODF 7/8 ODF 7/16 13/16 1-5/16 1-3/4 3-7/8 3-7/32 7-3/32 3-3/8 4-15/32 8-15/16 3-1/16 3-11/32 401RD10F49 11.5 1/2 ODF 1-1/8 ODF 7/16 31/32 1-5/16 1-3/4 3-7/8 3-7/32 7-3/32 3-3/8 4-15/32 8-15/16 3-1/16 3-11/32 401RD10F57 11.5 5/8 ODF 7/8 ODF 9/16 13/16 1-5/16 1-3/4 4-3/8 4-3/8 8-3/4 4-3/8 4-15/32 8-15/16 3-1/16 3-11/32 401RD10F59 11.5 5/8 ODF 1-1/8 ODF 9/16 31/32 1-5/16 1-3/4 3-7/8 3-7/32 7-3/32 3-3/8 4-15/32 8-15/16 3-1/16 3-11/32 401RD1067 11.5 3/4 ODM 7/8 ODF 3/4 13/16 1-5/16 1-3/4 3-7/8 3-7/32 7-3/32 3-3/8 4-15/32 8-15/16 3-1/16 3-11/32 401RD10F67 11.5 3/4 ODF 7/8 ODF 11/16 13/16 1-5/16 1-3/4 3-7/8 3-7/32 7-3/32 3-3/8 4-15/32 8-15/16 3-1/16 3-11/32 401RD1069 11.5 3/4 ODM 1-1/8 ODF 3/4 31/32 1-5/16 1-3/4 3-7/8 3-7/32 7-3/32 3-3/8 4-15/32 8-15/16 3-1/16 3-11/32 401RD10F69 11.5 3/4 ODF 1-1/8 ODF 11/16 31/32 1-5/16 1-3/4 3-7/8 3-7/32 7-3/32 3-3/8 4-15/32 8-15/16 3-1/16 3-11/32 4011079 11.5 7/8 ODM 1-1/8 ODF 31/32 1-5/16 1-3/4 3-7/8 3-7/32 7-3/32 3-3/8 4-15/32 8-15/16 3-1/16 3-11/32 401RD10F79 11.5 7/8 ODF 1-1/8 ODF 13/16 31/32 1-5/16 1-1/2 3-7/8 3-7/32 7-3/32 3-3/8 4-15/32 8-15/16 3-1/16 3-11/32 401RD10611 11.5 3/4 ODM 1-3/8 ODM 3/4 1-1/32 1-1/2 1-1/2 5-57/64 3-7/32 9-7/64 4-35/64 4-15/32 8-15/16 3-1/16 3-11/32 401RD10F711 11.5 7/8 ODF 1-1/8 ODF 13/16 1-1/32 1-1/2 1-1/2 5-57/64 4 9-57/64 4-35/64 4-15/32 8-15/16 3-1/16 3-11/32 401RB15F711 15.2 7/8 ODF 1-3/8 DF 7/8 3/4 1-5/8 1-29/32 5-1/2 4 9-1/2 4-1/2 4-1/2 9 2-61/64 2-7/32 401RB15F911 15.2 1-1/8 ODF 1-3/8 ODF 1-1/8 29/32 1-5/8 1-29/32 5-1/2 4 9-1/2 4-1/2 4-1/2 9 2-61/64 2-7/32 *Nominal Capacity R-22. All capacities shown are at 40 F Evaporator Temperature. For other temperatures refer to correction factor tables. 635

REVERSING VALVES 401R SUCTION GAS EXTENDED CAPACITY TABLE - TON VALVE TYPE EVAPORATOR TEMP F PRESSURE DROP ACROSS VALVE - PSI R-134a R-22 R-404A/R-507 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5.66.91 1.1 1.2 1.3 1.0 1.5 1.7 1.9 2.1.70 1.1 1.4 1.6 1.8 401RD1 401RD10 40 5.2 7.2 8.6 9.8 10.6 7.8 11.5 13.1 15.1 16.7 5.5 8.7 10.9 12.5 14.1 401RB15 8.6 11.5 13.9 16.3 17.3 10.4 15.2 17.6 20.0 22.0 6.8 10.9 13.5 15.6 17.4 401RD1.52.71.86.97 1.1.80 1.1 1.3 1.5 1.7.58.89 1.1 1.3 1.4 401RD10 20 4.1 5.6 6.7 7.6 8.2 6.3 8.8 10.5 11.9 13.2 4.6 7.0 8.6 9.9 10.9 401RBD15 6.7 9.1 11.0 12.5 14.4 8.8 11.6 14.0 15.6 17.6 5.6 8.6 10.6 12.2 13.5 401RD1.41.55.65.73.78.65.85 1.0 1.2 1.3.47.69.63.96 1.1 401RD10 0 3.2 4.3 5.1 5.7 6.1 5.1 6.7 8.2 9.2 10.1 3.7 5.5 6.6 7.5 8.3 401RB15 5.3 7.2 8.2 9.1 9.6 6.8 8.8 10.8 12.0 13.6 4.5 6.5 7.9 9.0 9.9 401RD.30.40.47.51.52.49.65.77.86.94.37.52.63.71.77 401RD10-20 2.4 3.2 3.7 4.0 4.1 3.8 5.1 6.1 6.8 7.4 2.9 4.1 5.0 5.6 6.1 401RB15 3.8 5.3 5.8 6.2 6.7 5.2 6.8 8.0 8.8 10.0 3.5 4.9 5.9 6.7 7.3 capacities are based on 100 F condensing temperature. For temperatures other than 100 F, use the multiplier factors below. CONDENSING TEMPERATURE 70 80 90 100 110 120 130 140 MULTIPLIER 1.15 1.10 1.05 1.00.95.90.85.80 RV SUCTION GS EXTENDED CAPACITY TABLE TONS R-22 VALVE TYPE EVAPORATOR TEMP F PRESSURE DROP ACROSS VALVE - PSI R-22 1 2 3 4 5 RV2 1.66 2.35 2.87 3.32 3.71 RV3 45 2.23 3.15 3.86 4.46 4.99 RV4 3.14 4.44 5.44 6.28 7.02 RV2 1.36 1.92 2.35 2.71 3.03 RV3 25 1.82 2.58 3.16 3.65 4.08 RV4 2.57 3.63 4.45 5.13 5.74 RV2 1.09 1.54 1.88 2.06 2.27 RV3 5 1.46 2.07 2.53 2.78 3.02 RV4 2.57 3.63 4.45 5.13 5.74 RV2 0.86 1.21 1.39 1.56 1.70 RV3-15 1.15 1.63 1.87 2.06 2.19 RV4 1.62 2.29 2.61 2.89 3.10 capacities are based on 120 F liquid saturated evaporator, and 10 F superheat at the valve inlet. 636

ALCO RV2 AND RV3 DIMENSIONAL DATA REVERSING VALVES P1379 RV VALVE CONNECTIONS A B DISCHARGE 1, S, 2 MIN. MIN. C D E F RV2F45 1/2 ODF 5/8 ODF 3/8 1/2 2.79 2.39.95 15 RV2F46 1/2 ODF 3/4 ODF 3/8 5/8 3.42 3.25 1.27 20 RV2F36 3/8 ODF 3/4 ODF 5/16 5/8 3.42 3.25 1.27 20 RV2F46D1* 1/2 ODF 3/4 ODF 3/8 5/8 3.42 3.25 1.27 20 RV2F35 3/8 ODF 5/8 ODF 5/16 1/2 2.79 2.39.95 15 RV2F45D1* 1/2 ODF 5/8 ODF 3/8 1/2 2.79 2.39.95 15 RV2F35D1* 3/8 ODF 5/8 ODF 5/16 1/2 2.79 2.39.95 15 RV2F36D1* 3/8 ODF 3/4 ODF 5/16 5/8 3.42 3.25 1.27 20 RV3F45 1/2 ODF 5/8 ODF 3/8 1/2 2.79 2.39.95 15 RV3F46 1/2 ODF 3/4 ODF 3/8 5/8 3.42 3.25 1.27 20 RV3F36 3/8 ODF 3/4 ODF 5/16 5/8 3.42 3.25 1.27 20 RV3F46D1* 1/2 ODF 3/4 ODF 3/8 5/8 3.42 3.25 1.27 20 RV3F35 3/8 ODF 5/8 ODF 5/16 1/2 2.79 2.39.95 15 RV3F45D1* 3/8 ODF 5/8 ODF 3/8 1/2 2.79 2.39.95 15 RV3F35D1* 3/8 ODF 5/8 ODF 5/16 1/2 2.79 2.39.95 15 RV3F36D1* 3/8 ODF 3/4 ODF 5/16 5/8 3.42 3.25 1.27 20 * D denotes Discharge Tube is off-center. 637

REVERSING VALVES ALCO RV 4-WAY BRASS REVERSING VALVE FOR REVERSE-CYCLE SYSTEMS APPLICATION Designed for use on heat pump systems. Reverse Cycle gas defrost. FEATURES High strength slide carrier. Fewer parts. High capacity pilot. -Greater tolerance to contaminates. Low heat transfer slide. Greater wear resistance of seals. Stainless steel pilot bracket. OPTIONS Tube connection sizes Discharge 1/2 and 5/8 ODF/ODM Suction & Coil 3/4 and 7/8 ODF SPECIFICATIONS Nominal 2, 3, & 6 ton sizes. Maximum working pressure 500 psig. MOPD: 400 psig. Minimum operating pressure differential: 10 psi. Maximum operating temperature: 250 F. External leakage: 0.1 oz/yr. UL file number: MP604. CSA file number: LR44912. UL file number MP604 CSA file number LR44912 P1377 NOMENCLATURE Sample: RV44F46 RV 4 F 4 6 Series Nominal Rating (in tons) F = ODF connections (omit for ODM) Discharge Connection (in 1/8 ) Suction Connection (in 1/8 ) ORDERING INFORMATION FOR RV SERIES VALVES PCN* DESCRIPTION 062796 RV 2 - F 34 VLC 062199 RV 2 - F 35 VLC 061795 RV 3 - F 35 VLC 061790 RV 3 - F 45 VLC 061792 RV 3 - F 46 VLC 062168 RV 4 - F 46 VLC 062173 RV 4 - F 47 VLC 062162 RV 4-56 VLC 062176 RV 4 - F 57 VLC Standard Product Offering. *Product Code Number. RV SUCTION GAS EXTENDED CAPACITY TABLE IN TONS FOR R-22 AND R-410A EVAPORATOR TEMP. ( F) +45 +25 +5-15 PRESSURE DROP ACROSS VALVE - PSI VALVE R-22/R-407C R-410A TYPE 1 2 3 4 5 1 2 3 4 5 RV2 1.66 2.35 2.87 3.32 3.71 2.14 3.03 3.71 4.29 4.56 RV3 2.23 3.15 3.86 4.46 4.99 2.88 4.07 4.99 5.76 6.16 RV4 3.24 4.58 5.61 6.48 7.25 4.19 5.92 7.25 8.37 8.69 RV2 1.36 1.92 2.35 2.71 3.03 1.75 2.48 3.03 3.50 3.92 RV3 2.57 3.63 4.45 5.13 5.74 3.42 4.84 5.93 6.84 7.65 RV4 2.65 3.75 4.59 5.30 5.92 2.35 3.33 4.08 4.71 5.26 RV2 1.09 1.54 1.88 2.06 2.27 1.41 1.99 2.44 2.64 2.90 RV3 1.46 2.07 2.53 2.78 3.02 1.89 2.67 3.27 3.54 3.83 RV4 2.12 3.00 3.68 3.93 4.27 2.75 3.88 4.76 5.01 5.42 RV2 0.86 1.21 1.39 1.56 1.70 1.11 1.57 1.77 1.98 2.14 RV3 1.15 1.63 1.87 2.06 2.19 1.49 2.10 2.35 2.57 2.71 RV4 1.67 2.37 2.64 2.91 3.11 2.16 3.06 3.33 3.65 3.86 NOTE: capacities are based on 120 F liquid, saturated evaporator, and 10 F superheat at the valve inlet. 638

REVERSING VALVES ALCO RV 4-WAY BRASS REVERSING VALVE FOR REVERSE-CYCLE SYSTEMS RV2 & RV3 DIMENSIONAL DATA DIMENSIONS SHOWN ARE IN INCHES; FRACTIONS (DECIMALS) RV VALUE CONNECTIONS (in.) NOTE: D denotes Discharge Tube is off-center. A MIN. B MIN. Discharge 1, S, 2 C D E F RV2F45 1/2 ODF (.50) 5/8 ODF (.63) 3/8 (.38) 1/2 (.50) 2-25/32 (2.79) 2-25/64 (2.39) 61/64 (.95) 15 RV2F46 1/2 ODF (.50) 3/4 ODF (.75) 3/8 (.38) 5/8 (.63) RV2F36 3/8 ODF (.38) 3/4 ODF (.75) 5/16 (.31) 5/8 (.63) 3-27/64 (3.42) 3-1/4 (3.25) 1-17/64 (1.27) 20 RV2F46D1* 1/2 ODF (.50) 3/4 ODF (.75) 3/8 (.38) 5/8 (.63) RV2F35 3/8 ODF (.38) 5/8 ODF (.63) 5/16 (.31) 1/2 (.50) RV2F45D1* 1/2 ODF (.50) 5/8 ODF (.63) 3/8 (.38) 1/2 (.50) 2-25/32 (2.79) 2-25/64 (2.29) 61/64 (.95) 15 RV2F35D1* 3/8 ODF (.38) 5/8 ODF (.63) 5/16 (.31) 1/2 (.50) RV2F36D1* 3/8 ODF (.38) 3/4 ODF (.75) 5/16 (.31) 5/8 (.63) 3-27/64 (3.42) 3-1/4 (3.25) 1-17/64 (1.27) 20 RV3F45 1/2 ODF (.50) 5/8 ODF (.63) 3/8 (.38) 1/2 (.50) 2-25/32 (2.79) 2-25/64 (2.39) 61/64 (.95) 15 RV3F46 1/2 ODF (.50) 3/4 ODF (.75) 3/8 (.38) 5/8 (.63) RV3F36 3/8 ODF (.380 3/4 ODF (.75) 5/16 (.31) 5/8 (.63) 3-27/64 (3.42) 3-1/4 (3.25) 1-17/64 (1.27) 20 RV3F46D1* 1/2 ODF (.50) 3/4 ODF (.75) 3/8 (.38) 5/8 (.63) RV3F35 3/8 ODF (.38) 5/8 ODF (.63) 5/16 (.31) 1/2 (.50) RV3F45D1* 1/2 ODF (.50) 5/8 ODF (.63) 3/8 (.38) 1/2 (.500 2-25/32 (2.79) 2-25/64 (2.39) 61/64 (.95) 15 RV3F35D1* 1/2 ODF (.500 5/8 ODF (.63) 3/8 (.38) 1/2 (.500 RV3F36D1* 3/8 ODF (.380 3/4 ODF (.75) 5/16 (.31) 5/8 (.63) 3-27/64 (3.42) 3-1/4 (3.25) 1-1/64 (1.27) 20 RV2 & RV3 P1378A RV4 & RV6 DIMENSIONAL DATA DIMENSIONS SHOWN ARE IN INCHES; FRACTIONS (DECIMALS) TYPE DISCHARGE C1, S, C2 A MIN. B MIN RV456 5/8 ODM (.63) 3/4 ODF (.75) 1/2 (.50) 1/2 (.50) RV4F46 1/2 ODF (.50) 3/4 ODF (.75) 3/8 (.38) 1/2 (.50) RV4F47 1/2 ODF (.50) 7/8 ODF (.88) 3/8 (.38) 7/8 (.88) RV6F46 1/2 ODF (.50) 3/4 ODF (.75) 3/8 (.38) 1/2 (.50) RV6F47 1/2 ODF (.50) 7/8 ODF (.88) 3/8 (.38) 7/8 (.88) RV6F57 5/8 ODF (.63) 7/8 ODF (.88) 1/2 (.50) 7/8 (.88) RV4 & RV6 P1378 639