Canadian Wood Council Fire and Safety Risks Posed by Wood Frame Residential Construction Professor / Fire Chief Len Garis July 15, 2015

Similar documents
What are the Concerns and How Can we Mitigate

Fire Outcomes by General Construction Type A Retrospective Analysis of British Columbia Reported Fires

Smoke Alarm Response Time:

Residential Fire Injury and Death Rates in British Columbia

Sprinkler Systems and Fire Outcomes in Multi-Level Residential Buildings

Assessing the Safety of Smart Meter Installations in British Columbia: Analysis of Residential Structure Fires in BC between July 2010 and June 2017

Assessing the Safety of Smart Meter Installations in British Columbia: Analysis of Residential Structure Fires in BC between July 2010 and June 2016

Establishing the Risk Basis of Building Size Limits

Sprinkler Systems and Residential Structure Fires - Revisited:

Reported Fires in High-Rise Structures in Selected Occupancies with and without Automatic Extinguishing Systems by Extent of Smoke Damage

BENEFITS of RESIDENTIAL FIRE SPRINKLERS:

Structure Fires in Hotels and Motels

Fire Sprinklers Working Group Final Report


Sprinklers in Wood-Frame Construction:

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Steven Craft, PhD, P.Eng. FIRE SAFETY DURING THE COURSE OF CONSTRUCTION

Fire Prevention Education Delivered by OnDuty Fire Fighters

Tampa, FL Fire Cause Classification Task Group Tue, 14 April 2011

CLT Adhesive Tests in Support of Mass Timber Buildings

Community Development and Recreation Committee

PROTECT WHAT YOU VALUE MOST

Study confirms cooking, smoking are top causes of house fires

Copyright 2018 American Wood Council 1

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

NAHB Talking Points to Sprinkler Proponent Reports

( )

The Goals and Objectives of Project FAIL-SAFE

Open to Below: A Discussion of Allowed Floor Openings. Jay A. Ierardi, Ph.D., P.E., LEED AP. Kevin S. Hastings, P.E., LEED AP

Fire Protection Coffee Break Training August 2016


U.S. Fire Department Profile 2015

Frequently Asked Questions

A Review of a White Paper on Residential Fire Sprinklers

Where There s Smoke, There s Fire. And, too often, they. Non-Combustible Concrete Construction. Life Safety for Multi-Family Homes

FM Approval Standard For Cavity Walls And Rainscreens

Smoke Alarms Work, But Not Forever

THE SMOKING-MATERIAL FIRE PROBLEM

VICTORIA BC V8R 1C4. # of Occupants (At time of fire): 30 # of Injured: 0 # of Deaths: 0 Total Dollar Loss Estimate:

SELECTIONS FROM HOME COOKING FIRE PATTERNS AND TRENDS CHARCOAL GRILLS

COST-EFFECTIVE FIRE-SAFETY RETROFITS FOR CANADIAN GOVERNMENT OFFICE BUILDINGS

Understanding and Managing Fire Safety in Housing Accommodation

U.S. STRUCTURE FIRES IN OFFICE PROPERTIES

Steven Winter Associates, Inc. J827

Fire Department Fire Prevention Inspection Services. HIGH RISE STRUCTURE Fire Inspection Program

Fire Investigation

PATTERNS OF FIREFIGHTER FIREGROUND INJURIES

How design fires can be used in fire hazard analysis

Branch Fire Rescue Services

Estimating Fires When a Product is the Primary Fuel But Not the First Fuel, With an Application to Upholstered Furniture

TABLE OF CONTENTS ADOPTED FIRE CODES... 3 AFPD SERVICE AREA... 3 SITE AND DEVELOPMENT SUBMITTAL REQUIREMENTS... 4 PLAN REVIEW FEES...

Draft Document. A 15 Year Update on the Impact and Effectiveness of the Scottsdale Sprinkler Ordinance

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm

ECONOMIC JUSTIFICATION FOR SPRINKLER SYSTEMS

Prereq: FOD 131 or Instructor Permission

U.S. FIRE DEPARTMENT PROFILE THROUGH 2009

VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting

STUDY ISSUE PAPER ON THE RESIDENTIAL SPRINKLER ORDINANCE

Merging safely: addressing blind spots to fire hazards in the proposed framework for the legalization and regulation of Cannabis

NFPA Talking Points on NFPA 1 Fire Code update to the 2015 Edition:

STRUCTURE FIRES IN EDUCATIONAL PROPERTIES

Development of an Environmental and Economic Assessment Tool (Enveco Tool) Francine Amon, Jonatan Gehandler, Selim Stahl

Fire Flow Requirements Standard

Common Building Code Misinterpretations

Fire Flow Requirements Standard

Residential Structure Fire Deaths in BC, BC Coroners Service Ministry of Justice

FIRE FATALITY 2016 REPORT HI T

Site Plans. Fire Code Requirements

DISTRICT OF PORT HARDY BYLAW A BYLAW TO ESTABLISH AND REGULATE THE DISTRICT OF PORT HARDY FIRE DEPARTMENT

Nightclub Fires in 2000

BUSINESS PLAN: Fire Prevention & Education

Onsite Fire Risk Reduction Methods

Community Risk Based Inspection & Enforcement Program

BUILDING INSPECTION SAFETY PROGRAM MANUAL CHAPTER 5, REFERENCE # 1.4 August 1, 2009 OUT OF SERVICE (OOS) SPRINKLER AND STANDPIPE SYSTEMS

DOMESTIC SMOKE ALARMS AND SPRINKLERS. Introduction. Materials and methods. Frank SWANN 1. Legislative impact. Review article

CHARACTERISTICS OF HOME FIRE VICTIMS

Heating Fires in Residential Buildings

Questions related to specific materials, methods, and services will be addressed at the conclusion of the presentation.

Home Fires Involving Heating Equipment

Practice Advisory 18: Fire safety design for tall buildings

Fire Inspector and Investigators Career Path Exploration. Angela Gervais and Edward J. Lazaros. Ball State University

Performance of Smoke Detectors and Sprinklers in Residential and Health-Care Occupancies

BUILDING CODE COMMISSION

SOUTHERN NAZARENE UNIVERSITY 2016 FIRE SAFETY REPORT

Preview of the MA Building Code (780 CMR) 9 th edition

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

Impact of Minimum Fan Efficiency Grade. Dr. John Cermak Executive Vice President ACME Engineering and Manufacturing Corp.

FIRE APPARATUS ACCESS

In addition, Fire Protection and Business Support Information are included in the report.

4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour.

Advisory Brief to Prince George City Council On the Matter of Bylaw 8727, 2013, Fire Protection and Emergency Response Bylaw

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

Exploring Career Alternatives Engineering & Applied Science Technology through ASTTBC

Unwanted Fire Alarms. Marty Ahrens National Fire Protection Association 1 Batterymarch Park Quincy, MA (617)

COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE

Compliance with Lighting Standards and Management Systems (ANSI C137)

District of Sicamous. Fire Department Bylaw No. 126, Effective Date February 26, 1996

WASHINGTON STATE PATROL

FIRE APPARATUS ACCESS AND WATER SUPPLY GUIDELINE

Transcription:

Canadian Wood Council Fire and Safety Risks Posed by Wood Frame Residential Construction Professor / Fire Chief Len Garis July 15, 2015

Credit(s) earned on completion of this course will be reported to AIA CES for AIA members. Certificates of Completion for both AIA members and non-aia members are available upon request. This course is registered with AIA CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation.

Course Description Len Garis, the Fire Chief for the City of Surrey, Professor at the University of the Fraser Valley, Affiliated Research Faculty, John Jay College of Criminal Justice, New York, will discuss research undertaken in partnership with Dr. Joe Clare and will examine stakeholder concerns with the fire and safety risks posed by wood frame residential construction. The talk will commence by discussing the background to the concerns from the fire service with respect to these structures, and how these contrast with the benefits that have been identified for these buildings. The specific nature of the concerns that have been raised by the key stakeholders will be outlined and then discussed with respect to research findings that have examined these issues, including an overview of the National Research Council work that has contributed to the safety margins relied on in the new building codes, and a retrospective analysis of recent fire outcomes for relevant structures in BC. Vulnerabilities with previous constructions that have been identified will be discussed, along with an explanation as to how the amended building code addresses these. The talk will conclude by explaining that, based on available simulation and retrospective data, and acknowledging the amendments that have been made to the building code to protect these new, taller wood frame buildings, there does not appear to be data-driven support for the concerns raised by key stakeholders with respect to these structures. In addition, the rate-of-return on the increasing demands for fire protection relative to the reduction in fire losses will be explained, with the intent of demonstrating that the ever-growing total cost of fire requires all stakeholders to be more mindful of adding additional costly safety components without considering their effectiveness. Len Garis is the Fire Chief for the City of Surrey, BC and is an Adjunct Professor in the School of Criminology and Criminal Justice at the University of the Fraser Valley, Affiliated Research Faculty, John Jay College of Criminal Justice, New York and a member of the Institute of Canadian Urban Research Studies, Simon Fraser University. Contact him at Len.Garis@ufv.ca.

Learning Objectives At the end of the this course, participants will be able to: The specific nature of the concerns that have been raised by the key stakeholders will be outlined and then discussed with respect to research findings that have examined these issues, including an overview of the National Research Council work that has contributed to the safety margins relied on in the new building codes, and a retrospective analysis of recent fire outcomes for relevant structures in BC. Vulnerabilities with previous constructions that have been identified will be discussed, along with an explanation as to how the amended building code addresses these. The talk will conclude by explaining that, based on available simulation and retrospective data, and acknowledging the amendments that have been made to the building code to protect these new, taller wood frame buildings, there does not appear to be data-driven support for the concerns raised by key stakeholders with respect to these structures. discussing the background to the concerns from the fire service with respect to these structures, and how these contrast with the benefits that have been identified for these buildings. the rate-of-return on the increasing demands for fire protection relative to the reduction in fire losses will be explained, with the intent of demonstrating that the ever-growing total cost of fire requires all stakeholders to be more mindful of adding additional costly safety components without considering their effectiveness.

This concludes The American Institute of Architects Continuing Education Systems Course Canadian Wood Council Wood WORKS! Alberta www.cwc.ca www.wood-works.org

Fire and Safety Risks Posed by Large Wood Frame Residential An Evidenced Based Review What are the stated concerns and what does the data show? Wood Works Canada July 15, 2015 Len Garis Fire Chief City of Surrey, BC Adjunct Professor University of the Fraser Valley Affiliated Research Faculty John Jay College of Criminal Justice, New York 6

Large Wood Frame Residential L 7

Challenging the Implicit Assumption The instinctive response from the fire service with respect to 6-storey wood frame buildings 50% taller Therefore 50% more risk for fire and safety L 8

Three Takes on Wood Frame Construction Developers Public Fire service L 9

1. What the Developer Sees L 10

2. What the Public Sees L 11

3. What the Fire Service Sees L 12

Understanding the Benefits Increase demand for local wood products Create jobs and stimulate the economy Increase housing affordability 12% - 15% Lower carbon foot print More intensive land use L 13

Fire Service Concerns Raised Science Expressed lack of research and/or evidence to support Harmonization Not consistent with other building codes Consultation Stakeholders outline a number of issues Response times Resourcing Inspections Construction site safety L 14

Code Changes in BC 2009 Compartmentalization Fire resistant assemblies More stringent sprinkler protection Control of moisture content Construction risk mitigation L 15

Research Relating to these Concerns 1. National Research Council simulation modeling 2. Retrospective analysis of fires in BC 3. Case studies from other jurisdictions that have these buildings 4. Shake-table research examining earthquake impacts J 16

FiRECAM TM Sprinkler Study #1 Two variables of interest Civilian / Firefighter Injuries Sprinkler protection Additional fire departments 17

Civilian / Firefighter injuries N = (9,841 Fires / 144 Deaths / 696 Injuries ) 18

FiRECAM TM Sprinkler Study #1 Sprinklers always better life safety, regardless of response time 19

Research Part 1 NRC Modeling Fire Separations, Calculated the relative expected risk to life and expected losses for five different options: 1. 60-min wall/flooring/ceiling assembly without sprinklers 2. 60-min wall/flooring/ceiling assembly with sprinklers 3. 45-min wall/flooring/ceiling assembly with sprinklers 4. 60-min wall and 45-min floor/ceiling assembly with sprinklers 5. 30-min wall/flooring/ceiling assembly with sprinklers Sprinklers modeled at NFPA13R J 20

FiRECAM TM Sprinkler Study #1 The only option without sprinklers Fire resistance ratings make no difference J 21

FiRECAM TM Sprinkler Study #1 The only option without sprinklers Fire resistance ratings make no difference J 22

Research Part 2 BC Data Set of 1,942 fire incidents that occurred in apartments Occurred in BC October 2006 to October 2011 Compared fires in completely sprinkler protected buildings (n = 565) With fires in buildings without any sprinkler protection (n = 1,377) Looked at Initial detection Extent of fire spread Method of fire control J 23

Method of Fire Control by Sprinkler Status Multiple-hose lines also required less often J 24

Extent of Fire Spread by Sprinkler Status Fires controlled by sprinklers never extended beyond the floor of origin 96.2% contained to the room 12.7% of fires in buildings without sprinkler protection spread the building and beyond J 25

Timing of Fire Safety Inspections Set of 4,084 fire incidents that occurred in inspectable properties Occurred in BC 1999 to 2003 (when inspection form changed) Examined date since last inspection (more or less than 1 year) and fire outcome Property loss Fire-related casualty J 26

Timing of Fire Safety Inspections Majority of fires (74%), injuries (81%), and deaths (74%) occurred within 1 year of most recent inspection No meaningful increase in risk with duration since last inspection Timing had no influence on extent of fire spread Buildings inspected at least every 3 years performed equivalently J Injury rates were greater for residential vs. nonresidential properties No influence of timing that indicated increased risk with increased time 27

Research Part 3 Case Studies Seattle Fire Service, WA Protects an area that has had 6-storey multi-residential wood frame buildings for 20 years Deputy Fire Chief Fire Marshal We have been allowing this in Seattle for roughly 20 years and although we may have hundreds of buildings like this we have not seen large losses Seattle Battalion Chief The fires I have had in these buildings have been controlled by sprinklers and confined to the room of origin The Seattle Fire Department mandates fast response residential sprinklers in these kinds of occupancies and they are very effective J 28

Research Part 4 Shake Tables van de Lindt et al. examined the outcomes of controlled, shake-table research Examine structural performance of wood frame buildings in response to extreme seismic activity Full-scale mid-rise light-frame 6 story apartment model World s largest shake table, in Miki, Japan 1,350 m 2 of living space with 23 apartment units Exposed to once in every 72 years events to once in every 2,500 years events (equated to the 1994 LA earthquake) J 29

Research Part 4 Shake Tables J 30

Research Part 4 Shake Tables Overall, the researchers concluded The buildings performed excellently under simulation conditions Sustained little damage across all trials It is estimated that only 2 of Japan s 500 wooden pagodas some as tall as 19 stories have collapsed during the past 1,400 years Despite being one of the world s most active earthquake zones The Economist (1997) J 31

Vulnerability #1 External Origin Fires Fires that commence on the outside of the building: Exterior balconies Court/patio/terrace area J 32

Analyzing the Risk with Balcony Fires Set of 2,638 fire incidents that occurred in apartments/ townhomes Occurred in BC October 2006 to October 2011 Initially looked at sprinkler protection status not predictive Compared fires that started on balconies and court/patio/terrace (n = 255) With all other apartment/townhome fires (n = 2,383) Looked at Initial detection Extent of fire spread Method of fire control J 33

Initial Detection for Balcony Fires 1.4 times more 5.5 times less J 34

Extent of Fire Spread for Balcony Fires 2.2 times more likely to extend to the building and beyond J 35

Method of Fire Control for Balcony Fires 3.3 times less likley burn out 1.5 times more likely required fire dept water J 36

Vulnerability #2 Buildings Under Construction L 37

What Causes Fires when Under Construction? Leading causes for fires when under construction: Incendiary / suspicious events Smoking on site Open flames/ embers Heating equipment L 38

Construction Fire Safety Plans L 39

Construction Fire Safety Plans Fire safety plan requirements: Fire safety training for onsite staff Enforcement of best practices Features co-ordination fire wall construction fire doors Site security active watchman service L 40

Construction Fire Safety Education http://cjr.ufv.ca/ L 41

L How Much does Protection Fire Cost?

What s Driving the Total Cost of Fire The most recent estimates for the total cost of fire in the US was produced by Hall in 2010. Economic loss (property damage) due to fire (direct and indirect, reported and unreported) estimated at $18.6 billion 13% decrease compared to 1980 estimates (CPI adjusted) L 43

Summarizing the Trends for Cost of Fire 13% decrease J.R. Hall Jr., The total cost of fire in the United States, 2012, National Fire Protection Association, Fire Analysis and Research Division: Qunicy, MA. p. 31. 44

Summarizing the Trends for Cost of Fire 156% increase L J.R. Hall Jr., The total cost of fire in the United States, 2012, National Fire Protection Association, Fire Analysis and Research Division: Qunicy, MA. p. 31. 45

Summarizing the Trends for Cost of Fire 130% increase L J.R. Hall Jr., The total cost of fire in the United States, 2012, National Fire Protection Association, Fire Analysis and Research Division: Qunicy, MA. p. 31. 46

At What Cost Was the 13% Decrease? 156% increase in the cost of career fire department 67% increase in the net difference between firerelated insurance premiums paid and estimated insurable economic losses 130% increase in the costs of new building construction for fire protection These building construction costs include passive protection, such as compartmentation, and active protection, such as detection and sprinkler systems L 47

Hall discusses that these trends clearly indicate there is a need for product innovations and other programs (including education) that can simultaneously improve fire safety but at a lower cost. 48

Extensive examination Conclusions Simulation, retrospective quantitative analysis, case study Overwhelmingly consistent theme that emerges Although fire services typically have responded to these types of proposed changes with concerns Available information suggests these structures will perform at least as well from a safety perspective as those that are already permitted Existing code changes make provisions to address the weaknesses for Buildings while under construction. Fires that originate from the exteriors of these buildings (most typically from balconies). J 49

The Future? 20 - L

Is the FUTURE going to be Safe? The best available data so far says Yes No difference between the Two construction materials L Source: Richardson (2007) Fire and Materials, 31, 97-123 51

Does Construction Type make a difference? We reviewed 34,708 reported fires in British Columbia October 2008 to October 2013 11,875 were retained for subsequent analysis There were 772 injuries and 107 deaths Looked at fires that occurred in the following five construction types: Combustible construction open wood joist Protected combustible construction wood protected by plaster/gyproc Heavy Timber construction Non-combustible construction exposed steel Protected non-combustible construction - protected steel or concrete J 52

Does Construction Type make a difference? Looking at ( n = 11,875 ) Frequency of fires, deaths and injuries by general construction type Extent of fire spread by general construction type Frequencies of fires, sprinkler protection, smoke alarm activation and injury rate general construction type Extent of fire spread by general construction type and protection type Method of fire control by general construction type Fire related causalities by general construction type Fire Related causalities by construction type in the presence of a working smoke alarm and sprinkler protected J 53

Does Construction Type make a difference? Conclusion We found causalities by construction type in the presence of a working smoke alarm and sprinkler protected Had no deaths across all construction types Had an Injury rates that was similar The fires spread were remarkable similar with no distinguishable differences by construction type, most fires were confined to the room of origin. J 54

Does Construction Type make a difference? J 55

Does Construction Type make a difference? No Deaths Protected Combustible Injury Rate 63 / 1,000 Non - Combustible Injury Rate 53 / 1,000 J 56

Not Just Talking About Smoke Alarms US Fire Administration research (2008) Fire sprinklers alone chances of dying in a fire decrease by 69% (compared to no sprinklers) Smoke alarms alone chances decrease by 63% (compared to no alarm) Sprinklers AND smoke alarms chances decrease by 82% Fire risk is non-random Not advocating for blanket approaches more thoughtful and risk driven L 57

Building Taller From Wood Italy 20 - L

Questions/ Comments? Len.Garis@ufv.ca Surrey Fire Service (604) 543-6701