Zone controller System ZC207DK INSTALLATION INSTRUCTIONS

Similar documents
PDD-FT-3. Fire Panel Interface With EOL Trigger. Installation and Specifications Manual

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

02/11/2015

ORION-PL Poultry computer for cage houses

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

CD-Px Series Duct Mount CO 2 Transmitters

EBMHS (standard & slim-line PSU)

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

TEC3000 Series Stand-Alone and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Premier 2-Zone Controller model Installer Guide

Flush-mounted room thermostat

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Switching power supply. Additional Information on page 2 Input rating: Vac, 50-60Hz, 2.5A Output rating: 24Vdc, 8.33A max., 200W max.

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

PolyGard 2-channel Gas Controller MGC-03

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

VA301C CONTROLLER WITH BACnet OPTION

Smart ways to save energy IntelliCon INSTALLATION MANUAL

Smoke Control Listed LCM-OAVS VAV with HW Reheat, Two Venturi Air Valves (One Exhaust, One Supply) including BTU Compensation

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

ADC-T2000. Smart Thermostat v1.5

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

Snifter ATEX22 VERSION. User Manual. Distributor

Instructions for the fan motor control system with integrated wiring terminals SILVER C

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Power Supply Display Module PSDM. Installation and Operation Manual

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Illuminated Stopper Station Push Button

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

RE-PR3-E-27 3-Phase Panel Mount 27kW

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

Room thermostat with 24-hour time switch and large LCD

Technical. Catalogue. NA Version PDWL AECM. LSTAT Series Hydronic EC Ducted Fan Coil

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

02/11/2015

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

AR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Across-the-Line SERIES MP300 Combined Manual and Automatic

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

ET10 Series Stand-alone LCD Fan Coil Thermostat

Variable Frequency Drive SERIES MP800 VFD

Door Release Power Supply

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Pre-programmed room controller with communication and hidden setpoint

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

ELECTRONIC HUMIDISTAT: H270

APPLICATION DATA SHEET

FO-FDHB6-1 Central Heat Blower Kit

RMS/RPX Reader. User Manual

R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description

Foot control. No instrument selected. A Raise chair Chair to working position 1 B Incline backrest Chair to spitting. positioning

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

AL800ULADA. NAC Power Extender. Installation Guide

Dräger Polytron 8310 Stationary gas detector (DSIR)

Instructions for the fan motor control system, SILVER C

DQ15D/ T-DQ15D Instruction Manual

ELECTRONIC HUMIDISTAT: H200

TEC2100 Series Networked Thermostats

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

CP CP

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

INSTALLATION AND OPERATING INSTRUCTIONS

Soft Start Series MP700 Solid State, Reduced Voltage

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

Booster Power Supply Manual

Water Source Heat Pump Module Technical Guide

Emotron M10 Shaft Power Monitor. Instruction manual English

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

Model A1600 Series Annunciator

TOSHIBA AIR CONDITIONING

24 VAC Intermittent Pilot Gas Ignition Control

PSN-1000 & PSN 1000(E) Installation Manual

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

I/O ZONE 560/583 AND OPERATION MANUAL

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

PH:

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

DIGITAL LIGHT CONTROLLER

Dräger Polytron 8100 EC Detection of toxic gases and vapors

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Transcription:

Indication Panel Diagnostic. Power - The Green LED is ON when Power is supplied to the controller. K1 - LED is ON when the relay K1 is close. Operates the Acu. K2 - LED is ON when the relay K2 is close. Operates the Acu. By-Pass When LED is ON the By Pass is operating. When LED is OFF the By Pass is NOT operating. When LED is blinking, the by pass has some fault situation. Ch#1 to Ch#7 When LED is ON the damper at Ch#1 is operating. When LED is OFF the damper at Ch#1 is NOT operating. When LED is blinking, the damper at Ch#1 has some fault situation. Zone controller System ZC207DK INSTALLATION INSTRUCTIONS ZC207DK Indication Panel Diagnostic. Power - Le LED vert est allumé quand la carte est sous tension par l'intermédiaire du transformateur. K1 - Le LED rouge est allumé quand le relai K1 is fermé. Operates the Acu. K2 - Le LED rouge est allumé quand le relai K1 is fermé. Operates the Acu. By-Pass Quand le LED est allumé, le By Pass est en fonction. Quand le LED est éteint, le By Pass n' est pas en fonction. Quand le LED clignote, le by pass a un défaut de fonctionnement Ch#1 à Ch#7 Quand le LED est allumé, le clapet branché sur le canal Ch#1 fonctionne. Quand le LED est éteind, le clapet branché sur le canal Ch#1 n'est pas en fonction. Quand le LED clignote, le clapet branché sur le canal Ch#1 a un défaut de fonctionnement. 22ºc 19ºc 18ºc 20ºc 21ºc O.L.Art Design 21ºc 19ºc

Zone controller System ZC207DK Twitoplast Ltd. Thank you for purchasing the most advanced Zone systems the ZC-207 DK. ZC207DK is a dry contact controller designed to control up to 7 rooms (zones) with proportional round air Dampers + proportional By Pass Damper, 2 Relays and communication port. The controller operates the air condition unit (Acu) by two dry contact relays and is not interfering with the Air condition original of the Acu. The Acu will receive commands to operate or shut off automatically, according to the total system demand for cooling or heating. Using our system you can restarted the Acu form each room ( Zone). The controller receives operation commands from each room (zone) and controls the air dampers proportionally. The Twitoplast advanced Zone control system ZC-207 DK can be integrated with any inverter ducted system which will save up to 60% in electricity cost when only one room (Zone) is in open status. Easy and friendly to the installer. Package Content o Opal C207DK P.C.B o C200PS- Power Supply o 12v Cable o 8 Cables / o P3 Motor ( for the By-Pass Damper ) o Instruction Installation Electronic Room ( Zone ) Damper lers. The Opal RC11 handheld remote controller with I/R receiver. The Opal 128DD wall mount room thermostat. The Opal 650DD Flush mount room thermostat. The controllers are Connected to the ZC-207 DK(12V) with pre-fabricated RJ11-4 standard cable supplied by the Manufacturer with the controllers Kit.

! Safety and Warning Instructions The instructions of installation, operation and maintenance are delivered with each controller. Before installation read all the handbooks and get familiar with the elements and operations. Check that the air-conditioner which will be controlled by the controller is ready to be started and compatible with the controller. Before installation, Make sure that all the components are out of power and disconnected. The installation MUST be made ONLY by one qualified professional and in the respect of the directives and the laws in force in the country. The system is built for inside buildings installation ONLY. Keep away the components of the system out of children reach. If the guide line is not well understood is may affect the performances of the system. Relays: One relay controls the Acu There are Two relays on the controller that are operating in opposite to each other. K1 is N.O. and K2 is N.C. (Normally Open and Normally Close). The installer should select the proper relay as per the type of the Acu. ler if it respectively requires N.O or N.C command. Use pre-fabricated cables two wires cables between the ZC207DK and the Acu. board. Supplied by the Acu. Manufacturer that match to his terminals at the Air condition and the other end of the cable to the ZC-207DK on the N.O or N.C relay. EMG = Emergency input The Emergency input will be N.C. contact input and it requires a jumper wire to operate. It is mainly designed for fire systems. In Case of FIRE the Air condition will shut down and All Dampers ( BY-Pass too). to avoid toxicity gas (Smoke) to go through the ducting into the rooms ( zones) For low voltage input only. Use 0.5 mm wire as minimum. Communication port The communication port allows connecting additional controller to the main one. This feature allows connecting up to 14 rooms(zones) to one system with one Power Supply C200PS. The main controller will be the master and the second one will be the slave. The master controller will be the one to control the Acu. Use only prefabricated RJ11-4 standard cables supplied by the Manufacturer.

Dip Sw. Settings: M1 Dip SW. #1 = Defines that at Channel #1 the size of the damper is doubled. Dip Sw. #2 = Define if the K1 relay will have 1 second pulse after power up or not. [For Sanyo units]. Dip Sw. #3 to #8 = Not used. ZC207 CH#1 M2 Indication panel 7 Channel LEDS for each damper status indication. 2 LED's for each relay operation. 1 power LEDS for main power supply. ZC207DK controller: o Made engineering Plastic ABS V-0 o Voltage supply to the Motors dampers 12 VDC o Voltages supply of the Power unit: 240 VAC (205 VAC - 250 VAC), o Conditions operating: 0ºC - 30ºC, between 5% and 95% of relative humidity, without condensation o Conditions of storage: -18 C with 60 C, between 5% and 95% of relative humidity, without condensation o Relative Humidity: 10% - 90% RH o Certificate: EC o Dimensions : 210 mm X 120mm X 55mm of height. Power Supply C200PS The Unit works with 230 Vac. 50/60 Hz. Use 3 wires cable type 250 VAC, 0.5 mm. Built according to CE and UL standards. Dimensions : C200PS: 125 mm X 120 mm X 60 mm. Plastic Body ABS V-0 The ZC207DK must be connected to the C200PS power supply. Use the / pre-fabricated cable supplied by the Manufacturer

By-Pass Damper The By-Pass damper will balance the air flow proportionally to the air flow demand form each room(zone). The damper will be motorized directly from the controller in the room(zone). Connect the By pass motor to the ZC207DK controller using prefabricated / cable supplied by the Manufacturer. Wall Flush Wall Wall Flush Wall 12VAC 12V 12V ZC200PS #1 #2 #3 #4 #5 #6 #7 C_in C_out BY-PASS 12345678 P N Main Power 230 VAC K1 K2 Dry Contact EMG Round Dampers The controller will Motorize the following dampers size 4",6", 8", 10" 12" &14". Each damper will be Motorize by a DC motor. It is possible to multiply the damper size at channel #1. Turn ON Dip SW. #1. Connect the motors to the ZC207DK controller using prefabricated / cable supplied by the Manufacturer. The K1 and K2 relays ratings are: 250 VAC, 2 Amps.