User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

Similar documents
User Manual for model

User Manual for model

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

USERS MANUAL FOR GAS BOILERS

ir-range 8G /03.15 Changes reserved.

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

E-COMBI EVO E-SYSTEM EVO

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

USERS GUIDE 24, 30. For installation guide see reverse of book

USERS GUIDE. LOGIC+ Combi 24, 30, 35

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

Logic+ Combi

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Operation manual. Wall-mounted condensing boiler D2CND024A1AA D2CND024A4AA D2TND012A4AA D2TND018A4AA D2TND024A4AA

E-Combi One E-System ONE

/2010 US/CA

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

INSTRUCTION FOR THE USER THC V E OIL BLU

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

VIESMANN. Operating instructions VITODENS 111-W. for the system user

USER GUIDE LOGIC HEAT H

WHE 2.24 / WHE 2.24 FF

USER'S INFORMATION MANUAL

GB24 & GB30. User Manual

USER'S INFORMATION MANUAL

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

TAHITI CONDENSING KR 55 - KR 85

USER GUIDE VOGUE MAX SYSTEM

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Instructions Manual SHC520X - SHC700X

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

VIESMANN. Operating instructions VITODENS 100-W. for the system user

USER'S INFORMATION MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

Operating instructions

USER MANUAL ACQUAHOME 32 B BLU

DOMESTIC HOT WATER Follow operational sequence

CONTROL CABINET for cascade boiler systems

NR-20DU. Keep this manual near this remote controller for future reference whenever maintenance or service is required.

PROGRAMMABLE 7-DAY THERMOSTAT

The mechatronics of EVE 05

End User Manual ACO 35 MFFI COMBI

24/30/38. E-Combi. CONDENSING WALL HUNG COMBINATION BOILER G.C.N : (24 kw) G.C.N : (30 kw) G.C.N : (38 kw)

USER'S INFORMATION MANUAL

Installation and Servicing Instructions RHA 28. Gas Fired, Condensing Boilers with Storage Cylinder CE 0694 SEDBUK BAND B TG05A062.

Light oil burners. One stage operation

CE 0694 RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

USER'S INFORMATION MANUAL

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

prestige Control Application Supplement - Type 5 MCBA WARNING

GENUS HE GENUS HE 24 GENUS HE 30 GENUS HE 38. User Manual. Condensing wall hung system boiler

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

Operating instructions

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Service & Trouble Shooting Manual

User s Information Manual

IE Instructions and warning book CRONO 7. Weekly digital chronothermostat

INSTALLATION AND MAINTENANCE MANUAL FOR GAS FIRED HEATER

Operating instructions

Operating instructions

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

IST 03 C ANTEA CONDENSING EN INSTALLATION, USE & MAINTENANCE MANUAL

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Operating instructions

Operating instructions

User s Information Manual

USER MANUAL. Cooker Hood ZHG51250GA

ecotec pro Operating instructions Operating instructions For the operator GB, IE Gas-fired wall-hung high-efficiency boiler

CALDAIA MURALE A GAS A CONDENSAZIONE

BeSMART Thermostat. EN Thermostat Manual

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE)

Settings and Maintenance of the CombinAir

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

Installation & User s Instructions

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Operating instructions

Service booklet for the Engineer for Gas Condensing Boilers

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Ciao Green Condensing Wall-Hung Boilers

Transcription:

User Manual for model RBS 24 series ENERGY Wall mounted instantaneous combi boiler room sealed chamber CE 0694 RBS 24 - SERIE ENERGY - RAD - ING - MAN.UT - 1407.1 - DIGITECH TR - MIAH6 - E04 Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

INDEX 1. General warning pagina 1 2. Control Panel pagina 2 3. Starting up the boiler pagina 3 4. INFO Menu pagina 3 5. Boiler functioning modes pagina 4 6. Filling the system pagina 5 7. Diagnostics Error codes pagina 5 8. Switching OFF the boiler pagina 6 9. Frost Protection pagina 6 10. Maintenance pagina 7 11. Recycling pagina 7

BOILER OPERATING INSTRUCTIONS 1. General warning Make sure that the authorised technician who tested the boiler has stamped the guarantee booklet. The installation, first start-up, regulation and maintenance operations must be carried out exclusively by qualified personnel (e.g. Radiant authorised Service Centres). Incorrect installation can cause damage to property and injury to persons or animals, for which the manufacturer will not be held responsible. During the installation, the technician must carry out the following checks: The data on the data plate must correspond to that of the mains supply networks (gas, electricity, water); The boiler must be regulated according to its designed use and performance; The flue gas exhaust and combustion air intake system must be correctly installed and operational; The exhaust gas discharge and ventilation systems must comply with the requirements of national and local standards regardless of whether the boiler is installed indoors, outdoors or in its own cabinet (see section Reference standards ). User general warnings: If there is any doubt as to whether the appliance has been tested by an authorised technician, do not attempt to start it. All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL. Should any part of the boiler freeze-up, do not attempt to light it under any circumstances, but instead call the Service Centre immediately. The appliance s combustion system must be checked every two years. This check includes testing the efficiency of the boiler and must be carried out by authorised personnel possessing the qualifications as required by current law. Do not obstruct the ventilation openings in rooms where there are gas-burning appliances installed (boiler, cooker, etc.) Do not allow the appliance to be used by persons (including children) with reduced physical, sensory, mental capabilities or with lack of experience and knowledge unless they have been viewed or educated on the use of the appliance by the person responsible for its safety or anyone unfamiliar with its operation; The installation, operation and maintenance manual forms an integral and essential part of the product and must be kept near the appliance always. If you smell gas DO NOT ACTIVATE ANY ELECTRIC SWITCHES, TELEPHONES OR ANY OTHER DEVICE THAT MAY GENERATE ELECTRICAL DISCHARGES OR SPARKS. OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY CLEAR THE ROOM. CLOSE ALL GAS TAPS AND VALVES. CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL. 1

2. Control Panel CONTROL PANEL KEY 1. HEATING TEMPERATURE SETTING BUTTONS 2. INFO BUTTON: PRESS ONCE TO DISPLAY TEMPERATURES AND INFO; KEEP IT PRESSED FOR 5 SECONDS (IN OFF MODE) TO DISPLAY THE LAST 5 ERRORS. 3. MODE SELECTION BUTTON: SUMMER ONLY / WINTER ONLY / SUMMER-WINTER / OFF. 4. RESET BUTTON: ERROR RESET FLUE TEST FUNCTION ACTIVATION (CHIMNEY-SWEEPER - KEEP IT PRESSED FOR 7 SECONDS). 5. DOMESTIC HOT WATER TEMPERATURE SETTING BUTTONS. 6. TERMINAL BLOCK FOR EXTERNAL WIRING. 7. LCD DISPLAY. 7 Fig. 1 1 2 3 4 5 6 During the boiler operation the display can show 2 different power levels according to the flame modulation of the boiler (see fig. 2) 50% 100% Fig. 2 2

3. Starting up the boiler Check that the boiler is power supplied and that the gas feed valve, placed at the bottom of the boiler, is open. Switch on the boiler by using MODE SELECTION BUTTON and select the functioning mode required. 4. INFO Menu Press the INFO Button to display the boiler data. Once pressed, the parameter number will appear on the left side of the display and the associated parameter value will appear on the centre of the display. Use and buttons of Heating Temperature setting to scroll the list of available data. Press the INFO button to exit the display mode. The list of available display data is the following: Parameter Description d00 d01 d02 d03 D.H.W temperature sensor Outdoor temperature sensor Kd Thermoregulation value Low temperature circuit sensor (only with Zone PCB connected) 3

5. Boiler functioning modes SUMMER mode To switch boiler operation to SUMMER mode, press the MODE SELECTION button ( 3 fig. 1); The boiler will only work for the D.H.W system, the heating system is disabled. The SUMMER mode setting of the boiler is signalled by the symbol, lit continuously on the control panel. The automatic ignition system will light the burner every time there is a domestic hot water demand. In this case, the symbol will flash on the control panel. WINTER mode To switch boiler operation to WINTER mode, press the MODE SELECTION button ( 3 fig. 1); The boiler will only work for the Heating system. The WINTER mode setting of the boiler is signalled by the symbol lit continuously on the control panel. The automatic ignition system will light the burner every time there is a room heating demand. In this case, the symbol will flash on the control panel. SUMMER-WINTER mode To switch boiler operation to SUMMER-WINTER mode, press the MODE SELECTION button ( 3 fig. 1); The boiler will work for both central heating/d.h.w systems. The SUMMER-WINTER mode setting of the boiler is signalled by symbols lit continuously on the control panel. The automatic ignition system will light the burner every time there is a room heating or domestic hot water demand. The functioning is signalled by the symbols flashing continuously on the control panel. Regulating the heating temperature The heating temperature is regulated by using and buttons of Heating temperature setting ( 1 fig. 1): Pressing button, reduces the temperature. Pressing button, increases the temperature. The range of temperature settings for the central heating runs from a minimum of 30 C to a maximum of 80 C (25 C 45 C for under floor heating systems). Regulating the D.H.W temperature The D.H.W temperature is regulated by using and buttons of D.H.W temperature setting ( 5 fig. 1): Pressing button, reduces the temperature. Pressing button, increases the temperature. The range of temperature settings for the D.H.W temperature runs from a minimum of 35 C to a maximum of 60 C. 4

6. Filling the system In order to restore the water pressure of the system, open the filling tap R (fig. 2) and check by means of a pressure gauge M, that the pressure of the system reaches the middle part of the green zone (which corresponds to 1,2 bar, see fig. 3). On completion, close the filling tap R (fig.2). 7. Diagnostics Error codes This paragraph contains a list of error codes that the boiler may generate on the display together with the relative indications and the operations that the user can carry out to reset the boiler. 2 R M Code E01 Ionisation malfunction Check that the gas valve on the boiler and gas meter are open. and that there is gas in the mains supply. Press Reset button reset the error; on the control panel to When the error code on the display disappears, the boiler will restart automatically. If the problem persists, Call the Service Centre. 3 1.5 bar 1.2 bar 0.5 bar GREEN AREA 3 bar Code E02 Safety Thermostat tripped. Press Reset button on the control panel to reset the error; When the error code on the display disappears, the boiler will restart automatically. If the problem persists, Call the Service Centre. Code E03 Air Pressure Switch Tripped. Call the Service Centre. Code E04 Water Pressure Switch Tripped ( ). Check the water pressure in the central heating circuit. The reading on the pressure gauge M (see fig. 2), located on the lower part of the boiler, must not be less than 1,2 bar. If the pressure is less than 1,2 bar, top-up the system as described in paragraph Filling the system. When the error code on the display disappears, the boiler will restart automatically. If the problem persists, Call the Service Centre. Code E05 Heating Sensor malfunction. Call the Service Centre. Code E06 D.H.W sensor malfunction. Call the Service Centre. 5

Code E18 Inadequate circulation. Call the Service Centre. Code E21 General malfunction inside the printed circuit board. Switch off the power supply at the main switch and then switch it on again; When the error code on the display disappears, the boiler will restart automatically. If the problem persists, Call the Service Centre. Code E22 Parameter programming request. Switch off the power supply at the main switch and then switch it on again; When the error code on the display disappears, the boiler will restart automatically. If the problem persists, Call the Service Centre. Code E35 Flame detection malfunction. Press Reset button on the control panel to reset the error; When the error code on the display disappears, the boiler will restart automatically. If the problem persists, Call the Service Centre. Code E40 Electric power supply out of the operation range. Call the Service Centre. Code F08 Frost protection function (central heating circuit) ON. Wait for the completion of the operation. 8. Switching OFF the boiler To switch the boiler OFF, press INFO button, the word OFF appears on the display. The central heating frost protection system remains enabled. If the boiler was previously ON, it is switched OFF and the fan overrun and pump overrun functions are enabled. N.B. If the boiler is to be left unused for a long period of time, the user must do one of the following: Make the boiler safe by disconnecting all the power supplies (electricity and gas), and draining the heating system; Leave the boiler in standby, leaving the electricity and gas supplies connected and, consequently the frost protection function. 9. Frost Protection The boiler is protected from freezing by electronic board settings and special functions that provide the starting of the burner to heat all the interested parts, when their temperature drops below the minimum preset values. This function is enabled if: the boiler is electrically power supplied; the gas supply is open; the system pressure is that required; the boiler is not locked out. In case of boiler parts locked out because of freezing, do not switch the boiler ON and immediately call the Service Centre. 6

10. Maintenance In order to ensure that the boiler operates efficiently and safely, it is recommended that the appliance is inspected by a suitably competent technician at least once a year. A regular maintenance is always source in management system savings. 11. Recycling The appliance packaging is mainly made of recyclable materials. The appliance and all its accessories must be disposed of appropriately differentiated in compliance with the relevant standards. The symbol indicates the inability to dispose of this product as domestic waste. The correct disposal of this product will help to prevent potential negative consequences for the environment and people health. 7

RADIANT BRUCIATORI s.p.a. Via Pantanelli, 164/166-61025 Loc. Montelabbate (PU) Tel. +39 0721 9079.1 fax. +39 0721 9079279 e-mail: info@radiant Internet: http://www.radiant.it THE TECHNICAL DATA AND MEASUREMENTS ARE PROVIDED FOR INFORMATION PURPOSES ONLY AND ARE NOT BINDING. THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION. NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION ERRORS. E+OEALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED, MEMORISED IN ANY FILING SYSTEMS OR TRANSMITTED IN ANY FORM WHATSOEVER, INCLUDING ELECTRONIC, MECHANICAL, PHOTOCOPIES, RECORDINGS OR ANY OTHER MEANS WITHOUT THE COMPANY S PRIOR WRITTEN APPROVAL.