Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Similar documents
Model /8300CRP-8309CRP Shower & Eye/Face Wash

Model Combination Shower Eye/Face Wash

Model /8320CRP Shower and Eye/Face Wash

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Model 7656WCC Eye/face Wash

Model 8356WCC Pull-Down Shower Eye/Face Wash

Model 1011/1011HPS Drinking Fountain

Model TWBS.EW.H Tempered Water Blending System

Model 9001, Alarm

Model 9001, Alarm

Model 9201EFE Tempered Water Blending System

Model 9201EW Tempered Water Blending System

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model TWBS.SHE Tempered Water Blending System

Model 7611 Eye/Face Wash

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

Model 7500EB Portable Eyewash with Heater

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model H1011.8/H1011.8HPS Water Cooler

Model 1900 Retrofit Bottle Filler

3121FR Pedestal Mounted Drinking Fountain

Model 7603BL/7603BL240 Heated Blanket for 7603 Portable Eyewash

INSTALLATION & TESTING MANUAL

Model 7603/7603T/7603T240 Portable Eyewash / Portable Eyewash with Heater

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

H Barrier-Free Wall Mounted Electric Drinking Fountain

INSTALLATION & TESTING MANUAL

H1011.8HPS Barrier-Free Wall Mounted Electric Drinking Fountain

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

H Barrier-Free Wall Mounted Electric Drinking Fountain

Model 1920/1920HPS/1920W Bottle Filler

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

8317CTFP AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER Freeze Resistant

EMERGENCY DRENCH SHOWER

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

model1117l with1920 ADA Compliant Dual Wall-Mount Fountain and Bottle Filler FEATURES & BENEFITS MODEL CHOICES OPTIONS SPECIFICATIONS

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

ADA Compliant Wall-Mount Fountain and Bottle Filler

Flat Line Spray Systems Kits

TUB AND SHOWER FAUCET

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

TUB AND SHOWER FAUCET

Installation Instructions / Warranty. Metris 31060XX XX XX1

SPEAKMAN SPEAKMAN SPECIFICATIONS

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Installation Instructions / Warranty

Installation & Operation Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

TITAN FLOW CONTROL, INC.

Acrylic Claw Foot Tub

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

Installation Instructions / Warranty

Installation & Operation Manual

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

Heater Installation Kit

Gas Connector Installation Instructions

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

2001 Smith Eastern Corporation

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Installation and Owners manual

Installation Instructions / Warranty. Hansgrohe Single Control Kitchen Mixers

Corrosion Resistant Fluid and Air Handling Systems.

MERIDIAN MODEL# 3793

Installation Instructions / Warranty

Installation Instructions / Warranty. Starck 10111XX XX XX1

ENCLOSED UNIT TECHNICAL MANUAL Items # &

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

Installation Instructions / Warranty

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

Installation Instructions / Warranty

Installation Instructions PP-AS20 Anti-Scale System

MOJAVE. Mojave ShowerSpa Model #1016 Owner's Manual

Operation, Maintenance and Installation Manual

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

1PIECE FREESTANDING BATHTUB

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual


Model 53 Macerator Pump Installation, Operation, Repair Manual

BIR Showerhead Installation and User Guide

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

INSTALLATION INSTRUCTIONS. Cubix Widespread Faucet Part #: 3204, 5204, 3304, 5304 HANDLE STYLES

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Flipside Handshower and Showerhead Installation and User Guide

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

Installation & Operation Manual

Nachi Series TM Z6957-XL

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Installation and Owners manual

Desiccant Air Drying System

Kallista Bath Flip Drain

Transcription:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 8330 Stainless Steel Combination Shower Eye/Face Wash No. 2080174(25) NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale. The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries. NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS. SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL: TECHNICAL SUPPORT: 1-800-766-5612 FOR CUSTOMER SERVICE: 1-888-640-4297 10/17 Model 8330 Page 1 of 5

LOCATION OF UNIT: The Model 8330 Stainless Steel combination Shower Eye/Face Wash should be installed in close proximity to potential accident areas. It should be clearly identified, free from obstructions and easy to access. SUPPLY LINE: The minimum recommended line size is 1-1/4 IPS with 30-90 psi (2-6 ATM) flowing pressure. Where sediment or mineral content is a problem, an inlet filter is recommended. PLUMBING CONNECTIONS: Inlet supply is female 1-1/4 IPS. Waste outlet is female 1-1/4 IPS. INSTALLATION PROCEDURE Refer to Installation Drawing for clarification. Check parts list to insure all required parts are included. Use pipe joint sealant PST #567 (Loctite) on all connections. STEP 1: STEP 2: STEP 3: STEP 4: STEP 5: STEP 6: STEP 7: STEP 8: Prepare the emergency shower foundation by using the floor flange as a template. Locate the three holes for the 3/8-16 UNC x 6 anchor bolts. (Not supplied). They should extend 1 above the floor level. Once the concrete foundation is ready (dry), assemble the floor flange to the anchor bolts; then securely fasten with 3/8-16 UNC Hex nuts and 3/8 washers (Not supplied). Seal and tighten floor flange and (1-1/4 ) tee making certain the waste tee is facing the proper location and the foot control holes are facing side to side. Assemble nipple (1-1/4 x 24 ) to the tee and tighten with a pipe wrench. Assemble the eye/face wash loop assembly to the (24 ) nipple from Step three. Connect the pipe wrench to the nipple between the two tees to avoid damage. Assemble in the following order: Attach nipple (1-1/4 x 24 ) onto the loop assembly. Attach nipple (1-1/4 x 24 ) onto the tee. Attach tee (1-1/4 x 1-1/4 x 1 ) onto nipple. Attach nipple (1 x 8 ) and valve assembly onto tee. Attach street elbow (1 ) and nipple (1 x 12-1/2 ) onto valve. Assemble showerhead onto street elbow (1 ). If necessary, use Dow Corning 832 sealant placing 5 small beads on the male threads, just above the first thread. Assemble the sign onto the unit. Use the strap, screws, washers and nuts provided to mount the sign onto the upright. The sign should be positioned for maximum visibility. Insert the plug into the optional supply line tee that is not used. Before connecting the supply water line to the emergency shower; FLUSH THE LINE THOROUGHLY. 10/17 Model 8330 Page 2 of 5

PROBLEM TROUBLESHOOTING REPAIR CHECKLIST 1. No flow. 1. Check the main shut-off valve. 2. Insufficient water flow. 2. Verify minimum 30 psi (2 ATM) flowing supply line pressure. 3. Insufficient water flow on eye/face wash, however, shower is sufficient. 4. Eye/face wash streams do not meet desired eye level. 3. a. Verify minimum 30 psi (2 ATM) flowing supply line pressure. b. Probable clogging of flow control due to inadequate line flushing. Unscrew eye/face wash head and remove the four screws to disassemble head. Clean flow control and reassemble head. c. Remove plug located on L Strainer using a 9/16 wrench to access and clean filter screen. 4. Possible blocked flow control, see above solution. Possible non-leveled eye/face wash assembly. 5. Water does not drain properly. 5. Check your drain system for debris. Check the main waste line of your building to see if it does handle the capacity required for the entire drainage system. 6. Water leak between joints or fittings. 7. Insufficient water flow from shower, however, eye/face wash is sufficient. 6. Tighten loose connections. If leak persists, the application of hot water will sometimes reseat improperly applied joint compound. After 30 minutes wait and retest. A persistent leak will necessitate reassembly and additional sealant. 7. Probable clogging of flow control inside showerhead. Unscrew showerhead off of elbow and clean rubber flow control. For more information about Haws products, see our website: www.hawsco.com 2017 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 10/17 Model 8330 Page 3 of 5

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. PARTS BREAKDOWN 2 7 OPTIONAL OPTIONAL ITEM 1 2 3 DESCRIPTION SHOWER HEAD VALVE ASSEMBLY PULL ROD EYE/FACE WASH HEAD VALVE ASSEMBLY STRIPE TAPE SHOWER SIGN BOWL FOOT TREADLE TEST TAG PART NO. SP829SS SP265 SP200 SP65SS SP228 SP185 SP178 SP90 SP220SS SP170 4 5 6 7 8 9 10 11 L-STRAINER SP509SS 12 SS DUST COVER ASSEMBLY 9102 13 E/F WASH DUST COVER 9091 1 10 3 6 12 TEST THIS UNIT EACH WEEK DUST COVER ASSY (OPEN POSITION) 13 8 11 4 5 SP65SS EYE/FACE WASH ASSEMBLY FOOT TREADLE 9 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (775) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM ECN NO. REVISED PER BY MODEL(S) PART NUMBER - ECN: 5241 VWC DRAWN DATE CHKD 8330 REVISION CJL 05/91 VWC APPROVED DATE SS SHOWER EYE/FACE WASH 25 FV 11/23/17 SCALE: 1/6 DRAWING TYPE: PARTS BREAKDOWN SIZE: A SHEET 1 OF 1 WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER. C 2017 Haws Corporation - All Rights Reserved R HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080174 PAGE 4 OF 5

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. NOTES: 1. WHEN INSTALLING THIS UNIT, LOCAL, STATE, OR FEDERAL CODES SHOULD BE ADHERED TO FOR INSTALLATION DIMENSIONS (LOCATIONS), WASTE AND SUPPLY REQUIREMENTS OTHER THAN SHOWN. 2. TO COMPLY WITH ANSI Z358.1-2014 FOR EMERGENCY EYEWASH OR EYE/FACE WASH: - EYEWASH OR EYE/FACE WASH SHALL BE POSITIONED SUCH THAT FLUSHING FLUID PATTERN IS NOT LESS THAN 33" (838mm) AND NO GREATER THAN 53" (1346mm) FROM SURFACE ON WHICH USER STANDS; AND 6.0" (153mm) MINIMUM FROM WALL OR NEAREST OBSTRUCTION. - SHOWER SHALL BE POSITIONED SUCH THAT SHOWER HEAD IS NOT LESS THAN 82" (2083mm) OR GREATER THAN 96" (2438mm) from SURFACE ON WHICH USER STANDS. - SHOWER SPRAY PATTERN SHALL HAVE A MINIMUM DIAMETER OF 20" (508mm) AT 60" (1524mm) ON WHICH USER STANDS. CENTER OF SPRAY PATTERN SHALL BE LOCATED AT LEAST 16" (406mm) FROM NEAREST OBSTRUCTION. 11" 279mm 3 29 7/16" 748mm SUPPLY 1-1/4" IPS 27 1/2" 699mm 5 OF 5 PAGE 3 IF NECESSARY USE LOCTITE 567 SEALANT ON MALE THREADS, JUST ABOVE THE FIRST THREAD. 4. DIMENSIONS MAY VARY BY ±1/2" (13 mm). 30 Ø9" Ø229mm 3X Ø3/8" Ø10mm 84 1/4" 2140mm 9102 DUST COVER (OPEN POSITION) 10" 254mm Ø8" Ø203mm B.C. MOUNTING DETAIL 33"-53" 838mm-1346mm FLOW PATTERN 44 1/16" 1119mm L-STRAINER SP220SS FLOOR LINE WASTE 1-1/4" IPS 6 1/2" 165mm 64 1/8" 1654mm C 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (775) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM ECN NO. REVISED PER BY: MODEL(S) PART NUMBER. ECN: 5241 VWC DRAWN: DATE: CHK'D.: 8330 REVISION C. HAYES 05/91 VWC APPROVED: DATE: SS SHOWER EYE/FACE WASH 25 FV 11/23/17 SCALE: 1/16 DRAWING TYPE: INSTALLATION SIZE: A SHEET 1 OF 1 R 2017 Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080174.D