PULSACOIL A CLASS USER GUIDE. TEL:

Similar documents
PULSACOIL 2000 USER GUIDE. TEL:

PULSACOIL 2000 ELECTRIC THERMAL STORE USER INSTRUCTIONS

BOILERMATE 2000 USER-GUIDE SWITCH. TEL: Gas Council Approved Reference Numbers

systemate 2000 fully integrated thermal store

BOILERMATE A CLASS SP

BOILERMATE A CLASS OV

Risk Assessment and Control Measures for Household Hot Water Systems

ADVANCE ECB ELECTRIC COMBINATION BOILER

User's Instructions. Alpha CB50

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Performance on demand

TORRENT ECO ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

TORRENT STAINLESS ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Description of the property and water systems:

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Vote for your Installer of the year at HEATSLAVE

Home owner user pack for the Nibe 200P

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Combi Konverter Solar System

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

The world s most advanced direct electric water cylinder

EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

UNIT 5 COLD WATER SUPPLY

Instructions for Use. To b e l e f t w i t h t h e u s e r. Clearly Solar System. including. Fluropro. Solar Differential Controller

Energy Ambassadors Guide

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

THERMAL STORE MAINS PRESSURE SYSTEM

Harlequin HeatStream Case Study

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Pressure Boosting Solutions

Samsung EHS Heat Pump Test

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Where gas is not an option,

Dove Eco thermostatic bar mixer shower

VENTED CYLINDER RANGE

ADVANCE ELECTRIC THERMAL STORE

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

HEATING SYSTEMS. A guide to your central heating system and helpful energy saving advice.

Total Hot Water Solutions

Hot Water Supply. Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong

25 per cent of energy used in the home is used to heat water.

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Bath Shower Mixer

THERMflow Thermal Store Cylinders

SEALED THERMAL STORE

GB24 & GB30. User Manual

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Combined electric boiler and domestic hot water store

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

CentaurPlus C21 Series 2 User Operating Instructions

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

THERMAL STORE MAINS PRESSURE SYSTEM

Energy and you. A guide to energy efficiency in your home. Energy and You A5.indd 1 26/10/ :15

Baxi Maxflow Combi WM

CentaurPlus C27 Series 2 User Operating Instructions

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

Domestic Green Deal Advice Training

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

THERMOSTATIC CONTROL TECHNOLOGY HORNE 40 AND 50 THERMOSTATIC MIXING SYSTEMS

Greenstar 12i/24i System

Baxi Maxflow Combi FS

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

THERMOSTATIC SHOWER VALVE

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

CPC-150-ANA. 150 litres, 535mm x 1300mm high. Pandora Heat Bank. 100kW Plate Heat Exchanger with 22mm Thermostatic Mixing Valve.

Pasto Sous vide water bath

Installation and Commissioning Manual

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

Unvented Hot Water Criteria

C106 Coded Access Keypad

Combi Eco Elite Range. User s Guide and Important Warranty Information

1 Day to Day Repairs

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

PS12 12 day Autotimer water softener

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

ST9400A User Guide. Features

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

Understand and apply domestic hot water system installation, commissioning, service and maintenance techniques

AIRE Thermostatic bar mixer Installation and operating instructions

Performance on demand. Eliminate poor mains water pressure and flow problems. with mainsboost

using electric storage heaters

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

Morco House Riverview Road Beverley HU17 0LD

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

USERS MANUAL FOR GAS BOILERS

Dene Bath Shower Mixer

FREQUENTLY ASKED QUESTIONS

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Torrent GreenHeat. Design, Installation & Servicing Instructions. Open vented thermal store providing heating and mains pressure hot water

Thermostatic Mixer Shower. Collection

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

irad Wireless Controller

CUBEflow Thermal Store Tank

Cylinder Manual. Open Vented Cylinders Stainless Steel Water Heaters. Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Transcription:

PULSACOIL A CLASS USER GUIDE Model Numbers PulsaCoil 145 PulsaCoil 185 PulsaCoil 215 PulsaCoil 235 A mains pressure hot water supply system incorporating an off peak electric thermal store TEL: 0800 14 55 55 7 www.pulsacoil-a-class.co.uk

CONTENTS Important - Please Note This appliance has been manufactured by Gledhill (Water Storage) Limited. Gledhill are an established manufacturer of water heating appliances. It is our policy to deal with the building trade rather than directly with consumers because our products should only be installed by suitably competent trades people and we recommend that consumers do not attempt to purchase and install our products. We offer a minimum one year warranty (guarantee) in respect of all appliances that we manufacture, but please note that our guarantee is given to the builder or installer that purchased the appliance from us and runs from the date of manufacture. In the unlikely event that there is a problem with our appliance it is important that you refer the problem as soon as possible to the person or company that supplied the appliance to you (your Supplier ). This will usually be the person or company that sold (or leased) the property to you or the person or company that installed the appliance for you. If you contact your Supplier in the first instance this will enable them to determine the cause of any problem that you may be experiencing. We have found that in many cases the cause of the problem is not a fault in the appliance itself but can be the result of some other factor. We would not, for example, be responsible for faulty installation of the appliance, and by contacting us directly this may simply cause you unnecessary delay and expense. Your Supplier can determine the cause of the problem and where the problem is caused by a fault with the appliance itself then your Supplier can advise us accordingly. Nothing in our guarantee or in these User Instructions will affect your statutory rights. Issue 5: October 2008 Page 2

Welcome To Your Thermal Storage System Pulsacoil A-Class - The Power Behind Your Domestic Hot Water The hot water in your home is provided by a high specification thermal storage system which will give you many benefits. Simple to operate and exceptionally efficient in operation, your PulsaCoil A- Class Thermal Store is probably different to any water heating system you have ever experienced before. This booklet will explain why and how you can get the most from it. Operating Characteristics - with a PulsaCoil A-Class, the domestic hot water you use at the tap is not stored but is produced instantaneously. This has the advantage of reducing the risk of contamination from things like Legionella as well as reducing the risks of scalding by allowing the temperature of the hot water at the tap to be controlled at about 52 C. However, this also means that when you open the tap, the temperature takes a little time to stabilise. - the reason is simple; tepid water in the house pipework arrives at the tap first. Then the system senses that a tap has been opened so heat exchange is started and the domestic hot water will go fully hot to sterilise the pipework. Following that the controller will kick in and the supply will settle at approximately 52 C. Page 3

- 52 C has been chosen to keep the risk of scalding to a minimum whilst still complying with the requirment to deliver water to the tap above 50 C for health /safety reasons; see HS (G) 70 HTM 2040. This system delivers fresh water from the mains supply to the hot taps and is designed to fulfil four basic needs. 1. Provide mains pressure hot water with an appliance that does not need a costly annual service. 2. Deliver hot water at good pressures whenever you need it. 3. Operate as efficiently as possible to cost-effectively meet your household needs. 4. Provide hot water to every tap of high quality. This is possibly because it has not been allowed to deteriorate in storage cisterns. Page 4

Depending on the wiring system within your property your installer/developer may have provided an off peak timer in the airing cupboard of your property. If a device is fitted it must be set to the correct time and set to synchronise with the off peak meter for correct economical operation. This should have been set when the system was commissioned but any power cuts could have altered the correct time. THIS APPLIANCE SHOULD BE LEFT PERMANENTLY CONNECTED TO THE OFF-PEAK ELECTRICAL SUPPLY AND NOT SWITCHED ON AND OFF WHEN HOT WATER IS NEEDED. PULSACOIL A-CLASS MODELS ALSO HAVE AN ON- PEAK BOOST WHICH CAN BE SWITCHED ON AS REQUIRED TO PROVIDE A BOOST TO THE TOP PART OF THE STORE ON DAYS WHEN A LARGE AMOUNT OF HOT WATER IS REQUIRED. Page 5

1. Deliver Hot Water At Good Pressures Whenever You Need It 2. Operate As Efficiently As Possible To Cost-effectively Meet Your Household Needs Your Thermal Storage System is designed to provide all the hot water you are likely to need under normal circumstances, and deliver that hot water at a pressure comparable with your cold water mains. This means that you can enjoy powerful showers without the need for a separate pump, or fill a bath with hot water in minutes. Your Thermal Storage System will ensure that the energy it needs is minimised, avoiding costly use of fuel by taking advantage of off-peak tariffs whenever they are available. Hot water is normally available any time you need it when the system is switched on, summer or winter. 3. Delivering High Quality Water To Every Tap 4. Scale With traditional systems which have a cold supply cistern in the roof space, there is always the risk that the tank could become contaminated by dust, birds or insects. The PulsaCoil is connected directly to the cold mains and therefore even the hot supply is pure high quality water every time. The water in the store never changes and therefore THE IMMERSION HEATER ELEMENTS WILL NEVER SCALE UP DURING THE LIFE OF THE PRODUCT. As far as the water you use is concerned scale can be a problem in any of your domestic products if the water is very hard in your area. Page 6

The PulsaCoil A-Class appliance has been designed to inhibit the formation of scale, but if it does become a problem you will notice a deterioration in the flow rate at your hot taps. In this situation your service engineer can quickly and easily change the plate heat exchanger for a service exchange unit. What Is A Thermal Store? The Gledhill Thermal Store is the heart and brain of your hot water system. It stores hot water at a constant temperature and incorporates a highly efficient plate heat exchanger which heats the hot water for all your domestic needs. The Thermal Store is superbly insulated and so the hot water stored has a very low heat loss. Off-peak supplies will automatically be used to heat the thermal store. The appliance also provides you with the option to switch on the on-peak electricity supply when necessary to provide a boost to the top part of the thermal store to achieve the most efficient way of satisfying your demands on the system. How Does The System Deliver Hot Water At High Pressure? The water delivered to the taps and showers in your home is supplied at high pressure because it uses the mains pressure of your cold water supply. The PulsaCoil is connected to the mains system and the water passes through a highly efficient heat exchanger to raise its temperature before it travels to your taps and showers. Because it is Page 7

so efficient, both high flow rates and high pressures are available to give the best performance for both baths and showers. Why Are There No Water Cisterns In The Loft? Water tanks in the loft are required principally for the traditional domestic hot water system to give a better head of water - which is basically determined by the height of the cistern above the tap being used. In most cases, the higher the cistern, the greater the pressure. Because the Gledhill system uses the pressure from your cold water mains, these cisterns are not required. This removes any worries about freezing or contamination of the cold water system from insects, dust, birds etc and leaves more space for storage should you decide to use it. Page 8

Plastic Top Up Cistern The plastic feed tank should have been filled to the water line by the installer at the time of commissioning. The water level in the plastic feed tank should be checked on a regular basis, generally 3-4 times a year, and topped up when necessary to approximately half way. Once the level has been topped up or after it has been checked, ensure the lid has been securely replaced. An optional sight glass can be fitted to the side of the feed tank, to overcome the need to remove the lid to check the water level. Annual Service / Safety Check Unlike other hot water appliances which provide mains pressure hot water, appliances, such as unvented storage cylinders, no costly annual service / safety check is required. Page 9

However, as the manufacturer, we can offer an annual breakdown agreement once the warranty has expired:- see separate leaflet. What If The System Develops A Fault? OFF ON FLASHING PUSH BUTTON Normal On-Peak boost active Fault attention required To activate On-Peak boost If your PulsaCoil should develop a fault during the warranty period, try resetting the appliance in accordance with the instructions on the user control panel on the front of the appliance. If this is unsuccessful, switch the unit off and contact your house manager/installer. Do not attempt to remove or adjust any component part yourself. ON/OFF SWITCH REMINDER Control circuit power supply If the developers warranty has expired contact the manufacturer if you have an active Breakdown Agreement. The user control panel on the front of the PulsaCoil has a manual boost switch/facility. This should be switched on to provide a boost to the top part of the Thermal Store on days when a large amount of hot water is required. When pressed the indicator light will illuminate and the on-peak boost will remain active until the next time the offpeak supply becomes available (unless switched off again manually). If you are considering changing your electricity supplier it is important that you ensure they are able to provide at least the same tariff. If not the operation and cost of running the appliance will be affected. Page 10

Sales, Service & Repair PulsaCoil A Class C/O Hot Water Cylinders Limited 302 Foxhunter Drive Milton Keynes MK14 6GD TEL: 0800 14 55 55 7 www.pulsacoil-a-class.co.uk