THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Similar documents
OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

Biological Safety Cabinet Failure Response Procedure

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Centrifuge STANDARD OPERATING PROCEDURE

CYGNUS CF VI BLOOD CENTRIFUGE OPERATORS MANUAL

LSU Inter-Institutional Biological and Recombinant DNA Safety Committee (IBRDSC)

Authentic Instrument & Automation (P) Ltd. Products Presentation. By: Mr. O.P. Singh. X2 Series

Safe Use of a Class II Biological Safety Cabinet

General Workplace Safety Checklist

Laboratory Safety Audit

OH&S WORKPLACE ASSESSMENT INSPECTION CHECKLIST

Laboratory Safety Audit

A. General Safety LAB/ROOM: INSPECTED BY: DATE:

Centrifuge/Vortex for PCR plates CVP-2

Class II Biosafety Cabinets

Centrifuge Biosafety. Brian Petuch, CBSP, RBP. The Usual Photo and Story

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

Florida International University. Biosafety Cabinet Program

Appendix C IBC Safe Use of Biosafety Cabinets SOP

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LABORATORY INSPECTION CHECKLIST

THE UNIVERSITY OF NEWCASTLE- SCHOOL OF BIOMEDICAL SCIENCES

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT

Manual Page 1 of 8. Manual. Laboratory autoclave

Reliability in Laboratory Centrifuges Since Operator s Manual. Models 614B, 614L, 614U/UL and 614V/VL Laboratory Centrifuge. Rev. 5.

Centrifuge STANDARD OPERATING PROCEDURE

Physical Hazards -Recognition, Evaluation and Control

Digital Heat Block User Manual

THE COMPACT CENTRIFUGE: OPERATOR 1

EMERGENCY RESPONSE PLAN FOR

Instruction Manual. Centrifuge SMC 6. with horizontal rotor 6 x SARSTEDT No.:

Instruction Manual Centrifuge LC 6 with horizontal rotor 6 x

Dangerous Waste Generator Training. How do I properly manage wastes generated in my work area?

INSTRUCTION MANUAL. Models: V V V UK V EU. CLS-EQ-104 October 2013, Document 01, Revision 02

HEALTHCARE SAFETY INSPECTION

OPERATING MANUAL NanoFlow

Emergency Response Guide for Laboratories

STANDARD OPERATING PROCEDURE FOR VARIOUS INSTRUMENTS

LAB SAFETY FOR CUSTODIANS

AUBURN UNIVERSITY X-RAY SAFETY STANDARD OPERATING PROCEDURES

Go to the Lab! Lab Safety Begins Before You

WORKPLACE INSPECTION CHECKLIST FOR LABORATORY ENVIRONMENTS

Instruction Manual. Juice Extractor. Model: ESI Dezembro/2008

Department of Civil and Environmental Engineering University of Waterloo

Instructions for use. Tango & Tango XL , Shower-toilet chair

elaundercare; On Premise Laundry Procedures

getting the best from your new cleaner...

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

VP, Facilities and Construction Management

CR-1730R User s Manual

Instruction Manual MICRO CENTAUR PLUS CENTRIFUGE READ BEFORE USE!

SAFETY AND OPERATING MANUAL

This document provides general instructions on the use of chemical fume hoods to protect lab personnel against exposure to hazardous materials.

Applicable To Employees of the Gundersen St. Joseph s Hospital laboratories and Gundersen Tri-County Hospital laboratories.

An MRI Centre An MRI centre shall be defined as a facility with the following minimum requirements as listed in sections A to G below:

Chapter 10: Laboratory Equipment

EMERGENCY RESPONSE GUIDE IMMEDIATE EMERGENCY PROCEDURES

Instruction Manual JEN0002 / Version 1.0. Peltier Accessory

Laboratory Centrifuge

Aluminum Heating Mantles

Biological Safety Cabinets or Fume Hoods Which one to use?

PART III. Laboratory equipment

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

Ion OneTouch Template Kit Publication Part Number Revision E Date 31 October 2011

Automatic Cell Washing System Operation Manual

Affix Stamp Dear Customer,

Low Speed Centrifuge. Model XC-2415 Model XC-2450 Operating Manual

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

Central Glasshouse Services Induction Training. Glasshouse Client Induction 2015

University of Minnesota Nano Fabrication Center

METALÚRGICA SIEMSEN LTDA. INSTRUCTION MANUAL CENTRIFUGAL JUICER MODELS CS / CSE

Instruction Manual. Table Top Steamer Cart

Super Elite Watch cleaning machine

LABORATORY CHEMICAL HYGIENE AND SAFETY PLAN

Tornado Operations & Maintenance Manual

DAE Systems. Fan Selection Guide. Section 1: Terminology

SCIF SOP for BSL 2 samples on Aria3

Installation, Operation, Maintenance, & Troubleshooting Model: CLS36-440V Electric Cruise Line Salamander Serial:

TK 806 Z. Bedienungs- und Wartungshandbuch. Livret d instructions et d entretien. Manuale uso e manutenzione. User instructions and maintenance

Dry Bath Heating Systems

LH 3 Resina Capper Document No. LH3

PROMOCIJA LABORATORIJSKE OPREME.

Gerber Centrifuge Micro II. Instruction Manual (e)

Packing Instructions Heraeus Primo R

MCDB4100: LABORATORY SAFETY GUIDELINES

SAFE WORK PROCEDURE. List the Hazards and risk controls as per risk assessment. assessment reference:

Student Lab Procedures. Lab Safety Orientation

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

DRAFT. Module 4. Decontamination & Environmental Cleaning

TERRACE AND PATIO HEATER

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

Register your instrument! Eppendorf ThermoMixer C. Operating manual

Reacti-Therm I and III Heating/Stirring Modules

s ter k Hea y Bloc Dr

Environmental Health and Safety Biological Safety Program Guidance Document

Dry Block Heaters. Dry Block Heaters. 2 Block Dry Block Heaters with Lid.

Chapter 18 Welding Table of Contents

DEPARTMENTAL SAFETY ISSUES - SAFETY TECHNOLOGIST / INFECTION CONTROL PRACTITIONER

Transcription:

Page: 1 of 5 1. Risk Assessment: Operation of Centrifuge TASK PERFORMED HAZARDS 1. Severe machine imbalance leading to machine destruction and possible injury to those in the vicinity 2. Exposure to biohazards/hazardous substances as a result of broken/leaking vessels RISK ASSESSMENT 1. The risk of machine imbalance is present while ever the equipment is in use. These risks are increased if the user is not trained or if the centrifuge is not regularly maintained. 2. Risk of exposure to biohazards due to broken/leaking vessels is present while ever the machine is in use. RISK CONTROL 1. Only trained staff are to use this equipment. Tubes must be balanced by weight before inserting into the centrifuge. Only tubes especially made for centrifugation are to be used. Establish a safety zone of 30cm around the centrifuge and ensure that no personnel or hazardous substances enter the zone during centrifugation. Check rotors regularly for signs of irregular wear/damage. 2. Use only specifically designed centrifuge tubes and ensure they are properly sealed before centrifugation. In the event of a spill, decontaminate machine immediately - follow spill procedures (GDP 011) and machine disinfecting instructions. Wear appropriate personal protective equipment. Use sealed rotors when centrifuging infectious or hazardous agents. 2. Calibration: N/A 3. Monitoring: NAME (signed) DATE WRITTEN BY CHECKED BY Distributed To: GEP Master File / GEP Lab File

Page: 2 of 5 3.1 Frequency: Whenever in use. 3.2 Method Listen carefully to the centrifuge to ensure its operating sounds are characteristic to this particular machine. If there is any unfamiliar sounds coming from this equipment when it is in operation it could possibly mean that the rotor is unbalanced and must be turned off immediately. This is to avoid major damage to the centrifuge and possible safety hazards. 4. General Operation: 4.1 Ensure that the centrifuge is connected to the power point and that it is turned on. The unit also has a mains switch, either on the front or rear of the machine (depending on model). Locate this switch and turn it on. 4.2 Open the lid by pressing down on the lever on the right side of the centrifuge (indicated as number 7 on the diagram in section 1 of the Operating Instructions, attached to this GEP). Remove the clear plastic rotor cover. 4.3 Refer to section 4.6 of the Operating Instructions (Attachment 10.1), for information on load balancing. Insert tubes to be centrifuged, replace the rotor cover and close the lid. 4.4 Set the speed for centrifugation by turning the speed setting knob (no. 1 on diagram). The maximum is 14 000 RPM. 4.5 Set the time length of the run, by turning the thumb wheel (no. 6 on diagram) to the time required. The maximum timed run for this centrifuge is 15 min. For a longer spin, set the thumb wheel to 0 (as 0 = ). The centrifuge will continue running until it is stopped by the operator. 5. Cleaning: 5.1 Frequency 5.1.1 Cleaning must be carried out when required and immediately in the case of a spill.

Page: 3 of 5 5.2 Method 5.2.1 The rotor chamber and accessories must only be cleaned with soap and water. NB Ensure that the centrifuge is disconnected form the power supply before commencing cleaning. 5.3 Records: Record all cleaning details on the Maintenance Record Sheet (Illustration 9.1) 6. Maintenance: 6.1 Method: Refer to section 5 - 'Cleaning and Maintenance' of the Operating Instructions (Attachment 10.1). 6.2 Records: Record all Maintenance details on the Maintenance Record Sheet. 7. Instruction Manual: 7.1 Available - Copy Attached. 8. Repairs: 8.1 Check ERN for Service Company and warranty details 8.2 Contact the University Workshop for advice and repairs 9. Illustrations: 9.1 Maintenance Record Sheet 10. Attachments: 10.1 Operating Instructions (). 11. Change History: 11.1 Issue Number: 1st Issue 11.2 Issue Number: Date Issued: Date Issued: Reason for Change:

Page: 4 of 5 ILLUSTRATION 9.1 MAINTENANCE RECORD SHEET - Jouan A12 ERN# 126 SERIAL# 29309376 DATE MAINTENANCE SIGNED

Page: 5 of 5 ILLUSTRATION 9.1 MAINTENANCE RECORD SHEET - Jouan A14 ERN# 97 SERIAL# 1150112 DATE MAINTENANCE SIGNED