SANS 506 (2011) (2017-08-04) Timber preservative - Alkaline-copper-quaternary type Covers two types of alkaline-copper-quaternary (ACQ) type timber preservatives and gives minimum and maximum values of active ingredients..01 A4 12p EN PDF 12p EN Replaced by: SANS 506 (2017) 71.100.50 SANS 871 (SABS 871) (2009) (2017-08-04) Boron timber preservatives Covers requirements for the following three types of boron timber preservatives, type I: a sodium borate of a composition corresponding approximately to that of disodium octaborate tetrahydrate, type II: a mixture of borax and boric acid and type III: a polyborate derivation that contains emulsified wax. A4 11p EN PDF 11p EN Replaced by: SANS 871 (SABS 871) (2017) 71.100.50 SANS 1151 (SABS 1151) (2010) (2017-09-15) Portable rechargeable fire extinguishers - Halogenated hydrocarbon type extinguishers Specifies the characteristics of stored pressure, portable rechargeable fire extinguishers of the halogenated hydrocarbon type, of capacity not exceeding 12 Kg and suitable for use on fires of classes A, B and C..02 A4 25p EN PDF 25p EN Am 1(National), 2005-04-29 Am 2(National), 2010-06-04 Replaced by: SANS 1151 (SABS 1151) (2017) 13.220.10 SANS 1194 (SABS 1194) (2006) (2017-08-04) Nylon tubing for air-brake applications Covers requirements for two types of nylon tubing as used in the motor industry in assemblies that convey air to operate pneumatic braking systems. A4 14p EN PDF 14p EN Replaced by: SANS 1194 (SABS 1194) (2017) 43.040.40 SANS 1251 (SABS 1251) (2005) (2017-08-04) Engine cooling system protectors Covers glycol-type compounds which, when added at adequate concentrations to water in engine cooling systems, provide protection against corrosion, lower the freezing point, and raise the boiling point of the resultant coolant. Replaced by: SANS 1251 (SABS 1251) (2017) 43.060.; 71.100.45 SANS 1339 (SABS 1339) (2015) (2017-08-04) Electric cables - Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv Specifies the construction, materials, dimensions and test requirements for single-core and three-core cross-linked polyethylene (XLPE) insulated cables with copper or aluminium conductors, for use at operating voltages in the range 3,8/6,6 kv to 19/33 kv. Ed 5 A4 52p EN PDF 52p EN Replaced by: SANS 1339 (SABS 1339) (2017) 29.060.20; 29.240.20 SANS 1509 (SABS 1509) (2008) (2017-08-04) Flush valves for WC flushing cisterns Covers requirements for the construction and performance of four types and three sizes of flush valves for WC flushing cisterns..01 A4 14p EN PDF 14p EN 91.140.70 Am 1(National), 2008-03-28 Replaced by: SANS 1509 (SABS 1509) (2017)
SANS 1550-1 (SABS 1550-1) (2005) (2017-09-15) Motor vehicle tyres and rims - Dimensions and loads Part 1: General Specifies the general requirements for motor vehicle pneumatic tyres, giving the basic definitions, details of the parameters used for tyre marking requirements and a test method for the measurement of tyre dimensions.01 A4 15p EN Am 1(National), 2005-12-23 PDF 15p EN Replaced by: SANS 1550-1 (SABS 1550-1) (2017) 43.040.50; 83.160.10 SANS 1550-3 (SABS 1550-3) (2006) (2017-09-01) Motor vehicle tyres and rims - Dimensions and loads Part 3: Commercial vehicle tyres Covers commercial vehicle tyres..01 43.080.01; 83.160.10 Am 1(National), 2006-03-03 Replaced by: SANS 1550-3 (SABS 1550-3) (2017) SANS 1645 (SABS 1645) (2009) (2017-09-01) Portable insulated domestic food containers Specifies requirements for portable insulated bags, boxes and similar storage units intended for the domestic storage of food and beverages..01 A4 16p EN PDF 16p EN 55.160; 97.040.99 Am 1(National), 2009-02-27 Replaced by: SANS 1645 (SABS 1645) (2017) SANS 1689 (2016) (2017-09-15) Corrugated stainless steel piping systems for hot and cold water supplies Specifies the minimum requirements for the design, manufacture, testing and installation of stainless annular corrugated metal tube and fittings. A4 21p EN PDF 21p EN Replaced by: SANS 1689 (2017) 91.140.60 SANS 1777 (SABS 1777) (2011) (2017-09-15) Photoelectric control units for lighting (PECUs) Specifies the requirements for photoelectric control units (PECUs) (also known as daylight switches), for lighting installations designed to switch a reactive load not exceeding 1 800 VA at 2 V and 50 Hz..03 A4 16p EN PDF 16p EN Am 1(National), 2000-06-09 Am 2(National), 2004-04-23 Am 3(National), 2011-01-28 Replaced by: SANS 1777 (SABS 1777) (2017) 31.260; 93.080.40 SANS 1808-2 (SABS 1808-2) (2013) (2017-08-04) Water supply and distribution system components Part 2: Metallic compression type pipe couplings Amended to update normative references..04 A4 8p EN PDF 8p EN 23.040.60 Am 1(National), 1999-10-29 Am 2(National), 2005-05-20 Am 3(National), 2010-05-07 Am 4(National), 2013-12-13 Replaced by: SANS 1808-2 (SABS 1808-2) (2017) SANS 1828 (SABS 1828) (2016) (2017-09-01) Cleaning chemicals for use in the food industry Specifies general requirements for cleaning chemical intended for use in the food industry. Sets minimum requirements for the safety of such cleaning chemicals. A4 15p EN PDF 15p EN Replaced by: SANS 1828 (SABS 1828) (2017) 71.100.40
SANS 1934 (2004) (2017-08-25) Live working - Portable equipment for earthing or earthing and short-circuiting - National modifications to international requirements Specifies the national limitations on, and additions to, the international standard IEC 612 (published in South Africa as an identical adoption under the designation SANS 612) for portable earthing equipment for busbars and overhead lines. Applies to equipment for temporary earthing of electrically isolated transmission and distribution systems, for the protection of workers and operating personnel. Replaced by: SANS 1934 (2017) 13.260; 29.260.99 SANS 1973-8 (2008) (2017-09-15) Low-voltage switchgear and controlgear ASSEMBLIES Part 8: Safety of minimally tested ASSEMBLIES (MTA) with a rated shortcircuit current above 10 ka and a rated busbar current of up to and including 1 600 A a.c. and d.c. Applicable to low-voltage switchgear and controlgear assemblies that are subjected to minimum tests for verifying the safety of the ASSEMBLY; that have a rated prospective short-circuit current above 10 ka and a rated busbar current of up to and including 1 600 A a.c. and d.c.; that are stationary or movable; that have a rated operational voltage not exceeding 1 000 V a.c.; that are intended for use in connection with the generation, transmission, distribution and conversion of electric energy; that incorporate control equipment, or power equipment (or both); and are designed for use under normal conditions but excluding the use in explosive atmospheres where special requirements apply. A4 40p EN PDF 40p EN Replaced by: SANS 1973-8 (2017) 29.1.20 SANS 10098-2 (SABS 098-2) (2005) (2017-08-04) Public lighting Part 2: The lighting of certain specific areas of streets and highways Lays down recommendations for the lighting of road areas of special importance and where normal conventional street lighting techniques in accordance with SANS 10098-1 might not apply. A4 50p EN PDF 50p EN Replaced by: SANS 10098-2 (SABS 098-2) (2017) 93.080. SANS 10119 (SABS 0119) (2011) (2017-08-11) Reduction of explosion hazards presented by electrical equipment - Segregation, ventilation and pressurization Covers the use of segregation, ventilation and pressurization in order to reduce the explosion risk at locations where there are gases or vapours..02 Am 1(National), 2001-11-09 Am 2(National), 2011-03-04 Replaced by: SANS 10119 (SABS 0119) (2017) 29.260.20 Stage: 92.60 (2017-08-11) SANS 13720 (2009) (2017-09-15) Meat and meat products - Enumeration of Pseudomonas spp. Describes a method for the enumeration of Pseudomonas spp. present in meat and meat products, including poultry. 07.100.; 67.120.10 ISO 13720:1995, idt SANS 15693-3 (2004) (2017-08-25) Identification cards - Contactless integrated circuit(s) cards - Vicinity cards Part 3: Anticollision and transmission protocol Describes protocol and commands, methods to detect and communicate with one card among several cards (anticollision), and optional means to ease and speed up the selection of one among several cards based on application criteria. A4 51p EN ISO/IEC 15693-3:2001, idt PDF 51p EN Replaced by: SANS 15693-3 (2017) 35.240.15
SANS 16649-3 (2008) (2017-09-15) Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli Part 3: Most probable number technique using 5-bromo-4-chloro-3-indolyl-beta-D-glucuronide Specifies a horizontal method for the enumeration of ß-glucuronidase-positive Escherichia coli, by means of the liquid-medium culture technique and calculation of the most probable number (MPN) after incubation at 37 C, then at 44 C. It is applicable to products intended for human consumption and the feeding of animals, and to environmental samples in the area of food production and food handling. A4 13p EN ISO/TS 16649-3:2005, idt PDF 13p EN Replaced by: SANS 16649-3 (2017) 07.100. SANS 17604 (2009) (2017-09-15) Microbiology of food and animal feeding stuffs - Carcass sampling for microbiological analysis Specifies sampling methods for the detection and enumeration of microorganisms on the carcass surface of freshly slaughtered meat animals. A4 19p EN ISO 17604:2003, idt PDF 19p EN Replaced by: SANS 17604 (2017) 07.100. SANS 51176-11 (2010) (2017-08-25) Playground equipment and surfacing Part 11: Additional specific safety requirements and test methods for spatial network Specifies additional safety requirements for spatial network intended for permanent installation for use by children. Not applicable to artificial climbing structures, which are used for training for sports activities, e.g. alpinism. A4 9p EN EN 1176-11:2008, idt PDF 9p EN Replaced by: SANS 51176-11 (2017) 97.200.40 SANS 60034-12 (SABS IEC 60034-12) (2008) (2017-09-15) Rotating electrical machines Part 12: Starting performance of single-speed three-phase cage induction motors Specifies the parameters for four designs of starting performance of single-speed three-phase 50 Hz or 60 Hz cage induction motors that have a rated voltage up to 1 000 V, are intended for direct-on-line or star-delta starting, are rated on the basis of duty type S1 and are constructed to any degree of protection..01 A4 13p EN IEC 60034-12:2007, idt Am 1(National), 2008-03-07 PDF 13p EN Replaced by: SANS 60034-12 (SABS IEC 60034-12) (2017) 29.160. SANS 60086-5 (SABS IEC 60086-5) (2012) (2017-09-15) Primary batteries Part 5: Safety of batteries with aqueous electrolyte Specifies tests and requirements for primary batteries with aqueous electrolyte to ensure their safe operation under intended use and reasonably foreseeable misuse. A4 37p EN IEC 60086-5:2011, idt PDF 37p EN Replaced by: SANS 60086-5 (SABS IEC 60086-5) (2017) 29.220.10 SANS 60335-2-72 (SABS IEC 60335-2-72) (2015) (2017-09-01) Household and similar electrical appliances - Safety Part 2-72: Particular requirements for floor treatment machines with or without traction drive, for commercial use Deals with the safety of powered ride-on and powered walk-behind machines intended for commercial indoor or outdoor use for the following applications: sweeping, scrubbing, wet or dry pick-up, polishing, application of wax, sealing products and powder based detergents, and shampooing of floors with an artificial surface. Applies to machines for commercial use. A4 60p EN IEC 60335-2-72:2012, idt PDF 60p EN Replaced by: SANS 60335-2-72 (SABS IEC 60335-2-72) (2017) 97.080
SANS 60335-2-79 (SABS IEC 60335-2-79) (2014) (2017-09-15) Household and similar electrical appliances - Safety Part 2-79: Particular requirements for high pressure cleaners and steam cleaners Deals with the safety of high-pressure cleaners without traction drive, intended for household and commercial indoor or outdoor use, having a rated pressure not less than 2,5 MPa and not exceeding 35 MPa. Applies to steam cleaners and those parts of hot water high pressure cleaners incorporating a steam stage which have a capacity not exceeding 100 l, a rated pressure not exceeding 2,5 MPa and a product of a capacity and a rated pressure not exceeding 5 MPa/l. A4 63p EN IEC 60335-2-79:2012, idt PDF 63p EN Replaced by: SANS 60335-2-79 (SABS IEC 60335-2-79) (2017) 97.080 SANS 61058-1 (SABS IEC 61058-1) (2009) (2017-08-25) Switches for appliances Part 1: General requirements Applies to switches for appliances actuated by hand, by foot or by other human activity, to operate or control electrical appliances and other equipment for household and similar purposes with a rated voltage not exceeding 480 V and a rated current not exceeding 63 A..02 A4 158p EN IEC 61058-1:2008, idt PDF 158p EN 29.120.40 Am 1, 2002-10-09 Am 1(National), 2008-01-18 Cor 1, 2009-06-12 Am 2, 2009-06-12 Replaced by: SANS 61058-1 (SABS IEC 61058-1) (2017) SANS 61386-1 (SABS IEC 61386-1) (2008) (2017-08-25) Conduit systems for cable management Part 1: General requirements Specifies requirements and tests for conduit systems, including conduits and conduit fittings, for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems up to 1 000 V a.c. and/or 1 500 V d.c. Applies to metallic, non-metallic and composite conduit systems, including threaded and non-threaded entries which terminate the system. A4 39p EN IEC 61386-1:2008, idt PDF 39p EN Replaced by: SANS 61386-1 (SABS IEC 61386-1) (2017) 29.120.10 SANS 62282-6-0 (2010) (2017-09-15) Fuel cell technologies Part 6-0: Micro fuel cell power systems - Fuel cartridge interchangeability Covers interchangeability of micro fuel cell (MFC) fuel cartridges to provide the cartridge compatibility for a variety of MFC power units while maintaining the safety and performance of MFC power systems. For this purpose, the standard covers fuel cartridges and their connector designs. Fuel type, fuel concentration and fuel quality are also covered. This standard also provides for the means to avoid the missconnection of an improper fuel cartridge. Test methods for verifying the compliance with the interchangeability requirements for fuel and fuel cartridges are also provided in this standard. A4 99p EN IEC 62282-6-0:2009, idt PDF 99p EN Replaced by: SANS 62282-6-0 (2017) 27.070