ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

Similar documents
Submittal Summary Page

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48PGD/E/F/L/M/N PG20-28

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

48TM GAS HEATING/ELECTRIC COOLING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

DCG Commercial. Submittal Data Form

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

VertiCool Aurora Engineering Guide

50TM COMBINATION HEATING/COOLING UNITS

C13-Series Engineering Guide

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50TM TFF COMBINATION HEATING/COOLING UNITS

62DA,DB,DC,DD,DE,DF07-38

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES

Roof Top Packaged Unit (RTU-1) Specification

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Multi-Path RTU-TYPE 2

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

RGE 13 A T - 1 A

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SUBMITTAL DATA. Medbrooke ADD. Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV for. Prepared for

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

SUNLINE BP 180 SUNLINE MAGNUM - BP 240

Packaged Heat Pumps. Voyager 12½ to 20 Tons 60 Hz PKGP-PRC001-EN. September 2004

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

PAR5. Product Specifications

VariCool VAV Engineering Guide

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Corp L2 Revised

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

13 GEP A L P - 1 A


Product Data. Fig. 1 - Unit 50VR -A

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric Tons, 50 Hz RT-PRC073B-EN. May 2018

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Product Catalog. Packaged Rooftop Air Conditioners Foundation Cooling and Gas/Electric 3 to 5 Tons, 60Hz RT-PRC078C-EN.

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE CHAMPION PLUS SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 3 AND 4 NOMINAL TON GENERAL

High Heat COP. High/Low Stage

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

RHEEM PACKAGE GAS/ELECTRIC

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DF NOMINAL TONS 10.4 EER YTG-F-0109

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Packaged Cooling with Electric Heat Rooftop Units

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz RT-PRC079B-EN. June 2017

Packaged Cooling with Electric Heat Rooftop Units

Split System Cooling Units

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

R-410A LUXAIRE ACCLIMATE DYX MODELS 2-4 TON 60 Hertz

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL SPECIFICATIONS

Split System Heat Pumps

THE RIGHT SPEC. RIGHT NOW.

INSTALLATION INSTRUCTIONS

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Addendum Downsville Pike Hagerstown MD April 29, 2016

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Ruud Commercial Achiever Series Package Gas Electric Unit

Packaged Heat Pumps. Precedent - R-410A Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC013-EN. August 2009

Product Catalog. Packaged Rooftop Air Conditioners Foundation Cooling and Gas/Electric 15 to 25 Tons, 60 Hz RT-PRC060H-EN.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Submittal Data Performance Data Electrical Data

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Transcription:

ADDENDUM 1 CLIENT: PROJECT: TO: FROM: Guilford County Schools (GCS) Southeast High School Auditorium & Gymnasium HVAC Improvements All Prospective Bidders Derrick Giles, SAMR, PLLC. DATE: 6/6/2018 The attached information is intended to clarify questions regarding the construction documents. Please contact Derrick Giles at (336) 988-1769, gilesde@enpulse.com with any questions regarding this addendum, the drawings or specifications. Where any article, division or subparagraph of the original contract documents or other addenda is supplemented herein, the provisions of the original documents shall remain in effect. All the supplemental provisions shall be considered as added thereto. Where any such article, division or subparagraphs are amended, voided or superseded thereby, the provisions of such article, division or subparagraph not so specifically amended, voided or superseded shall remain in effect. The attention of the Contractor is called to the following clarifications, additions to and changes in the advertisement, plans and specifications dated or released: June 1, 2018 on the above job. It will be the responsibility of each Contractor to call such clarifications, additions and changes in plans and specifications to the attention of subcontractors concerned. The Engineer, his/ her Architect, or Consulting Engineers in no way assume any responsibility for notifying any subcontractor, material dealers or others not having received the original contract documents. 1. NOT USED 2. GENERAL See attached scope, bid / project schedule, and site photos. Additional contract documents will be issued via addenda according to the schedule. 1 of 2 P.O. Box 41195 Greensboro, NC 27404

3. ATTACHMENTS 3.1. Project scope and schedule 3.2. Site photos (8) 3.3. Equipment BOD NOTE: Please make sure you acknowledge this addendum on the bid form. END OF ADDENDUM 1 2 of 2 P.O. Box 41195 Greensboro, NC 27404

6/4/2018 SUMMARY OF WORK Southeast High School Auditorium & Gymnasium HVAC Improvements Demolish 4 existing 20 ton, split DX with HW coil units. (Base bid is the 2 auditorium units; alternate bid (add alternate) is the 2 gymnasium units) Provide 4 new 20 ton roof mounted package units with gas heating. Basis of Design is York J20ZRN30R2C5FCA4M1. Reference: Kevin Brese, 336.402.8958 Ductwork shall be furnished from the new RTU, through a vertical exterior wall opening, and tie-in to existing auditorium ductwork Contractor shall provide new conductors, disconnect and 125 A breakers, in existing conduit, to supply electrical power to the new RTUs. Install new gas supply piping Stand alone controls for each RTU See included 8 photos and RTU Basis of Design for reference SCHEDULE Advertisement - 6/4/18 Pre-bid Non-mandatory - Friday, 6/8/18 @ 1 PM (on-site) Last Day for Questions - 6/15/18 Last Day for Addenda - 6/18/18 Bid Opening - 6/20/18 @ 3 PM (Washington St) Construction start - Fall 2018 Contact: Derrick Giles, 336.988.1769, gilesde@enpulse.com

Project Name: GCS-Southeast Series 20 (15-25 Ton Package) N540 Single Package R-410A AC with Reheat Page: 1 Unit Model #: J20ZRN30R2C5FCA4M1 Quantity: 1 Tag #: RTU- Auditorium System: J20ZRN30R2C5FCA4M1 Cooling Performance Total gross capacity 258.1 MBH Sensible gross capacity 189.9 MBH Total net capacity 241.9 MBH Sensible net capacity 173.7 MBH Efficiency (at ARI) 11.00 EER Integrated eff. (at ARI) 13.00 IEER Ambient DB temp. 95.0 F Entering DB temp. 80.0 F Entering WB temp. 67.0 F Leaving DB temp. 58.0 F Leaving WB temp. 56.8 F Power input (w/o blower) 17.67 kw Sound power 92 db(a) Refrigerant Refrigerant type R-410A Sys1 24 lbs Sys2 24 lbs Reheat Performance Total capacity 118.9 MBH Ambient DB temp. 85 F Entering DB temp. 75 F Entering WB temp. 67 F Leaving DB temp. 75 F Leaving WB temp. 62.7 F Power input (w/o blower) 15.78 kw Gallons of water per hour 13.57 gal/hr Gas Heating Performance Entering DB temp. 60 F Heating output capacity (Max) 240 MBH Supply air 8000 CFM Heating input capacity (Max) 300 MBH Leaving DB temp. 87.8 F Air temp. rise 27.8 F SSE 80.0 % Stages 2 Supply Air Blower Performance Supply air 8000 CFM Ext. static pressure 0.6 IWG Blower speed 907 RPM Max BHP of Motor (including service factor) 11.50 HP Duct location Side Motor rating 10.00 HP Actual required BHP 5.66 HP Power input 4.75 kw Elevation 0 ft. Drive type BELT Electrical Data Power supply 230-3-60 Unit min circuit ampacity 101.5 Amps Unit max over-current protection 125 Amps Dimensions & Weight Hgt 53 in. Len 181 in. Wth 92 in. Weight with factory installed options 3055 lbs. Clearances Right 36 in. Front 36 in. Back 24 in. Top 72 in. Bottom 0 in. Left 24 in. Note: Please refer to the tech guide for listed maximum static pressures 20 Ton Johnson Controls Series 20 Units are Manufactured at an ISO 9001 Registered Facility and each Rooftop is Completely Computer-Run Tested Prior to Shipment. Unit Features Two Stage Cooling 300 MBH Input Aluminized Steel, Two Stage Gas Heat Full Perimeter Base Rails with Built in Rigging Capabilities Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117 Standards). Either Supply and/or Return can be Field Converted from Vertical to Horizontal Configuration without Cutting Panels Dual Refrigerant Circuits for Efficient Part Load Operation with Scroll Compressors Dry Bulb Low Leak Economizer with Hood (No Barometric Relief Damper or Hood) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511) 10 HP High Static Belt Drive Blower Unit Ships with 2" Throwaway Filters Solid Core Liquid Line Filter Driers Replacement Filters: 4 - (16" x 25" x 2" or 4") AND 4 - (16" x 20" x 2" or 4"). Unit accepts 2" or 4" wide filters. Non Powered Convenience Outlet (110 VAC) HACR Circuit Breaker/Disconnect Short Circuit Current: 5kA RMS Symmetrical Single Point Power Connection Through-the-Curb and Through-The-Base Utility Connections Dirty Filter Indicator Switch Phase Monitor Standard Condenser Coil Standard Evaporator Coil Crane Required to Unload Unit Stainless Steel Drain Pan Hinged Filter Door & Tool Free Non-Hinged Blower, Motor, Electrical Access Panels Coil Guard BAS Controller IntelliSpeed control of the VFD based on stages of cooling. Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10. Simplicity SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. BACNet MS/TP, Modbus and N2 communication card Standard Unit Controller: Simplicity Control Board An Integrated Low-Ambient Control, Anti-Short Cycle Protection, Lead-Lag, Fan On and Fan off Delays, Low Voltage Protection, On-Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 F outdoor ambient without additional components or intervention. Safety Monitoring - Monitors the High and Low-Pressure Switches, the Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 05/29/2018

Project Name: GCS-Southeast Series 20 (15-25 Ton Package) N540 Single Package R-410A AC with Reheat Page: 2 Unit Model #: J20ZRN30R2C5FCA4M1 Quantity: 1 Tag #: RTU- Auditorium System: J20ZRN30R2C5FCA4M1 on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition Failures, Safety Lockouts and Repeated Limit Switch Trips. Warranty One (1) Year Limited Warranty on the Complete Unit Five (5) Year Warranty - Compressors and Electric Heater Elements Ten (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 05/29/2018

Series 20 (15-25 Ton Package) N540 Single Package R-410A AC with Reheat Page: 3 Project Name: GCS-Southeast Unit Model #: J20ZRN30R2C5FCA4M1 Quantity: 1 Tag #: RTU- Auditorium System: J20ZRN30R2C5FCA4M1 Consolidated Drawing Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 05/29/2018

Series 20 (15-25 Ton Package) N540 Single Package R-410A AC with Reheat Page: 4 Project Name: GCS-Southeast Unit Model #: J20ZRN30R2C5FCA4M1 Quantity: 1 Tag #: RTU- Auditorium System: J20ZRN30R2C5FCA4M1 Component Locations Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 05/29/2018