University of Wisconsin - Whitewater Universal Design Guidelines

Similar documents
ADA Checklist Transient Lodging, Hotels, Motels, Inns, Boarding Houses, Dormitories and similar facilities

Number of persons with a disability that live with a disability in your community?

Facilities Procedure for Accessibility or Compliance Related Requests:

ADA Checklist AIRPORTS

Purpose of the Act. Learning Objectives. Latest with DOJ. Latest with DOJ. Texas Registered Accessibility Specialists Association

UNIVERSITY OF MANITOBA PROCEDURE

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

Abbreviated Accessibility Checklist (Reception, Telephones, and Emergency Procedures) Reception Telephones

University of Delaware

Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev.

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1

Use a minimum loading pad 6' curb length of a hard surface to connecting curb and sidewalk.

Solutions and Cost Estimates Johnson Gill Annex and Courthouse 1 Kings Highway Middletown, NJ

Plumbing Guidelines 2012 IBC/ANSI A

Aging-In-Place Remodeling Checklist

For the Lifespan: The Caregiver Guide Module 4 The Accessible Home

Planning Guide for the Refurbishment, Renovation, or Construction of Instructional Space Environments

Unit # E ± 1,200 SF Width ± 20' Depth ± 60'

Home Safety Checklist From Adaptive Remodeling Solutions, LLC Monona, WI

Unit # H ± 2,000 SF Width ± 25' Depth ± 80'

Chapter 6: Plumbing Elements and Facilities. 603 Toilet and Bathing Rooms Wheelchair Accessible Compartment

Home Evaluation Questionnaire for PLOF

Building Regulations Part M 2004 Access To And Use Of Buildings Checklist Of Provisions/Areas For Consideration

MINUTES JOINT MEETING FINANCE/AUDIT AND CONSTRUCTION COMMITTEES UNIVERSITY OF SOUTHERN INDIANA BOARD OF TRUSTEES. July 6, 2006

MCB/DDS Partnership Orientation & Mobility/Low Vision Services

About the instructor: Presentation by: Scott A. Anderle, PT, CAPS. Physical Therapist for 20+ years. CAPS-Certified Aging-in-Place Specialist

EQUIPMENT GUIDE LIST - CHAPTER

Campus Sign Plan. Adopted by the Campus Planning Committee Adopted: June 26, 2006 Revised: April 14, 2016

difficulty arising from the seating. Consider using a suitable location as a quiet sick bay.

Electrical Information

FOOD SERVICE May 6, 2016

Pty. Ltd. 1. Classroom Cleaning Daily Wkly Mthly Other Vacuum and mop all hard surfaces Vacuum and spot clean all carpeted areas Remove any cobwebs Cl

TRINITY LUTHERAN SCHOOL RENOVATIONS

Safe at Home. Suggestions for Homeowner Created in partnership with the Administration on Aging. Assessor: Assessor: Homeowner Name: Address:

Bath Planning Worksheet

Unit # 1038 ± 900 SF Width ± 15' Depth ± 60'

Getting Started. Gather Ideas. Visit our Showroom. What s next? Page 1 of 7

Structure type: (2 story, ranch, bi-level, split level, I½ story, apt, duplex, town house) Location of house (rural, semi rural, suburban, urban)

OPERATIONS & MAINTENANCE PLAN. 571 Vance Ave Memphis, TN

Safe at Home. Suggestions for Homeowner Created in partnership with the Administration on Aging. Assessor: Assessor: Homeowner Name: Address:

Athens Technical College Safety Manual

Proposed Board Action. Background Information

Emergency Evacuation Procedures

AGING IN PLACE CHECKLIST Use this checklist to identify fall hazards and accessibility for the homeowner and family members.

REAR. Exit 5'-9" 6'-1" 8'-3" 6'-1" Freezer Entrance Stall

Revision th July The Pinnacle Apartments. Standard Specifications and Finishes

GENERAL ASSIGNMENT CLASSROOM DESIGN STANDARDS

Seniors Home Program

Universal Design Checklist

FOOD SERVICE May 6, 2016

PARKLET PROPOSAL PACKAGE & PROCESS

HOW TO USE THIS CHECKLIST TO IDENTIFY HOME HAZARDS TO PREVENT FALLS

SCOPE OF WORK. 506 N. Chadbourne Ave, San Angelo, TX. 1. Build and outfit kitchen are in accordance with established drawing

Creating the Accessible Home A One-Day Seminar

7/14/2016 CITY HALL ADA ENHANCEMENT/REMODEL ACTION PLAN 1978 Construction

CUSTODIAL CUSTOMER SERVICE GUIDE

Michigan State University Barrier-Free/Accessibility Project Status Summary March 2017

Beaufort County Community College. Maintenance and House Keeping Plan

Plot # R019A ± 74' ± 74' ± 65' Plot # R019A LEASE OUTLINE DRAWING GROSS LEASABLE AREA ± 4,631 S.F. DEMISING FRONT WIDTH DEPTH ± 13' ± 32' Lease Line

DIVISION 12 FURNISHINGS FURNISHINGS

New School Construction: Safe School Opening. OAR and IOR Joint Training February 17, 2005

BATHROOM REMODELING CONVERSATION SHEET

Access Statement Seagrass Cottage 29 Longbeach Drive Beadnell NE67 5EG. Pre-Arrival. Parking. Entrance to Property. Prepared 24.4.

Draft. Security Study. Germantown School District Germantown, WI. PRA Project # February 2014

room data sheet TAMURA HOUSE 396 POWELL STREET, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Paradise Marketplace. Unit # AOP +/- 1,600 SF +/- 12' +/- 11' +/- 8' 11'-7" +/- 85' +/- 74' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width.

Unit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information

6. RECREATION AND OPEN SPACE ELEMENT

Virginia Department of Planning and Budget Project Request Justification


Conference-Seminar Table & chair Case Study (tiered) Swivel chairs, Continuous Counter Top

Paradise Marketplace REAR FRONT. Unit # AOH +/- 1,700 SF +/- 20' +/- 85' +/- 85' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width. Depth

Emergency Response Team (ERT) Areas of Accountability

Special attention should be given to new students, to students with special needs and to students enrolled in visiting classes.

P A R K L E T 2016 PILOT PROJECT

Universal Design Recommendations for Accessible Housing. Mauricio A. Lizama, Ph.D., ATP

RE THINKING WASTE, RECYCLING, AND HOUSEKEEPING. A leaner Green

CLINICAL SERVICES ADMINISTRATION (214)

Corporate Report. Further, that Legal Services be directed to prepare the necessary amendments to the City s Delegation By-law.

NECC Strategic Plan Goal Team 1: Develop a Comprehensive Campus in Downtown Lawrence

11 February CAMPUS MASTER PLAN UPDATE Focus Group - Design Guidelines

A. Section Masonry Assemblies: Anchor placement in masonry.

Bethlehem University 2008 Projects Summary

room data sheet GASTOWN HOTEL 110 WATER STREET, VANCOUVER, BC 1/11 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

LOS ANGELES UNIFIED SCHOOL DISTRICT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY PROCEDURE

room data sheet MARBLE ARCH HOTEL 518 RICHARDS STREET, VANCOUVER, BC 1/14 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

DUQUESNE UNIVERSITY EMERGENCY EVACUATION GUIDELINES

New Brunswick Campus Operations Service Guide. Maintenance repair or replacement in

EMERGENCY ACTION PLAN

AGING IN PLACE Simple changes to make now to help you live in your home longer, remain independent, decrease the risk of falls, and maintain function.

Facilities Management Manual. How to respectfully maintain the residence halls and other Central State University facilities

Cleaning Service Levels

CONSTRUCTION DOCUMENTS CHECKLIST

PHYSICAL FACILITIES Consultant s Handbook Division 01 General Special Requirements Instructional Spaces. Page 1 of 9

Lowe s Accessible Home LIVE RIGHT. Solutions for life s changing needs

DUNCAN STUDENT CENTER. Emergency Action Plan

Accessible Home Design and Remodel Checklist

APPROVED: Dayroom: Space for activities that is situated immediately adjacent to the youth sleeping areas and separated from them by a wall.

TOILET ACCESSORIES. Custodial Services Residential Custodial Services Academic Custodial Services (302) (302) (302)

HOME EVALUATION & ASSESSMENT FOR INDEPENDENT LIVING & ACCESSIBILITY

Transcription:

University of Wisconsin - Whitewater Universal Design Guidelines The purpose of these guidelines is to foster good design and discussion that fully encompasses the principals of Universal Design (UD) into the development of building design. UWW sees the ADA, ADAAG, ADAAA 2009, the Rehabilitation Act of 1973, local, state and federal building codes as minimum guidelines and focuses on equal access and functional ability. UWW also incorporates the idea of social equitability into design. Social equitability requires a closer look at the programming purpose of spaces to ensure that individuals with disabilities are able to access the full range of services, programming, and social use of spaces with minimal accommodations. 1. Path of entry 2. Doorways and entrances 3. Door openers 4. Bathrooms 5. Hallways 6. Areas of service 7. Furniture 8. Additional resources 9. Justification 1 Path of Entry is the path of entry from the parking area to the entrance of the building, service area or program area. This must be assessed as part of any new construction or remodel of any primary service area. 1.1 New or Remodeled Construction 1.1.1 An assessment of accessible parking area and needs must be completed 1.1.2 A review of proposed parking areas will be needs to be done to determine if there are any barriers on the entrance route 1.1.3 All curb cuts and cross walks need to be assessed to determine if they meet code, if not a plan needs to be developed 1.1.3.1 Truncated domes should be placed in where needed 1.1.4 Appropriate signage needs to be incorporated if all entrances are not accessible telling individuals where the closest accessible entrance will be 2 Doorways and Entrances 2.1 Building Entrances 2.1.1 Design for zero entry doorways: no steps or other physical barriers to the entrance 2.1.2 If ramped a 1:16 minimum slope 2.1.3 One set of doors per entrance must have an electronic pushbutton or proximity card readers for automatic opening

2.1.4 Doorways should have 42 of clearance, not including framing 2.1.5 Preference to have 2 entrances with access for flow of pedestrian traffic 2.2 Interior Entrances 2.2.1 Entrances into areas of common areas, major activity or services need to have 40 of clearance not including framing 2.2.2 Primary entrances need to have an accessible opening option, electronic pushbutton or proximity card readers for automatic opening 2.2.2.1 Exception is when the doors are left open during business hours 2.2.3 New interior doors should have 36 of clearance not including framing or the door 2.2.4 For remodels where doorframes are not being replaced utilize drop hinges to increase clearance to 32 3 Door Openers 3.1 Consideration for employment, How would a staff or student employee open for the day independently? 3.1.1 electronic pushbutton or proximity card readers for automatic opening should be placed on the wall or stand at 36 center. 3.1.1.1.1 Ensure the location of hardware for door opener is approachable by side or front access and located on level hard surface 4 Bathrooms 4.1 Group bathrooms 4.1.1 Entrances 4.1.1.1 When possible avoid building doors. Utilize design that creates zero door entries 4.1.1.2 Avoid double door entries. Design for single door entry. 4.1.1.3 Entries should have a minim of 40 clearance, not counting framing 4.1.1.4 The entrance way of accessible vestibule should be at least 48 wide, with a 60 turn diameter 4.1.2 During the design phase all wall mount amenities must be drawn 4.1.2.1 Ensure social equitability by incorporating mirrors, hooks, and vanity space that are accessible 4.1.2.2 Preference for at least 1 full length mirror 4.1.3 Electronic pushbutton or proximity card readers for automatic opening should be planned for and wired 4.1.4 When possible use motion sensor faucets when deemed appropriate 4.1.5 When possible use dual flush systems for conservation of water 4.1.6 Avoid toilet paper dispensers that require reaching under, preference for side roll dispensers with easy continuous roll dispensing 4.1.7 Utilize air driers or automatic paper towel dispensers 4.1.8 Ensure that appropriate blocking is incorporated into all bathroom builds. This allows for grab bars to be added at a later date if needed.

4.2 Unisex Bathroom or Residence Hall Bathrooms 4.2.1 Recommendations see UNC Center for UD bathroom tech sheet 4.2.1.1 http://www.design.ncsu.edu/cud/pubs_p/docs/qap_tech_screen.pdf 4.2.2 During the design phase all wall mount amenities must be drawn 4.2.2.1 Ensure social equitability by incorporating mirrors, hooks, vanity space and other amenities that are accessible 4.2.2.2 Preference for at least 1 full length mirror per unit 4.2.2.3 Avoid cabinetry under the sink 4.3 Remodeling Bathrooms Group or Unisex 4.3.1 When possible design for a zero door entry 4.3.2 When possible remove double doors 4.3.3 Electronic pushbutton or proximity card readers for automatic opening should be planned for and wired to increase access 4.3.4 Add amenities to increase social equitability 4.3.5 Recommendations see UNC Center for UD bathroom tech sheet 4.3.5.1 http://www.design.ncsu.edu/cud/pubs_p/docs/qap_tech_screen.pdf 5 Primary Hallways 5.1 6 wide 5.2 Paths of entry and footprints inside major service areas 42 minimum 6 Area of Service 6.1 An area of service is defined as a space providing a service to students, staff or faculty. This can include: information centers, eating areas, academic office, classroom, or primary office functions (admissions, advising, financial aid, etcetera). 6.1.1 Circulation Areas 6.1.1.1 Desk or circulation desks should follow the 2/3 rule. Two thirds of the surface area should be at 30 and 1/3 should be at 34. 6.1.1.2 Circulation desks or entrance desks should have a clear line of sight to guests and students. 6.1.1.3 Avoid placing the computer or other equipment in the line of sight to the door or where a guest would approach. 6.1.1.4 Pamphlet racks should be placed in accessible areas with easy side and front approach. Avoid placing print materials on counters or hung above 42 on a wall. 6.1.1.5 Seating behind the primary desk should be accessible for an employee who might use a wheelchair. 6.1.1.5.1 When creating the 60 of turning diameter in front of the circulation desks or other service spaces, include all possible seating and furniture in the drawing. The 60 diameter is based on a functioning office, not a cleared drawing. 6.1.1.6 Preference for 6 hallways in new or remodeled construction to allow 2 wheelchairs to pass.

6.1.1.7 If providing access to computers or other resources in the primary area ensures that there is an accessible computer station, work areas, or other technology. 6.1.1.7.1.1 Avoid under counter mounted computer monitors 6.1.1.8 Utilize motion sensors for lights when possible 7 Furniture 7.1 Equity of furniture 7.1.1 If a large lecture hall has tablet arms, then the accessible seating must include tables (fixed or movable) that create writing surfaces. This may mean exceeding the 30 seating width to accommodate a table and a wheelchair. 7.1.2 When purchasing new furniture 7.1.2.1 Seating provide a variety of seating options within a building or classroom 7.1.2.1.1 With and without arms, with and without wheels, sled based seating for stability 7.1.2.2 Tables tables on wheels or that are easily movable are preferred 7.1.3 Computer labs all computer labs need to have accessible stations and technology 8 Architects, designers, and contractors can also refer to the State of WI, Division of State Facilities for additional accessibility guidelines: http://www.doa.state.wi.us/dsf/masterspec_view_new.asp?catid=14&locid=4 UWW expects that design either internal or external will adhere to the strictest or most accessible guideline. 9 Justification 9.1 UWW expects that all new construction and remodel projects will meet the minimum building and accessibility guidelines. However, UWW is striving to achieve a higher level of accessibility and equitability therefore: 9.1.1 If the project will not be incorporating the UD guidelines into new or remodeled space, the project manager is responsible to put in writing, in memo format, the following 9.1.2 Rationale why the design is not incorporating UD 9.1.2.1 If the rationale is related to cost, then the program manager must show that the cost of UD will exceed 20% of the total budget 9.1.3 How alternative means of access will be met? 9.1.4 How the unit will bear the cost of accommodations on an as needed basis? 9.2 Justifications must be submitted in writing to the Vice Chancellor of Administrative Affairs and the ADA Coordinator prior to project approval

Committee Participants: Elizabeth Watson, Chair of Universal Design Committee and Director of Center for Students with Disabilities Randy Marnocha, Vice Chancellor of Administrative Affairs Eric Barber, Human Resources ADA Coordinator Connie Wiersma, Center for Students with Disabilities Frank Bartlett, Interim Director of Residents Life Michael O Connor, University Center Building and Grounds Supervisor David Dorgan, Facilities Engineer Elizabeth Ogunsola, Assistant to the Chancellor for AA/EEOC Last modified on 7/15/2009