Mold/Moisture Control Case Study

Similar documents
HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1. Contextual Reminder

Dehumidifying with Dedicated Outdoor Air

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Benefits Offered by Passive Dehumidification Wheel Speed Control

7. MECHANICAL SYSTEM DESIGN

BUILDING VENTILATION GUIDE FOR LG HVAC SYSTEM INSTALLATION

BUILDING VENTILATION GUIDE

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

DADANCO Technical Paper

Adding More Fan Power Can Be a Good Thing

Chapter 6 ALL-AIR HVAC SYSTEMS 6.1 CONTEXT

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Uniform Dwelling Code 2017 Updates SPS 323

HVAC DISTRIBUTION and DELIVERY SYSTEMS

APPLICATION GUIDE BEAMS

CHAPTER 4. HVAC DELIVERY SYSTEMS

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

HVAC Mandatory Provisions Part II, Page 1

Munters Heat Exchangers

b.) Technical Information:

DACC Health Sciences Building Air Handler Assessment/Study

NON-REVERSING, 100% OUTSIDE AIR HEAT PUMP FOR HEATING AND COOLING

Modular Active. Chilled. Beams

Pharmaceutical Facility Design

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

Chilled Beam and Radiant Cooling Basics. Salt Lake City, UT ASHRAE Chapter December 2013 Nick Searle

Impacts of Optimized Cold & Hot Deck Reset Schedules on Dual Duct VAV Systems - Theory and Model Simulation

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

HVAC 101. H V A C S y s t e m s

nzeb office building

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

PhEn-602 Pharmaceutical Facility Design. Notes #7 J. Manfredi

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery

Heat pump and energy recovery systems

TDSHS Air Change Requirements and the Basics of Psychrometrics. Presented by: Aric Murray December 06, 2013

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

HVAC Optimization with Cold Air Distribution

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

Implementation of the Laboratory Air Handling Unit Systems (LAHU)

The ultimate fresh air solution.

SESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

Achieving Dry Outside Air in an Energy-Efficient Manner

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

Humidity Control Design Tips. R. Mark Nunnelly, PE, CxA, LEED AP President

IAQ Building Education and Assessment Model (I-BEAM)

Executive Summary. OA/person (cfm/p) Private and open offices, Classrooms, Building as designed

4. OVERVIEW OF MECHANICAL SYSTEM

Southwest Air Conditioning

Museum Archive Dehumidification in Hot & Humid Climates

Comfort and health-indoor air quality

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

Temperature Control and Zoning of UFAD Systems

Effects of Kitchen Ventilation on Residential Dwellings

Do All DOAS Configurations Provide the Same Benefits?

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

Civil Engineering Building

Job Name Control Systems Description Date

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

Relative Humidity in Schools Jim Cummings and Chuck Withers

Understanding Ventilation in Hot Humid Climates by Joseph Lstiburek

Design Options For HVAC Distribution System. Course Content

CHAPTER IV AIR DISTRIBUTION AND BALANCE

Dehumidification: Energy Efficiency Comparisons

Building Systems: HVAC

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Ventilation and Humidity Control in Army Barracks Using DOAS for Better Indoor Air Quality and Energy Conservation

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

AMCA Webinar High Performance Air Systems Presented by:

Designing Energy Efficient Outdoor Air Systems

Kings County Jail Expansion Phase 3 Rational Analysis of Smoke Control System

Desiccant Dehumidifier

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

Technical Assignment 1

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

product application data PERFECT HUMIDITY DEHUMIDIFICATION SYSTEM

Air System Sizing Summary for Lobby System Project Name: Existing Lobby 04/04/2005 Prepared by: psuae

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Continuous Commissioning of Commercial Kitchen and Dining Facilities Case Study

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

Mechanical Ventilation : How much is enough? Can there be Too Much? Subrato Chandra Resnet Meeting 2/20/07

Residential Makeup Air Systems & Requirements

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

Continuous Commissioning Report

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Jim Aswegan Chief Engineer

Transcription:

Mold/Moisture Control Case Study Presented by Boggarm S. Setty, P.E., FASHRAE Setty & Associates, Ltd. www.clima2005.ch Clima 2005 Lausanne Solothurnstrasse 13 CH-3322 Schönbühl Switzerland th 8 REHVA World Congress Phone +41 (31) 852 13 00 Fax +41 (31) 852 13 01 Email: info@clima2005.ch

Introduction Mold and mildew formation across the country Issues are costly in institutional and commercial buildings Optimum designs are pursued in envelope systems, dew point control and optimization of HVAC systems Paper discusses mold and moisture issues in a High School

Case Study-Liberty High School, Bealton, VA Located 30 miles southwest of Washington, DC Mold growth in classrooms, high latent heat Issues relating to mold, condensation, overcooling and localized cooling Moisture intrusion leading cause of mold growth HVAC system identified as promoter of mold growth

Existing Classroom Fan Coil Unit Configuration Ceiling mounted fan coil units Not capable of dehumidifying air Fresh air drawn through unit not properly dehumidified Control of units to promote fresh air into the building continuously Outdoor louvers connected to the fan coil unit leak Two-pipe system does not provide heating/cooling simultaneously

Existing Passive Air System Fresh air drawn from fan coil unit Outside air retrieved through gravity ventilator Promotes condensation in ceiling spaces and creates negative pressure in building Fresh air is dehumidified in ceiling space

Existing Passive Air Relief System

Fan Coil Retrofit Turn pipe chilled water cooling coil with electric heat Convert existing two-pipe system to four pipe system Locate electric heating coil downstream of the cooling coil Retrofit ductwork for proper air circulation

Dedicated Outside Air Unit Conditions fresh air 100%, up to 50oF / +10oC dew point Hot water reheat to heat the air up to 70oF / +21oC Separate duct system supplies air to individual classrooms Intakes with relief and exhaust fans Self-contained controls maintain 2 Pascal's position pressure in space

Dedicated Outside Air Unit Run around coil provides necessary reheat to space Discharge sensor maintains 50oF / +10oC dew point

Run Around Heat Recovering Units

Moisture Reduction Calculations Window and door infiltration Total LF crack = 2,100 Use 50% of total LF crack = 1,050 CFM/LF = 77 ft3/hr-lf = 77/60 ft3/min LF Q = 77/60 ft3/min LF x 1050 LF = 1,348 cfm Leakage through FCU O.A. intakes 77 louvers Wind velocity = 16 mph Use 8 mph ASHRAE 2001 Chapter 26 Eq. 29 Q = CACUAU = Airflow through air inlet Q = Airflow in cfm CU = Effectiveness of opening (CU assumed.25) A = Free area U = Wind speed, mph CU = Conversion of units = 88.0

Moisture Reduction Calculations Q = 88.0 x.25 x 10.64 ft2/louver x 8 mph = 1,873 cfm/louver Each louver has a damper therefore assume 15% leakage 1,873 x.15 x 77 louvers/2 = 10,817 cfm Therefore front lobby infiltration Assume doors are 100% open during peak use Four sets of doors, each 6 ft x 7 ft high Total open area: 4 x 6 ft x 7 ft = 168 ft2 Q = 88.0 x.25 x 10.68 ft2 x 8 = 29,568 cfm The new design eliminates the O.A. through the FCU therefore, 10,817 cfm infiltration has been eliminated. The pressure inside the school building will be maintained positive to the O.A. Therefore, the infiltration will be reduced essentially to zero.

Conclusions Design of a separate fan coil system DOAS system with 100% fresh air capability Proper dew point control Maintain positive pressure of 2 Pascal's in building Commissioning to keep building dry during construction Minimize moisture intrusion and eventually mold growth

Questions and Answers Setty & Associates, Ltd. www.setty.com