SITE PLAN - MINI U STORAGE LOCATED IN A PORTION OF THE SOUTHWEST QUARTER OF SECTION 15, TOWNSHIP 6 SOUTH, RANGE 66 WEST OF THE 6th P.M. 18901 LONGS WAY, PARKER, CO 80134 SITE DEVELOPMENT DATA: SITE ACREAGE: 2.787 AC. (121,352.6 SF) EXISTING ZONING: MORAN PD - LIGHT INDUSTRIAL DEVELOPMENT SCHEDULE: SUMMER 2015 PROPOSED LAND USE: SELF STORAGE SITE ADDRESS: 18901 LONGS WAY STATE PARCEL NUMBER: 2233-153-00-002 AREA COVERAGE PROPOSED BUILDING : 57,914.6 S.F. 47.7 % PROPOSED PAVEMENT: 29,127.4 S.F. 24.0 % PROPOSED LANDSCAPE: 33,348.3 S.F. 27.5 % PROPOSED SIDEWALK: 962.3 S.F. 0.8 % VICINITY MAP 1" = 1000' REQUIRED PROPOSED SETBACKS: FRONT: 40 FT. 40.1 FT. SIDE: 25 FT. 25.7 / 32.2 (E/W) FT. REAR: 7.5 FT. 7.5 FT. TOTAL PARKING REQUIRED: 9 SPACES 10 SPACES (1 SPACE / 10,000 GSF) TOTAL ACCESSIBLE PARKING: 1 SPACES 1 SPACES TOTAL BICYCLE PARKING: 2 SPACES 2 SPACES ALLOWED BUILDING HEIGHT: 35' - 0" MAX. 35' - 0" NOTES: 1. OWNER RECOGNIZES THE EFFECTS OF PASSAGE OF AIRCRAFT IN THE AIRSPACE ABOVE THE PROPERTY THAT IS THE SUBJECT OF THIS SITE PLAN INCLUDING, BUT NOT LIMITED TO: NOISE, SMOKE, DUST, FUMES AND VIBRATION. LEGAL DESCRIPTION: LOT 1, SHEET INDEX: 1 COVER SHEET 2 SITE PLAN 3 GRADING & UTILITY PLAN 4 LANDSCAPE PLAN 5 LANDSCAPE DETAILS 6 PHOTOMETRIC PLAN 7 BUILDING ELEVATIONS 8 BUILDING ELEVATIONS 9 BUILDING ELEVATIONS 10 BUILDING ELEVATIONS 11 BUILDING ELEVATIONS 12 BUILDING ELEVATIONS 13 BUILDING ELEVATIONS OWNER: DAHN CORPORATION 18552 MacARTHUR BLVD., #495 IRVINE, CA 92612 CONTACT: ROBERT BRADLEY PHONE: (949) 752-1282 ARCHITECT: HPI 115 22nd STREET NEWPORT BEACH, CA 92663 CONTACT: DAPHNE ROBINSON PHONE: (949) 675-6442 CIVIL ENGINEER: THE DIMENSION GROUP 5600 S. QUEBEC ST, SUITE 210C GREENWOOD VILLAGE, CO 80111 CONTACT: CHAD A. WHEELER, PE PHONE: (720) 536-3181 LANDSCAPE ARCHITECT: JUMP DESIGN COMPANY 1733 S. CLARKSON STREET DENVER, CO 80210 CONTACT: TOM JUMP PHONE: (303) 282-0463 COVER SHEET MINI U STORAGE JOB NO. C4075 APRIL 28, 2015 SHEET 1 OF 13 ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING PLANNING 5600 S. Quebec Street, Suite 310B, Greenwood Village, Colorado 80111 TEL: 720.536.3180 www.dimensiongrp.com
SITE PLAN - MINI U STORAGE LOCATED IN A PORTION OF THE SOUTHWEST QUARTER OF SECTION 15, TOWNSHIP 6 SOUTH, RANGE 66 WEST OF THE 6th P.M. 18901 LONGS WAY, PARKER, CO 80134 GRAPHIC SCALE 30 0 15 30 1 INCH = 30 FEET NOTE KEYS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 BUILDING 6" MEDIAN CURB AND GUTTER CONCRETE PAN PRIVATE SIDEWALK (4" THICK) PAINTED PEDESTRIAN CROSSWALK 9' x 18' STANDARD PARKING STALL 10' x 18' END PARKING STALL 9' x 18' HANDICAP PARKING STALL 8' x 18' LOADING ZONE HANDICAP ACCESSIBLE RAMP HANDICAP VAN ACCESSIBLE POLE-MOUNTED SIGN VERTICAL LIFT GATE TRASH ENCLOSURE LANDSCAPE AREA (SEE SHEET 4) MONUMENT SIGN (SIGNAGE BY SEPARATE PERMIT) PIPE BOLLARD BICYCLE RACK (2 BIKES) 30" x 30" STOP SIGN INTERSECTION SIGHT TRIANGLE 20-FT WATER EASEMENT BY SEPARATE DOCUMENT LOT LINE 4 STALL COUNT NOTES: 1. SHADED AND/OR DASHED LINEWORK, OTHER THAN EASEMENTS, INDICATES EXISTING IMPROVEMENTS. SITE PLAN MINI U STORAGE JOB NO. C4075 APRIL 28, 2015 SHEET 2 OF 13 ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING PLANNING 5600 S. Quebec Street, Suite 310B, Greenwood Village, Colorado 80111 TEL: 720.536.3180 www.dimensiongrp.com
SITE PLAN - MINI U STORAGE LOCATED IN A PORTION OF THE SOUTHWEST QUARTER OF SECTION 15, TOWNSHIP 6 SOUTH, RANGE 66 WEST OF THE 6th P.M. 18901 LONGS WAY, PARKER, CO 80134 GRAPHIC SCALE 30 0 15 30 1 INCH = 30 FEET GRADING AND UTILITY PLAN MINI U STORAGE JOB NO. C4075 APRIL 28, 2015 SHEET 3 OF 13 ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING PLANNING 5600 S. Quebec Street, Suite 310B, Greenwood Village, Colorado 80111 TEL: 720.536.3180 www.dimensiongrp.com
E. DRANSFELDT RD. SITE PLAN - MINI U STORAGE LOCATED IN A PORTION OF THE SOUTHWEST QUARTER OF SECTION 15, TOWNSHIP 6 SOUTH, RANGE 66 WEST OF THE 6th P.M. 18901 LONGS WAY, PARKER, CO 80134 WAY S. PROGRESS LONG'S WAY PROPOSED TURF IS BUFFALO GRASS SEE SHEET 5 FOR PLANTING DETAILS AND NOTES. LANDSCAPE PLAN MINI U STORAGE JOB NO. C4075 APRIL 28, 2015 SHEET 4 OF 13 PLANNING & LANDSCAPE ARCHITECTURE Jump Design Company 1733 S. Clarkson Street Denver, Colorado 80210 303.282.0463 fax 282.0473 ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING PLANNING 5600 S. Quebec Street, Suite 310B, Greenwood Village, Colorado 80111 TEL: 720.536.3180 www.dimensiongrp.com
SITE PLAN - MINI U STORAGE LOCATED IN A PORTION OF THE SOUTHWEST QUARTER OF SECTION 15, TOWNSHIP 6 SOUTH, RANGE 66 WEST OF THE 6th P.M. 18901 LONGS WAY, PARKER, CO 80134 TOWN OF PARKER TREE PLANTING DETAIL TOWN OF PARKER TREE PLANTING DETAIL - SLOPES USE 3 GUY ASSEMBLIES FOR EVERGREENS AND TREES OVER 3" CAL. ROOT COLLAR VISIBLE TOP MOST ROOTS WITHIN 1"-2" OF EXISTING/ FINAL GRADE NOTE: BROKEN OR CRUMBLING ROOTBALLS WILL BE REJECTED PRUNE ALL DEAD OR DAMAGED WOOD AFTER PLANTING. USE GROMMETED NYLON TREE STRAPS AT END OF WIRE USE 3 GUY ASSEMBLIES FOR EVERGREENS AND TREES OVER 3" CAL. ROOT COLLAR VISIBLE TOP MOST ROOTS WITHIN 1"-2" OF EXISTING/ FINAL GRADE NOTE: BROKEN OR CRUMBLING ROOTBALLS WILL BE REJECTED PRUNE ALL DEAD OR DAMAGED WOOD AFTER PLANTING. USE GROMMETED NYLON TREE STRAPS AT END OF WIRE 2-4" OF ORGANIC MULCH APPLIED OVER PLANTING AREA AND AWAY FROM TRUNK EXISTING GRADE 12 GAUGE GALVANIZED WIRE 24'' x 3/4'' P.V.C. MARKERS (TYPICAL) OVER WIRES. 2-4" OF ORGANIC MULCH APPLIED OVER PLANTING AREA AND AWAY FROM TRUNK EXISTING GRADE 12 GAUGE GALVANIZED WIRE 24'' x 3/4'' P.V.C. MARKERS (TYPICAL) OVER WIRES. BACKFILL WITH UNAMENDED TOPSOIL FROM HOLE BURLAP, ROPE, AND WIRE REMOVED FROM TOP 1/2 OF ROOT BALL AT MINIMUM ROOTBALL SITTING DIRECTLY ON TOP OF UNDISTURBED SOIL TREATED WOOD POST USE 2 GUY ASSEMBLIES FOR TREES UNDER 3" BACKFILL WITH UNAMENDED TOPSOIL FROM HOLE BURLAP, ROPE, AND WIRE REMOVED FROM TOP 1/2 OF ROOT BALL AT MINIMUM ROOTBALL SITTING DIRECTLY ON TOP OF UNDISTURBED SOIL TREATED WOOD POST W/ USE 2 GUY ASSEMBLIES FOR TREES UNDER 3" UNAMENDED TOPSOIL ADDED TO EXISTING GRADE ON DOWN HILL SIDE EXISTING GRADE SLOPE SIDED HOLE IS 3 TIMES AS WIDE AS THE ROOTBALL DIA. SLOPE SIDED HOLE IS 3 TIMES AS WIDE AS THE ROOTBALL DIA. EXCAVATE PLANTING HOLES WITH SLOPING SIDES. MAKE EXCAVATIONS AT LEAST THREE TIMES AS WIDE AS THE ROOT BALL DIAMETER AND NO DEEPER THAN THE DISTANCE FROM THE TOP MOST ROOT IN THE ROOT BALL TO THE BOTTOM OF THE ROOT BALL TO ALLOW FOR SETTLING. DO NOT DISTURB SOIL AT BOTTOM OF PLANTING HOLES, BUT DO SCORE THE SIDES OF THE PLANTING HOLE. THE PLANTING AREA SHALL BE LOOSENED AND AERATED AT LEAST THREE TO FIVE TIMES THE DIAMETER OF THE ROOT BALL. BACKFILL SHALL CONSIST OF EXISTING ONSITE SOIL- NO AMENDMENTS SHALL BE USED UNLESS OTHERWISE SPECIFIED. TREES SHALL BE PLANTED WITH THE ROOT COLLAR/FLARE VISIBLE ABOVE GRADE AND TWO OR MORE STRUCTURAL ROOTS LOCATED WITHIN THE TOP 1-2" OF THE ROOT BALL/FINISHED GRADE MEASURED 3" TO 4" FROM THE TRUNK. THIS INCLUDES TREES THAT ARE SET ON SLOPES (SEE SLOPE PLANTING DETAIL). TREES THAT DO NOT HAVE A VISIBLE ROOT COLLAR SHALL BE REJECTED. DO NOT COVER THE ROOT BALL WITH SOIL. WHEN THE ROOT BALL WILL REMAIN INTACT, CUT OFF BOTTOM 1/4 OF THE WIRE BASKET BEFORE PLACING TREE IN HOLE; CUT OFF REMAINDER OF BASKET AFTER TREE IS SET IN HOLE, REMOVE BASKET ROOT BALL ON ALL TREES. REMOVE ALL NYLON TIES, TWINE, ROPE AND BURLAP. REMOVE UNNECESSARY PACKING MATERIAL. FORM SOIL INTO A 3" TO 5" WATERING RING (SAUCER) AROUND THE PLANTING AREA. THIS IS NOT NECESSARY IN IRRIGATED TURF AREAS. APPLY 2" TO 4" DEPTH OF SPECIFIED MULCH OVER PLANTING AREA AND INSIDE SAUCERS, AWAY FROM TRUNK. TOWN OF PARKER PLANTING DETAIL- SHRUBS PRUNE DAMAGED OR DEAD WOOD PRIOR TO PLANTING. PLANT SHRUB 2" HIGHER THAN ORIGINAL GROWN GRADE DIG PIT TWICE AS WIDE AS THE CONTAINER APPLY SPECIFIED MULCH 3"-4" ABOVE FINISH GRADE AS SHOWN LOOSEN SIDES OF ROOTBALL NOTES: - BACKFILL AND WATER-IN THOROUGHLY - BROKEN ROOTBALLS WILL BE REJECTED STAKING AND GUYING OF TREES IS OPTIONAL IN MOST PLANTING SITUATIONS. IN AREAS OF EXTREME WINDS, OR ON STEEP SLOPES, STAKING MAY BE REQUIRED TO STABILIZE TREES. STAKING AND GUYING MUST BE REMOVED WITHIN 1 YEAR OF PLANTING DATE. TREE WRAP IS NOT TO BE USED ON ANY NEW PLANTINGS, EXCEPT IN LATE FALL PLANTING SITUATIONS, AND THEN ONLY AFTER CONSULTATION WITH THE TOWN ARBORIST. RESETTLING OF IMPROPERLY PLACED TREES WILL ONLY BE ALLOWED IF IT IS DETERMINED THAT DOING SO WILL IN NO WAY COMPROMISE THE ROOT BALL AND SHALL ONLY BE DONE WITH APPROVAL OF THE TOWN ARBORIST. LANDSCAPE PLAN MINI U STORAGE JOB NO. C4075 APRIL 28, 2015 SHEET 5 OF 13 PLANNING & LANDSCAPE ARCHITECTURE Jump Design Company 1733 S. Clarkson Street Denver, Colorado 80210 303.282.0463 fax 282.0473 ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING PLANNING 5600 S. Quebec Street, Suite 310B, Greenwood Village, Colorado 80111 TEL: 720.536.3180 www.dimensiongrp.com
SITE PLAN - MINI U STORAGE LOCATED IN A PORTION OF THE SOUTHWEST QUARTER OF SECTION 15, TOWNSHIP 6 SOUTH, RANGE 66 WEST OF THE 6th P.M. 18901 LONGS WAY, PARKER, CO 80134 GRAPHIC SCALE 30 0 15 30 1 INCH = 30 FEET PHOTOMETRIC PLAN MINI U STORAGE JOB NO. C4075 APRIL 28, 2015 SHEET 6 OF 13 ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING PLANNING 5600 S. Quebec Street, Suite 310B, Greenwood Village, Colorado 80111 TEL: 720.536.3180 www.dimensiongrp.com