Visqueen Vapour Control Tapes

Similar documents
Carbon Film Installation Instructions

CoziMat. 1. Introduction and Brief Description COZIMAT INSTALLATION INSTRUCTIONS & SAFETY REQUIREMENTS

Urban Drainage Geomembrane (UDG)

Stormwater protection

SPIDER P SPIDER P mineral

Knauf Direct Bonding and Metal Furring

GENIE CLIP TYPE RST. Resilient Sound Isolation Clip INSTALLATION INSTRUCTIONS

Banda Cay Wallpaper. eskayel.com T South 6th Street Brooklyn, NY 11249

Royden. Look how easy it is to roll out the heat

Smoke extraction duct of sheet steel

Kalos Cameo Wallpaper

Installation Manual Loose cable underfloor heating. A large print version can be downloaded from our website. www. underfloorheatinghq.co.

FIRE TUBE Fire protection for process pipes and structural steel

Madagascar Sky Blue Wallpaper

Always check local building codes before doing any construction work.

2. References EN 13829:2001. Thermal performance of buildings. Determination of air permeability of buildings. Fan pressurization method.

RG1,5SA Self Adhesive

Firestone Lining Systems. Dependable Performance in Demanding Environments

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

Porta Mural Wallpaper

Twin Wall Installation Instructions And Maintenance Guide

Vacuum Bonding of Safety and Architectural Glass Laminates

IdealFILM. Do-It-Yourself Installation Manual

SPECIAL SPECIFICATION 3687 Impermeable Liner

BDM Direct Vent systems are for use with direct vent gas fired appliances.


FLAGON PVC FLAGON SV ROOFING SYNTHETIC MEMBRANES

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

Leadax B.V. Covenant K93792/02. Leadax

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide

ENRGY CURB APPLICATION GUIDE FOR TPO ROOFING SYSTEMS

HOTFOIL HB MODULE HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL HB.IOM.R3

Regupol SonusClip Installation Guide for Walls or Ceilings with Wood or Steel Framing

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

Installation Instructions. DucoStone and DucoLite Shower Trays 226MEZ 0117CH

ELEKTRA HEATING MATS. Designed to be installed under laminate flooring and/or engineered wood UK PL RU. Installation manual

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

Installing Underfloor Heating Film. 1. Layout of electric underfloor heating systems

See product BS EN :2010

Pond Liners & Water Containment

INTERNAL FRAMING PROFILES

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

45 Wide Format Hot and Cold Laminator

Icopal Screw Fasteners & Accessories

NOVITHERM TM Heat Reflectors Installation Guide

6. Detail drawings. 1. Lap Splices 2. Corners 3. Penetrations 4. Terminations 5. Anchoring 6. Membrane cover

Electric Warm-Stretch under floor heating

Firestone GeoGard EPDM Review of Technical Performances

Firestone EPDM Geomembrane Review of technical performances

Certified according to ISO 9001:2008 and ISO 14001:2004

Foil Heaters. Installation Manual: TECHNICAL HELPLINE

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

# OF GROOVES PER FOOT OF PANEL AVAILABLE EDGE TREATMENTS T&G BANDED # OF GROOVES AVAILABLE EDGE TREATMENTS PER FOOT OF PANEL T&G BANDED

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

ALUMINUM. ELEVATED. CEDAR RENDITIONS DESIGN SERIES INSTALLATION INSTRUCTIONS

KUTERLEX & KUTERLEX PLUS PLASTIC COATED COPPER TUBE

Liner Construction & Testing Guidance Overview

CORNICE FOR INDIRECT LIGHTING

OPERATION GARAGE Butler

FIREPRO SoftSeal System

GEOMEMBRANE FIELD INSTALLATION

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

Underfloor Heating Cable Installation Manual

Geotextile Separation Interlayer Guide Specification

Concealed Ceiling Systems

6ft Wide Polytunnel Assembly Instructions

ARCHITECT S SPECIFICATIONS For Commercial Vinyl Wallcoverings

SHORT WAVE INFRARED PANEL DRYER

SYSTEM DATA SHEET Sikafloor MultiDur ES-44 ESD

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

CONCEALED CEILING SYSTEMS INSTALLATION GUIDE

C08. S05. P02 P05 Decorative effects

Always make sure to check the heating film before, during, and after installation of the floor covering.

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

NARRATIVE REPORT. Underlayment Paper for Linoleum. The Asbestos Bulk Sample Results Table includes asbestos sampling data.

DESIGN & INSTALLATION GUIDE

Installation & Maintenance Instructions

Rotary XL (558 Series) and Classic (548 Series)

DESIGN & INSTALLATION GUIDE

Condensation On Windows

Model Dimensions Coverage 230v 230Vac. Pack Contents. Measuring Up

ARCHITECT S SPECIFICATIONS

SECTION (15820) - AIR DUCT ACCESSORIES

10ft Wide Polytunnel Assembly Instructions

Mu-copper Faraday cages

EFFISUS BRAZE MEMBRANE

HEATING USER GUIDE. Philex Support Line: Monday to Friday 9.00am to 5.00pm (Local rate - UK only)

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

SonusClip Installation for walls or ceilings on wood or steel framing. Installation Instructions for Wall & Ceilings

Butyl Products Ltd. Pond Guide

Rhyno. Woven Polypropylene Geotextiles. Geosynthetics Limited

2012 INTERNATIONAL FUEL GAS CODE VENTS

Low Gradient Velocity Control Short Term Steep Gradient [1] Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

Geomembranes that work

Transcription:

Technical Product Datasheet Edition: 12/01/2018 Identification no. VBP014 Visqueen Vapour Control Tapes Supports the installation of Visqueen Vapour Check membrane Utilises Visqueen s advanced adhesive technology Outstanding working temperature range -40oC to 40oC Exceptional adhesion to wood and metal Displaces moisture ensuring good bond to surface 20 X more aggressive than standard adhesive systems at low temperatures The complete system: Ensures airtightness and compliance to Part L Building Regulations Protects insulation from condensation damage. Conforms to VCL CE Mark EN13984:2013 Description Visqueen New high performance range of vapour control tapes, when installed correctly with Visqueen Check membrane (also known as Vapour Control Layers, VCLs), restricts vapour permeation and increases the thermal efficiency of buildings. Visqueen s Vapour Control system is part of a Build tight- Ventilate right strategy and protects insulation from condensation damage. The high performance system consists of: Visqueen Double Sided Vapour Tape - 20mm x 50m for mounting vapour barriers on metal or timber substructures Visqueen Single Sided Vapour Tape - 50mm x 15m for jointing vapour barriers. Also detailing round penetrations VCL membranes The tape range should be used with the following Visqueen Vapour Control Layers: Visqueen Vapour Check 125 micron thick, 4m x 50m or 2.45m x 50m

Applications Visqueen Vapour Control tape range supports the installation of Visqueen Vapour barriers in the following applications: On the inside of buildings for walls, floors, ceilings and roof structures Timber and metal frames Solid concrete floor and wall structures Did you know Visqueen Vapour Control system ensures airtightness without damaging the membranes using nails or staples. This also contributes to greater thermal efficiencies. Damp Proof Membranes (DPM) or Temporary Protective Sheeting (TPS) are NOT suitable as vapour control layers as VCLs must be tested and comply with the requirements CE Mark EN 13984:2013 Specific Approvals / Standards CE Mark to EN13984:2013 Plastic Vapour Control Layers Part L Building Regulations BS5250:2011 Code of practice for control of condensation in buildings The Innovative Visqueen Advanced Adhesive Technology A high performance adhesive Exceptional adhesion to various surfaces Extreme application temperature range (-40oC to 40oC) Displaces moisture ensuring good bond to surface Suitable for indoor and outdoor use Installation Mounting vapour control layer on prewall structures: Apply Visqueen Double Sided Vapour Tape to the timber (or metal) studs, head and sole plate. Once applied use a hard rubber seam roller over the tape to ensure a good bond. Carefully peel off release liner. Apply the Visqueen Vapour Control Layer membrane to the frame and use a hard rubber seam roller to press on each strut to ensure a good bond. For jointing, overlap the VCL membrane by approx. 100mm and seal overlap with Visqueen Single Sided Vapour Tape.

Perimeter flashing jointing the VCL to the solid wall Before applying, please ensure all surfaces are clean and dust free. For protecting and sealing the perimeter, a twin tape system is required. Ensure vapour barrier continuity by applying Visqueen Double Sided tape 50 mm from the edge of wall, overlap the Visqueen Vapour Check membrane and press firmly down onto the tape using a hard rubber seam roller. To complete the seal, use Visqueen Single Sided Vapour Tape applied equidistant over the junction. Penetrations Apply Visqueen Single Sided Vapour Tape half to the pipe and half to vapour control layer. Apply the tape in small length cuts as shown in diagram below.

Storage and Handling VisqueenPro Vapour Tapes are classified as nonhazardous when used in accordance with the relevant British Standards. The product should be o stored in a warm, dry environment - above 5 C. Availability Visqueen Vapour Control range tapes are available throughout the UK at Visqueen stockist centres. Find you nearest centre by clicking here Please note Visqueen Double Sided Vapour Tape is sold in boxes containing 5 rolls. All other tapes are sold singularly.

Product & Performance Data: Description Visqueen Single Sided Vapour Tape Visqueen Double Sided Vapour Tape Value 50mmx15m 20mmx50m* * sold 5 per box Application temperature range -40oC to 40oC Peel adhesion testing N/25mm Steel 53.6 PE 50.4 Wood 51.2 N/318mm2 Shear test 15.5 Visqueen Building Products Heanor Gate Heanor Derbyshire DE75 7RG Phone: 0123456789 Fax: 0123456789 Email: Enquires@visqueen.com For our full range of products, visit www.visqueen.com