Radiation Environment on ISS in April 2013 According the Data from Liulin-5 Particle Telescope

Similar documents
Example Solar Proton Event Data

Status Report of Active Space Radiation Detector, A-DREAMS-2 at NIRS

RADIATION PROTECTION PROPERTIES OF ADDITIONAL SHIELDING «PROTECTIVE CURTAIN» INSTALLED IN CREW CABIN OF RUSSIAN SEGMENT OF ISS

Heavy Ion Beam Characteristics of ICCHIBAN 7 and 8 Experiments and Brief Summary of the ICCHIBAN Experiments

Update on the NASA Plans for Dosimetry in Support of Manned Spaceflight

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

Radiation Safety for AREAL Phase 1

Global fire hotspots detected by NASA satellite to help United Nations

Monitoring of Radiation Exposure Adjacent to a Linear Accelerator Treatment Bunker with a Highlight Window

Long-term Inventory of Fire Burned Areas and Emissions of North America s Boreal and Temperate Forests

PERFORMANCE MONITORING OF A HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMP WITH INJECTION CYCLE INSTALLED IN A LOW-INSULATED SINGLE-FAMILY HOUSE IN BELGIUM

NASA Plans for Dosimetry in Support of Manned Spaceflight

Radon and Thoron Measurements at Special Underground Circumstances

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

Wildland fire phenomenology experiments:

ENERGY CONSUMPTION OF HOUSES AND LIFESTYLE IN COLD CLIMATIC AREA OF JAPAN

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

Seismic Countermeasures for Environmental Radiation Monitoring System

Electronic Personal Dosemeter

Review of options for cabin dosimetry & operation. Helen Amatiello & Colin Martin Health Physics Service Glasgow

A study of Indoor Radon / Thoron Levels in Some Dwellings by using Solid State Nuclear Track Detectors

SEASONAL CROP COEFFICIENT OF GERBERA SOILLESS CULTURE

Optical Properties of Blocking Glass in the WFC3 IR Channel

WG Container & Cargo X-Ray Scanning Portal

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current

The system can be easily relocated by a standard container truck., and re-commissioned by trained engineers typically within a 72-hour period

Urethral alarm probe for permanent prostate implants

WG Entire Truck & Cargo X-Ray Scanning Portal

CART and GSFC Raman Lidar Measurements of Atmospheric Aerosol Backscattering and Extinction Profiles for EOS Validation and ARM Radiation Studies

Dual-Diode Dosimeter Patient Dose Monitor

Scientific Production Company Doza. Radiation monitoring equipment

Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement

SYNCHROTRON RADIATION ABSORPTION AND VACUUM ISSUES IN THE IR*

Instrument Standards Used in Security Applications Presented by: Leticia Pibida, Ph.D.

Kata products Kata DGM-1500 Turva

Development of high sensitivity radon detectors

Ionisation Energies. You can write equations for this process: Na (g) Na + (g) + e kjmol -1. O(g) O + (g) + e kjmol -1

Beam Loss Position Monitoring with Optical Fibres at DELTA

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

INEEL (1500) [45] 5.6 C 217 mm 60. Precipitation (mm) Temperature (oc) Month

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

Portable Survey Instruments NISP-RP-01

Performance Requirements for Monitoring Pulsed, Mixed Radiation Fields Around High-Energy Accelerators

The effect of write current on thermal flying height control sliders with dual heater/insulator elements

Ultraviolet radiation detector to obtain the rate of particles at different heights

Ionisation Chambers Containing Boron as Neutron Detectors in Mixed Radiation Fields

E11 Tests of trace gas concentration multicomponent. monitoring system

Using the GammaRAE II Personal Radiation Detector

ISSN: [Agcaoili S. O., 7(3): March, 2018] Impact Factor: 5.164

Radiation Control and Monitoring System on the HTTR

Radiation Safety issues for the PF-AR in KEK

The Role of Satellite Observations in Assessing Impacts of Wildfire Occurrence on Respiratory Health of Population

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

Smoke Detection in Low Gravity Results from the Smoke Aerosol Measurement Experiments (SAME) Conducted on the International Space Station

EVALUATION OF A NEUTRON-PHOTON SHIELD FOR TRANSURANIC (TRU) WASTE CONTAINERS

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

DMC 3000 User s Guide

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

RAD-60 USER GUIDE (ALSO FOR THE RAD-50 MODEL AND ISOTRAK DOSIMETERS)

Effect of Different Types of Fabricated Anti-scatter Grids in Reducing Backscattered Radiation

Use of new spatially refined satellite remote sensing fire detection data in support of advanced wildfire mapping and modeling

MicroMED: the Dust Particle Analyser of the ExoMars 2020 Dust Suite

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

Effects of Planting Dates and Varieties on Growth and Yield of Broccoli During Rainy Season

Identification of Aberrant Railroad Wayside WILD and THD Detectors: Using Industry-wide Railroad Data. June 10, 2014

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

Maintenance and Operation for ECAL Monitoring (WBS4.3)

Highlights from a recent test campaign in Finland with scalable neutron detectors

THE ROLE OF GREEN ROOFS IN URBAN DRAINAGE A REVIEW OF THE CASE FROM AUGUSTENBORG ECO-CITY

SuperCDMS SNOLAB: Road to 100 mm Germanium Detectors

The development of a plastic scintillator for radiotherapy dosimetry

Radiation Monitoring System RMS

Improved HPLC Separations at Elevated Temperatures Using a New Stand-alone Preheater

Land SAF LSA-SAF Evapotranspiration (ET) Product

Falling Film Heat Exchangers for Solar Water Heaters

Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector

North American Technical Services

TESTS OF ADSIL COATING

Better Buildings By Design 2013 Building the Renewable Energy Ready Home Solar Thermal Lessons Learned and Results

Freiburger Materialforschungszentrum SG Material Characterization & Detector Technology. Albert-Ludwigs-Universität Freiburg

Brine Generation Study

Asparagus Response to Water and Nitrogen

CHART PERUVIAN TECHNICAL STANDARDS

The Problems Related to Orphan Radioactive Sources in Scrap Metal (Georgian Experience)

Carnegie Mellon University Radiation Safety Committee

The distributed particle detectors and data acquisition modules for Extensive Air Shower measurements at "HT-KZ" experiment

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Diamond as potential CryoBLM for the LHC All results are preliminary

Theoretical model of circular solar collector for close water open air (CWOA) heated humidification and dehumidification

Detection of Ionizing Radiation using Solar Blind Air Fluorescence

MD456: Monitoring of abort gap population with diamond particle detectors at the BGI in IP 4

A CONCEPT FOR CANCELLING THE LEAKAGE FIELD INSIDE THE STORED BEAM CHAMBER OF A SEPTUM MAGNET*

Integrating Nephelometer - Visibility and Particulate Monitoring. Summary

Advanced Radiation Detection Equipment

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

SEVIRI/MSG sensor early fire detection performances assessment

FLACS-Fire. Djurre Siccama Gexcon R&D and Software VP Products. FLUG 3 rd - 4 th. November 2015, Shanghai China

Transcription:

Radiation Environment on ISS in 2012- April 2013 According the Data from Liulin-5 Particle Telescope J.V. Semkova a,t.p. Dachev a, R.T. Koleva a, St. Malchev a, N. G. Bankov a, V. Benghin b, V. Shurshakov b, V. Petrov b, S. Drobyshev b a Space Research and Technology Institute, Bulgarian Academy of Sciences, Sofia, Bulgaria b State Research Center Institute of Biomedical problems, Russian Academy of Science, Moscow, Russia

Introduction Experiment Liulin-5 for investigation of the radiation environment within the spherical tissue-equivalent phantom on ISS is conducted on RS of ISS. It is a part of the MATROSHKA-R project. Data available for July 2007-April 2010 and for end 2011-April 2013. Liulin-5 measures simultaneously at 3 different depths of the radial channel of the spherical phantom: Energy Deposition Spectra, Dose Rate & Particle flux - then Absorbed Dose D. Measurement of the Linear Energy Transfer (LET) spectra in silicon then assessment of LET(H 2 O), Q=f(LET), given in ICRP-60 and Dose Equivalent H; H=DxQave. We present results for dose rates and particle fluxes in and outside the phantom from end 2011 to April 2013 during increasing of SA in 24 cycle; Compared are Liulin-5 data during SPEs in 2012 and data from Liulin dosimeter-radiometer on Mir Space station during SPEs in 1989-1991. Budapest, September 2013 2

Location of Liulin -5 instrument in the Spherical Phantom on ISS in MIM1 module D3 D2 D1 Electronics of Liulin - 5 28V Passive detectors Stand Detector module of Liulin-5 Block diagram of Liulin - 5 in the phantom From 27 December 2011 to April 2013 measurements were conducted in and outside the phantom located in the MIM1 module of ISS. Budapest, September 2013 3

Liulin-5 results for the period April 2012-April 2013 Budapest, September 2013 4

Mapping the dose rate along the ISS orbit Protons >100 MeV; AP-8 MAX model at 400 km SPENVIS http://www.spenvis.oma.be/ Dose rate (40 mm depth) 27.12.2011-17.04.2012. The SAA dose rate reached maximum of 524 µgy/h on 27.01.2012 at -22.3 0 lat, -54.25 0 long. and 401 km alt. at L =1.2 and B=0.194 Gs. Outside SAA lowest doses of ~1 µgy/h near the equator, highest of ~9.5 µgy/h at high latitudes. Budapest, September 2013 5

Dose rate at 160 mm depth in the phantom and outside phantom from April 2012 to April 2013 240 outside phantom D3 [ugy/day] 200 160 in phantom 120 1-Apr-12 1-Aug-12 1-Jan-13 1-May-13 Date Total dose rate. Doses outside phantom are 1.7 higher than at the phantom s center due to self shielding of the phantom against SAA trapped protons. Budapest, September 2013 6

Dose rate (µgy day -1 ) D3 [ugy/day] GCR dose rate from April 2012 to April 2013 88 84 80 76 72 GCR dose rate 68 1-Apr-12 1-Aug-12 1-Dec-12 1-May-13 Date http://cosmicrays.oulu.fi/ GCR dose rate minimum is in July-August 2012 consistent with Oulu NM count rate below. Budapest, September 2013 7

SPEs results Historical LIULIN on Mir results Budapest, September 2013 8

Solar Particle Event observation on Mir space station on 29.09.1989 by LIULIN instrument* Before SPE After SPE Flux Max = 250 cm 2 s -1 Dose rate max = 3000 µgy h -1 *Dachev et al., MIR dosimetry, ASR, 321-324, 1991. Budapest, September 2013 9

The proton energy decrease during the SPE Liulin flux (cm -2 s -1 ) 47 MeV 21 MeV GOES-7, SEM flux (cm -2 s -1 sr -1 ) Budapest, September 2013 10

6 different SPE observations by LIULIN on Mir Liulin flux (cm -2 s -1 ) Liulin dose rate (µgy h -1 ) Budapest, September 2013 11

Liulin-5 results for SPEs in March and May 2013 Budapest, September 2013 12

On 07.03.2012 GOES -13 registered beginning of two SPE associated with Earth-directed CMEs. More than 100 MeV event began at 04:05 Zheng, Y., NASA GSFC Space Weather Center operational Experiences over the past several major solar Events, ESWW9-Session4A, November 2012. http://www.spaceweather.eu/en/repository/show?id=379 Budapest, September 2013 13

GOES-13 satellite X-ray flux X5.4 flare! GOES-13 satellite environment plot Budapest, September 2013 14

Dose rate distribution during March 2012 SPE (outside SAA) (1) Dose rate [ugy/hour] 120 80 40 D1 D3 Data for 07.03.2012, 12:59 UT- 08.03.2012, 21:31 UT Successive measurements at 40 mm depth (red) and at 165 mm depth (green) outside SAA during SPE. The first registration of particle flux and dose rate increase in Liulin-5 data was on 07.03.2012, at 13:01 UT. The last registration of flux and dose rate increase was on 08.03.2012, at 21:31 UT. 0 0 400 800 1200 1600 Measurement N Budapest, September 2013 15

Dose rate in the first detector (D1) outside SAA during SPE in March 2012 Data from 07.03.2012, 12:59 UT to 08.03.2012, 21:31 UT. Increase of dose rate from solar protons is observed at high geographic latitudes in the region of the south and north magnetic poles at L>3. Budapest, September 2013 16

Particle flux and dose rate during quite conditions and SPE in March 2012. The total dose outside SAA received during SPE was 260 µgy. Particle flux F1 and dose rate D1 at 40 mm phantom s depth before (left) and during SPE (right), March 7-12 2012. The maximum flux observed outside SAA during SPE reached 7.2 cm -2 s -1 and the dose rate reached 108 µgy h -1 at L = 4, Lat = - 51.1 0, Long =166.8 0, Alt= 422 km. The averaged dose rate D1 outside SAA during SPE was 8.43 µgy h -1 and averaged flux was 0.59 cm -2 s -1 Budapest, September 2013 17

Particle flux and dose rate during SPE in May 2012 14-21 May 2012 SPE Budapest, September 2013 18

Comparison of the GOES-13 flux data with Liulin-5 dose rate during the March 2012 SPE GOES-13 flux data of protons with energies >100 MeV (blue), Liulin-5 dose rate measured outside SAA (red) and the corresponding L values (black) versus time during SPE. Budapest, September 2013 19

Comparison of the GOES-13 flux data with Liulin-5 dose rate during the May 2012 SPE SPE L Value GOES-13 flux data of protons with energies >100 MeV (blue), Liulin-5 dose rate measured outside SAA (red) and the corresponding L values (black) versus time during SPE. Budapest, September 2013 20

Comparison of the L value profiles of the SPEs in 1989-1991 and 2012 7 March 2012 17:20:08-17:46:30 30 September 1991 00:54:10-01:18:40 Budapest, September 2013 21

LET spectra and Qav Deposited energy and LET spectra on orbits not crossing SAA. Upper curve in both spectra- during SPE Q=2.5, DR= 10.09 µgy h -1, lower curve after SPE -Q=4.147, DR= 2.81 µgy h -1. Deposited energy [MeV] LET [kev/µm] Budapest, September 2013 22

CONCLUSIONS In MIM1 module the doses outside phantom (210-230 µgy/day) are 1.7 higher than at the phantom s centre; The GCR dose rate decreased from ~ 85 µgy/day in April 2012 to ~ 70 µgy/day in September-October 2012. From September October 2012 the GCR dose rate increases. The behavior is consistent with Sunspot Number R i ; During SPEs of 7-12 March 2012 at 3 < L the particle flux and dose rates increased in all three depths of 40, 60 and 165 mm along the radius of the tissue-equivalent spherical phantom in MIM1 module of ISS. The additional absorbed dose at 40 mm depth in the phantom from SPEs is ~ 180 µgy, the additional dose equivalent is ~ 450 µsv - comparable to the averaged daily absorbed dose and dose equivalent in the spherical phantom in ISS during quite periods. Outside SAA during SPE Q is 2.5, dose equivalent rate at 40 mm depth is 21.1 µsv/h. After the SPE Q is 4.15, dose equivalent is 11 µsv/h. No significant increase of dose rate and particle flux during SPE in May 2012; Good agreement of Liulin-5 dose rates trend during the SPEs with the proton flux 100 MeV measured by GOES 13; Dose rates and particle fluxes observed at 3 < L during SPE on Mir station in 1989-1991 are higher than those in 2012 on ISS. Budapest, September 2013 23

Acknowledgements Agreement between RAS and BAS on space research and grant DID-02/8 from the Bulgarian Science Fund; NIRS Japan; RKK Energia and the cosmonauts for the operation of Liulin-5 instrument aboard ISS. Budapest, September 2013 24

Thank you for your attention 25 Budapest, September 2013