2006G2 OPERATING INSTRUCTIONS. 2006G2 Pressure-Vacuum Hand Pump July 2011 SOILMOISTURE

Similar documents
OPERATING INSTRUCTIONS

1909/1910 QUICK START GUIDE. Simpler Soil Water Samplers 02/2018. Fig. 1 - Model 1910LL Fig. 2 - Model 1910PL Fig. 3 - Model 1909L

SuperKlean Washdown Products

569, 570, 571, 572 Series

569, 570, 571, 572 Series

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Installation Instructions

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.


AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

INSTALLATION, OPERATION AND SERVICE MANUAL AERATION SYSTEMS FEATURING AIR COMPRESSOR AND AIR ELIMINATOR TANK

568X, 587X, 588X Series

INSTALLATION INSTRUCTIONS

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

HE220, HE260 Humidifier Installation Kit

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111

Owner s Guide and Installation Manual

INSTALLATION INSTRUCTIONS

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

INSTALLATION GUIDE HIGH PRESSURE CLEANER (1800C) If there is any question during using, please feel free to contact us by

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

Owner s Guide and Installation Manual

HX Field Replacement Kit

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS

The Flush Kit: The perfect companion to Harvest Right home freeze dryers. The Flush Kit. User s Manual

Parts & Material Included

1350 & AMMCO Brake Washer Systems. Installation and Operating Instructions With Safety and Maintenance Instructions and Parts Identification

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

HHP-300 EXTRACTOR 120V

English Manual for Jewelry Casting and Investing The professional choice

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

MC-V Vacuum Cleaner. Specifications are subject to change without notice for further improvement.

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Installation Instructions

QUICK PRIME INSTALLATION AND SERVICE MANUAL

Blue Ribbon Corporation

SECTION METERS AND GAGES FOR HVAC PIPING

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

Installation and Care Instructions

OWNER S MANUAL MODULAR DIRECT CONNECTED TILTING STEAM JACKETED KETTLE

GETZ MANUFACTURING PART NO.: MODEL: SV1 100 PR VACUFILL SYSTEM (Revised 6/7/05)

HE360 Humidifier Installation Kit

Fleck 2510 Sediment Filter Installation & Start-Up Guide

Audi-Larm Audible Alarm

TK-1001, 1101, 1201, 1301, 1601

Heat Exchanger Block Replacement Instructions

MEGATRON MODEL 2, 3, 4, and 5

5700-E Sediment Filter Installation & Start-Up Guide

MKV MILK METER ICAR approved TECHNICAL MANUAL. Part Number: Waikato Milking Systems NZ Ltd, 2006

INSTALLATION INSTRUCTIONS

50T Electric Shop Press

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Model HC-2. Crathco Whipped Hot Chocolate Dispenser. Table of Contents. Operation and Instruction Manual. for

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

Owner s Guide and Installation Manual

METRO BASIN MONO MIXER CHR

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

VERTICAL GLANDLESS PUMP

100T Electric Shop Press

SECTION METERS AND GAGES FOR PLUMBING PIPING

Installation and Care Instructions

OPERATION MANUAL VCX-4 Vacuum Coolant Exchanger

DESCRIPTION MAINTENANCE INSTALLATION OF NEW SEAL REMOVAL OF OLD SHAFT SEAL

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

SD Bendix AD-1 and AD-2 Air Dryers

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

BMW E36 Thermostat Removal And Coolant Flush

Pool Weasel Vacuum Users Guide

Owner s Guide and Installation Manual

Installation and operating instructions. E.2 Series high efficiency circulator

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

Model H1011.8/H1011.8HPS Water Cooler

150T Electric Shop Press

Chemical resistant Vacuum Pumps

GETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14)

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM

HDLV 55-Gallon Powder Drum Unloader

QUICK PRIME INSTALLATION AND SERVICE MANUAL

INSTALLATION INSTRUCTIONS

Traditional Rigid Riser With Eight Inch Rose

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

INSTALLATION INSTRUCTIONS

T-Series Air Conditioner T15 Model

CAUTION EXPOSED SHARP OBJECTS INSIDE. HAZARDOUS MOVING PARTS DO NOT OPERATE WITH COVER OPEN. for Block Ice

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days

Operating instructions for Grumbach Incubators

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Stainless Steel Pump to dispense portions up to 2oz MODELS INCLUDE:

Owners Manual. SM-HP A SM-HP8-10 Meter. Manual D

CONSTANT SUCTION UNIT

Condensate Pump. Installation and Safety Instructions CP-NL20 CP-NL20-230

Mitocell: Instructions for Use

Transcription:

OPERATING INSTRUCTIONS 2006G2 Pressure-Vacuum Hand Pump July 2011 2006G2 1

TABLE OF CONTENTS UNPACKING...1 ACQUAINT YOURSELF WITH THE PARTS...1 REMOVAL OF AIR FROM TENSIOMETERS...2 PULLING A VACUUM IN THE SOIL WATER SAMPLER...3 AND REMOVING A COLLECTED WATER SAMPLE...4 AS A VACUUM SOURCE FOR PORTABLE EXTRACTORS...5 TO CHECK THE CALIBRATION OF TENSIOMETER DIAL GAUGES...6 GENERAL CARE AND MAINTENANCE...7 MINOR ADJUSTMENTS...8 REPLACEMENT PARTS...8

The 2006G2 Pressure Vacuum Hand Pumps provide versatile, simple tools for many servicing and calibrating operations on our various tensiometers. They supply a source of vacuum for our soil water samplers and portable extractors. UNPACKING The 2006G2 Pressure -Vacuum Hand Pump shipped to you is completely assembled and has been thoroughly tested before shipment. When packed, it was in perfect working order. Unpack with care being sure to remove all packing material. Follow the instructions carefully in order to assure long trouble-free service. NOTICE: ANY DAMAGE FOUND UPON RECEIPT, SHOULD BE REPORTED IMMEDIATELY TO THE TRANSPORT CARRIER FOR CLAIM. IT IS IMPORTANT THAT YOU SAVE SHIPPING CONTAINER AND ALL EVIDENCE TO SUPPOR T YOUR CLAIM. Be sure to read all operating instructions thoroughly before operating the unit. ACQUAINT YOURSELF WITH THE PARTS The 2006G2 Pressure-Vacuum Hand Pump is used for calibrating other vacuum dial gauges as used on our tensiometers, and for pulling a vacuum in our soil water samplers, portable extractors, and other units. The vacuum dial gauge is a Bourdon Tube-type gauge and measures the vacuum in the unit. It is graduated 0-100 centibars (or 1 Bar) of soil suction. The vacuum dial gauge was hermetically sealed at the factory, at sea level. If you live at a high elevation, the pointer on the dial gauge may be reading higher than zero. This is due to the lower atmospheric pressure at your elevation. Before putting the unit to use, vent the dial gauge by momentarily removing the vent screw in the clear plastic gauge cover, see Fig. 1. Use a small screwdriver for this purpose. After venting, return the vent screw to the gauge cover. The Handle is made from laminated hardwood and is 10 long by 1 diameter. The Top Cap is made from grey PVC and incorporates an air vent hole to vent the air from the tube while pulling a vacuum. The Tube is made from a low leaded brass tube and is chrome plated for corrosion resistance. The Leather Cup Washers and Steel Washers combine to make a vacuum and pressure seal on the inside walls of the tube during the pumping action. The Valve Body is made from grey PVC which has machined cavities to hold the polypropylene check valves and the vacuum and pressure fittings. The Vacuum Fittings and Pressure Fittings are 1/4" NPT by 1/4" tube brass fittings which are chrome plated for corrosion resistance. The Base is made from laminated hardwood, the same type as used on the Figure 2 handle and measures 3" wide by 12" long by 3/4" thick, and is held to the valve body by way of two 1/4-20 by 1-1/4 long stainless steel hex head cap screws. Both units measure approximately 22" in height and will store easily in most any space. 3

REQUIREMENTS PRIOR TO USE An Inline Air Filter is supplied with the Pressure Vacuum Hand Pump to filter out any debris that might get into air lines while using the pump. Place the filter in the air line between the pump and the unit with the arrow on the filter pointing in the direction of flow. REMOVAL OF AIR FROM TENSIOMETERS USING PRESSURE/VACUUM HAND PUMP The adapter fitting should be assembled into the 3/16" I.D. rubber hose and the hose pushed on the vacuum fitting of the hand pump. Hold the adapter fitting firmly against the 0 ring seal in the filter end of the tensiometer body to create a seal, as shown in Fig. 2. As the pump handle is pulled up, the vacuum created within the tensiometer will cause the air to bubble from the vacuum dial gauge stem and up to the surface of the water. After each pumping, to release the vacuum, tilt the adapter fitting slightly to slowly break the seal between the adapter fitting and 0 ring seal, as shown in Fig. 3 Fig. 4 shows how a vacuum is pulled in a dial type tensiometer to remove air bubbles from the unit before it is installed in the soil. This will enable the gauge needle to return to zero slowly without damage to the gauge. Additional water is added to the tensiometer after each pumping. The pumping operation should be repeated four to five times to 2 gradually remove all of the air.

PULLING A VACUUM IN THE SOIL WATER SAMPLER AND REMOVING A COLLECTED WATER SAMPLE USING THE 2006G2 PRES- SURE-VACUUM HAND PUMP For the 1900 Soil Water Sampler, insert the vacuum fitting into the rubber tube of the stopper assembly, Fig. 6. The pinch clamp on the stopper assembly is opened and the pump is then stroked until a vacuum of perhaps 60 centibars (18" of mercury) or more, is created within the sampler as read on the vacuum dial gauge. When a sufficient vacuum is reached, the pinch clamp is closed to retain the vacuum within the sampler. The pump can then be removed for other uses. To remove the collected soil water sample from the 1900 Soil Water Sampler, a simple assembly is used made of a small xxx diameter plastic tube (3/32" O.D. or less), a two-hole rubber stopper, and a flask or bottle, as shown in Fig. 7. The pinch clamp on the the bottom of the sampler. The other end of the plastic tube is pushed into one of the holes in the two-hole rubber stopper. The vacuum fitting of the pump is connected to the other hole in the stopper, Fig. 8, and then pumped to create a vacuum within the flask or bottle. The vacuum will pull the sample up from sampler, through the plastic tube and into the flask or bottle. sampler is opened, and the small diameter plastic tube is inserted into the end of rubber tube on the stopper assembly and pushed down until it reaches 5

On the Model No. 1920 Pressure-Vacuum Soil Water Sampler, the pinch clamp on the discharge access tube is closed and the vacuum fitting of the Pressure-Vacuum Hand Pump is connected to the pressure-vacuum access tube, Fig. 9. The pump is then stroked until a vacuum of about 60 centibars (18 of mercury) is created within the sampler, as read on the vacuum dial gauge connected to the pump. The pinch clamp on the pressure vacuum access tube is then closed securely to seal the sampler under vacuum. The hand pump can now be disconnected for other uses. To remove the collected soil water sample from the Model No. 1920 Pressure Vacuum Soil Water Sampler, attach the pressure-vacuum access tube to the pressure fitting of the Pressure-Vacuum Hand Pump, Fig. 10. Place the discharge access tube in a small collection bottle and open both pinch clamps. Apply a few strokes on the hand pump to develop enough pressure within the sampler to force the collected sample out of the sampler and into the collection bottle. USING THE 2006G2 PRESSUREVACUUM HAND PUMP AS A VACUUM SOURCE FOR PORTABLE EXTRACTORS Connect a length of 3/16 I.D. rubber hose to the connection fitting of the portable extractor and the vacuum fitting of the pump, Fig. 11. A pinch clamp is placed on the rubber tube and left open. A vacuum of 80 to 90 centibars is then pulled, using the pump, within the extractor as read on the vacuum dial gauge. After the vacuum is pulled, the pinch clamp is closed, and the pump can be removed for other uses. The vacuum created within the extractor will cause the soil water sample to move from the funnel into the collection bottle. USING THE PRESSURE/VACUUM HAND PUMP TO CHECK THE CALIBRATION OF TENSIOMETER DIAL GAUGES The adapter fitting on the end of the rubber hose is inserted into the filler end of the tensiometer body and held tightly against the 0 ring seal to make a vacuum-tight seal, as explained previously. As a vacuum is pulled within the tensiometer, the reading of the vacuum dial gauge on the tensiometer can be compared with the reading of the vacuum dial gauge on the pump, which is used as the reference gauge. In checking the calibration of the vacuum dial gauge, it is always desirable to lightly tap the gauge case to relieve the internal friction of the gauge mechanism to obtain the most accurate reading. GENERAL CARE AND MAINTENANCE When the 2006G2 Pressure-Vacuum Hand Pumps are used for air removal or pulling a vacuum, very little maintenance of the unit is required. If, however, the pump will not hold a vacuum or has a pressure leak, the check valves of the pump could be leaking due to accumulation of debris. The check valves can be removed to be flushed and cleaned of particles which may interfere with their proper sealing action. To remove the check valves, unscrew the tube from the

valve body and remove the holding plate at the bottom of the tube cavity, Fig. 12~ The check valves can then be removed from the valve body, taking care to observe the correct orientation of each check valve, as they are the same in construction. The vacuum check valve should have the arrow on the side pointing towards the handle while the pressure check valve should have the arrow pointing towards the base. Once the check valves are removed, the valves can be disassembled by inserting a knife blade into the joint, Fig. 13, created by the body and cap, and prying the two pieces apart revealing the rubber sealing disc. Flush any accumulated debris is from inside the body, and clean the sealing disc of debris. Reassemble the check valve, pressing the body and cap together, and insert the valve into the valve body as shown in Fig. 12. If the Inline Air Filter gets clogged due to the accumulation of debris, attach the air filter to the pressure inlet of the pump, in the opposite direction of flow used, and blow the debris out of the air filter with one or Cap two pumps from the Pressure- Vacuum Hand Pump. MINOR ADJUSTMENTS To Adjust the Pointer First remove the vent screw from the dial gauge and insert a small screwdriver through the hole in the gauge cover plate to engage the slot in the adjusting screw. If the gauge was reading high, tum the screwdriver clockwise an estimated amount to correct the error. If the gauge was reading low, turn the screwdriver counterclockwise an estimated amount to correct the error. Repeat the process if necessary until the pointer is on the zero position. 7

2006G2 PARTS LIST INDIVIDUAL REPLACEMENT PARTS ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION 1 MML029 Leather Plunger 12 2006G1-007 Check Valve 2 RW030SCR Washer 13 2006G1-008 Holding Plate 3 R2420CAH Hex Nut 14 2006G1-009 Plunger Support 4 RW040BNR Washer 15 2006G1-100 Handle Assemby 5 Q2420CAH20 Cap Screw, 1/4-20 X 1-1/4 16 1920K1-100 Gauge Adapter Assembly 6 7 8 2006G1-001 Base 2006G1-002 Valve Body 2006G1-004 Outlet Fitting 17 2060FG3 Vacuum Dial Gauge, 2-inch Dial, 1/4" NPT Gauge Stem, Recalibrator-style 9 M801X112 Neoprene "O" Ring 18 2006G1-003 Adapter Fitting 10 2006G1-005 Tube 19 MML043 Air Filter 11 2006G1-006 Top Cap 20 1900-203 Neoprene Tube COPYRIGHT 2011 ALL RIGHTS RESERVED 0898-2006G2 (07/11) 8