Installation GUIDE 5 SERIES. Warming Drawer VWD527 VWD530

Similar documents
Installation. Professional Built-In Electric Warming Drawers (Indoor and Outdoor Models)

Installation GUIDE 6 SERIES. Built-in Electric Single and Double Wall Ovens MVSOE630 / CMVSOE630 MVDOE630 / CMVDOE630

Viking Installation Guide

Installation. Built-In Electric Cooktop. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Installation. 3 Series Built-In Electric Cooktop RVEC330 / CRVEC330 RVEC336 / CRVEC336 RVEC345 / CRVEC345

Viking Installation Guide

Viking Installation Guide

Viking Installation Guide

INSTALLATION INSTRUCTIONS

Viking Installation Guide

Installation Guide. Built-In Electric Cooktops Built-In Induction Cooktops

GUIDE. Installation 5 SERIES. Built-In Electric Cooktops Built-In Induction Cooktops

Installation Guide. 5 Series Professional Built-In Electric Single and Double Ovens 7 Series Professional Built-in Electric Double French Door Oven

INSTALLATION INSTRUCTIONS

Viking Installation Guide

Installation. Guide. 7 SERIES Professional TurboChef Speedcook Double Oven VDOT730

Installation. Professional Built-In Electric Single and Double Ovens. Professional Built-In Electric Single and Double French Door Ovens

Installation Guide. 5 Series VGC and VGSU Built-In Gas Cooktops

DESIGN CLASS FUNCTION

Installation. Freestanding 30 Gas Self-Clean Sealed Burner Range

DESIGN CLASS FUNCTION

Viking Installation Guide

Installation. Professional Freestanding Ranges

Viking Installation Guide

Viking Installation Guide

Tuscany Freestanding Dual Fuel Ranges

GUIDE. Installation. Tuscany Freestanding Dual Fuel Ranges

Viking Installation Guide

Installation. Professional Freestanding Open Burner Ranges VGIC5301, CVGIC5301, VGIC5361, CVGIC5361

Installation. Built-in Full Height Wine Cellar VCWB301

Viking Installation Guide

Viking Installation Guide

Installation. Professional Freestanding Sealed Burner Gas Ranges VGCC530 / VGCC536 / VGCC548 / VGCC560 CVGCC530 / CVGCC536 / CVGCC546 / CVGCC560

Viking Installation Guide

SPECIFICATIONS - INDUCTION/RADIANT COOKTOP Description 30 W. VCCU 36 W. VCCU. SPECIFICATIONS - ALL INDUCTION COOKTOP Description 30 W. VICU 36 W.

Installation. 3 Series Freestanding 30 Dual Fuel Self-Clean Sealed Burner Range

DESIGN CLASS FUNCTION

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Viking Installation Guide

USE/INSTALLATION INSTRUCTIONS

Installation. Professional Freestanding Dual Fuel Ranges VDSC530 / VDSC536 / VDSC548 / VDSC560 CVDSC530 / CVDSC536 / CVDSC548

Installation Instructions Part No

Viking Installation Guide

Viking Installation Guide

Viking Installation Guide

Installation Instructions Part No

Installation Guide. 15 W. Undercounter/Freestanding Nugget Ice Machine U L. Viking Range, LLC. 111 Front Street

Viking Installation Guide

INSTALLATION INSTRUCTIONS

Installation Guide. 15 W./24 W. Undercounter Refrigeration

Viking Installation Guide

Installation. All Refrigerator / All Freezer VCRB5303 / VCRB5363 / CVCRB5303 / CVCRB5363 VCFB5303 / VCFB5363 /CVCFB5303 / CVCFB5363

Viking Installation Guide

Installation Guide. Outdoor Gas Grills. Viking Range, LLC. 111 Front Street. Greenwood, Mississippi USA (662) For product information,

Viking Installation Guide

Viking Use/Installation Guide

Installation. Outdoor Gas Grills

Installation Guide. 15 W./24 W. Undercounter Refrigeration U L. Viking Range Corporation. 111 Front Street. Greenwood, Mississippi USA

Viking Installation Guide

Installation. 15 W. / 24 W. Undercounter Refrigeration

Installation. 15 W. Undercounter/Freestanding Ice Machine FGIM515 / CFGIM515 FPIM515 / CFPIM515

Use & Care. Built-In Electric Warming Drawers. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RHPE & RTGE SERIES (ELECTRIC COUNTERTOPS) RETAIN THIS MANUAL FOR FUTURE REFERENCES.

INSTALLATION INSTRUCTIONS

Viking Use/Installation Guide

Installation. Professional Built-in Hoods

INSTALLATION INSTRUCTIONS

Viking Use/Installation Guide

Use & Care. Professional Built-In Electric Warming Drawers (Indoor and Outdoor Models)

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Professional Warming Drawer and Warming Drawer Cabinet

Viking Installation Guide

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Viking Installation Guide

INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL

Installation. Guide. Integrated Refrigerator / Freezer 7 SERIES VBI7360 / CVBI7360 FBI7360 / CFBI7360 MVBI7360 / CMVBI7360 MFBI7360 / CMFBI7360

Use/Installation Guide

INSTALLATION INSTRUCTIONS

Viking Installation Guide

INSTALLATION INSTRUCTIONS

Installation Instructions Outdoor Refrigerator

Professional Built-In Hoods

INSTALLATION & OPERATION MANUAL

Installation Instructions 36 Inch Refrigerator

TRI-STAR INC SOUTH STANDARD AVENUE, SANTA ANA, CA Ph: Fax: MODEL #. OWNER S MANUAL

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Modernist Warming Drawer

INSTALLATION & OPERATION MANUAL

OWNER S MANUAL INSTALLATION OPERATION MAINTENANCE CONVECTION OVEN MODEL # RDCO-32

Viking Use & Care Manual

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

INSTALLATION & OPERATION MANUAL

Warming Drawer Installation Guide

An Important Message for Installers and Operators IMPORTANT. Model No. Serial No.

Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

INSTALLATION INSTRUCTIONS

INSTRUCTIONS. Installation, operation and care of CLD COLD SERIE MULTIDECK COLD FOOD DISPLAY CASES IMPORTANT READ BEFORE USING DISPLAY CASE

Transcription:

Installation GUIDE 5 SERIES Warming Drawer VWD527 VWD530 1

Table of Contents Important Safety Instructions 2 Dimensions 3 Specifications 4 Cutout Dimensions 4 Electrical Requirements 5 General Information 5 Installation 6 Final Preparation 7 Service & Registration 7 Important Safety Instructions Read and Follow! Before beginning, please read these instructions completely and carefully. If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. DANGER Hazards or unsafe practices which WILL result in severe personal injury or death Hazards or unsafe practices which COULD result in death or severe personal injury CAUTION Hazards or unsafe practices which COULD result in minor personal injury. All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. DO NOT remove permanently affixed labels, warnings, or plates from product. This may void the warranty. All local and national codes and ordinances must be observed. Installation must conform with local codes, or in the absence of codes, the National Electrical Code, ANSI/NFPA-70 latest edition. The installer must leave these instructions with the consumer who should retain for local inspector s use and for future reference. In Canada: Installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes. To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards, including fire-rated conditions. ELECTRICAL SHOCK HAZARD This appliance is equipped with a 3-prong power cord with a grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. Only use power cord supplied with the unit. 2

Dimensions VWD527 22-3/4 (57.8 cm) VWD530 25-3/4 (65.4 cm) 10-1/4 (26.0 cm) VWD527 26-1/2 (67.3 cm) VWD530 29-1/2 (74.9 cm) 25-1/2 (64.7 cm) 21-1/4 (54.0 cm) 22-3/4 (57.8 cm) Side View 1-1/2 (3.8 cm) 25-1/2 (64.8 cm) 21-1/4 (54.0 cm) Rear View 2 (5.1 cm) VWD527 24-3/4 (62.9 cm) VWD530 27-3/4 (70.5 cm) 120 VAC Electrical Connection 9 (22.9 cm) 2-1/2 (6.4 cm) 1-3/4 (4.4 cm) ELECTRICAL SHOCK HAZARD This appliance is equipped with a 3-prong power cord with a grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. Only use power cord supplied with the unit. 3

Specifications Description VWD527 VWD530 Overall width 26-1/2 (67.3 cm) 29-1/2 (74.9 cm) Overall height Overall depth To end of handle With drawer fully extended 10-1/4 (26.0 cm) 25-1/2 (64.8 cm) 48-1/4 (122.6 cm) Interior width 19-1/8 (48.6 cm 22-1/8 (56.1 cm) Interior height 5-1/2 (14.0 cm) Interior depth 20-1/4 (51.4 cm) Electrical requirement 120V/15 amp power cord included with the unit Max Amp Usage 4.08 Amps Approx. shipping wt. 80 lb. (36 kg) 90 lb. (40.5 kg.) Cutout Dimensions Spacers can be placed anywhere inside the cutout as needed to make sure unit is level and does not tilt. Electrical receptacle can be located any where on back cutout. Preferred location is the rear right so that excess cord can lie in space behind control panel. B C A DIM Standard Mount VWD527 Flush Mount* VWD527 A 23-1/2 (59.7 cm) 24-7/8 (63.2 cm) B 25-1/4 (64.1 cm) 26-3/4 (67.9 cm) C 9-1/4 (23.5 cm) 10-1/2 (26.7 cm) DIM Standard Mount VWD530 Flush Mount* VWD530 A 23-1/2 (59.7 cm) 24-7/8 (63.2 cm) B 28-1/4 (71.7 cm) 29-3/4 (75.6 cm) C 9-1/4 (23.5 cm) 10-1/2 (26.7 cm) * When installing in a flush mount application, spacers may be required to ensure unit remains level and does not tilt forward when opened. Spacers can be placed on top or bottom - front or rear of cabinet. Location and size will vary based on installation and cutout. Outer cabinet edges need to be finished. 4

Electrical Requirments -Check your national and local codes regarding this unit. -Use 120V/15 amp power cord included with the unit. Electrical Connection ELECTRICAL SHOCK HAZARD This appliance is equipped with a 3-prong power cord with a grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. Do not cut or remove the grounding prong from this plug. Unit must be grounded in accordance with local codes or with the National Electrical Code ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22. General Information When installing this unit directly below other units, only install with Viking Range, LLC built-in products. Remove warming drawer carefully from carton. Remove all loose packaging and accessories. It is the responsibility of the installer to comply with local codes. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA-70 latest edition. Line disconnect switch, circuit breaker, GFI (for outdoor models) or plug/ receptacle of power cord connection should be readily accessible to the operator. Ground unit per applicable electrical codes. Any installation not matching the specifications discussed in these instructions will void the manufacturer s warranty. READ AND FOLLOW ALL AND CAUTION INFORMATION WHEN INSTALLING THIS APPLIANCE. Moving, Handling and Unpacking Remove and discard all packing materials, including cardboard and tape on the outside and inside of the warming drawer. Some stainless steel parts may have a plastic protective wrap which must be peeled off. The interior should be washed thoroughly with hot, soapy water to remove film residues and any dust or debris before being used, then rinsed and wiped dry. Solutions stronger than soap and water are rarely needed. 5

Installation 1 2 1 2 Pull out warming drawer pan until fully extended Slide finger along right and left side until you reach the hand latches (located approximately in the center of the rail). Pull up on on the left side latch and push down on the right side latch at the same time. Pull out the drawer pan. 3 4 Attach cord to the back of the control panel and plug into receptacle in cutout. Slide warming drawer cavity into the cabinet opening. To avoid an electrical shock hazard, make sure you only use the cord provided with the unit. Secure the warming drawer to the cutout using the four mounting screws which are provided. x4 5 Replace warming drawer pan assembly. 6

Final Preparation All stainless steel body parts should be wiped with hot, soapy water and with a liquid cleaner designed for this material. If buildup occurs, DO NOT use steel wool, abrasive cloths, cleansers, or powders! If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to loosen the material, then use a wool or nylon scraper. DO NOT use a metal knife, spatula, or any other material tool to scrape stainless steel! Scratches are almost impossible to remove. Service Information If service is required, call your authorized service agency. Have the following information readily available. Model number Serial number Date purchased Name of dealer from whom purchased Clearly describe the problem that you are having. If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact Viking Range, LLC at1-888-845-4641, or write to: Viking Range, LLC PREFERRED SERVICE 111 Front Street Greenwood, Mississippi 38930 USA Record the information indicated below. You will need it if service is ever required. The model and serial number for your warming drawer Rating/Serial plate is located on the left, rear side. Model no. Serial no. Date of purchase Date Installed Dealer s name Address If service requires installation of parts, use only authorized parts to insure protection under the warranty. 7

Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-845-4641 or visit our website at vikingrange.com 062390-000A EN (013018)