Issue 1.0 July Before installing and using this air conditioner, please read all the instructions carefully.

Similar documents
Heat Pump / Air Conditioner

Installation and User Manual

EH0533 Indoor Climate Control

EH0554 Indoor Climate Control

TECHNICAL MANUAL ICOOL/IWARM

PORTABLE AIR CONDITIONER (LOCAL)

PORTABLE AIR CONDITIONER (LOCAL)

CECx Destratification Fan

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

PORTABLE AIR CONDITIONER (LOCAL)

LOCAL AIR CONDITIONER

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Installation Instructions & Operating Manual IMPORTANT

Portable Room Air Conditioner and Heat Pump

PQ-A Electric Quartz Infrared Heaters

Local air conditioner

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

Stainless Steel Chimney Extractor

OPERATING INSTRUCTIONS

Dual-Hose Portable Air Conditioner User Manual

Up to 60 Pint Commercial Grade DEHUMIDIFIER

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

PORTABLE AIR CONDITIONER (LOCAL)

Owner s Manual Super-Slim Four-Way Cassette

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

Operating Instructions

INSTRUCTIONS AND WARRANTY

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

ARTICA. 8000Btu. Room Air Conditioners Portable Range

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

Inverter Split-type Room Air Conditioner

Flue & Flue Kits for NVx, VPC & NVS

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

Conception Wall Fire. Instruction Manual THE SCIENCE BEHIND CLEAN.

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

Installation Instructions

Mobile Air Conditioner Instruction Manual Model TC-N9KM

OPERATING INSTRUCTIONS

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

60cm Integrated Turbo Extractor

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

AIR COOLER WITH LED DISPLAY Model Number: IG9703

Imperial Electric Fires

IMPORTANT SAFETY INFORMATION:

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

KSD-35 DR11 KUE-35 DVN11

Stainless Steel T-Box Extractor

RCB53724MW RCB53724MX RCB53724VW RCB53724VX. User Manual Fridge Freezer USER MANUAL

5) Do not start or stop the unit by inserting or pulling out the power plug.

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

MeacoDry ABC Range Dehumidifiers

2kW Wall Mounted Electric Fire Complete with flat glass front panel. Installation Instructions & Operating Manual

Stainless Steel Chimney Extractor

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA


Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions

INSTALLATION & USER INSTRUCTIONS

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

12,000 BTU Evaporative Portable Air Conditioner

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

instructions for use Air Purifier with ionizer _00/

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

INSTALLATION & USER INSTRUCTIONS

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

OPERATING INSTRUCTIONS

IMPORTANT SAFETY INFORMATION:

Stainless Steel and Glass Angled Extractor

PORTABLE AIR CONDITIONER WITH HEATER ... WA-9061 H" 9,000 BTU WA H" 10,000BTU

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

Electric Fireplace Instruction Manual

Portable Electric Patio Heater User's manual

- Cooling - Heating - Dehumidifying - Fan. Please read this owner s Manual carefully before operating the unit. -1-

Bar Fridge USER MANUAL MB46W

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

CELSI ELECTRIFLAME XD

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

Mini Tower Fan NSMTF-18

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

R410A SPLIT SERIES FIXED SPEED

INSTALLATION & USER INSTRUCTIONS

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

MeacoCool MC Series Portable Air Conditioner

Transcription:

Issue 1.0 July 2013 Before installing and using this air conditioner, please read all the instructions carefully. Page 1 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

powrmatic Certificate of Waranty Dear Customer This is to certify that this air conditioner has a limited one year waranty from the date of original commissioning. The air conditioner must be commissioned within 4 weeks of installation. To make a claim In the first instance you must contact your appliance supplier, or installer and provide:- 1. The appliance type and serial number. 2. The original commissioning documentation. 3. As much detail as possible on the fault. Your supplier, of installer, will then contact Powrmatic to make a guarantee claim on your behalf. Conditions of Guarantee 1. The air conditioner must have been installed by a competent regognised instraller, and in accordance with the manufactures instructions, building regulations and local regulations. 2. The air conditioner has been professionally commissioned, within 4 weeks of installation, and a copy of the Commissioning Sheet returned to Powrmatic. 3. The air conditioner has been maintained on a yearly basis by a competent servicing company. 4. The air conditioner has been used in accordance with the manufactures instructions. 5. The correct specification voltage has been used. 6. No unauthorised repairs of modifications have been made. 7. Powrmatic General Conditions of Sales have been observed. 8. Except for the obligation of Powrmatic Ltd to perform warranty repairs during the guarantee period Powrmatic will not be liable in repect of any claim for direct or indirect consequential losses, including loss of profits or increased cost arising from loss of use of the air conditioner, or any event arising there from. ---------------------------------------------------- Powrmatic Ltd, Hort Bridge, Ilminster, Somerset, TA19 9PS Tel:01460 53535 Fax: 01460 52341 Web: www.powrmatic.co.uk e-mail service@powrmatic.co.uk Important: This certificate must be kept with the appliance Failure to provide a copy of the commissioning sheet invalidates the air conditioner waranty Installer Date : Signed Installer Commissioned Date : Signed Commissioning Engineer Page 2 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

Dear Customer - thank you for choosing Powrmatic. We appreciate you buying one of our high quality products and know that you have made the best choice. By choosing Powrmatic, you are investing in UK manufacturing & people. We pride ourselves by manufacturing products that provide clean, comfortable and safe working environments worldwide together with the personal & professional service and back-up you deserve. If you have any questions or concerns regarding this product, please contact our Technical Team by calling 01460 53535. In this manual you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner. You ll find many answers to common problems in the chart of troubleshooting tips. If you review the chart of Troubleshooting tips first, you may not need to call for service. The Climapac Must be Earthed and wired to current regulations. This product has been manufactured to comply with 2006/ 95/ EC and with amendments 92/31/ EEC and 93/ 68/ EEC. DISPOSAL: Do not dispose this product as unsorted municipal waste. Disposal of such waste separately for special treatment is necessary. Any batteries used in the remote control contain materials, which are hazardous to the environment. They must be removed from the remote control when they reach the end of their life and disposed of responsibly. Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013 Page 3

Users, Installation and Servicing Instructions C O N T E N T S Title Section Contents Page General Information 1.1 Introduction 5 1.2 Important Safety Instructions 5 1.3 Receiving the Goods 6 1.4 Handling 6 1.5 List of Accessories 6 1.6 Technical Features 7 Installation 2.1 Positioning the Air Conditioner 8 2.2 Paper Template 8 2.3 Drilling the Wall 10 2.4 Fastening the Anchors 11 2.5 Fitting the Gratings 11 2.6 Fixing the Plastic Sheet and Insulation 12 2.7 Connecting the Drainage Pipe 13 2.8 Fitting the air conditioner on Anchors 13 2.9 Power cord Connection 14 Use and Maintenance 3.1 Introduction of LCD Icons 15 3.2 Remote Control Functions 15 3.3 Heating Mode 16 3.4 Cooling Mode 16 3.5 Dry Mode 17 3.6 Fan Mode 17 3.7 Sleep Mode 18 3.8 Auto Mode 18 3.9 Timer Off Function 19 3.10 Timer On Function 19 3.11 Electrical Heat Function 20 3.12 Front panel Function 20 3.13 Install and Change the Battery 20 3.14 Maintenance 21 3.15 Problem Solving 22 Page 4 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

General Information 1.1 Introduction Please note: Don t dispose of any packaging until the installation of the air conditioner is complete. After, having removed the packing, check that all the contents are intact and complete. (see list of accessories). In the event of missing or damaged parts, please contact your retailer. This air conditioner has been designed to cool or heat the air in a room and should only be used for this purpose. The manufacturer cannot be held liable for damage caused to property or injury to persons or animals due to incorrect installation, not complying with current regulations, inadequate maintenance, or improper use. This air conditioner contains R410A refrigerant and, at the end of its life, the disposal of this air conditioner must be in accordance with the strict regulations regarding the recycling of this product. Please contact your local authority regarding disposal of this equipment. Do not switch the unit on before having completely assembled and installed the equipment in its correct operating position. Before starting the appliance, check that it is correctly earthed, in accordance with current regulations. 1.2 Important Safety Instructions When using electrical appliance, basic safety precautions should always be followed: Don t place objects on the air conditioner, or allow objects to obstruct the inlet or outlet openings. Extreme care should be taken when any air conditioner is in use near children and animals, and whenever the product is left unattended whilst in operation. Please Note: Before operating the air conditioner, ensure that all the packaging has been removed and the product has been check to see it is good condition. Do not allow children or pets to play with packaging (for example plastic bags). Do not operate the air conditioner with a damaged cord or plug, or if the unit is damaged or malfunctioning in any manner. If the unit is faulty, in any way, please contact your service engineer to examine and repair. Do not attempt to repair or adjust any electrical or mechanical functions on this air conditioner as this will invalidate your warranty. Always operate the product from a power source of the same voltage, frequency and rating as indicated on the product s identification plate. This air conditioner is not intended for use in wet or damp locations. Do not place the air conditioner near an open flame, cooking or heating appliance, or hot surface. Do not let the power cord hang over the edge of a table or a counter. Arrange the power cord away from an area where it may be tripped over. Never place the power cord under a carpet or rug. Do not operate the air conditioner in an area where petrol, paint, or other flammable liquid or gas is used or stored. Do not carry out any cleaning or maintenance or access internal parts until the air conditioner has been disconnected from the mains electricity supply. Do not alter the safety or regulating devices without permission and instructions of the air conditioner manufacturer. Do not pull, remove or twist the electrical cable connected to the air conditioner, even if disconnected from the mains electricity supply. Avoid prolonged direct contact with the flow of air from the air conditioner and the room being closed with no ventilation for a long period of time. Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013 Page 5

Repair or maintenance work must be carried out by a qualified service engineer or technician in compliance with the instructions given in this booklet. Do not alter the appliance, since hazardous situations could be created. The manufacture will not be liable for any damage or injury caused by such alterations. 1.3 Receiving the Goods This instruction booklet is an integral part of the appliance and should therefore be carefully preserved in the event of transfer to another owner or installation engineer. Should the booklet become damaged or lost please request an additional copy. The air conditioner is delivered in protective packaging and is accompanied by an instruction manual. This manual is an integral part of the air conditioner and should therefore be carefully read and retained. When the air conditioner is unpacked, please check that the air conditioner and accessories are all present, complete and undamaged. Be fully aware of the weight of the air conditioner before attempting to lift it. Take all necessary precautions to avoid damaging the product or causing personal injury. It is advisable to remove the packaging only when the air 1. REMOTE CONTROL 2. REMOTE CONTROL HOLDER 3. DRAINAGE PIPE 4. EXTERNAL GRATING 5. KIT OF SCREWS 6. INSTRUCTION MANUAL 1.4 Handling conditioner has been located in the point of installation. Carefully remove the adhesive strips positioned on the air conditioner. Packaging components must be tidied up correctly and not left within reach of children. 1.5 List of Accessories (P0) 7. PAPER TEMPLATE FOR WALL DRILLING 8. PLASTIC SHEET WITH INSULATION (2pcs) 628 x 500 x 15mm Page 6 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

1.6 Technical Features (P1, P2) Model Climapac Cooling capacity * W(Btu/H) 2362(8054) Heating capacity * W(Btu/H) 2230(7706) Electrical heater * W(Btu/H) 1600(5500) Rated voltage (V) 230 Absorbed power in cooling * (W) 873 Absorbed current in cooling * (A) 3.8 Absorbed power in heating * (W) 879 Absorbed current in Heating * (A) 3.8 Air flow (m 3 /h) 350 Noise level (db(a)) 48 Dehumidification capacity * (L/24H) 12.5 Optional temperature (remote control) 18/30 o C Fuse (T6.3A) 250V Refrigerant R410A Global warmer potential (GWP) 1900 Dimensions H/W/D(cm) 43/102/19.5 Net weight (kg) 42 * The above data could be changed in order to improve the performance of the unit. STANDARD TEST CONDITIONS EN 14511 - OPERATING CONDITIONS IN COOLING AND DEHUMIDIFICATION MODE - Inside 27 o C DB; 19 o C WB - Outside 35 o C DB; 24 o C WB OPERATING CONDITIONS IN HEATING MODE - Outside 7 o C DB; 6 o C WB - Inside 20 o C DB The display will show both setting temperature and ambient temperature. After adjusting the setting temperature, the setting temperature will flash 15 times on the display, then the display will show the ambient temperature for 70 seconds. After that, the display will be off until next adjustment. Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013 Page 7

Installation 2.1 Positioning the Air Conditioner (P3) To maintain the best performance from your air conditioner, prevent breakdowns or hazards, you must position it correctly. Please follow the guidelines and instruction below in full, as failure to do so could cause potential installation problems. The air conditioner must be installed on an exterior wall that has access to the outside with a minimum of 2 meters clearance to the outside.(see image P3) Please also ensure that there are no obstacles on the outside of the wall, which may obstruct air circulation through the drilled holes, for example:(plants and their leaves, slats or paneling, drain pipes, overflows and gratings, etc. ). Any obstruction could interfere with the correct performances of the air conditioner. The air conditioner must be fitted leaving room all around as illustrated in the paper template. The wall on which the air conditioner is installed must be sturdy and able to withstand the weight of the air conditioner. After determining the best place for installation as described above, please check to ensure that the wall can be drilled in the chosen area without interfering with other structures or installations (beams, pipes, wires, etc.). Fasten the template to the wall once the following guidelines have been thoroughly checked. 2.2 Paper Template (P4, P5) Do not drill any holes until you are completely confident that there are no obstacles in the area you wish to drill and there are no obstructions, which could be hidden by the construction of the wall, for example: electrical wiring, water and gas pipes or supporting lintels or beams. Ensure that a spirit level is used, as the air conditioner must be level. Follow the installation instructions in full. Fasten the template to the wall taking care to check the distance from the floor or ceiling. Use a pilot drill to mark the centre of each core hole to be drilled.(see image P5) Page 8 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013 Page 9

2.3 Drill the Wall (P6, P7, P8, P9) Please note: If you are drilling the hole above ground floor level, please ensure that an area at ground level under the hole positions has been roped off and is supervised, until drilling has been completed. INTAKE AND OUTLET HOLES (P6) This operation should be carried out using the proper tools (diamond tip core drills with high twisting torque and adjustable rotation speed). Find the hole centers previously drilled, and using a core drill having a diameter of 200mm drill the two holes for the intake and outlet air. It is recommended that the holes must have a slight downward inclination of 3-5 degrees to prevent any backflow of water from the pipes. (See image P7) DRAINAGE HOLE (P8) This air conditioner has a system to drain the condensate moisture automatically. Please read carefully the following instruction. Drill a hole through the wall measuring 30mm in diameter in the position shown in the paper template, marked the center before. Drainage occurs by gravity. For this reason, it is essential for the drain line to have a minimum downward inclination at least 3 degrees throughout its length. With this solution, you can drain the condensate moisture to a suitable place to not cause any problems to your neighbours. This drainage pipe needs to run to an area of natural drainage, where the water will not pool, or the runoff will cause issues, and be a problem if it were to freeze. Page 10 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

WALL BRACKET HOLES (P9) Drill the holes for anchoring the unit to the wall using the 2 holes with 10mm diameter showed in black on the paper template. As the unit is installed high on thewall, it is recommended that the bolts should be securely fixed. 2.4 Fastening the Anchors (P10) Insert the concrete anchors into the holes for the unit, and tighten them inside the wall. The anchor bolts provided require 10mm holes; the wall should be inspected to determine if provided bolts are suitable or if it is necessary to use a different anchorage. The manufacture is not liable in case of underestimation of the structural consistency of the anchorage made at the time of installation. 2.5 Fitting the Gratings After drilling the holes, the plastic gratings supplied with air conditioner need to be fitted on the wall. 1. When the gratings are easy accessible, from the outside, it is recommended to fasten them to the wall with wall plugs and 6mm diameter screws, and keep the fins in vertical position. (See image P11) Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013 Page 11

2. When the air conditioner is installed above the ground floor and it is impossible to reach the gratings from outside, fix the gratings from the inside as follows. Put the silicone gel around of the soft grating, see P12.Then fold the outer grating in half, insert your arm inside the hole with the grating. Let the grating unfold and pull the grating toward you. With a little patience and manipulation, the 2 gratings will fit the end of the holes. (P12,13,14) After fixing the outside grating, inject more gel inside the space between the grating and wall if required. (See P15,16) The black silicon gel is just an example, white or transparent colour gel could be usedt.(p17) The above installation solution is just for solid wall. 2.6 Fitting Plastic Sheet and Insulation After fixing the outside grating, insert the plastic sheet with insulation supplied with the conditioner into the holes. The sheets must be 107mm shorter than the thickness of the wall.(see P18) Use an ordinary cutter for the operation. (See P19) Roll the sheet and insert it into the hole, paying attention to the splicing line, which must always face upwards. (See P20) Page 12 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

2.7 Connecting the Drainage Pipe Connect the drain pipe (from rubber terminal) to the air conditioner (back side) after unplugging the black rubber cup (see P21). With this pipe in place, you can drain the condensate moisture to a suitable place which should not cause you or your neighbors any problems. 2. When the machine is installed in a very cold area, the water in the drainage pipe may become frozen easily in winter. 1. When the machine is installed in normal climate or hot area, connect the drainage pipe to outside, with an adequate piece of pipe. (See P22) 2.8 Fitting the Air Conditioner on Anchors After checking again that the fastening anchors are securely fastened to the wall, and that any necessary preparations for electric connection and condensate drainage have been made, fasten the air conditioner to its supporting anchors.(see P24) Lift it up by holding the sides at the bottom, slightly insert the outside fan rings into the two big holes on the wall. (See P25) The air conditioner can now be pushed firmly against the wall, then lift the unit and make sure the anchors and unit match up. (See P26) Inspect carefully the installation to make sure that the insulating back panel fits firmly against the wall and there are no gaps at the back of the air conditioner. Fixing two nuts with top of the machine, to make sure the unit is installed securely. ( See P25, 26) Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013 Page 13

The appliance shall not be installed in a laundry. The appliance must be positioned so that the plug is accessible. The appliance shall be installed in accordance with wiring regulations. 2.9 Power Cord Connection For every unit, there would be a power cord on the left side (P28).Connect the plug with the socket, and operate the unit. Page 14 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

Use and Maintenance 3.1 Introduction of LCD Icons 3.2 Remote Control Functions (1) MODE BUTTON: Set up the air conditioner operating mode (2) ON/OFF BUTTON: Turn on or turn off the air conditioner (3) UP BUTTON: Increase the temperature and time (4) DOWN BUTTON: Decrease the temperature and time (5) FAN SPEED BUTTON: Set up the fan speed. (6) TIMER ON BUTTON: Set up the time the air conditioner starts. (7) TIMER OFF BUTTON: Set up the time the air conditioner stops (8) CLOCK BUTTON: Adjust the clock (9) LOUVER SWING BUTTON: Adjust the airflow direction (10) SLEEP BUTTON: Automatically shutting down the unit after a given time. (11) RESET BUTTON (12) ELECTRICAL HEAT BUTTON: Switch on the electrical heat in order to get enough heating capacity in very cold weather. Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013 Page 15

3.3 Heating Mode Sequence of Operation 1) Press the ON/OFF button (2), to switch on the air conditioner, it will start in memory mode. 2) Press the MODE Button (1), till the Heat flame symbol shows, the air conditioner will now run in Heating mode. 3) Press the UP and DOWN buttons (3) and (4) to adjust the set temperature. 4) Press the FAN SPEED button (5) to adjust the fan speed from Low, Medium, High or Auto speed (Symbol flashes). For auto fan, the speed is chosen by the difference of room temperature to the setting temperature. 5) Press the ON/OFF button (2), to switch off the air conditioner. The next time the air conditioner is turned on, the air conditioner will revert to this setting. 3.4 Cooling Mode Sequence of Operation 1) Press the ON/OFF button (2), to switch on the air conditioner, it will start in memory mode. 2) Press the MODE Button (1), till the Cool Snowflake symbol shows, the air conditioner will now run in Cooling mode. 3) Press the UP and DOWN buttons (3) and (4) to adjust the set temperature. 4) Press the FAN SPEED button (5) to adjust the fan speed from Low, Medium, High or Auto speed (Symbol flashes). For auto fan, the speed is chosen by the difference of room temperature and the setting temperature. 5) Press the ON/OFF button (2), to switch off the air conditioner. The next time the air conditioner is turned on, the air conditioner will revert to this setting. Page 16 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

3.5 Dry Mode Sequence of Operation 1) Press the ON/OFF button (2), to switch on the air conditioner, it will start in memory mode. 2) Press the MODE Button (1), till the Dry drip symbol shows, the air conditioner will now run in Drying mode. 3) Press the UP and DOWN buttons (3) and (4) to adjust the set temperature. 4) The FAN SPEED button (5) is disabled in this operation, as the fan speed is always set to low in drying mode. 5) Press the ON/OFF button (2), to switch off the air conditioner. The next time the air conditioner is turned on, the air conditioner will revert to this setting. 3.6 Fan Mode Sequence of Operation 1) Press the ON/OFF button (2), to switch on the air conditioner, it will start in memory mode. 2) Press the MODE Button (1), till the Fan propeller symbol shows, the air conditioner will now run in Fan mode. 3) Press the UP and DOWN buttons (3) and (4) to adjust the set temperature. 4) Press the FAN SPEED button (5) to adjust the fan speed from Low, Medium, High or Auto speed (Symbol flashes). For auto fan, the speed is chosen by the difference of room temperature and setting temperature. Room temperature is less than the set temperature by more than 5 o C the the fan works at high speed. Room temperature is less than the set temperature by more than 3 o C the the fan works at medium speed. Room temperature is less than the set temperature by more than 1 o C the the fan works at low speed. 5) Press the ON/OFF button (2), to switch off the air conditioner. The next time the air conditioner is turned on, the air conditioner will revert to this setting. Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013 Page 17

3.7 Sleep Mode Sequence of Operation 1) Press the ON/OFF button (2), to switch on the air conditioner, it will start in memory mode. 2) Press the MODE Button (1), till the Heat flame, Cool snowflake (heat pump) or auto triangle symbol shows, the air conditioner will now run in the mode set. 3) Press the UP and DOWN buttons (3) and (4) to adjust the set temperature. 4) Press the SLEEP button (10), the moon icon will be displayed on the LCD, the sleep function has now been set up, press the SLEEP button (10) again to cancel the sleep function. 5) If the sleep function is set up the fan speed is set automatically to low speed. 3.8 Auto Mode Sequence of Operation 1) Press the ON/OFF button (2), to switch on the air conditioner, it will start in memory mode. 2) Press the MODE Button (1), till the Auto Triangle symbol shows, the air conditioner will now run in Auto mode. 3) According to the difference in the room temperature the air conditioner will select the operation mode (heat, fan, cool) The UP and DOWN buttons (3) and (4) are disabled. When the room temperature is 20 o C the air conditioner will run in heat mode. When the room temperature is < 25 o C and >20 o C the air conditioner will run in fan mode. When the room temperature is 25 o C the air conditioner will run in cool mode. 4) Press the FAN SPEED button (5) to adjust the fan speed from Low, Medium, High or Auto speed (Symbol flashes). For auto fan, the speed is chosen by the difference of room temperature and setting temperature. 5) Press the ON/OFF button (2), to switch off the air conditioner. The next time the air conditioner is turned on, the air conditioner will revert to this setting. Page 18 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

3.9 Timer Off Function Sequence of Operation 1) Press the ON/OFF button (2), to switch on the air conditioner, it will start in memory mode. 2) Press the MODE Button (1), till the required symbol is shows, operation you require, the air conditioner will now run in this mode. 3) Press the UP and DOWN buttons (3) and (4) to adjust the set temperature. 4) Press the FAN SPEED button (5) to adjust the fan speed from Low, Medium, High or Auto speed (Symbol flashes). For auto fan, the speed is chosen by the difference of room temperature and setting temperature. 5) Press the TIMER OFF button (7), to to set up when you require the air conditioner to switch off. Press the UP button (3) to increase the time by 1 hour and DOWN button (4) to increase the time by 1 minute. When the time is over the air conditioner will switch off automatically. If the TIMER OFF button (7), is pressed before the unit switches of then this operation will be cancelled. 3.10 Timer On Function Sequence of Operation 1) The air conditioner is switched off. 2) Press the TIMER ON Button (6). 3) Press the MODE Button (1), till the required symbol is shows, operation you require, the air conditioner will now run in this mode. 4) Press the UP and DOWN buttons (3) and (4) to adjust the set temperature. 5) Press the FAN SPEED button (5) to adjust the fan speed from Low, Medium, High or Auto speed (Symbol flashes). For auto fan, the speed is chosen by the difference of room temperature and setting temperature. 6) When the time is reached the air conditioner will turn on. By pressing the TIMER ON Button (6) again this operation will be cancelled. Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013 Page 19

3.11 Electrical Heat Mode Sequence of Operation 1) Press the ON/OFF button (2), to switch on the air conditioner, it will start in memory mode. 2) Press the MODE Button (1), till the Heat flame symbol shows, the air conditioner will now run in heating mode. 3) Press the UP and DOWN buttons (3) and (4) to adjust the set temperature. 4) Press the FAN SPEED button (5) to adjust the fan speed from Low, Medium, High or Auto speed (Symbol flashes). For auto fan, the speed is chosen by the difference of room temperature and setting temperature. 5) Press the assisted ELECTRICAL HEAT button (12) the icon will display on the LCD. Pressing the assisted ELECTRICAL HEAT button (12) again will cancel the assisted heat function. 6) Press the ON/OFF button (2), to switch off the air conditioner. The next time the air conditioner is turned on, the air conditioner will revert to this setting. When the unit starts working, the front panel and flap will open completely at first. About 15-20 seconds later, the indoor fan and compressor will work as mode setting, and front panel will stay in the open position when the unit is working. During the front panel opening period, the indoor fan will not work, and there is no air coming out from the air conditioner. If unit is closed, the indoor fan will stop first, and then front panel and flap will close completely again. 3.12 Front Panel Function 3.13 Install and Changing the Batteries --To Open the battery cover, pull back the hook and lightly pull up. -- Insert the battery (AAA, 2 pcs), the positive must be same as that marked on the plastic surface. --Reinstall the battery cover, Check to see that the LCD display comes on when you press the ON/OFF button (2), if not re-check the polarity of the batteries. Page 20 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

FILTER CLEANING 3.14 Maintenance (P31, P32, P33) The filter should be regularly cleaned to keep the air conditioner running efficiently. Clean the filters every two weeks. How to proceed: -- Disconnect the air conditioner from the electrical supply. -- Open the front panel by hand. -- Take the filter holder (See P31),take out the filter grating from the slot. (See P32). -- Proceed to wash them (not hot water)and only when they are dried replace them in the same way.(see P33) ATTENTION: Do not use the air conditioner without filters as it could seriously damage the air conditioner. EXTERNAL CLEANING -- Disconnect the air conditioner from the electrical supply. -- Wipe external surfaces clean with a damp cloth only. -- Do not use an abrasive cloth or solvents, as this may damage the surfaces. -- Do not use excessively wet cloths or sponges, as water stagnation could damage the air conditioner and compromise safety. ACTIVE CARBON FILTER (OPTIONAL) (P34) The unit may includes active carbon filter, which not only has the function of eliminating suspended matter that a common mechanical filter can t, but also can eliminate foreign matter such as free chlorine, odours, colours and toxic matters that are difficult to filter out by using conventional approaches. With active carbon filter, the room air would be fresh and good for the body health. Is advisable to change them every three months, because it is not possible to wash or clean them. Page 21 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

3.15 Problem Solving PROBLEM POSSIBLE CAUSES -The air conditioner does not work. -The air conditioner does not refrigerate the room. -Strange smell in the room. Water drips from the air conditioner. -The remote control does not work. -The air conditioner does not work for 3 min when switched on. POSSIBLE SOLUTIONS 1.Wrong setting of the timer/check it. 2.Problems on the power supply/call the service center. 3.The filter could be dirty/clean it. 4.The room temperature is too high/wait until the temperature goes down. 5.The temperature is not properly set/check it. 6.The air grilles could be obstructed/check and remove the obstacles. Other possible causes of problems -Dampness in the room, coming from walls, carpets, furnishing or similar. -Wrong installation of the air conditioner. -Wrong connection of the drainage pipe. -Exhausted batteries. -Wrong insertion of the batteries inside the remote control. -Protection of the conditioner. Wait for 3 min and the air conditioner will start to work again. If the supply cord damaged, it must be replaced by manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. The max operation temperature for the air conditioner: (max cooling: outdoor DB 43 o C / WB 26 o C, indoor DB 32 o C/WB 23 o C; min heating: outdoor DB -5 o C /WB -6 o C,indoor Db 20 o C) This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Page 22 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013

Disposal of your old appliance 1. When this crossed-out bin symbol appears on a product it means that the product is covered by European Directive 2002/96/EC. 2. All electrical and electronic products should be disposed of separately from the municipal waste stream via specific collection facilities designated by the government or the local authorities. 3. Proper disposal of your old appliance will help prevent potential negative consequences for the environment and human health. 4. For more detailed information about disposal of your old appliance, please contact your municipality, the waste disposal service or the Installer. Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013 Page 23

Installer:- Installed by Date.... Service 1 :- Serviced by Date.... Service 2 :- Serviced by Date.... Service 3 :- Serviced by Date.... HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: 01460 53535 Fax: 01460 52341 Every effort is made to ensure accuracy at time of going to press. However as part of our policy of continued product improvement, we reserve the right to alter specification without prior notice. Page 24 Climapac Twin Duct High Wall Air Conditioner Users, Installation & Service Instructions Issue 1.0 July 2013