Numerical Evaluation of Performance Curves of a High Frequency Microcompressor

Similar documents
Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

An Experimental-Numerical Procedure to Characterize Compressor Performance under Cycling Operating Conditions of Refrigerators

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

Performance Evaluation of a Plug-In Refrigeration System Running Under the Simultaneous Control of Compressor Speed and Expansion Valve Opening

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Sub-Critical Operation of the CO2 Expander/ Compressor

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Purdue e-pubs. Purdue University

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

Mini Vapour Cycle System For High Density Electronic Cooling Applications

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

Dynamic Simulation of Liquid Chillers

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

Performance of CO2 Cycles with a Two-Stage Compressor

Numerical Simulation of a New Cooling System for Commercial Aircrafts

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

R32 Compressor for Air conditioning and Refrigeration applications in China

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Compressor Capacity Control

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

A Review of Household Compressor Energy Performance

A Study on Compression Characteristic of Wet Vapor Refrigerant

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

High Efficiency R-134a Compressor for Domestic Refrigerator

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Dynamic Simulation of HFC-134a Flow Through Adiabatic and Non-Adiabatic Capillary Tubes

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Diagnosing Troubles in Refrigeration Units with Screw Compressors

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Efficiency of Non-Azeotropic Refrigerant Cycle

Experimental and Numerical Steady-State Analysis of a Top-Mount Refrigerator

Low GWP Refrigerants for Air Conditioning Applications

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Modular Simulation of Vapour Compression Systems With an Object Oriented Tool

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Experimental comparison of a cascade refrigeration system operating with R744/R134a and R744/ R404a.

Performance of an Improved Household Refrigerator/Freezer

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Exploring the Performance Characteristics of CO2 Cycles in a Breadboard-Type Test Facility

A New Control Approach for a Direct Expansion (DX) Air Conditioning (A/C)System with Variable Speed Compressor and Variable Speed Supply Fan

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor

Development of Large Refrigerant Compressors

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Optimization of Compressors used in Air Conditioning Units

Compressor Capacity Control: A New Direction

Higher Efficiency, Lower Sound, and Lower Cost Air Conditioning Compressors: Part 1 Efficiency

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

Two-Phase Evaporation Pressure Drop Experimental Results for Low Refrigerant Mass Flux

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

An Experimental and Theoretical Study on System Performance of Refrigeration Cycle Using Alternative Refrigerants

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

HSPF Calculation of a System Allowing Switching Between a Single-Stage to a Two-Stage Compression System

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Thermal Modelling for the Motor in Semi-hermetic Screw Refrigeration Compressor under Part-load Conditions

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Study of R161 Refrigerant for Residential Airconditioning

Transcription:

Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2012 Numerical Evaluation of Performance Curves of a High Frequency Microcompressor Celso Kenzo Takemori celsokenzo@gmail.com Fabian Fagotti Follow this and additional works at: http://docs.lib.purdue.edu/icec Takemori, Celso Kenzo and Fagotti, Fabian, "Numerical Evaluation of Performance Curves of a High Frequency Microcompressor" (2012). International Compressor Engineering Conference. Paper 2131. http://docs.lib.purdue.edu/icec/2131 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

Numerical Evaluation of Performance Curves of a High Frequency Microcompressor Celso Kenzo TAKEMORI 1, Fabian FAGOTTI 2* 1 Embraco, Research and Development Joinville, Santa Catarina, Brazil celsokenzo@gmail.com 2 Embraco, Research and Development Joinville, Santa Catarina, Brazil Fabian_Fagotti@embraco.com.br * Corresponding Author 1461, Page 1 ABSTRACT This work presents a methodology for the numerical simulation of reed valves of a small-size reciprocating compressor (approximately 200 mm in length, 60 mm in diameter), oil free and operating at high frequency. A fluidstructure interaction methodology is employed, where the fluid domain is modeled by the tridimensional transient Navier-Stokes equations, while the solid domain is governed by a beam model considering geometrical contacts between valves and stoppers (valve plate, piston, etc.) Results are shown for mass flow, pump power consumption and valve losses for evaporating temperatures ranging from -15 degrees Celsius to +40 degrees Celsius, and condensing temperatures from +45 degrees Celsius to +85 degrees Celsius. Finally, numerical results were compared to experimental data. 1. INTRODUCTION Cooling and refrigeration of portable systems and electronic equipments such as IT systems, displays, projectors, industrial enclosures and cooled vests demands a large cooling capacity and small size at evaporating temperatures much higher than that found on typical refrigeration systems. For example, in electronics cooling it is important to maintain the temperature as low as possible, but above the dew point. In some cases the evaporating temperature is just a bit lower than the ambient temperature as a way to ensure that no condensation of moisture will occur. Typically, electronic equipments work surrounded by air at 30 to 50 [ C]. Possamai et al. (2008) demonstrated that a linear motor with a reciprocating piston, both operating at frequencies a way higher than the traditional 50/60 [Hz] is the most suitable solution for small scale cooling and refrigeration systems, with the benefit that the compressor could operate without any oil (oil free). Shiomi et al. (2009, 2010, 2011) applied numerical methods to accurately predict the behavior of a reciprocating compressor with reed valves, showing very good agreement between the numerical and the experimental results in terms of pressure-volume diagram, valve displacement and pressure pulsations at the suction line. Takemori (2009) adapted the methodology developed by Shiomi et al. (2009, 2010, 2011), replacing the single degree of freedom parallel motion of the valves by a beam model. Moreover, Takemori (2009) explored the influence of various numerical parameters (advection and transient schemes, convergence criteria and temporal discretization) on the behavior of a miniaturized compressor operating at 350 [Hz].

1461, Page 2 That said, the objective of this work is to evaluate the performance of a high frequency miniaturized compressor (Figure 1, Figure 2 and Figure 3) under a wide range of evaporating and condensing temperatures, focusing on temperatures typically found on electronics cooling applications. Compressor Inverter Figure 1: Photography of the high frequency miniaturized compressor. The weight of the compressor with inverter is 1300 grams. Figure 2: Top view of the compressor showing main dimensions. Figure 3: Back view of the compressor showing main dimensions. All results presented correspond to an oil free miniature reciprocating compressor with these specifications: - Operating frequency: 335 [Hz] - Volumetric displacement: 0.267 [cm 3 ] - Dead volume: 0.0351 [cm 3 ]

1461, Page 3 2. METHODOLOGY 2.1 Numerical procedure The numerical procedure follows a fluid-structure interaction methodology (Takemori, 2009) where the fluid domain is modeled by the tridimensional transient Navier-Stokes equations, while the solid domain is governed by a beam model considering geometrical contacts between valves and stoppers (valve plate, piston and discharge stopper). 2.1.1 Fluid domain: The fluid domain includes the suction line, chamber, tubes and orifices, the cylinder, and the discharge orifices, chamber and line (Figure 4). Suction line Suction chamber Discharge line Suction tube Suction tube Discharge chamber Figure 4: Fluid domain. The compressor has a total of four valves: Two suction valves and two discharge valves (Figure 5). With that configuration it was possible to achieve a very good tradeoff between fluid flow area and valve stiffness and natural frequency.

1461, Page 4 Suction orifice Suction orifice Suction valve Suction valve Discharge orifice Discharge orifice Discharge valve Discharge valve Figure 5: Enlarged view of the fluid domain. The compressor works with R134a modeled with Aungier Redlich Kwong equation of state (ANSYS, 2011). The energy equation considers all terms, including the viscous work. Based on the research of Shiomi (2011), the SST turbulence model was chosen. The suction line has as boundary condition pressure equals to the evaporating pressure and temperature of 60 [ C]. The discharge line has an outlet boundary condition with a pressure set equals to the condensing pressure. Piston displacement follows a sinusoidal motion, since the compressor works with a resonant mechanism. All walls were considered adiabatic. 2.1.2 Solid domain: The mathematical model that governs the solid domain is the classical pure bending Euler beam model. As a means to facilitate the input of data, the beam properties are replaced by two only: Natural frequency and equivalent stiffness (Figure 6). Figure 6: Solid domain based on beam model. 2.1.3 Fluid-solid coupling follows an explicit scheme (Figure 7) considering variable time step in order to reduce the computational time. One time step value is used for compression and expansion, other for suction process and another for discharge process.

1461, Page 5 Initial conditions 3D transient flow equations Transfer loads to structural model Solve structural dynamics (beam model) Transfer displacements to fluid domain Increment time No Time > End time? Yes End Figure 7: Fluid-solid coupling. 2.2 Experimental setup Measurements were made according to the procedure described by Shiomi (2010). The experimental setup (Figure 8) is composed by control valves (CV), mass flow meter (FM), heat exchangers (HX), thermocouples (TC) and pressure transducers (PT). The measurement is carried out in a way that the R134a can flow through the high and low pressure lines in the superheated state, as indicated in Figure 8b. According to this arrangement, refrigerant enters the compressor (C) at point 1 and is compressed to point 2. After that, the fluid is cooled and expanded (2-3- 4), and the mass flow is measured. The refrigerant is cooled again and throttled to the evaporation pressure (6). Finally, the suction line temperature is adjusted by an electrical heater (EH1), completing the operating cycle. Figure 8: Experimental setup (Shiomi, 2010). (a) Layout schematic. (b) Superheated cycle representation. 3. RESULTS A comparison between the experimental data and the results predicted by the numerical procedure (Figure 9) shows a very good agreement. The estimate is a bit higher probably due to a bigger dead volume on the experimental setup.

1461, Page 6 Figure 9: Mass flow rate for evaporating temperature ranging from -5 to +40 [ C] and condensing temperatures ranging from +45 to +85 [ C]. Analyzing the results for the condensing temperature of 85 [C], it is possible to notice that the experimental and the estimated results differ for evaporating temperatures above 25 [C]. It occurs due to a limitation on the experimental side, where the electric motor can't supply the necessary power to the pump, and the electronic control of the compressor compensates that with a reduction on the volumetric displacement and an increase on dead volume. This reduction leads to lower mass flow rate. Figure 10: Mass flow rate for evaporating temperature ranging from -5 to +40 [ C] and condensing temperatures ranging from +45 to +85 [ C]. It is possible to evaluate an ideal mass flow rate based solely on volumetric displacement, operation frequency, dead volume, pressure ratio, specific heat ratio and density at suction (Gomes, 2006). Figure 10 shows the ideal and the estimated mass flow rate. Notice that the difference between these results is relatively small at a condensing temperature of 45 [C], and becomes larger when the condensing temperature rises. This behavior can be explained by a difference on dead volume. Figure 11 shows the ideal mass flow rate with a bigger dead volume (0.055 instead of 0.035 [cm 3 ]). It is clear now that both results are very similar.

1461, Page 7 Figure 11: Mass flow rate for evaporating temperature ranging from -5 to +40 [ C] and condensing temperatures ranging from +45 to +85 [ C]. In both cases - experimental and numerical - the fact that the effective dead volume is larger than the geometric dead volume needs to be better understood. Knowing the pump power consumption is important to design or redesign the electric motor. Figure 12 shows the indicated power for the various conditions of evaporating and condensing temperatures. Figure 12: Indicated power (or pump power consumption). Figure 13 shows suction and discharge losses as a percentage of indicated power. As a typical value is 8% (Shiomi, 2011), it is important to analyze in detail the flow field in order to identify the causes of the significant losses.

1461, Page 8 Figure 13: Suction and discharge losses. From a computational point of view, all cases ran in approximately 8 hours per cycle, running on 2 parallel processes (Workstation Dell T3500, Intel Xeon E5630, 12 GB DDR3, Microsoft Windows XP Professional x64 Edition Version 2003 Service Pack 2, CFX 13.0 SP2 2011.03.31-11.04, HP-MPI Local Parallel). It was not possible to see any significant reduction on computational time running the cases on 4 or more processes, probably because of the reduced mesh size (80777 nodes). 4. CONCLUSIONS This work presented the performance curves of a high frequency miniaturized compressor using both numerical simulation and experimental measurements. The results showed a very good agreement between these two methods. Moreover, the numerical analysis showed that the suction and discharge losses are considerably higher than typical values. A detailed study of the flow field can provide important information to improve the compressor efficiency. Finally, some issues should be addressed on future works. An ideal mass flow rate model showed that the performance of the compressor can be considerably higher, and it needs to be better understood. REFERENCES Ansys Inc., 2011, ANSYS CFX-Solver Theory Guide v.13.0. Gomes, A. R., Deschamps, C. J., 2006, Análise comparativa de mecanismos de compressão para aplicação em refrigeração doméstica, UFSC - Universidade Federal de Santa Catarina, Brazil, 136 p. Possamai, F., Lilie, D. E. B., Zimmermann, A. J. P., Mongia, R., 2008, Miniature Vapor Compression System, International Refrigeration and Air Conditioning Conference at Purdue, Purdue University, USA. Shiomi, F. H., Takemori, C. K., Deschamps, C. J., 2009, Comparative analysis of different modeling approaches for valve dynamics of small reciprocating compressors, IIR Compressors, Papiernička, Slovakia. Shiomi, F. H., Deschamps, C. J., Takemori, C. K., 2010, Modeling strategies for the dynamics of reed type valves, Proceedings of ENCIT, ABCM - Associação Brasileira de Engenharia e Ciências Mecânicas, Brazil. Shiomi, F. H., Deschamps, C. J., 2011, Modelação da dinâmica e da tensão de flexão de válvulas tipo palheta de compressores alternativos de refrigeração, UFSC - Universidade Federal de Santa Catarina, Brazil, 104 p. Takemori, C. K., 2009, Numerical simulation of the fluid-structure interaction applied to the reed valves of a miniaturized compressor under high frequency conditions, International Conference on Compressors and their Systems, Institute of Mechanical Engineers, UK, p. 155-162.