www.tsurumi-global.com LHW HIGH HEAD DRAINAGE PUMPS
Submersible High Head Drainage Pumps Tsurumi LH/LH-W series pumps are submersible heavy-duty pumps specialized for high head. These pumps are available in a wide lineup, offering to 1kW motor output and 18 to 2m maximum head. The LH/LH-W series has played an active role in various fields, from small/medium-scale civil engineering and construction work that requires high reliability, to large-scale projects for constructing tunnels, bridges and dams. And, because of the slim body, these pumps have particularly helped to drain mine pits where required to work in limited space. So that they can stand up to harsh environment, these pumps have the impeller and mouth ring made of high-chromium cast iron that provides high wear resistance. The pump is equipped with seal pressure relief ports* that release pump pressure applied to the mechanical seal. urthermore, to endure even extended operation at low water level, these pumps feature flow-thru design that forcibly cools down the motor. With these features, Tsurumi pumps provide excellent reliability and durability that enables continuous duty for long periods of time. * excluding kw Available as optional specifications are a proprietary seawater-resistant pump developed over many years by Tsurumi to enable seawater intake/drainage for long periods of time, and an all stainless steel pump using 1 stainless steel for mining markets. LH: Lineup of pumps with high head in consideration of discharge volume. LH-W: Comprised of dual impellers for extra high head. Selection Table LH ( Impeller) Discharge Bore LH-W (Dual Impellers) kw 15kW 19kW 22kW kw 7kW 45kW 55kW 75kW 9kW 1kW kw 5.5kW 11kW 22kW kw 1kW 2" mm " mm 4" mm " mm 8" mm Model Number Designation Name of the series Rated motor output in kilowatts LH 22 W Discharge bore in inches Options Number of impellers W : Dual impellers None : impeller Seawater-resistant version; Galvanic anode & Special impeller High temperature liquid version; Max. 9 High voltage version; Max. V All stainless steel version; 1 S.S. 2
Seawater-Resistant Kit Top Discharge, low-thru Design Tsurumi s pumps can be combined with a seawater-resistant kit (optional) that adds a galvanic anode and seawater-resistant special cast iron impeller, and enables about two years of service. (The service period depends on operating conditions.) This design provides maximum motor cooling efficiency allowing continuous operation at low water levels and extended dry-run capability, and also allows the shape of the pump to be cylindrical and slim for installation in a well casing for deep well dewatering. Model LH41W 1 2 All Stainless Steel Pump All of the parts of Tsurumi s pumps that contact fluid, including the impeller, pump casing, motor frame, outer cover, strainer stand, and flange, can be made in 1 stainless steel. Tsurumi s all stainless steel pump can handle corrosive fluids generated in mines or quarries, and fluids of unexpectedly high ph. or details, contact your dealer. 5 4 7 8 1 Anti-wicking Cable Entry Prevents water incursion due to capillary wicking should the power cable be damaged or the end submerged. 2 Motor Protector CTP (22kW and below) Detects excess heat, therefore, protecting the pump against overheating and dry-running. MTP (kw and above) React to excessive heat caused by dry-running. The bimetal strip opens to cause the control panel to shut the power supply. Dual Inside Mechanical Seals with Silicon Carbide aces Isolated in the oil chamber where a clean, non-corrosive and abrasion-free lubricating environment is maintained. Compared with the water-cooled outside mechanical seal, it reduces the risk of failure caused by dry-heating and adhering matter. The Silicon carbide provides 5 times higher corrosion, wear and heat resistance than the tungsten carbide. 5 Leakage Sensor (55kW and above) Detects flooding into the oil chamber that may occur in a worst case scenario. When flooding is detected, signals are sent to operate the indicator lamps through the external control panel. Seal Pressure Relief Ports (excluding kw) Protect the mechanical seal from pump pressure. They also protect the seal face by discharging wear particles. 7 Closed Impeller & Mouth Rings Resists wear caused by abrasive particles and enables the pump to maintain its original performance for an extended period of time. LH: impeller LH-W: Dual impellers 8 Galvanic Anodes (excluding kw) Protect the pump against corrosive potential generated during the drainage of wastewater. 4 Oil Lifter [Patented] Provides lubrication and cooling of the seal faces down to 1/ of normal oil level, thus maintaining a stable shaft sealing effect and prolonging seal life longer. 4
LH. LH - Impeller- The LH-series is a submersible three-phase cast iron high head drainage pump. Being the pump cylindrical and slim, it can be installed in a well casing for deep well dewatering. The center flange construction assures a stable installation even if it is fixed by the discharge pipe. The top discharge, flow-thru design provides maximum motor cooling efficiency allowing continuous operation at low water levels and extended dry-run capability. The pump incorporates seal pressure relief ports that prevent the pumping pressure from applying to the shaft seal.* * excluding LH. Performance Curves < mm > LH4 LH422 S.S. min -1 S.S. min -1 LH422 LH4 LH. 1 2 1 2 < mm > S.S. min -1 S.S. min -1 LH1 LH1 LH9 LH9 LH. LH7 LH81 LH75 LH45 LH7 LH75 LH45 LH7 Discharge Bore Model LH. LH422 LH4 LH15 LH19 LH22 LH7 LH45 LH75 LH9 LH1 LH87 LH845 LH855 LH875 LH89 LH81 Motor Output 22 15 19 22 7 45 75 9 1 7 45 55 75 9 1 Phase Three Starting Method D.O.L. Solids Passage 8.5 12 12 8 Dimensions L x H 185 x 45 4 x 152 4 x 152 x 14 4 x 142 4 x 142 5 x 1448 5 x 1448 5 x 17 592 x 1787 592 x 1787 5 x 1448 5 x 1448 5 x 171 5 x 171 592 x 1787 592 x 1787 Dry Weight* 2 mm kw mm mm kg m * 1 available upon request * 2 Weights excluding cable 42 55 21 495 5 85 1 495 5 8 85 1 12 Cable Length 1 2 4 5 1 2 4 5 < mm > 1 LH19 LH15 LH81 LH89 LH875 LH845 LH855 LH87 LH22 S.S. min -1 S.S. min 1-1 1 2 4 5 7 1 2 4 5 7 LH19 LH15 LH875 LH845 LH81 LH89 LH22 LH855 LH87 5
LH-W -Dual Impellers- The LH-W-series is a submersible three-phase cast iron extra high head drainage pump having dual impellers. Being the pump cylindrical and slim, it can be installed in a well casing for deep well dewatering. The center flange construction assures a stable installation even if it is fixed by the discharge pipe.* 1 The top discharge, flow-thru design provides maximum motor cooling efficiency allowing continuous operation at low water levels and extended dry-run capability. The pump incorporates seal pressure relief ports that prevent the pumping pressure from applying to the shaft seal.* 2 * 1 excluding LH41W * 2 excluding LH2.W Performance Curves < -kw > 1 1 LH25.5W LH25.5W LH2.W LH22W LH11W LH4W S.S. min -1 S.S. min -1 1 1 LH25.5W LH25.5W LH2.W LH22W LH11W LH4W.2.4..8 1. 1.2 1.4.2.4..8 1. 1.2 1.4 < 1kW > 2 2 2 S.S. min -1 2 S.S. min -1 2 2 LH2.W LH11W LH41W 2 19 1 17 LH41W 2 19 1 17 LH41W LH41W 1 1 Discharge Bore Model Motor Output Phase Starting Method Solids Passage Dimensions L x H Dry Weight* 2 mm kw mm mm kg m Cable Length 1. 2. 1. 2. LH2.W D.O.L. 185 x 4 LH25.5W 5.5 254 x 7 LH11W LH22W 11 22 Three 8.5 8.5 27 x 24 x 125 1 4 LH4W 8.5 5 x 175 24 LH41W 1 8 1 x 1825 127 * 1 available upon request * 2 Weights excluding cable 7 8
Tandem Operation Tandem operation is an operation method that connects two pumps of the same model in series. This provides double pump head at the same flow rate in comparison with that of a single pump. The principle of tandem operation is the same as that with multistage pumps. Lifting Chain or Wire Rope Discharge Head of Upper Stage Pump Precautions for Selection and Use or model selection, piping and installation procedure, be sure to consult Tsurumi distributors in advance. 1. If the required total head exceeds the maximum head of the pump without the intermediate connection pipe shown in the selection table, insert a intermediate connection pipe of a length corresponding to the excess amount or more, to reduce the pressure applied to the pump in the upper stage. 2. Check the approximate weight of one pump and the allowable load for two eyebolts (per pump) shown in the selection table, and determine the piping weight, installation method and lifting procedure so that the allowable load is not exceeded. Seal Pressure Relief Port Lower Pump Casing for Tandem Connection Companion lange (Option) Intermediate Connection Pipe. The pump in the lower stage should be installed at the bottom of the vertical hole, unless special measures are taken. Do not suspend the pump in midair. Do not allow the weight of the upper pump and piping to be applied to the lower pump. 4. Since a certain amount of water spouts from the seal pressure relief port,* both the upper- and lower-stage pumps should be installed in the vertical hole. Do not use the pumps as booster pumps in the middle of a horizontal line lying on the ground. * excluding LH. and LH2.W 5. Do not connect pumps of different models in series. Do not use either of two connected pumps singly. ailure to observe these instructions may change the operating point improper, resulting in trouble. Continuous Running Water Level
Tandem Operation -LH / LH-W- Tandem operation is an operation method that connects two pumps of the same model in series. This provides double pump head at the same flow rate in comparison with that of a single pump. The principle of tandem operation is the same as that with multistage pumps. The LH and LH-W series pumps adopt the center flange construction to align the discharge pipe with the cylindrical pump center axis.* Connecting the pumps in series with the tandem connector can provide higher pump head without affecting the advantage of the slim design. At construction sites, there are many cases where a higher pump head is required as construction work progresses. In such cases, the addition of a tandem pump may meet the required pump head, instead of using a new pump. * Available as an option for separately purchased LH. and LH2.W. Performance Curves 45 5 25 15 5 < LH. > < LH2.W > < LH25.5W > 9 7 1 1.2.4..8 1. 1.2.2.4..1.2..4.5. 45 9 1 5 25 15 5 7 Tandem 1 Tandem.2.4..8 1. 1.2.2.4..1.2..4.5. Discharge Bore mm Model Motor Output LH. LH2.W LH25.5W LH11W LH22W LH4W 5.5 11 22 * 1 available upon request * 2 Weights excluding cable Starting Method D.O.L. D.O.L. LH2.W for Tandem Operation Max. Head in Tandem / 44 78 / 8 1 12 4 / 21 24 / 254 Max. Head w/o Intermediate Connetion Pipe m 97.5 121.5 12 19.5 Dimensions L x H 185 x 71 185 x 759 254 x 8 27 x 4 x 1255 5 x 1 Dry Weight * 2 54 59 9 125 5 89 Allowable Load on Eyebolts kw mm kg kg 2 4 9 9 Cable Length m 1 1 1 1 < LH11W > < LH22W > < LH4W > 2 1 1.2.4..8.2.4..8 1..2.4..8 1. 1.2 1.4 1 1 1 1 2 1 1 2 2 1 1 2 2 1 1 Tandem.2.4..8.2.4..8 1..2.4..8 1. 1.2 1.4 11 12
Specifications LH LH LH-W LH. LH422 LH4 LH15 LH19 LH22 LH7 LH45 LH75 LH9 LH1 LH87 LH845 LH855 LH875 LH89 LH81 LH2.W LH25.5W LH11W LH22W LH4W LH41W Discharge Bore mm Discharge Connection Threaded Hose Connector Threaded JIS kg/cm 2 lange JIS kg/cm 2 lange JIS kg/cm 2 lange Hose Connector JIS kg/cm 2 lange JIS kg/cm 2 lange Solids Passage mm 8.5 12 8 8.5 8 Impeller Semi-open Closed Closed Semi-open (Dual) Closed (Dual) Closed (Dual Back-to-back) PUMP Mouth Ring Labyrinth Ring 4 Stainless Steel 4 Stainless Steel Stainless Steel Casing Gray Cast Iron / Ductile Cast Iron Gray Cast Iron / Ductile Cast Iron Shaft Seal Dual Inside Mechanical Seal (with Oil Lifter) Silicon Carbide Dual Inside Mechanical Seal (with Oil Lifter) Silicon Carbide Shaft Sleeve Stainless Steel Stainless Steel Stainless Steel Galvanic Anode Aluminium Alloy Aluminium Alloy Zinc Aluminium Alloy Type Continuous-duty Rated, Dry-type Induction Motor Continuous-duty Rated, Dry-type Induction Motor Output kw 22 15 19 22 7 45 75 9 1 7 45 55 75 9 1 5.5 11 22 1 Phase Three-phase Three-phase Pole 2 2 Insulation B B B Starting Method D.O.L. D.O.L. D.O.L. MOTOR Motor Protector (built-in) Leakage Sensor (built-in) CTP MTP CTP MTP MTP CTP MTP Electrode Electrode Electrode Lubricant ml 9 7 9 Turbine Oil (ISO VG2) 7 2 7 Turbine Oil (ISO VG2) Shaft 4 Stainless Steel 4 Stainless Steel Cable m Chloroprene Rubber Chloroprene Rubber Dry Weight* kg 42 55 21 495 5 85 1 495 5 8 85 1 12 4 1 4 24 127 * Dry weight excluding cable 1 14
www.tsurumi-global.com We reserve the right to change the specifications and designs for improvement without prior notice. Your Dealer Printed in Japan CAT. IB-A HB--C-S