CONTROL CENTRE FOR CENTRALISED LUBRICATION SYSTEM WITH PROGRESSIVE FEEDER AND SPRAY NOZZLES CCL Alpha Spray

Similar documents
CONTROL CENTRE FOR CENTRALISED LUBRICATION SYSTEM WITH PROGRESSIVE FEEDER CCL Alpha

IF-105 user interface (Original operating and maintenance instructions)

TECHNICAL DATA SHEET WORKING SPECIFICATION. Mains Power Supply: Wall Mounting. Online Connectivity. Operating Voltage. Data Feedback.

Control of the system, MLP RO pump station

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Step-by-step interpretation of 10-day electronic temperature monitoring devices for international vaccine shipments

PC15CP PUMP CONTROLLER

Installation and Operating Instructions

Original operating instructions Safety switch with guard locking AC901S AC902S

APPENDIX: APPLICATIONS

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

Operation Manual. Programmable Logic Controller

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

REACH-IN SAFETEMP (-AAC)

ELECTRICAL PUMP: PUMP MULTIPORT

Generator Paralleling Controller, GPC-3 Hydro Start and stop sequences, water level control

Operations Manual TS400. Test Station for G450/G460 Gas Detector

IWT 4000 Series Water Ingress Alarm System Installation Operation & Maintenance Instruction Manual

DOCUMENTATION IPS640

DOCUMENTATION IPS640

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

Movement controller comfort, Flush-mounted (Up) xx, xx

Centro-Matic Automated Lubrication Systems System Controls

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Applications and Examples

Room panel. for ecomax800 R or T regulators. OPERATION AND MAINTENANCE MANUAL ISSUE: 1.3 APPLICABLE TO SOFTWARE: v , v , v08.21.

Synco 900 Operating instructions

Synco 900 Operating Instructions. Edition 1.0 Controller series 1 CE1B2707en Building Technologies HVAC Products

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System

Residential Steam Humidifier

Operator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314)

11,1 30. Ordering data

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

Engineers manual. Pass Through machines P500 P500 A P500 AS P500 A WS P500 AS WS. A- AirBreak WS Water Softener. AS Dual Rinse Element

"VIP 2" ADVANCED LUBRICATION CONTROLLER

1 Opening the IPS WebViewer Activating or Deactivating the Detection Selecting a Profile Text Overlays...

OPERATING and SERVICE GUIDE USA - Coin in / Ticket out Feature.

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

LTP50 TABLET PRESS USER MANUAL

Synco living Operating Instructions. Edition 3.0 Controller series C CE1B2707en Building Technologies

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

CA5000 Liquid CO 2 Freezer Backup System

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

NO. F ISSUED: JUN. 15, 2009 REVISED: HOSHIZAKI MODULAR CRESCENT CUBER KMD-201AA KMD-201AWA MODEL SERVICE MANUAL

User manual for reversible heat pump

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1

DEMA 832 LAUNDRY MASTER TM INSTALLATION INSTRUCTIONS

12:20 17/FEB/03 R1 Packs Infotel Ltd *NO ALARMS ACTIVE* Press M for Menu. MENU OPTIONS *********************** >Change Roster< Y=Yes N=Nxt Esc=Exit

PONY 2/4 User Guide 2017

Monitored Pneumatic Valves On Series Ported Manifold

Engineers manual. Under counter machines

Door Release Power Supply

WHIRLPOOL ADP 8688 A PC 6S WH

Please read this manual before using the machine. Please keep this manual within easy reach for quick reference.

CSP-204 CSP-208 CSP-104 CSP-108

Oxygen & Carbon Dioxide Analyser. Model 1737 Operators Manual

½ Monitored Pneumatic Valves On Series Ported Manifold

TECHNICAL CATALOGUE GAS LEAK DETECTOR AND SOLENOID SAFETY VALVES

Refrigerated air dryers

Z-1500II and Z-3000II USER MANUAL Z-1500II und Z-3000II BEDIENUNGSANLEITUNG Mode D Emploi des Z-1500II et Z-3000II Machines à Fumée

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Reliability is a beautiful thing TM CUBELET ICE DISPENSER DCM-500BAF DCM-500BWF DCM-750BAF DCM-750BWF INSTRUCTION MANUAL

PCS 2000 CONTROLLER USER GUIDE PCS 2000 CONTROLLER. Contents

FLAKER/DCM SEQUENCE OF OPERATION

Installation and operating instructions KEMPER KHS-Timer-Set Figure and Figure

SWEBO Bioenergy Manual pellet burner PB20 Rev no. Date Page PBM1: (36) Installation and maintenance instructions

TEMPERATURE CONTROLLER (STANDARD MODEL)

User s Manual DCU 305 R3 DCU 305 R3 LT. Diesel Engine Control Unit. Auto-Maskin

SCAN200E USER S MANUAL

CORROSIONBOX 1000 litres salt spray chamber enhanced model

ALARM SYSTEM USER S MANUAL Rev

Alarm Switchgear AS1-M

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ridley Terminals Canada. Site HMI Station. In Central Office. Prepared by: Wayne Leung Controls Specialist. QCA Systems Limited

Air-Conditioners. Indoor unit PSA-RP KA OPERATION MANUAL. English

OPERATION & MAINTENANCE MANUAL AC880

DEIF A/S. Operator s Manual. Multi-line 2/version 2-GS E (UK) SW version 2.4X.X. Display readings. Push-button functions.

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

UV - Monitor UVT 16. Use. Description

SERVICE-MANUAL INDUCTION COOKER BASE-LINE/FAJITA HEATER SH/BA 3500 FH

Note: The buttons on the wireless key fob are sensitive. Kindly handle the fobs with care to avoid false alarms.

Technical Review. Remote Condenser Cuber. Enhanced Refrigeration and Water Systems. CM 3 Technology. of a. with. using. models included are:

Garb-el Free Standing Models

DCS2000 DEMENTIA CARE SYSTEM USER GUIDE. For Software Version 1.2 1

Ultrasonic Nozzle Cleaner Evaluation July

With the world-renowned SIGMA PROFILE

U 5003 Drying Unit. Operation manual for cabinets with the U 5003 Drying Unit

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Generator Control Unit, GCU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Transcription:

I2130-E-05.04 CONTROL CENTRE FOR CENTRALISED LUBRICATION SYSTEM WITH PROGRESSIVE FEEDER AND SPRAY NOZZLES CCL Alpha Spray Model No. 907044 USER S MANUAL CONTENTS 1. DESCRIPTION Page 2 2. DATA Page 2 3. HANDLING Page 3 4. ELECTRIC DIAGRAM Page 7 5. CE Certificate Annex 1 1

1. DESCRIPTION Control centre CCL Alpha is designed for controlling and monitoring of centralised lubrication systems equipped with a primary progressive feeder with cycle switch. The control centre also control an air-valve for the grease spray nozzles.. FUNCTIONS - Adjustable interval time and number of feeder cycles. - Extra lubrication - Machine-interlocking control. - Output for operating indication. - Output for alarm signal (activated at too low a flow rate, low level of lubricant reservoir or too low air pressure. DEFINITIONS Lubrication interval Cycle Time between two starts of the lubrication pump. Complete operating cycle of the progressive feeder connected. 2. DATA Protection class IP 65 Dimensions 230x300x145 (WxHxD) Weight 3,5 kg. Supply voltage 230 V AC Power consumption 30 W Outputs: Pump, solenoid valve 230V AC max 25W. Operating indicator 24V DC max 5W. Alarm Potential-free contact max.250v AC, 30V DC Max 1A Inputs: 24V DC Adjustment range time 1 32 767 minutes Extra spray time 1 32 767 seconds 1 32 767 2

3. HANDLING SETTINGS The time between two starts of the lubrication pump is called the interval and is adjustable. The lubrication system must comprise a progressive feeder with cycle switch. The number of cycles at each pump start can be set. The pump is being stopped after the number of cycles set have been performed. U-link the terminals 111 and 112 to enter the setting mode. 360 min 10 Place the cursor at the setting to be changed with the up/down arrow. Change setting by pressing +or -. Confirm the new setting by pressing OK. Remove the u-link between terminal 111 and 112. Example: A bearing requires 1 cm³ of lubricant every 6th hour. The bearing is connected to one outlet of the progressive feeder which feeds 0.1 cm³ per outlet and cycle. The required number of cycles is accordingly 10 every 6th hour = 360 minutes (.) Setting the spray time: The spray time is the extra time after that the pump has stopped when the spray valve is still open. That time is used to avoid after drip from the nozzle. U-link the terminals 111 and 112 to enter the setting mode. Spray 20 sec Change to the Spray setting with the right arrow. Change setting by pressing +or -. Confirm the new setting by pressing OK. Remove the u-link between terminal 111 and 112. 3

NORMAL OPERATION In normal operation mode the display shows the time elapsed of the interval time since the last start. 60 min 0 In this example 60 minutes has elapsed of the interval time. During the pumping phase the display shows the number of cycles performed and the pumping time from the start. 2 min 5 In this example the pump has been operating 2 minutes and 5 cycles have been performed. EXTRA LUBRICATION An extra lubrication may be activated at any time. 360 min 10 Increase the interval by pressing + until it equals the entered time and press OK. 4

MACHINE INTERLOCKING. The control centre can be controlled by the lubricated machine, so called, machine interlocking. Machine stop When the contact for machine interlocking is being closed (the lubricated machine is stopped) the lubrication phase in progress, if any, is stopped as well as the time counting. At restart of the machine the lubrication phase and the time counting resumes. OPERATING INDICATOR The operating indication output (24V DC) has the same functions as the lamp in the front of the control centre. No voltage: Control centre is switched off or machine-interlocked. Alternating voltage 0-24V: Alarm Voltage on Control centre is operating. ALARMS If the entered number of cycles have not been performed at the end of the interval time, a low flow alarm will be activated. LOW FLOW The system stops lubricating and the alarm contact closes. To acknowledge the alarm, press ESC - a new lubrication phase is then started. If the alarm level switch in the lubricant reservoir is triggered, a low level alarm is activated. LOW LEVEL The system stops lubricating and the alarm contact closes. The alarm is deactivated when the reservoir has been replenished. 5

If the air pressure switch is open (too low pressure), a low air pressure alarm is activated. LOW AIR PRESSURE The system stops lubricating and the alarm contact closes. The alarm is deactivated when the air pressure is normal again. 6