Bench Top Cooling Tower H893

Similar documents
Air & Water Heat Pump R832

Mechanical Heat Pump R515

A660 Air Conditioning Laboratory Unit

P.A. Hilton Ltd. Figure 2: HC655A Optional Computer Linking Upgrade

Refrigeration Cycle Demonstration Unit R633

Refrigeration Cycle Demonstration Unit R634

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Vapour Jet Refrigerator / Heat Pump R853

Ventilation Trainer B500

Heat Transfer Service Unit H112

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Sunrise the beginning of a brand new day

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

armfield COMPUTER CONTROLLED HEAT EXCHANGER SERVICE MODULE HT30XC series issue 2

CRYSTALLISATION UNIT UOP14-MKII

LAUDA Additional devices Immersion coolers, through-flow coolers, circulation heat exchangers

Microtherm Heat Stress WBGT

COMPUTER-CONTROLLED HEAT TRANSFER TEACHING EQUIPMENT HT10XC NEW ACCESSORY HT20 CONDUCTIVITY OF LIQUIDS AND GASES

Experiment 12 Shell and Tube Heat Exchanger. Aim of this Experiment

TC WATER COOLING TOWER UNIT

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Study on the Effect of Blade Angle on the Performance of a Small Cooling Tower

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

WeatherLink for Alarm Output Addendum

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

LAB EQUIPMENT DETAILS

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Eastern Mediterranean University Department of Mechanical Engineering Laboratory Handout

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

The latest development in material characterization and polymer processing. Rheometer Services Inc.

Advanced Test Equipment Rentals ATEC (2832)

Concise catalogue Water-Industry

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Introduction to Refrigeration Unit TIR

Computer Controlled Recycle Loops Unit TRLC

SiteSentinel itouch Console

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

HPLC Column Ovens and Temperature Controllers

Tel.: 016/ Fax: 016/

PART 3 Refrigeration & Air Condition System

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Determination of the enthalpy of vaporization of liquids

Specification for On-Line UPS Battery Monitoring and Data Management System

Chromatographic Air circulated Refrigerator, two-door TC 603

Heating Ventilation and Air Conditioning Laboratory

Temperature Data Logging

AFA 500 FUME HOOD ALARMS

Laboratory Refrigerator/Deep Freezer TC 802

ENSC 388: Engineering Thermodynamics and Heat Transfer

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Chromatographic Air circulated Refrigerator, two-door TC 603

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

LABCONCO 1000 GUARDIAN DIGITAL MONITOR Operating and Instruction Manual

Chapter 14, Problem 27.

WL 110 Series. Heat Exchanger with Supply Unit EQUIPMENT FOR ENGINEERING EDUCATION

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Week 4. Gas-vapor mixtures Air conditioning processes. ME 300 Thermodynamics II 1

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

Siemens Building Technologies Landis & Staefa Division. for central units OCI600 / OCI611 / OZW10 / OZW111 / OZW30 / OCI55

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

Performance evaluation of an innovative fan-coil unit: Low-temperature differential variable air volume FCU

SCA 620C AIR COOLED SCREW CHILLER

Internet. Climate rating definitions. Customer service.

PolyScience. Circulators. Constant Temperature Equipment. Remarkably Responsive TM

Optimizing Electric Humidifier Operation with an Air Side Economizer

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

Performance Analysis of a Solid Desiccant Air Dehumidifier

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Evaporative Cooling. HEVAC Association. Humidity Group. an alternative and supplement to mechanical cooling

Simple Compression Refrigeration Circuit Unit TSCR

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment

TEMPERATURE AND HUMIDITY TEST CHAMBER LTHC-A1 SERIES

Datalogging as standard

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Corrosion Testing Instruments Model 618

COMPLETELY AUTOMATED HYDROLYSIS

AIR CONDITIONER PERFORMANCE RATING

The Refrigeration Cycle

Controller Specification Sheet

Electric radiator test

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

Exercise 2-4. Heat Exchangers (Optional Exercise) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Description of a brazed plate heat exchanger DISCUSSION

Updated: September 12, 2018 DIVISION INTEGRATED AUTOMATION. INTEGRATED AUTOMATION Page 1 of INTEGRATED AUTOMATION

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

VM-3000 Mercury Vapor Monitor

SUPREMATouch. Modular Fire & Gas Detection System

The Refrigeration Cycle

Transcription:

Bench Top Cooling Tower H893 Figure 1: H893 Shown with Column B (fitted) and Optional Column E Demonstrates all processes found in a full scale forced draught cooling tower Rapid stabilisation allows experimental work to immediately upon switching on Columns with varying packing densities available as optional extras. Optional Packing Characteristics Column also available Can be linked to External Loads of up to 1.5 kw including the R514 Mechanical Heat Pump or R832 Air and Water Heat Pump via an intermediate reservoir system Two year warranty Page 1

Introduction The Hilton Bench Top Cooling Tower has been designed to meet the demand for a compact cooling tower which clearly demonstrates all the processes found in a full size forced draught cooling tower and behaves in a representative manner. Supplied with standard column B, a number of additional columns are available as optional extras to cope with a wide variety of educational needs in the study of Thermodynamics, Heat and Mass Transfer, Refrigeration and Air Conditioning. The unit will be of particular interest to those studying: Building Services Chemical Engineering Energy Transfer and Conservation Mechanical Engineering Mining Engineering Plant and Process Engineering Experimental Capabilities Basic Unit with Column B Observation of water flow pattern and distribution. Measurement of all end states, and rates of flow of water, air and make-up. Plotting of end states on a psychrometric chart and the application of the steady flow equation to draw up energy balances. Investigation of performance at, (a) A range of process cooling loads. (b) A range of inlet temperatures. ADDITIONAL COLUMNS (Optional) Columns A and/or C Investigation of effect of the packing surface area/volume ratio on, (a) Cooled water temperature approach to wet bulb temperature at inlet to column. (b) Pressure drop across packing Column D (Empty Column) Investigation of performance of locally designed and manufactured packing (student projects). Column E (Packing Characteristics Column) Enables air and water properties to be measured at three stations within the packing. Provides data for the construction of enthalpy driving force diagrams. Determination of the Characteristics Equation for the packing. Description BASIC UNIT Water Circuit Warm water is pumped from the load tank through the control valve and water flow meter to the column cap where its temperature is measured. The water is uniformly distributed over the top packing deck and, as it spreads over the plates, a large thin film of water is exposed to the air stream. During its downward passage through the packing, the water is cooled, largely by the evaporation of a small portion of the total flow. The cooled water falls from the lowest packing deck into the basin, from where it flows past a thermocouple and into the load tank where it is re-heated for re-circulation. Page 2

Due to evaporation, the level of the water in the load tank slowly falls. This causes the float operated needle valve to open and transfer water from the make-up tank into the load tank. Under steady conditions, the rate at which the water leaves the make-up tank is equal to the rate of evaporation, plus any small airborne droplets in the air discharge Air Circuit Air from the atmosphere, pre-heated by external means if desired, enters the fan at a rate, which is controlled by the intake damper setting. The fan discharges into the distribution chamber and the air passes wet and dry bulb thermocouples before it enters the packed column. As the air stream flows through the packings, its moisture content increases and the water is cooled. On leaving the top of the column the air passes through the droplet arrester, which traps most of the entrained droplets and returns them to the packings. The air is then discharged to the atmosphere via the air measuring orifice and further wet and dry bulb thermocouples. All of the foregoing may be observed through the transparent structure of the column. All temperatures are indicated by a digital temperature indicator and thermocouple selector switch. OPTIONAL ADDITIONAL COLUMNS Columns A and C Column B supplied with the basic unit may be quickly replaced by either column A or C. All columns have the same external dimensions, but contain different quantities of packing, so that the effect of packing area upon the performance of the cooling tower may be investigated. Column D (Empty Column) This column has no internal fittings or packing and is available so that students can make and investigate the performance of their own packing and water distribution system. Column E (Packing Characteristics Column) This is available for those who wish to investigate the way in which the air and water properties change as they pass in opposite directions through the column. From this information, enthalpy driving force diagrams may be constructed and the packing characteristics equation determined. Column E is similar to column C, but is about 300mm higher. The packing is arranged in four blocks with intermediate spaces in which the water and air dry and wet bulb thermometers are measured by thermocouple sensors. These temperatures are displayed by digital indicator mounted on the side of the column. TYPICAL OBSERVATIONS & RESULTING BALANCES BASIC UNIT: Page 3

Specification General Bench top, forced draught cooling tower with integral load and make-up tanks, circulating pump, complete with all necessary instruments. Optional additional columns available. Detailed Basic unit: Constructed in G.R.P. and housing load tank with 0.5 and 1.0 kw heaters and float level control, make-up tank, bronze circulating pump, air fan, electrical control panel with digital temperature indicator. Packed Column B : Constructed in transparent P.V.C. with eight decks of inclined laminated plastic packing, water distribution troughs and pressure tappings. Packing density 110m 2 per m 3. Cap: Transparent P.V.C. fitted with 80mm dia. Sharp edged orifice, droplet arrester and water distributor. Instrumentation: Digital Temperature indicator with channel selector switch for all wet bulb, dry bulb and water temperatures. Variable area water flowmeter and manometer for airflow. Additional Columns Column A: As column B but with a packing density of 77m 2 per m 3 Column C: As column B but with a packing density of 200m 2 per m 3 Column D: Empty Column Column E: (Packing Characteristics Column). Similar to column C but with packing arranged to allow measurement of air and water properties within column. Fitted with thermocouple sensors, selector switch and digital thermometer. Dimensions Base Columns Column Unit A, C & D E Height: 120cm 60cm 90cm Depth: 45cm 15cm 15cm Width: 75cm 15cm 25cm Optional Data Acquisition Upgrade An optional Data Acquisition Upgrade HC893A comprising of an electronic data logger, menu driven software and all necessary transducers, allows all relevant parameters to be simultaneously displayed and recorded on a suitable PC. The software allows review and printing of data and transfer to spreadsheets for complex analysis and calculation. Accessories and Spares Unit supplied with: One experimental operating and maintenance manual in English, Spanish, French. Accessories and spares for 2 years normal operation. List available on request. Services Required Electrical: A: Or: 1.6 kw. 220-240 Volts, Single Phase 50Hz (With earth/ground). B: 1.6 kw.110-120 Volts, Single Phase, 60Hz (With earth/ground). Water: Demineralised or distilled Approx. 2 kg / hour Ordering Information Order as: H893 Bench Top Cooling Tower Optional Extra Columns: H893A Column A H893C Column C H893D Column D H893E Packing Characteristics Column HC893A Data Acquisition Upgrade Electrical Specification Either: A: 220/240 Volts, Single Phase 50Hz (With earth/ground). B: 110-120 Volts, Single Phase 60Hz (With earth/ground). Language Either: English, Spanish, French. Shipping Specifications (Basic Unit with Column B) (Estimated) Net Weight: 56 kg. (approx.) Gross Weight: 96 kg. (approx.) Packing Case Dimensions: 112 x 82 x 73 cm (approx.) Packing Case Volume: 0.670m 3 (approx.) Also Available On Request Further detailed specification. Additional copies of instruction manual. Recommended list of spares for 5 years operation. Suitable chiller details. Page 4

Optional Data Acquisition Upgrade HC893A Hardware details The optional Data Acquisition Upgrade HC893A consists of an externally located 35 channel Hilton Data logger (D102), together with dedicated software that will operate in the Windows TM environment. The combined software and hardware package allows computer monitoring of all relevant system temperatures, air pressures, water flow rate and electrical input power to the heat load. A duplex set of thermocouples provide the system temperatures, a pressure transducer and water flow transducer connect to factory fitted internal couplings. The additional transducers allow the unit to be operated either with the computer or in the standard manual mode. As all transducer coupling points are factory fitted the Data Acquisition Upgrade HC893A may be purchased and installed at any time. Software Details The pre-configured menu driven Software supplied with the Data Acquisition Upgrade HC893A allows all recommended experiments detailed in the Bench Top Cooling Tower H893 manual to be carried out with the aid of computerised data acquisition and on screen data presentation. This enhances student interest and speeds comprehension of the principles being demonstrated. Students may be presented with numeric data or graphic data plotted against time. Additional Data Logging Facility Supplied As Standard The Hilton Data Logger (D102) is an industrially proven 35 channel interface with 15 thermocouple/differential voltage inputs (±80mv dc), 8 single ended dc voltage inputs (±8v), 8 logic or frequency inputs, 3 ac current inputs one mains voltage input and 8 current sinking output channels. In addition there are on board 12v dc, ±5V dc and ±15v dc power supplies for most commercially available transducers. The pre-configured Hilton Data Logging software, supplied as standard with the HC893A package, allows the D102 to be disconnected from the H893 transducers and used together with most standard transducers as a stand alone computer data logger and controller for the monitoring and control of existing laboratory equipment. This further expands the student project capabilities of the HC893A package from teaching and demonstration into the field of research and postgraduate study. Computer Hardware Requirements The menu driven Software supplied with the Data Acquisition Upgrade HC893A will operate on an IBM or IBM compatible PC having at least 32 Mb ram, VGA graphics, 1Gb hard drive and an available RS232 serial port. The software is Windows 95/98, 2000 and XP compatible. Order as: Data Acquisition Upgrade HC893A P A Hilton Ltd. Horsebridge Mill, King s Somborne, Stockbridge, Hampshire, SO20 6PX, England. Telephone: National (01794) 388382 International +44 1794 388382 Fax: (01794) 388129 E-mail sales@p-a-hilton.co.uk Data may be printed, stored on disc for later analysis and transferred in ASCII form to most spreadsheets for further analysis and projects. Page 5