CONNECTION SYSTEMS TRANSIT APPLICATIONS

Similar documents
PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Flexible Power Cable DLO

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

A Look at General Cable s GenFree II Product Line

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Nuclear Power Plant LSZH Cable Overview

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Catalogue Power Cables

HEAT SHRINK CABLE ACCESSORIES: A 40 YEARS PROVEN TECHNOLOGY FOR APPLICATIONS IN HARSH ENVIRONMENTS

SECTION ELECTRICAL GENERAL PROVISIONS

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Class 1E Cable Qualification to the Latest IEEE Standards

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

PERFORMANCE POLYMER SOLUTIONS

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

High Performance LSZH Fire Resistant Cable

Tratos Railway Cables

DNVGL-CP-0401 Edition February 2016

Photovoltaic Cables EN H1Z2Z2-K

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

MILITARY/AEROSPACE MARKETS INNOVATIVE SOLUTIONS GUIDE

Catalogue. Instrumentation & Control Cables

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves

CATALOG LIQUID-TUFF FLEXIBLE LIQUIDTIGHT CONDUIT CATALOG. Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit A PART OF

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Flame Retardant Overall Screened Instrumentation Cables (multicore)

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

Comtran Cable. Hub-LINK Cables for Transit Applications

OIL & GAS INDUSTRY OTHER INDUSTRIES

Catalogue Telecommunication Cables INTRODUCCIÓN

Caledonian Flame Retardant Coaxial Cables

DNVGL-CP-0399 Edition March 2016

PRODUCT CATALOGUE Norröna

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

The DEF-System by BRUGG. The Best Way to defeat the problem of DEF heat Installation Instructions

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

Havells Fire Survival Cables

VITALink. FAQs I. GENERAL QUESTIONS

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

LAPP GROUP NORTH AMERICA CABLE ATTRIBUTES QUICK GUIDE

The Quality Connection. BETAflam Fire Resistant Safety Cables

FIRE RESISTANT CABLES

Caledonian Fire resistant Coaxial Cables

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

TABLE OF CONTENTS. Section Title Page 1.0 SUMMARY TEST SPECIMEN Materials and Construction TEST PROGRAM 4

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Section 5: Medium Voltage Joints - up to 42kV

Wires, Cables, Cords and Adhesive Tapes

Brand Portable Power Cord & Control Cable Solutions

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

BS /1000V XLPE Insulation LSZH Sheath Cables

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

Power Control Cable Iec

RENEWABLE ENERGY. Durable solutions for maximum efficiency and the promise of reliability. ENERGY PIONEERS IN POWER SOLUTIONS

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

(800) 292- omnicable.com CABLE ACCESSORIES GUIDE

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

ASSOCIATIONS AND REFERENCE STANDARDS

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

Sensor and transducer cables

fire resistant cables

LOW VOLTAGE SPLICES & TAPS

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

C Electrical Connection Kit

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

Wire and Cable The Industry Standard for Rugged, Reliable Performance

Electrical Safety Requirements

Lloyd s Register Type Approval System Test Specification Number 3

Caledonian fire Resistant signal & Data cables

5. Identification products.

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

APPENDIX C REGULATORY AGENCIES AND INDUSTRY STANDARDS 1.0 APPLICABLE GOVERNMENT CODES AND REGULATIONS

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

Adhesives Selection Guide

Transcription:

CNNECTIN SYSTEMS TRANSIT APPLICATINS

Ensure electrical and mechanical reliability with the engineered products and solutions of Shawcor s Connection Systems group INTEGRITY IS BEHIND EVERYTHING WE D. By connecting, insulating, sealing and protecting the valuable assets and equipment systems of your operation, we assure the reliability of your electrical connectivity for a wide range of industrial processes over the lifespan of your installation. That reliability is what solves our customers toughest challenges, and it starts with a specialization in application engineering. But one thing remains constant: We put integrity first. It s the foundation on which we were built. And it s not just in how we operate it s behind every product we engineer. It s part of every new project we take on. And it s the promise that we give our customers. They ve trusted in us for 85 years to engineer and develop, build and innovate but namely, to protect the assets that they rely on in the industries that keep our world running. ENGINEERING CAPABILITIES Shawcor is committed to leading the industry with innovative solutions that are proven, dependable and tested to the highest standards and precisely manufactured to your specifications. Many customers rely on our unique in-house design capability and expertise to tackle projects of all scopes and sizes. We provide comprehensive services, advanced in-house materials and product research as well as product development and pre-qualification testing. We offer customers much more than a catalogue of products. We provide the technical leadership and service responsiveness needed to meet all of your project deadlines as well as your performance requirements to produce a dependable and superior product. TRANSIT PRDUCT FFERING Shawcor is a leading supplier of innovative connection systems in the transit market. We offer solutions that cover a variety of products that meet the needs of our customers in this challenging market. ur product offerings cover: Signalling Cable Control Cable Power Cable Heat Shrink Cable Accessories Cold Shrink Cable Accessories ur products are designed in adherence to industry specific standards; AREMA, CP-100, CSA, UL, ICEA, IEEE, ANSI and NFPA providing superior quality and safety. Safety is of the utmost importance to Shawcor and our products are designed with that in mind. With superior materials for fire resistance and/or Low Smoke Zero Halogen performance that creates a safe environment throughout the service life of the product.

perational protection through reliable connections and manufacture custom cables, whether it is built to an engineering specification or a national specification such as CSA, AREMA or CP-100. Below is a summary of the major projects that we have worked on in this time period. Project List Toronto Transit Commission (TTC) Spadina Extension Toronto Transit Commission ATC project Waterloo LRT Edmonton LRT SHAWCR HAS SUPPLIED NEARLY 2 MILLIN METERS F TRANSPRTATIN CABLE T THE NRTH AMERICAN TRANSPRT INDUSTRY ver the past 10 years Shawcor has supplied ShawFlex cable for several major North American transportation projects. We have the ability to design, develop, qualify Calgary LRT STM (Montreal) Vancouver RAV & Skytrain Vancouver Evergreen Line PATC Rail Project SIGNAL AND CNTRL CABLES 22 AWG to 2000 kcmil, 300 V - 5000 V Transmission of digital and analog signals for train management and control. Wide range of choices covering AREMA, Canadian Pacific Railway and CSA requirements. Hazardous Locations (HL), CSA C22.2 No. 1 74 Extreme Low Acid Gas Emission (AG14) Excellent in fire retardant and low smoke, CSA FT4 - ST1, IEEE1202, UL1685 Super ozone resistance and sun light resistance can withstand prolonged outdoor exposure AREMA Part 10.3.16 ICEA S-73-532 AREMA Part 10.3.17 ICEA S-95-658 CSA C22.2 No. 38 UL44 CSA C22.2 No. 239 UL1277 CSA C22.2 No. 131 UL13 CSA C22.2 No. 174 NFPA-130 Canadian Pacific Railway, CP-100 Soft/Annealed, bare/tinned copper in accordance with ASTM B3/B33/B8, Class B, C or higher class stranding Insulation: (vary by construction) Cross-Linked Polyethylene (XLPE), RW 90/XHHW-2 Rated Insulation High Performance Linear Low Density Polyethylene (LLDPE) Ethylene-Propylene Rubber (EPR), RHW-2, AREMA Part 10.3.19 Cross-Linked Polyolefin Low Smoke, Zero Halogen (XLP LSZH) (insulated conductor only) Jacket: (vary by construction) Low Smoke Zero Halogen Thermoplastic Polyethylene (TP LSZH), AREMA Part 10.3.13 High Performance Linear Low Density Polyethylene (LLDPE) AREMA 10.3.21 Flame retardant, Low Smoke Zero Halogen Cross- Linked Polyolefin (LSZH XLP), AREMA Part 10.3.13 Chlorinated Polyethylene (XL CPE)

TRACTIN PWER CABLE 1/0 AWG to 2000 kcmil / 600 V - 2000 V For using as positive power delivery, negative return, and bonding cables in transit traction power systems. High performance on oil, moisture, abrasion, sunlight resistant and crush and impact in harsh environment, typically for traction power circuit. Superior low smoke and flame retardant performance: CSA FT4-ST1, IEEE 1202, UL1685 Jacket compound meets halogen content and smoke generation requirements of ICEA S-95-658, Table 4-2 Excellent in Cold bend: -40 C Super ozone resistance can withstand prolonged outdoor exposure CSA C22.2 No.38, Type RW90 UL 44, Type RHW-2 ICEA S-95-686 NFPA-130 Soft/Annealed, bare/tinned copper in accordance with ASTM B3/B33/B8, Class B, C, G or higher class stranding Insulation: Jacket: EPR, Rated 90 C wet or dry with continuous operation, 600 V - 2000 V Flame retardant, Low Smoke Zero Halogen Cross- Linked Polyolefin (LSZH XLP) CABLES FR STATIN, CNTRL & PWER 22 AWG to 2000 kcmil, 300 V - 5000 V Power distribution for lighting installations, power receptacles and battery backups in the general station or anywhere that there is a concern of damage caused by smoke to instruments in your installation. Low Smoke, limited toxic and corrosive gases emission compound provides a safe environment for personnel and equipment during a fire. Sunlight - and weather-resistant Direct burial rated Meets cold bend test at -40 C Bare/Tinned Copper Conductor ASTM B8/B33 Class B Stranding Insulation: (vary by construction) Cross-Linked Polyethylene (XLPE), RW90/XHHW-2 Rated Ethylene-Propylene Rubber (EPR), RWU90/RHW-2 Low Smoke, Zero Halogen Cross-Linked Polyolefin (LSZH XLP), RW90 (insulated conductor only) Jacket: (vary by construction) Low Smoke Zero Halogen Thermoplastic Polyethylene (TP LSZH) Flame retardant LAG PVC Chlorinated Polyethylene (CPE) CSA C22.2 No. 38 IEEE1202 CSA C22.2 No. 230 UL1685 CSA C22.2 No. 239 ICEA S-73-532 CSA C22.2 No. 131 ICEA S-95-686 CSA C22.2 No. 174 UL44 CSA FT4 - ST1 UL1277 NFPA 130 UL13

Shawcor.com/Connection Systems GRUNDING CNDUCTR 8 AWG to 750 kcmil / 600 V - 2000 V Grounding metallic parts to ensure the integrity of electrical system and safety of people. Solid green or green with dual yellow SAFE-T- STRIPES which resist installation wear and provide safe identification Meets CEC 22.1-15 Section 2-130 flame spread requirements Easily installed for equipment bonding/grounding Suitable for use in cable trays (as per the CEC) Vertical Tray Flame Test Rated -40 C cold bend/impact rated UV sunlight resistant SUN RES Bare/Tinned Copper Conductor ASTM B8/B33 Class B Stranding Insulation: Jacket: UV Resistant Cross-Linked Polyethylene (XLPE), RW90 Rated Insulation FR PVC LAG outer green jacket CSA C22.2 No. 230 XLPE (RW90 rated) CSA C22.2 No. 38 90 C wet/dry CSA FT4 Direct burial rated UL 1685 ACCESSRIES FR LV/MV VLTAGE CABLES Heat Shrink & Cold Shrink, 600 V - 35 kv Accessories for power networks, terminations and joints for low and medium voltage cables, such as the application in transformers and switch gear equipment. 5-35 kv MV Cold Shrink Terminations TITAN Z All-in-one design incorporating stress control and sealing mastics Quick, consistent and easy to install. ffering fewest number of installation steps, saving time Patent pending stress control system based on Microvaristor (Zn) technology that delivers exceptional discharge and impulse performance Excellent UV resistance and hydrophobic characteristics Tested to latest requirements of IEEE-48-2009, Class 1 Tested at an independent accredited laboratory to IS/IEC 17025:2005 standards 600 V - 1000 V Heat Shrink Products CFM: Medium Wall Cross-Linked Polyolefin Tubing, 3:1 Shrink Ratio CFW: Heavy Wall Cross-Linked Polyolefin Tubing, for electrical insulation and mechanical protection of cable joints and terminations FCFW: Heavy Wall Cross-Linked Polyolefin Tubing, for protecting electrical splices and terminations where maximum flame retardancy and exceptional installation and sealing characteristics are required 600 V - 1000 V Cold Shrink Products CSS: Cold applied splice sealing products offer excellent insulation and moisture proof sealing for inline cable connector systems or elbow to cable jacket applications Zero Halogen Heat Shrink Tubing CZT 200: Thin Wall Halogen Free XLPE tubing, low smoke generation for excellent fire safety characteristics, flame retardance. 600 V Professional Grade Vinyl Electrical Tape CET: All weather, professional grade pressure sensitive vinyl tape, 7 mil thickness, cold and weather resistant, flame retardant

25 Bethridge Road Toronto, ntario M9W 1M7 Canada 1 800 668 4842 info@shawflex.com Shawcor.com/Connection-Systems All information contained in this brochure is believed to be reliable. We advise however that customers should separately evaluate the suitability of our products for their particular application. Shawcor gives no guarantees in respect to accuracy or sufficiency of the information presented and disclaim any liability regarding its use. ur responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect, or consequential damage or damages arising from the sale, resale, transfer, use or misuse of the product. Subject to modification.