CERTIFICATE OF FIRE APPROVAL

Similar documents
CERTIFICATE OF FIRE APPROVAL

CERTIFICATE OF FIRE APPROVAL

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

RESOLUTION MSC.217(82) (adopted on 8 December 2006) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

RESOLUTION MSC.44(65) (adopted on 11 May 1995) STANDARDS FOR FIXED SPRINKLER SYSTEMS FOR HIGH SPEED CRAFT

CERTIFICATE OF FIRE APPROVAL

RESOLUTION MSC.265(84) (adopted on 9 May 2008) AMENDMENTS TO THE REVISED GUIDELINES FOR APPROVAL OF SPRINKLER SYSTEMS EQUIVALENT TO THAT REFERRED TO

RESOLUTION MSC.339(91) (adopted on 30 November 2012) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE)

USCG-EU MRA EC TYPE EXAMINATION (MODULE B) CERTIFICATE SAMPLE

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

OFFSHORE SUPPORT VESSELS 2014

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

RESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

RESOLUTION MSC.98(73) (adopted on 5 December 2000) ADOPTION OF THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

MORE THAN JUST FIRE PROTECTION

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

MORE THAN JUST FIRE PROTECTION

IMO WORK PROGRAMME. Central control stations and safety centres on passenger ships. Submitted by Argentina and ICCL

Requirements for ships carrying hydrogen and compressed natural gas vehicles

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES

USCG-EU MRA EC TYPE EXAMINATION (MODULE B) CERTIFICATE

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

RESOLUTION MSC.101(73) (adopted on 5 December 2000) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR APPLICATION OF FIRE TEST PROCEDURES

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

ClassNK Technical Information No. TEC-0453 Attachment (1) to ClassNK Technical Information No. TEC-0453 Guidance on SOLAS Chapter II-2 as amended in 2

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

4, DG UV Test. EC-Type Examination (Module B) Certificate. A.1/3.11 a - "A" Class divisions, fire integrity

Guidance on the construction of CO 2 systems

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

Technical Information

IMO FP 53 Report. Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee. 16 th March, 2009

Attachment 1. to ClassNK Technical Information No.TEC-0764 Malta Maritime Authority Date Revised 28 August 2008 Page 1 of 10 This Administration Requi

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

EC TYPE EXAMINATION CERTIFICATE

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

MSC Guidelines for Automatic Sprinkler Systems

Only the Danish version is authentic Notice D II-2 N(2) 1 October 2002 CHAPTER II-2 N(2)

UNIFIED INTERPRETATIONS OF SOLAS CHAPTER II-2, THE FSS CODE, THE FTP CODE AND RELATED FIRE TEST PROCEDURES ***

RESOLUTION A.752(18) adopted on 4 November 1993 GUIDELINES FOR THE EVALUATION, TESTING AND APPLICATION OF LOW-LOCATION LIGHTING ON PASSENGER SHIPS

Foam Concentrates Test and Fire Test

RESOLUTION MSC.291(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CONVENTION FOR THE SAFETY OF LIFE AT SEA, 1974, AS

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

MOBILE OFFSHORE DRILLING UNITS 2012

IMO CCC1 Summary Report on the developments of the IGF Code

EU DECLARATION OF CONFORMITY (Doc) issued in accordance with the MARINE EQUIPMENT DIRECTIVE (MED) and EU/US MRA

Lloyd s Register Type Approval System Test Specification Number 3

ClassNK Technical Information No. TEC-0838 (iii) The dormant period, visual indication, first stage audible alarm, second stage remote audible alarm a

IMO LIST OF DOCUMENTS ISSUED IN CONNECTION WITH THE FORTY-SEVENTH SESSION OF THE SUB-COMMITTEE ON FIRE PROTECTION AGENDA FOR THE FORTY-SEVENTH SESSION

Void. Technical Information. Subject. Bulk Carrier Safety:Water Ingress Detection and Alarm System. No. TEC-0537 Date 3 July 2003

***** 2. Rev.1 is to be uniformly implemented by IACS Members from 1 July 2004.

C-01 FIRE DECKS AND BULKHEADS

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

IACS RESOLUTION CHANGES (GMO ) BEKİR SITKI TÜRKMEN

DRY CHEMICAL POWDER SYSTEM REQUIREMENTS TO COMPLY WITH THE LATEST IMO IGC CODE AND EUROPEAN COUNCIL CLARIFICATIONS

RESOLUTION MSC.188(79) (adopted on 3 December 2004) PERFORMANCE STANDARDS FOR WATER LEVEL DETECTORS ON BULK CARRIERS AND SINGLE HOLD CARGO SHIPS

Order on fixed CO 2 fire-extinguishing systems 1

RESOLUTION MSC.145(77) (adopted on 5 June 2003) PERFORMANCE STANDARDS FOR WATER LEVEL DETECTORS ON BULK CARRIERS

IMO DEVELOPMENT OF MODEL PROCEDURE FOR EXECUTING SHIPBOARD EMERGENCY MEASURES. Fire-fighting drills. Submitted by the Republic of Korea

Iranian Classification Society Convention and Legislation Department Code: Tech Contents

Rules and Regulations for the Classification of a Floating Offshore Installation at a Fixed Location

Additional Fire Protection (F-AMC)

FIRE SAFETY SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS MACHINERY AND SYSTEMS MAIN CLASS PART 4 CHAPTER 10 JULY 2006

MOBILE OFFSHORE DRILLING UNITS 2014

Can we use knowledge and experience from other sectors to prove Water mist s suitability for land applications? UK Water Mist Seminar 8th March 2016

MARINE CIRCULAR MC-7/2011/1

EC-Type Examination (Module B) Certificate. A.1/3.11 b "B" dass divisions, fire integrity

PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

ei DG UV Test EC-Type Examination (Module B) Certificate

Attachment 1. to ClassNK Technical Information No. TEC-1077 Isle of Man Ship Registry Manx Shipping Notice SOLAS II-2 The Maintenance and inspection o

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

INFORMATION BULLETIN No. 150

COMMONWEALTH OF DOMINICA

REQUEST FOR PROPOSAL No Fire Extinguishers, Fire Suppression, Fire Alarms, Emergency Lighting & Sprinkler Systems Maintenance

F-03 FIXED FIRE DETECTION AND FIRE ALARM SYSTEM

IMO. Resolution A.952(23) Adopted on 5 December 2003 (Agenda item 17) GRAPHICAL SYMBOLS FOR SHIPBOARD FIRE CONTROL PLANS

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

GUIDE TO APPROVAL OF RETROFIT BALLAST WATER MANAGEMENT SYSTEM INSTALLATIONS

Government of Bermuda Bermuda Shipping and Maritime Authority BERMUDA SHIPPING NOTICE

SECTION (09950) - WALL COVERINGS

ADDITIONAL FIRE PROTECTION (F-AMC)

IMO FP 53 Agenda Preview

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

FIRE SUPPRESSION SOLUTIONS

Ship Name: DORIS T Ship Type: General Dry Cargo Ship. Organization

MSC Guidelines for Foam Fire Suppression Systems

EU CERTIFICATE OF CONFORMITY

ACCOMMODATION BARGES GUIDE FOR BUILDING AND CLASSING JANUARY 2014

ENHANCED FIRE PROTECTION ARRANGEMENTS

OFFSHORE STANDARD DNV-OS-D301 FIRE PROTECTION JANUARY 2001 DET NORSKE VERITAS

ClassNK Technical Information No. TEC-0970 For any questions about the above, please contact: NIPPON KAIJI KYOKAI (ClassNK) Survey Department, Adminis

MSC Guidelines for General Emergency Alarm & Public Address Systems

IMO MSC 94 Summary Report on Polar Code

Transcription:

LR427.201.12 CERTIFICATE OF FIRE APPROVAL This is to certify that The product detailed below will be accepted f compliance with the applicable Lloyd s Register Rules and Regulations and with the International Convention f the Safety of Life at Sea, (SOLAS), 1974, as amended, f use on ships and offshe installations classed with Lloyd s Register, and f use on ships and offshe installations when authised by contracting governments to issue the relevant certificates, licences, permits etc. Manufacturer VID Fire-Kill ApS Address Svalbardvej 1 DK-5700 Svendbg Denmark Type Description AUTOMATIC SPRINKLER, FIRE DETECTION AND FIRE-ALARM SYSTEM Fixed Fire Extinguishing System Type: OH Nozzles f Accommodation Spaces, Service Spaces and Control Stations Equivalent to SOLAS II-2/10.6.1 and IMO FSS Code, Chapter 8 (limited to sprinkler nozzles and their perfmance) Specified Standard IMO Resolution A.800(19), as amended by Resolutions MSC.265(84) and MSC. 284(86) The attached Design Appraisal Document fms part of this certificate. This certificate remains valid unless cancelled revoked, provided the conditions in the attached Design Appraisal Document are complied with and the equipment remains satisfacty in service. of issue 11 October 2016 Expiry date 10 October 2021 Certificate No. SAS F17000 Signed Lloyd's Register EMEA Sheet No 1 of 8 Name S. Abraham Survey to Lloyd s Register EMEA A Member of the Lloyd s Register Group Note: This certificate is not valid f equipment, the design manufacture of which has been varied modified from the specimen tested. The manufacturer should notify Lloyd s Register of any modification changes to the equipment in der to obtain a valid Certificate. Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees agents are, individually and collectively, referred to in this clause as the 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person f any loss, damage expense caused by reliance on the infmation advice in this document howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity f the provision of this infmation advice and in that case any responsibility liability is exclusively on the terms and conditions set out in that contract. This is a copy of an electronic document. In the event of any conflict ambiguity between the copy and the electronic document, which is retained and published by Lloyd's Register, the iginal electronic and certified version shall always prevail.

Email med@lr.g 2 of 8 SAS F17000 SOUTSO/SFS/TA/FF/SA/WP266926 ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. SAS F17000 This Design Appraisal Document fms part of the Certificate. APPROVAL DOCUMENTATION DFL (Danish Fire Labaties/Svendbg Denmark) Test Repts: 91210-40, dated 15 December 2009; 10041-42, dated 15 April 2010; 100809-44, dated 1 August 2010; 110415-5, dated 15 April 2011 SP Sweden Test Rept: F71487, dated 24 September 2007. CONDITIONS OF CERTIFICATION 1. The system has been designed in accdance with IMO Resolution A800(19) as amended by Resolution MSC 265(84), Annex, section, Principle Requirements f the System, IMO Resolution MSC.44(65), Standards f Fixed Sprinkler Systems f High-Speed Craft. 2. F use in the Accommodation and Service Spaces with a ceiling height not exceeding 5 metres. The capacity and arrangement of the spray nozzles is to be justified having regard to all identified fire risks in the protected space(s) and shall be located as denoted in 2.1 Table 2-1 f Passenger Ships carrying me than 6 Passengers OR; 2.2 Table 2-2 f Passenger Ships carrying not me than 6 Passengers, Cargo Ships and Yachts OR; 2. Table 2- f High Speed Passenger Craft OR 2.4 When the system is provided on board LR Classed Inland Waterways Passenger Ships, the capacity and arrangement of the nozzles shall be specially considered in the design stage in all case. Production items are to be manufactured in accdance with a quality control system which shall be maintained to ensure that items are of the same standard as the approved prototype 4. See GENERAL NOTES This is a copy of an electronic document. In the event of any conflict ambiguity between the copy and the electronic document, which is retained and published by Lloyd's Register, the iginal electronic and certified version shall always prevail.

Email med@lr.g of 8 SAS F17000 SOUTSO/SFS/TA/FF/SA/WP266926 ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. SAS F17000 Table 2-1 - Recommended Nozzle Arrangements f Passenger Ships carrying me than 6 Passengers. Space Designation (1) Fire Risk Categy (1) Maximum Area of Space Nozzle Designation Spacing Maximum Distance to Bulkheads/ Ceilings m 2 m m Control Stations 1 Unlimited Stairways Crids (Width 1.5m) (4) 2 Unlimited OH-CO.0 Centred across width Stairways Crids 2 Unlimited (Width > 1.5m) (4) Accommodation Spaces of Min Moderate Fire Risk and; Sanitary & Similar Spaces 6, 7 9 18 OH-SWC Centred in front wall of cabin 0.12 Accommodation Spaces of Min Moderate Fire Risk and; Sanitary & Similar Spaces 6, 7 9 18 to 50, And >50 Accommodation Spaces of Greater Fire Risk 8 Unlimited Refrigerated Chambers and; Main Galleys and annexes, Pantries containing cooking Appliances each >5kW Ste Rooms, Wkshops, Pantries containing cooking Appliances each <5kW etc; Other spaces in which flammable liquids are sted 11, 12 Unlimited 1 14 Unlimited OH-PX1 NOTES (1) Space Designations and Fire Risk Categies are in accdance with SOLAS II-2/Reg 9.2.2.. (2) Space with a 2.5 m ceiling height. () Space with a ceiling height greater than 2.5m, but less than equal to 5m. (4) Width of the Crids Stairways are to be measured between the bulkheads bounding the space. This is a copy of an electronic document. In the event of any conflict ambiguity between the copy and the electronic document, which is retained and published by Lloyd's Register, the iginal electronic and certified version shall always prevail.

Email med@lr.g 4 of 8 SAS F17000 SOUTSO/SFS/TA/FF/SA/WP266926 ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. SAS F17000 Table 2-2 - Recommended Nozzle Arrangements f Passenger Ships carrying not me than 6 Passengers, Cargo Ships and Yachts. Space Designation (1) Fire Risk Categy (1) Maximum Area of Space Nozzle Designation Spacing Maximum Distance to Bulkheads m 2 m m Control Stations 1 Unlimited Stairways Crids (Width 1.5m) (4) 2 4 Unlimited OH-CO.0 Centred across width Stairways Crids 2 4 Unlimited (Width > 1.5m) (4) Accommodation Spaces and Service Spaces (Low Risk) 5 18 OH-SWC Centred in front wall of cabin 0.12 Accommodation Spaces and Service Spaces (Low Risk) Service Spaces (High Risk) Galleys, Pantries containing cooking Appliances each >5kW Service Spaces (High Risk) Ste Rooms, Wkshops, Pantries containing cooking Appliances each <5kW etc; Other spaces in which flammable liquids are sted 5 >18 9 8 (5) Unlimited 9 8 (5) Unlimited OH-PX1 NOTES (1) Space Designations and Fire Risk Categies are in accdance with SOLAS II-2/Reg 9.2.2.4, SOLAS II-2/Reg 9.2., and LR Rules and Regulations f the Classification of Special Service Craft, Part 17, Chapter,.6 (2) Space with a 2.5 m ceiling height. () Space with a ceiling height greater than 2.5m, but less than equal to 5m. (4) Width of the Crids Stairways are to be measured between the bulkheads bounding the space. (5) Service Spaces (High Risk) are Categy (8) spaces f Yachts only. This is a copy of an electronic document. In the event of any conflict ambiguity between the copy and the electronic document, which is retained and published by Lloyd's Register, the iginal electronic and certified version shall always prevail.

Email med@lr.g 5 of 8 SAS F17000 SOUTSO/SFS/TA/FF/SA/WP266926 ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. SAS F17000 Table 2- - Recommended Nozzle Arrangements f High Speed Passenger Craft. Space Designation (1) Fire Risk Categy (1) Maximum Area of Space Nozzle Designation Spacing Maximum Distance to Bulkheads m 2 m m Public Spaces C Unlimited Service Spaces and Bond B Unlimited OH-PX1 Ste Rooms Ste-rooms containing flammable liquids A Unlimited OH-PX1 NOTES (1) Space Designations and Fire Risk Categies are in accdance with IMO Resolution MSC.97(7), International Code of Safety f High Speed Craft, 7. (2) Space with a 2.5 m ceiling height. () Space with a ceiling height greater than 2.5m, but less than equal to 5m. Spaces required to be covered by a watermist system are denoted in IMO Resolution MSC.97(7), International Code of Safety f High Speed Craft, 7.1. GENERAL NOTES 1. The as tested nozzles have brass bodies externally with frangible glass bulbs with a nominal release temperature of 57 C of type JOB F2 (2.0 mm diameter). The nozzle characteristics are delineated in Table 1-1: Table 1-1 - Nozzle Characteristics Nozzle Name Nozzle Designation Pressure K- fact Flow Bar l/min*bar 1/2 l/min Cabin OH-SWC 6.0 2.0 56.4 Crid OH-CO 6.0 15.5 7.96 Public Space OH-L1 6.0 1.5.07 (2.5 m Ceiling Height) Public Space OH-L2 6.0 14.5 5.52 (5 m Ceiling Height) Shopping/Stage OH-PX1 9.0 2.0 69.00 2. The minimum nozzle pressure being 6 bar, and 9.0 bar respectively, see Table 1-1. The system should be capable of continuously supplying the water-based extinguishing medium f a minimum of 0 min. A pressure tank other means should be provided to meet the functional requirement stipulated in the FSS Code, Chapter 8, Paragraph 2..2.1. The design of the system should ensure that full system pressure is available at the most remote nozzle in each section within 60 seconds of system activation This is a copy of an electronic document. In the event of any conflict ambiguity between the copy and the electronic document, which is retained and published by Lloyd's Register, the iginal electronic and certified version shall always prevail.

Email med@lr.g 6 of 8 SAS F17000 SOUTSO/SFS/TA/FF/SA/WP266926 ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. SAS F17000 4. There should be not less than two sources of power f the system. Where the sources of power f the pump are electrical, these should be a main generat and an emergency source of power. One supply should be taken from the main switchboard, and one from the emergency switchboard by separate feeders reserved solely f that purpose. The feeders should be so arranged as to avoid galleys, machinery spaces and other enclosed spaces of high fire risk except in so far as it is necessary to reach the appropriate switchboards, and should be run to an automatic changeover switch situated near the sprinkler pump. This switch should permit the supply of power from the main switchboard so long as a supply is available there from, and be so designed that on failure of that supply it will automatically change over to the supply from the emergency switchboard. The switches on the main switchboard and the emergency switchboard should be clearly labelled and nmally kept closed. No other switch should be permitted in the feeders concerned. One of the sources of power supply f the system should be an emergency source 5. Where one of the sources of power f the pump is an internal combustion engine, it should, in addition to complying with the provisions of the FSS Code, chapter 8, paragraph 2.4., be so situated that a fire in any protected space will not affect the air supply to the machinery. Pump sets consisting of two diesel engines each supplying at least 50% of the required water capacity are considered acceptable if the fuel supply is adequate to operate the pumps at full capacity f a period of 6 h on passenger ships and 18 h on cargo ships 6. The system should be provided with a redundant means of pumping, including drivers, otherwise supplying a water-based extinguishing medium to the sprinkler system. The capacity of the redundant means of should be sufficient to compensate f the loss of any single supply pump alternative source 7. Failure of any one component in the power and control system should not result in a reduction the automatic release capability reduction of sprinkler pump capacity by me than 50%. Hydraulic calculations should be conducted to assure that sufficient flow and pressure are delivered to the hydraulically most remote 140m2 in the event of the failure of any one component 8. Each section of sprinklers should be capable of being isolated by one stop valve only. The stop-valve in each section should be readily accessible in a location outside of the associated section in cabinets within stairway enclosures. The valve s location should be clearly and permanently indicated. Means should be provided to prevent the operation of the stop-valves by an unauthised person. Isolation valves used f service, maintenance f refilling of antifreeze solutions may be installed in the sprinkler piping in addition to the section stop valves, if provided with a means f giving a visual and audible alarm as required by Note 9 below. Valves on the pump unit may be accepted without such alarms if they are locked in the crect position 9. Each sprinkler section should be provided with a means f giving a visual and audible alarm at a continuously manned central control station within one minute of flow from one me sprinklers, a check valve, pressure gauge, and a test connection with a means of drainage 10. Piping and Reservoir tank material (where applicable) shall be made of stainless steel having a minimum grade of AISI 04L 11. The system should be fitted with a permanent sea inlet and be capable of continuous operation using seawater This is a copy of an electronic document. In the event of any conflict ambiguity between the copy and the electronic document, which is retained and published by Lloyd's Register, the iginal electronic and certified version shall always prevail.

Email med@lr.g 7 of 8 SAS F17000 SOUTSO/SFS/TA/FF/SA/WP266926 ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. SAS F17000 12. The system water supply components, such as, pump units and pressure tanks should be outside Categy A Machinery Spaces and should not be situated in any space required to be protected by the sprinkler system 1. Pumps and alternative supply components should be capable of supplying the required flow rate and pressure f the space with the greatest hydraulic demand. F the purposes of this calculation, the design area used to calculate the required flow and pressure should be the deck area of the most hydraulically demanding space, separated from adjacent spaces by A-Class divisions. The design area need not exceed 280m². F application to a small ship with a total protected area of less than 280m², the Administration may specify the appropriate area f sizing of pumps and alternative supply components. Copies of calculations are to be submitted f acceptance in each case where it is proposed to install this system 14. The pump unit shall have on the pressure side a mess strainer (mesh size No. 50, 00μm) 15. The system stage containers and associated pressure components are to be designed and tested to codes of practice recognized by Lloyd s Register, indicating that they can withstand the pressure expected in service, giving regard to their installed location 16. The as tested nozzles have brass bodies and chrome plated bodies. Each individual water spray nozzle shall be fitted with a mesh strainer (mesh size No. 16, 1200μm) 17. The number of spare watermist nozzles which are to be specified f each application is to be in accdance with Table 8-1 Table 8-1 - Required Number of Spare Nozzles Number of Installed Nozzles Spares Nozzles Required 00 6 00 to 1000 12 >1000 24 18. The use of the following system arrangements must be specially considered at the design stage in all cases: 19.1 Nozzle types and arrangements f the protection of windows 19.2 Any dry pipe pre-action system installations 19. Protection of Public Spaces with a ceiling height greater than 5 metres 19.4 F atriums with intermediate level deck openings exceeding 100m², ceiling mounted sprinklers are not required 19.5 The system should be designed in such a way that during a fire occurrence, the level of protection provided to those spaces unaffected by fire is not reduced 19.6 Any parts of the system which may be subjected to freezing temperatures in service should be suitably protected against freezing 19.7 Sprinklers should be grouped into separate sections. Any section should not serve me than two decks of one main vertical zone 19.8 Sprinkler piping should not be used f any other purpose This is a copy of an electronic document. In the event of any conflict ambiguity between the copy and the electronic document, which is retained and published by Lloyd's Register, the iginal electronic and certified version shall always prevail.

Email med@lr.g 8 of 8 SAS F17000 SOUTSO/SFS/TA/FF/SA/WP266926 ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. SAS F17000 19. Arrangement drawings and calculations are to be submitted f acceptance in each case where it is proposed to install this system. Control panel schematics are also to be submitted. All principle components of the system are to be identified with their location in relation to the protected space(s) indicated. Additionally, the fire risk categy of the protected spaces must be indicated on the plans 20. The pumps are to be constructed under survey. Additionally, the system pipe wk including; flexible hoses, pipes, valves and fittings are to be LR Approved, in accdance with Lloyd s Register Rules, Part 5, Chapter 12 21. Any fire detection and alarm system installed in conjunction with this system is outside of the scope of this Fire Approval Certificate and must have a currently valid LR Type Approval Certificate 22. The control system being surveyed at the manufacturers wks pri to installation on board 2. Installation plans and operating manuals should be supplied to the ship and be readily available on board. A list plan should be displayed showing the spaces covered and the location of the zone in respect of each section. Instructions f testing and maintenance should also be available on board. The maintenance instructions should include provisions f a flow test of each section at least annually to check f possible clogging deteriation in the discharge piping. Copies are to be submitted f acceptance in each case where it is proposed to install this system 24. Installation onboard: The onboard arrangements and installation of this system are not part of this Design Appraisal Certificate. All such arrangements are to be to the satisfaction of the Surveys attending on board. On completion of the installation final acceptance of the system is dependent on satisfacty survey and testing in the accdance with the manufacturer s design, installation, operation and maintenance manual PLACE OF PRODUCTION VID Fire-Kill ApS Svalbardvej 1 DK-5700 Svendbg Denmark Lloyd's Register EMEA LR427.201.12 Saji Abraham Seni Specialist Statuty Fire & Safety Southampton Technical Suppt Office, Marine & Offshe Lloyd s Register EMEA Supplementary Type Approval Terms and Conditions This certificate and Design Appraisal Document relates to type approval, it certifies that the prototype(s) of the product(s) referred to herein has/have been found to meet the applicable design criteria f the use specified herein, it does not mean imply approval f any other use, n approval of any products designed manufactured otherwise than in strict confmity with the said prototype(s). This is a copy of an electronic document. In the event of any conflict ambiguity between the copy and the electronic document, which is retained and published by Lloyd's Register, the iginal electronic and certified version shall always prevail.