G101 SCHOOL AIR CONDITIONING UPGRADE - PROJECT #3 SUNSET ELEMENTARY COOLING UPGRADE 2014 NORTH 250 WEST SUNSET, UTAH 84015

Similar documents
Appendix B. Symbols for Drawings. Table B.1. Air moving devices and ductwork symbols. Air Movement. Fans. Axial flow fan.

DOCUMENT TABLE OF CONTENTS

EXHAUST FAN SCHEDULE

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

FIRE SUPPRESSION SPRINKLER SYSTEM

900 N. Via Piemonte Ontario, CA

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

FRESH FROM THE KITCHEN FRESH FROM THE KITCHEN

GENERAL PLUMBING NOTES

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:

1.1 This section applies to air handling units for HVAC Systems.

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Florida Department of Transportation

A. This Section includes the following domestic water piping specialties:

PROJ. NO SECTION REFRIGERANT PIPING

COHASSET, MA March 6, The following is the HVAC outline specifications, which defines the scope of work of the HVAC system.

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

DIVISION 15 MECHANICAL

PLAN REVIEW SUBMITTAL GUIDE

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

PROPOSED NEW BUILDING

SECTION AIR DUCT ACCESSORIES

SECTION (15530) - REFRIGERANT PIPING

REFRIGERANT PIPING

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

SECTION DUCTWORK

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

Project General Notes DESCRIPTION ABBREVIATIONS AIR CONDITIONER ABOVE FINISHED FLOOR BALANCING DAMPER

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

WineZone Ceiling Mount Ductless Split 15

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

SECTION AIR COILS

Modular Heating & Ventilating Unit Model IGX-HV

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Job Name Control Systems Description Date

Modular Supply Make-Up Air Unit

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

A. This Section includes the following emergency plumbing fixtures:

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

Indirect Gas-Fired Make-Up Air

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

SECTION DOMESTIC WATER PIPING SPECIALTIES

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

City of Duluth Festival Center 04/25

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Springpoint Architects, pc SECTION Childcare Center Architect s Project No TABLE OF CONTENTS Monroe County Comm. Sch. Corp.

SAS Steadyair Make-Up Air Units Technical Guide

FCC Fan-Coil Units High-Performance, Vertical

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Virginia Tech Standards for Building Automation System

IMC Significant Changes Summary Tier I

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

SECTION (15530) - REFRIGERANT PIPING

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION HUMIDITY CONTROL EQUIPMENT

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

HVAC Equipment Access Equipment Location

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

TESTING, ADJUSTING AND BALANCING

SECTION AIR DOORS

NYC Department of Education

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

NEW CHILLER SCHEDULE

COMcheck Software Version Interior Lighting Compliance Certificate

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Revitalize Building Mechanical Systems (4619)

DESIGN & CONSTRUCTION GUIDELINES

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

NC State University Design and Construction Guidelines Division 23 Basic Mechanical Requirements

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

SECTION PLUMBING/HVAC FINAL TESTING, ADJUSTING AND BALANCING

Transcription:

DRAWING INDEX GENERAL G0 PLUMBING P00 P0A P0B P0C P0A P0A P0B COVER SHEET PLUMBING LEGEND AND GENERAL NOTES PLUMBING PLAN PLUMBING PLAN PLUMBING PLAN PLUMBING ROOF DEMOLITION PLAN PLUMBING ROOF REMODEL PLAN PLUMBING ROOF PLAN PLUMBING ROOF PLAN P0C MECHANICAL M00 MD0A MD0C M0A M0B M0C M0A M0B M0C MECHANICAL LEGEND AND GENERAL NOTES MECHANICAL ROOF DEMO. PLAN MECHANICAL ROOF DEMO. PLAN MECHANICAL PLAN MECHANICAL PLAN MECHANICAL PLAN MECHANICAL ROOF PLAN MECHANICAL ROOF PLAN MECHANICAL ROOF PLAN MECHANICAL SCHEDULES, CONTROLS AND DETAILS M0 ELECTRICAL E0. E. E. E. SYMBOLS, SCHEDULES AND NOTES ELECTRICAL PLAN- ELECTRICAL PLAN- ELECTRICAL PLAN- UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UTAH 80 7 WEST 00 SOUTH SUITE#0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 S PROJECT ENGINEER: HAL ABERCROMBIE CELL: (80) 0-008 EMAIL: habercrombie@dljeng.com PROJECT INFORMATION REVISION: DLJ PROJECT NUMBER: 0 I:\JOBS0\0\CAD\CUG0.dwg, /0/07 :9: PM, taargyle MARCH, 07 G0

. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS WHICH ARE OBVIOUSLY AND REASONABLY NECESSARY TO COMPLETE THE INSTALLATION.. THE CONTRACTOR SHALL TAKE OUT PERMITS, PROCURE CERTIFICATES AND PAY FEES CONNECTED THEREWITH. PLUMBING GENERAL NOTES 9. PLUMBING/PIPING IS SHOWN SCHEMATICALLY FOR VIEWING PURPOSES ONLY; DURING INSTALLATION FIELD MODIFICATIONS TO ROUTING MAY BE REQUIRED. 0. INSTALL ALL REQUIRED CLEANOUTS TO CLEAR EQUIPMENT AND FIXTURES. WALL CLEAN OUT CLEAN OUT SYMBOL WCO CO PLUMBING LEGEND DOMESTIC COLD WATER PIPING INDUSTRIAL COLD WATER PIPING NOTE: NEW ITEMS SHOWN DARK, EXISTING ITEMS SHOWN LIGHT. ALL ITEMS MAY NOT APPEAR ON DRAWINGS. SYMBOL ICW 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999. BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS SURROUNDING THE PROJECT PRIOR TO BIDDING.. ALL WORK SHALL BE PROPERLY TESTED, BALANCED AND CLEANED AND DISINFECTED. PROVIDE A ONE YEAR WARRANTY FROM OF FINAL INSPECTION ON ALL PARTS AND LABOR. CLEAN OUT TO GRADE FLOOR CLEAN OUT COTG FCO SOFT COLD WATER PIPING DOMESTIC HOT WATER PIPING SCW. THE CONTRACTOR IS REFERRED TO ARCHITECTURAL, STRUCTURAL, ELECTRICAL PLANS AND SPECIFICATIONS. SUCH PLANS AND SPECIFICATIONS ARE CONTRACT DOCUMENTS.. DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE LOCATIONS.. ALL PLUMBING WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE LATEST EDITION OF THE PREVAILING STATE MECHANICAL/PLUMBING AND BUILDING CODES AS WELL AS ALL REGULATIONS THAT MAY APPLY. IN CASE OF CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND A GOVERNING CODE OR ORDINANCE THE MORE STRINGENT STANDARD SHALL APPLY. 7. NO PIPING SHALL RUN EXPOSED IN FINISHED AREAS UNLESS NOTED OTHERWISE. 8. RUN-OUT SIZES TO INDIVIDUAL PLUMBING FIXTURES TO BE EQUAL TO ROUGH-IN SIZE NOTED IN THE PLUMBING FIXTURE SCHEDULE.. TERMINATE PLUMBING VENTS AT A MINIMUM OF 0' FROM ALL AIR HANDLING EQUIPMENT INTAKE VENTS.. CONTRACTOR SHALL VERIFY LOCAL CODE REQUIREMENTS FOR INDIRECT CONNECTIONS FOR FOOD PREP AREAS. CONNECTIONS SHALL BE PROVIDED WITH A MINIMUM " AIR GAP, UNLESS OTHERWISE NOTED.. PRESSURIZED PIPING SHALL NOT BE RUN IN ANY AREA SUBJECT TO FREEZING.. PRIOR TO INSTALLING ANY PIPING, VERIFY DEPTH OF CONNECTION POINTS OF GRADE DEPENDENT PIPING AND CONFIRM IN WRITING TO ENGINEER.. WHERE RATED ASSEMBLIES ARE PENETRATED BY DUCTS, PIPES OR OTHER ITEMS, THE "F" AND "T" RATING SHALL BE MAINTAINED WITH REQUIRED UL LISTED ASSEMBLIES OR SEALANT AS REQUIRED BY THE APPLICABLE CODE OR AUTHORITY HAVING JURISDICTION. DROP RISE CAPPED PIPE PIPE REDUCER BALL VALVE GATE VALVE AUTOMATIC TWO-WAY VALVE AUTOMATIC THREE-WAY VALVE TEMPERING VALVE UNION TWS INDUSTRIAL HOT WATER PIPING SOFT HOT WATER PIPING DOMESTIC HOT WATER RECIRCULATION PIPING DOMESTIC TEMPERED WATER VENT PIPING ACID VENT PIPING WASTE PIPING (ABOVE GRADE OR FLOOR) WASTE PIPING (BELOW GRADE OR FLOOR) ACID WASTE PIPING (ABOVE GRADE OR FLOOR) ACID WASTE PIPING (BELOW GRADE OR FLOOR) IHW SHW TWS AV AW AW GAS COCK VALVE GREASE WASTE PIPING (ABOVE GRADE OR FLOOR) GW PRESSURE REGULATOR GREASE WASTE PIPING (BELOW GRADE OR FLOOR) GW STRAINER HAMMER ARRESTOR CHECK VALVE CIRCUIT SETTER BUTTERFLY VALVE BACKFLOW PREVENTOR RELIEF VALVE MANUAL AIR VENT THERMOMETER FLEXIBLE PIPING INLINE PUMP DIRECTION OF SLOPE FLOW DIRECTION ACCESS DOOR FLOW METER R FM PROCESS WASTE PIPING (ABOVE GRADE OR FLOOR) PROCESS WASTE PIPING (BELOW GRADE OR FLOOR) ROOF DRAIN PIPING (ABOVE GRADE OR FLOOR) ROOF DRAIN PIPING (BELOW GRADE OR FLOOR) SECONDARY ROOF DRAIN PIPING GAS PIPING COMPRESSED AIR PIPING CARBON DIOXIDE PIPING NITROGEN PIPING NITROUS OXIDE PIPING OXYGEN PIPING VACUUM PIPING DEIONIZED WATER PIPING DRAIN PIPING FIRE SPRINKLER PIPING KEYED NOTE PW PW RD RD SRD G A C0 N NO O VAC DIW D F # UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 WATER METER W PLUMBING FIXTURE CALLOUT P-?? DEVICE IN DROP DETAIL NUMBER SHEET DETAIL APPEARS EQUIPMENT CALLOUT LARGE SCALE NUMBER SHEET LARGE SCALE APPEARS SECTION LETTER SHEET NUMBER ROOM NAME ROOM NUMBER X S# X-# TOP BOT ROOM N0 # S# MARCH, 07 0 I:\JOBS0\0\CAD\CUP00.DWG I:\JOBS0\0\CAD\CUP00.dwg, /0/07 :9:7 PM, taargyle REVISION DELTA NEW CONNECTION # PLUMBING LEGEND AND GENERAL NOTES P00

KEYED NOTES FOR SHEET P0A EXISTING /" COPPER DOMESTIC COLD WATER PIPING UP THROUGH ROOF AT THIS LOCATION. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 GYM MEDIA CENTER I:\JOBS0\0\CAD\CUP0A.dwg, /0/07 :9:0 PM, taargyle 7 WALK-IN COOLER SERVING -/" /" WALK-IN COOLER " OFFICE 8 FAN ROOM ELEC. ROOM COMP. LAB 9 /" UP BREAKROOM HEALTH 0 SCALE: /8"='0" HEALTH TEACHERS WORK ROOM PLUMBING PLAN ADMINISTRATION. NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 MARCH, 07 0 I:\JOBS0\0\CAD\CUP0A.DWG PLUMBING PLAN P0A

KEYED NOTES FOR SHEET P0B EXISTING /" COPPER DOMESTIC COLD WATER PIPING UP THROUGH ROOF AT THIS LOCATION. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 OFFICE TEACHERS WORK ROOM COMPUTER LAB A B 0 /" UP 0 0 OFFICE AFTER HOURS CAFETERIA UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 A 7A CL I:\JOBS0\0\CAD\CUP0B.dwg, /0/07 :9: PM, taargyle PLUMBING PLAN SCALE: /8"='0". NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, COAT ROOM MARCH, 07 0 I:\JOBS0\0\CAD\CUP0B.DWG PLUMBING PLAN P0B

KEYED NOTES FOR SHEET P0C EXISTING /" COPPER DOMESTIC COLD WATER PIPING UP THROUGH ROOF AT THIS LOCATION. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 0 0 9 8 /" UP SERVER ROOM 0 0 7 UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 I:\JOBS0\0\CAD\CUP0C.dwg, /0/07 :9: PM, taargyle PLUMBING PLAN SCALE: /8"='0". NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, MARCH, 07 0 I:\JOBS0\0\CAD\CUP0C.DWG PLUMBING PLAN P0C

KEYED NOTES FOR SHEET P0A REMOVE EXISTING DOMESTIC WATER LINE SHOWN HATCHED. FOR REMOVAL OF EVAPORATIVE COOLER. EXISTING EVAPORATIVE COOLER. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 /" DOWN /" SLOPE /8". NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 MARCH, 07 0 I:\JOBS0\0\CAD\CUP0A.DWG I:\JOBS0\0\CAD\CUP0A.dwg, /0/07 :9:7 PM, taargyle PLUMBING ROOF DEMOLITION PLAN SCALE: /8"='0" PLUMBING ROOF DEMOLITION PLAN P0A

KEYED NOTES FOR SHEET P0A EXISTING EVAPORATIVE COOLER. EXISTING SKYLIGHT (TYPICAL). EXISTING ROOF DRAIN LOCATION (TYPICAL). CONNECT /" BLACK POLY TUBING TO EXISTING /" COPPER PIPING AT THIS LOCATION. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 I:\JOBS0\0\CAD\CUP0A.dwg, /0/07 :9:9 PM, taargyle EC- /8" /8" EC- /8" /8" /" DOWN /" SLOPE /" EC- /8" /8" /8" EC- EC- PLUMBING ROOF REMODEL PLAN SCALE: /8"='0". NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 MARCH, 07 0 I:\JOBS0\0\CAD\CUP0A.DWG PLUMBING ROOF REMODEL PLAN P0A

KEYED NOTES FOR SHEET P0B EXISTING EVAPORATIVE COOLER. EXISTING SKYLIGHT (TYPICAL). EXISTING ROOF DRAIN LOCATION (TYPICAL). CONNECT /8" BLACK POLY TUBING TO EXISTING COPPER PIPING AT THIS LOCATION. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 /8" /8" SLOPE /" /8" /" DOWN /" SLOPE /" /8" /8" EC- /8" EC- UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 /8" I:\JOBS0\0\CAD\CUP0B.dwg, /0/07 :0:0 PM, taargyle EC- EC- SCALE: /8"='0" EC- PLUMBING ROOF PLAN. NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, EC- MARCH, 07 0 I:\JOBS0\0\CAD\CUP0B.DWG PLUMBING ROOF PLAN P0B

KEYED NOTES FOR SHEET P0C EXISTING EVAPORATIVE COOLER. EXISTING SKYLIGHT (TYPICAL). EXISTING ROOF DRAIN LOCATION (TYPICAL). CONNECT /8" BLACK POLY TUBING TO COPPER PIPING AT THIS LOCATION. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 EC- EC- EC- /8" /8" EC- /" EC- /8" /8" EC- /" /" DOWN /" /8" EC- /8" EC- /8" EC- UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 I:\JOBS0\0\CAD\CUP0C.dwg, /0/07 :0:0 PM, taargyle PLUMBING ROOF PLAN SCALE: /8"='0". NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, MARCH, 07 0 I:\JOBS0\0\CAD\CUP0C.DWG PLUMBING ROOF PLAN P0C

. CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS WHICH ARE OBVIOUSLY AND REASONABLY NECESSARY TO COMPLETE THE INSTALLATION.. THE CONTRACTOR SHALL TAKE OUT PERMITS, PROCURE CERTIFICATES AND PAY FEES CONNECTED THEREWITH.. BIDDERS SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS SURROUNDING THE PROJECT PRIOR TO BIDDING.. THE CONTRACTOR IS REFERRED TO ARCHITECTURAL, STRUCTURAL, ELECTRICAL PLANS AND SPECIFICATIONS. SUCH PLANS AND SPECIFICATIONS ARE CONTRACT DOCUMENTS.. DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE LOCATIONS.. ALL MECHANICAL HVAC WORK SHALL BE PREFORMED IN STRICT ACCORDANCE WITH THE LATEST EDITION OF THE PREVAILING STATE MECHANICAL/PLUMBING AND BUILDING CODES AS WELL AS ALL REGULATIONS THAT MAY APPLY. IN CASE OF CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND A GOVERNING CODE OR ORDINANCE THE MORE STRINGENT SHALL APPLY. 7. DIFFUSER RUN OUTS SHALL BE THE SAME AS LISTED DIFFUSER NECK SIZE, UNLESS OTHERWISE NOTED. HVAC GENERAL NOTES 8. COORDINATE EXACT LOCATION OF AIR DISTRIBUTION DEVICES WITH CEILING GRID AND LIGHT FIXTURE LAYOUT. 9. ALL RECTANGULAR SUPPLY DUCT ELBOWS SHALL HAVE TURNING VANES. 0. RECTANGULAR DUCT SIZES SHOWN INDICATE REQUIRED AIRFLOW SIZES. SHEETMETAL CONTRACTOR SHALL INCREASE SIZES TO ALLOW FOR LINER.. NO DUCTWORK SHALL BE FABRICATED WITHOUT FIRST FIELD VERIFYING THAT THE AVAILABLE SPACE UNDER ACTUAL JOB CONDITIONS WILL PERMIT INSTALLATION OF THE DUCTWORK WITHOUT STRUCTURAL OR OTHER CONFLICTS. DUCT SIZES THAT REQUIRE ON THE JOB MODIFICATION DUE TO UNFORESEEN OBSTRUCTIONS SHALL BE MADE WITHOUT ANY ADDITIONAL COST TO THE OWNER.. MAINTAIN A 0'-0" BETWEEN OUTSIDE AIR INTAKES AND PLUMBING/EXHAUST VENTS.. WHERE RATED ASSEMBLIES ARE PENETRATED BY DUCTS, PIPES OR OTHER ITEMS, THE "F" AND "T" RATING SHALL BE MAINTAINED WITH REQUIRED UL LISTED ASSEMBLIES OR SEALANTS AS REQUIRED BY THE APPLICABLE CODE OR AUTHORITY HAVING JURISDICTION. SYMBOL AUTOMATIC -WAY VALVE AUTOMATIC -WAY VALVE AUTOMATIC BALL FLOAT VENT BALL VALVE CAPPED END W/BALL VALVE CHECK VALVE COMBINATION BALANCING VALVE/ SHUTOFF DEVICE IN DROP DIRECTION OF SLOPE FLANGED BUTTERFLY VALVE MECHANICAL LEGEND SYMBOL IMMERSION WELL INLINE PUMP MANUAL VENT WITH BALL VALVE P & T PLUG IN IMMERSION WELL PIPE DROP PIPE INLINE DROP PIPE INLINE RISE PIPE RISER PNEUMATIC -WAY VALVE PRESSURE GUAGE NOTE: NEW ITEMS SHOWN DARK, EXISTING ITEMS SHOWN LIGHT. ALL ITEMS MAY NOT APPEAR ON DRAWINGS. SYMBOL BRANCH DUCT TAKE-OFF WITH MANUAL DAMPER DUCT FLEXIBLE CONNECTION TURNING VANES DUCT TEE CONNECTION DUCT TRANSITION SQUARE TO ROUND DUCT TRANSITION AUTOMATIC DAMPER VOLUME DAMPER 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 FLANGED ECCENTRIC REDUCER PRESSURE GAGE W/BALL VALVE BD BACK-DRAFT DAMPER FLANGED UNION R RELIEF VALVE DUCT ACCESS DOOR FLEXIBLE CONNECTION SCREWED CONCENTRIC REDUCER RETURN AIR, RISE AND DROP FM RL RS F FLOW DIRECTION FLOW METER GATE VALVE GLOBE VALVE REFRIGERANT PIPING - LIQUID REFRIGERANT PIPING - SUCTION REFRIGERANT SHUT-OFF VALVE EXPANSION VALVE MOISTURE INDICATING SIGHT GLASS FLEXIBLE CONNECTION FILTER DRIER PIPE SUPPORT WFS CWS CWR CHWS CHWR HWS STEAM TRAP STRAINER THERMOMETER THREADED HOSE CONNECTION UNION VENTURI WATER FLOW SWITCH CONDENSER WATER SUPPLY CONDENSER WATER RETURN CHILLED WATER SUPPLY CHILLED WATER RETURN HOT WATER HTG. SUPPLY θ OR FO T S J X-# X-# # # FD FSD SUPPLY AIR, RISE AND DROP EXHAUST AIR, RISE AND DROP OUTSIDE AIR, RISE AND DROP RELIEF AIR, RISE AND DROP ROUND DUCT, RISE AND DROP FLAT OVAL DUCT, RISE AND DROP FLAT OVAL DUCT FIRE DAMPER FIRE SMOKE DAMPER THERMOSTAT SENSOR J-BOX AIR DEVICE AIR DEVICE CFM KEYED NOTE UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 EXTERIOR PIPE SUPPORT HWR HOT WATER HTG. RETURN X-# EQUIPMENT CALLOUT S L EXTERIOR PIPE SUPPORT DIRECTION OF SLOPE DOWN SUCTION LINE LIQUID LINE TRAP. ONE PIECE FACTORY FABRICATED HPS LPS LPC GHS GHR HIGH PRESSURE STEAM PIPING LOW PRESSURE STEAM PIPING LOW PRESSURE CONDENSATE PIPING GLYCOL HEATING SUPPLY PIPING GLYCOL HEATING RETURN PIPING X S# TOP BOT ROOM N0 # S# DETAIL NUMBER SHEET DETAIL APPEARS LARGE SCALE NUMBER SHEET LARGE SCALE APPEARS AIR FLOW DIRECTION SECTION LETTER SHEET NUMBER ROOM NAME ROOM NUMBER MARCH, 07 0 I:\JOBS0\0\CAD\CUM00.DWG I:\JOBS0\0\CAD\CUM00.dwg, /0/07 :9:8 PM, taargyle # REVISION DELTA NEW CONNECTION ACCESS DOOR MECHANICAL LEGEND AND GENERAL NOTES M00

KEYED NOTES FOR SHEET MD0A EXISTING EVAPORATIVE COOLER. EXISTING SKYLIGHT (TYPICAL). EXISTING ROOF DRAIN (TYPICAL). EXISTING ROOFTOP UNIT. REMOVE EXISTING EVAPORATIVE COOLER AND ROOF CURB. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999. NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 MARCH, 07 0 I:\JOBS0\0\CAD\CUMD0A.DWG I:\JOBS0\0\CAD\CUMD0A.dwg, /0/07 :9: PM, taargyle MECHANICAL ROOF DEMOLITION PLAN SCALE: /8"='0" MECHANICAL ROOF DEMO. PLAN MD0A

KEYED NOTES FOR SHEET MD0C EXISTING EVAPORATIVE COOLER. EXISTING SKYLIGHT (TYPICAL). EXISTING ROOF DRAIN (TYPICAL). REMOVE EXISTING EVAPORATIVE COOLER AND ROOF CURB. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 I:\JOBS0\0\CAD\CUMD0C.dwg, /0/07 :9: PM, taargyle MECHANICAL ROOF DEMOLITION PLAN SCALE: /8"='0". NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, MARCH, 07 0 I:\JOBS0\0\CAD\CUMD0C.DWG MECHANICAL ROOF DEMO. PLAN MD0C

KEYED NOTES FOR SHEET M0A EXISTING EVAPORATIVE COOLER DIFFUSER. NEW BMS CONTROLS CABINET, DIVISION TO PROVIDE 0 VOLT CIRCUIT. PROVIDE COUNTER BALANCED BACKDRAFT DAMPER IN SUPPLY DUCT. POSITION WALL SWITCH FOR EVAPORATIVE COOLER - SEE CONTROLS DETAIL. TIE EXISTING EVAPORATIVE COOLER INTO NEW DDC CONTROLS, SEE DETAIL. WIRE EXISTING POSITION WALL SWITCH TO NEW EVAPORATIVE COOLER. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 GYM MEDIA CENTER I:\JOBS0\0\CAD\CUM0A.dwg, /0/07 :9: PM, taargyle WALK-IN COOLER SERVING 7 D- WALK-IN COOLER OFFICE 0"X0"UP 8 FAN ROOM ELEC. ROOM COMP. LAB $ 9 BREAKROOM HEALTH 0 HEALTH TEACHERS WORK ROOM $ $ $ $ D- 0"X0"UP D- 0"X0"UP SCALE: /8"='0" ADMINISTRATION (TYP) MECHANICAL PLAN D- 0"X0"UP. NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 MARCH, 07 0 I:\JOBS0\0\CAD\CUM0A.DWG MECHANICAL PLAN M0A

KEYED NOTES FOR SHEET M0B EXISTING EVAPORATIVE COOLER DIFFUSER. EXISTING SPLIT SYSTEM. NEW BMS CONTROLS CABINET, DIVISION TO PROVIDE 0 VOLT CIRCUIT. PROVIDE COUNTER BALANCED BACKDRAFT DAMPER IN SUPPLY DUCT. POSITION EVAPORATIVE COOLER WALL SWITCH. SEE CONTROLS DETAIL. TIE EXISTING EVAPORATIVE COOLER INTO NEW DDC CONTROLS. SEE DETAIL. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 $ TEACHERS WORK ROOM COMPUTER LAB A B OFFICE 0 0 0 $ $ $ $ $ $ OFFICE AFTER HOURS $ (TYP) 0"X0"UP D- D- CAFETERIA 0"X0"UP $ UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 A 7A I:\JOBS0\0\CAD\CUM0B.dwg, /0/07 :9: PM, taargyle D- 0"X0"UP D- 0"X0"UP D- 0"X0"UP MECHANICAL PLAN SCALE: /8"='0". NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, D- 0"X0"UP COAT ROOM MARCH, 07 0 I:\JOBS0\0\CAD\CUM0B.DWG MECHANICAL PLAN M0B

KEYED NOTES FOR SHEET M0C EXISTING EVAPORATIVE COOLER DIFFUSER. NEW BMS CONTROLS CABINET, DIVISION TO PROVIDE 0 VOLT CIRCUIT. PROVIDE COUNTER BALANCED BACKDRAFT DAMPER IN SUPPLY DUCT. POSITION EVAPORATIVE COOLER WALL SWITCH. SEE CONTROLS DETAIL. ADD DDC CONTROLS TO EXISTING EVAPORATIVE COOLER. SEE DETAIL. WIRE EXISTING POSITION WALL SWITCH TO NEW EVAPORATIVE COOLER. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 0 D- 0 0"X0"UP $ 9 D- 0"X0"UP D- 0"X0"UP D- 0"X0"UP 8 $ $ $ $ $ D- 0"X0"UP D- 0"X0"UP $ $ $ D- 0"X0"UP SERVER ROOM 0 0 7 (TYP) UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 I:\JOBS0\0\CAD\CUM0C.dwg, /0/07 :9: PM, taargyle MECHANICAL PLAN SCALE: /8"='0" $. NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, MARCH, 07 0 I:\JOBS0\0\CAD\CUM0C.DWG MECHANICAL PLAN M0C

KEYED NOTES FOR SHEET M0A EXISTING EVAPORATIVE COOLER. EXISTING SKYLIGHT (TYPICAL). EXISTING ROOF DRAIN (TYPICAL). EXISTING ROOFTOP UNIT. INSTALL NEW EVAPORATIVE COOLER AND ROOF CURB. CONNECT TO EXISTING DUCTWORK AND TRANSITION TO NEW COOLER IF REQUIRED. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 I:\JOBS0\0\CAD\CUM0A.dwg, /0/07 :9:8 PM, taargyle EC- EC- EC- EC- EC- MECHANICAL ROOF PLAN SCALE: /8"='0". NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 MARCH, 07 0 I:\JOBS0\0\CAD\CUM0A.DWG MECHANICAL ROOF PLAN M0A

KEYED NOTES FOR SHEET M0B EXISTING EVAPORATIVE COOLER. EXISTING SKYLIGHT (TYPICAL). EXISTING ROOF DRAIN (TYPICAL). EXISTING ROOFTOP UNIT. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 EC- EC- UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 I:\JOBS0\0\CAD\CUM0B.dwg, /0/07 :9:0 PM, taargyle EC- EC- SCALE: /8"='0" EC- MECHANICAL ROOF PLAN. NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, EC- MARCH, 07 0 I:\JOBS0\0\CAD\CUM0B.DWG MECHANICAL ROOF PLAN M0B

KEYED NOTES FOR SHEET M0C EXISTING EVAPORATIVE COOLER. EXISTING SKYLIGHT (TYPICAL). EXISTING ROOF DRAIN (TYPICAL). INSTALL NEW EVAPORATIVE COOLER AND ROOF CURB. CONNECT TO EXISTING DUCTWORK AND TRANSITION TO NEW COOLER IF REQUIRED. 7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 EC- EC- EC- EC- EC- EC- EC- EC- EC- UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 I:\JOBS0\0\CAD\CUM0C.dwg, /0/07 :9: PM, taargyle MECHANICAL ROOF REMODEL PLAN SCALE: /8"='0". NEW EVAPORATIVE COOLER DIFFUSER SHALL BE INSTALLED. SOME CEILING ACCESS DOORS EXIST IN EXISTING HARD. PATCH ALL HOLES OR DAMAGE TO EXISTING WALLS, MARCH, 07 0 I:\JOBS0\0\CAD\CUM0C.DWG MECHANICAL ROOF REMODEL PLAN AREA C M0C

7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 WALL SWITCH FOR EVAPORATIVE COOLER 0 VAC BY DIV. RELAY BACNET COMMUNICATION CURRENT SENSOR AI DO ENABLE / DISABLE RELAY 0 VAC SCALE: N.T.S. SUPPLY DIFFUSER DDC CONTROLLER (QTY. AS NEEDED) EVAPORATIVE COOLER CONTROL DIAGRAM TYPICAL EVAPORATIVE COOLER SEQUENCE OF OPERATIONS: (TYPICAL). THE FACTORY CONTROLS SYSTEM SHALL PROVIDE THE USER WITH POSITION SWITCH (OFF, PUMP, LOW VENT, HIGH VENT, LOW COOL & HIGH COOL).. THE BAS SYSTEM SHALL DETERMINE THE OCCUPIED AND UNOCCUPIED MODE TIME FRAMES OF THE SPACE(S) BEING SERVED. WHEN IN THE OCCUPIED MODE, THE EVAPORATIVE COOLER SERVING THE SPACE SHALL BE ENABLED FOR THE USE BY THE USER. EVAPORATIVE COOLER UPGRADE - PROJECT # 0 NORTH 0 WEST SUNSET, UT 80 X TREATED WOOD ROOF CURB X FASTENED TO X AND EXISTING ROOF DECKING " MIN. GA GALVANIZED FULLY SOLDERED METAL FLASHING FASTENED TO ROOF CURB NEW ROOF MEMBRANE FULLY ADHERE TO CURB AND EXISTING ROOF MEMBRANE X CANT STRIP FASTENED TO X EXISTING ROOF MEMBRANE TIE NEW ROOF MEMBRANE INTO EXISTING ROOF MEMBRANE IN THIS LOCATION MARCH, 07 0 I:\JOBS0\0\CAD\CUM0.DWG I:\JOBS0\0\CAD\CUM0.dwg, /0/07 :9: PM, taargyle EVAPORATIVE COOLER ROOF CURB DETAIL SCALE: NONE EXISTING ROOF INSULATION EXISTING ROOF DECKING MECHANICAL SCHEDULES, CONTROLS AND DETAILS M0

7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 South State Street Salt Lake City, Utah 8 P:80..9 F:80..0 BNAwww.bnaconsulting.com CONSULTING SALT LAKE ST.GEORGE 07 BNACONSULTING 0 NORTH 0 WEST SUNSET, UT 80 MARCH, 07 0 708 BNA SV SYMBOLS, SCHEDULES AND NOTES E0.

7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 South State Street Salt Lake City, Utah 8 P:80..9 F:80..0 BNAwww.bnaconsulting.com CONSULTING SALT LAKE ST.GEORGE 07 BNACONSULTING ETERIA WALK-IN COOLER WALK-IN COOLER OFFICE FAN ROOM ELEC. ROOM S COMP. LAB BREAKROOM TEACHERS WORK ROOM ADMINISTRATION 0 NORTH 0 WEST SUNSET, UT 80 SERVING HEALTH HEALTH S MARCH, 07 0 708 BNA SV COAT ROOM ELECTRICAL PLAN E.

7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 South State Street Salt Lake City, Utah 8 P:80..9 F:80..0 BNAwww.bnaconsulting.com CONSULTING SALT LAKE ST.GEORGE 07 BNACONSULTING OFFICE AFTER HOURS S TEACHERS WORK ROOM COMPUTER LAB S S S S S S OFFICE S CAFETERIA S 0 NORTH 0 WEST SUNSET, UT 80 COAT ROOM MARCH, 07 0 708 BNA SV ELECTRICAL PLAN E.

7 WEST 00 SOUTH SUITE #0 BOUNTIFUL, UTAH 800 PHONE: (80) 9-999 FAX: (80) 9-999 South State Street Salt Lake City, Utah 8 P:80..9 F:80..0 BNAwww.bnaconsulting.com CONSULTING SALT LAKE ST.GEORGE 07 BNACONSULTING S S S S S S S S S 0 NORTH 0 WEST SUNSET, UT 80 SERVER ROOM S MARCH, 07 0 708 BNA SV ELECTRICAL PLAN E.