Hand washing sink. 3-Comp Sink Shelving. SS Bussing table. Dishwasher. Store room. Door. Door. Roll up door

Similar documents
K-400 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR DISHWASHERS

K-66 SERIES. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

K-86 SERIES. Exclusive Features: Standard Features: ENERGY STAR Qualified. Options: Models:

K-64 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR DISHWASHERS

K-44 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

K-76 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

K-66 SERIES HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR WAREWASHERS. Standard Features: Exclusive Features: Options: Models:

K-86 SERIES HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR WAREWASHERS. Standard Features: Exclusive Features: Options: Models:

B-US 281 LPW HOT WATER SANITIZING FLIGHT-TYPE WAREWASHERS. Standard Features: Options:

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

The clean solution HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR WAREWASHERS K-M54 SERIES. Special Features: Standard Features: Optional Features:

The clean solution HOT WATER SANITIZING MULTIPLE-TANK FLIGHT TYPE WAREWASHERS B-M74 SERIES. Special Features: Standard Features: Optional Features:

DV The clean solution. Special Features: Standard Features: Options: HOT WATER SANITIZING DOOR-TYPE DISHWASHER

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

02/18/2018. Project: VB Jamestown Elementary, Guilford County NC 108 POTTER DRIVE JAMESTOWN, NC

Models. Options. Standard Features. LoH 2 O

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

FT1000 FLIGHT-TYPE DISHWASHER

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

FT1000S BASE FLIGHT-TYPE DISHWASHER

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

CL64T INDUSTRIAL TOTE WASHER

FT900BD FLIGHT-TYPE DISHWASHER

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

Outstanding Performance; Application Flexibility

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

Standard Features. Performance/Capacities

C44A/C44AW DISHWASHER

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

FT900 FLIGHT-TYPE DISHWASHER

ThermoSaver TM Hot Gas Defrost System

commercial refrigeration products

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

VENTLESS DOOR-TYPE DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

Air-Cooled Condensing Units with Compact Screw Compressors

CLPS86eN-BAS DISHWASHER

CL44eN-BAS DISHWASHER

roof finish is 26 gauge acrylic coated stucco galvanized steel.080 textured aluminum interior floor finish, where required

Wall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations. KaTom Restaurant Supply, Inc.

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

K Tronic Series Installation and Start Up Checkout Procedure.

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Conveyor. AJ-44 Vision Series. Standard Features. Power/Connections. Performance/Capacities

CL64eN-BAS DISHWASHER

FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine FT SERIES FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER

10-Bilt. Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS

LOW PROFILE UNIT COOLER

GIRTON CABINET WASHER MODEL 794A

Super-Flo Low Profile Unit Cooler

FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine. FT SERIES FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER

MEIKO Undercounter Dish and Glass Washing Machine. Spare Parts List 208V/230V 1/3-PHASE 60 HZ

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

Wall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations

High Profile Evaporator

CLCS76eN-BAS DISHWASHER

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

H O B A R T F T F L I G H T - T Y P E W A R E W A S H E R. Energy efficient. Water efficient. Cleaning efficient. So you re efficient.

CLCS76eN-EGR ENERGY RECOVERY DISHWASHER

FT1000S ENERGY RECOVERY STEAM Flight-Type Dishwashing Machine FT SERIES FT1000S ENERGY RECOVERY STEAM STANDARD FEATURES SPECIFIER STATEMENT

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

ThermoSaver TM Hot Gas Defrost System

Submittal Summary Page

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Installation Manual. PRO Series Ventless Heat Recovery Rack Conveyor Dishwashers LISTED.

EUCCW SERIES. EUCCW4, EUCCW6 and EUCCW8 Upright 29 Conveyor Dual Rinse Dishwashing Machine. Champion, an Ali Group Company

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

CLPS66eN-EGR ENERGY RECOVERY/CLPS66eN-ADV DISHWASHER

TPLP Pre-Assembled. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION. Air & Electric Defrost

CL64eN-EGR ENERGY RECOVERY/CL64eN-ADV DISHWASHER

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES

Device and Duo Rinse r/hr. Warewashing

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

INSTALLATION INSTRUCTIONS

E1 Electrical Fundamentals. # 4 - Symbols and Wiring Diagrams

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

MACH N-407 Heat Pump Air-Cooled Chiller

LOW PROFILE UNIT COOLER

RGE 13 A T - 1 A

Advance Release September 2009

STERO SCT-94SC/108SC/120SC CONVEYOR SERIES

MODELS B1PA024, 030 AND 036

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Model 80 DRHDPW 44 Single Tank with 36 Heavy Duty Prewash High Temperature Rack Conveyor Dishwashing Machine with

Canning Shed/Facility Equipment Specifications

TPLP PRE-ASSEMBLED LOW PROFILE EVAPORATORS

EUCC SERIES Upright 24" Conveyor Dual Rinse Dishwashing Machine

84 Series 84, 106 PW, 110 FFPW, 120 HDPW High-Temperature Rack Conveyor Dishwashing Machine

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

MODEL CMA-180UC INSTALLATION & OPERATION Rev 1.17A

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Transcription:

oor Roll up door tore room oor ishwasher Bussing Hand washing sink 3-omp ink helving

helving helving ink offee station offee Brewer Tea Brewer Hand washing sink unnnage Racks Freezer helving Ice Machines oor Roll up door

Quote No: 13213-1-0-LJI Job Name: Last Update: laura 03/20/2013 ate: 03/20/2013 PV: 12/20/2012(TF) To: Attn: enterplate, cott Middleton Refrigerated tructures ivision Morehead ity, N 28557 (800) 242-2559 From: pokane onvention enter Laura Ibbitson wanson-girard & Assoc 9800 outhern Pines Blvd, uite L harlotte, nc 28273 Phone: (704)521-8811 Fax: (704)521-8801 Box hape Indoor tructure Bally Prefabricated Exterior imensions: 18'-3 ½" Length x 8'-8 ½" idth x 8'-6" Height 1 ompartment. ith Floor eiling: ingle pan Panel Thickness: 4" Exterior Vertical Used (7'-10") with 4" Floor, 4" eiling NF APPROVE etails on Following Page(s) NOTE: Freight shown is an estimate based on current published rates. A fuel surcharge will be added and changes continuously. alk-in Price: Refrigeration Price: $13,513.09 $4,373.65 Total Price (FOB Plant) (Less Refrig.arranties) $17,886.74 Net Estimated Freight: $2,553.81 Optional arranties: (not included in Total Price) 5 Year ompressor Only arranty(s): $200.00 Net 5 Yr. ystem Parts ith 1 Yr. Labor: $514.50 Net Payment terms and conditions are available upon request. This quotation was based on information supplied to us which may or may not have been complete. ustomer is responsible for reviewing this quotation for exclusions, deviations, and any improper information supplied to us. ignature: ate: Laura Ibbitson e are not responsible for the selection or recommendation of the panel finish for any building or walk-in application. NOTE: Quoting Bally standard specifications, sizes, and finishes. This quotation is good through 06/18/2013 Bally Refrigerated Boxes, Inc. is compliant with Federal Energy Independence and ecurity Act of 2007 (Public Law 110-140) Title III; ection 312, regarding alk-in oolers and alk-in Freezers. Page 1 of 4

Refrigerated tructures ivision Morehead ity, N 28557 (800) 242-2559 Quote No: 13213-1-0-LJI Job Name: pokane onvention enter Last Update: laura 03/20/2013 ate: 03/20/2013 PV: 12/20/2012(TF) To: enterplate, From: Laura Ibbitson wanson-girard & Assoc 9800 outhern Pines Blvd, uite L harlotte, nc 28273 Attn: cott Middleton Phone: (704)521-8811 Fax: (704)521-8801 Indoor tructure Bally Prefabricated Exterior imensions: 18'-3 ½" Length x 8'-8 ½" idth x 8'-6" Height 1 ompartment. ith Floor eiling: ingle pan Panel Thickness: 4" Exterior Vertical Used (7'-10") with 4" Floor, 4" eiling NF APPROVE etails and specifications for Quote No: omments: Freezer 13213-1-0-LJI Base Finish: Refrigeration is calculated for storage only at a box temperature of 10 F. with a condensing unit ambient of 95 F. Vertical and eiling Panels: Embossed Galvalume (26 GA) pecial Finishes: Interior Floor - tainless teel Rigidized (16 ga) oors/openings: 1 48" x 78" Hinged oor in a 69" x 94" Panel oors accessories: 1 Int.tainless teel Ramp (42-48" oor) 1 uper oor 42-60" ide, 36" high Accessories and Extras: 1 Bally tandard Pressure Relief Port (< 400 sq/ft) 4 Fluorescent Light(s) (2) Tube 4' Long w/ Bulbs 1 Reinforce Interior Ramp 171 /F 3/4" Plywood Foamed in Panel 36 /F Emboss Galvalume (losure Metal) Refrigeration: 1 BEHA 030 L6 HT3BF (208-230/3/60) 3 HP A/ Herm Outdoor Low Unit (R404) 11600 BTU 1 BLP 314LE-V-2BE 14000 (208-230/1/60) Estimated hipping: eight: 4,560.37 estination: pokane, A 99201 Page 2 of 4

Refrigerated tructures ivision Morehead ity, N 28557 (800) 242-2559 Quote No: 13213-1-0-LJI Job Name: pokane onvention enter Last Update: laura 03/20/2013 ate: 03/20/2013 PV: 12/20/2012(TF) To: enterplate, From: Laura Ibbitson wanson-girard & Assoc 9800 outhern Pines Blvd, uite L harlotte, nc 28273 Attn: cott Middleton Phone: (704)521-8811 Fax: (704)521-8801 hipping alculation: $0.56 x 4,560.37# = 2553.81 Page 3 of 4

Refrigerated tructures ivision Morehead ity, N 28557 (800) 242-2559 Quote No: 13213-1-0-LJI Job Name: pokane onvention enter Last Update: laura 03/20/2013 ate: 03/20/2013 PV: 12/20/2012(TF) To: enterplate, From: Laura Ibbitson wanson-girard & Assoc 9800 outhern Pines Blvd, uite L harlotte, nc 28273 Attn: cott Middleton Phone: (704)521-8811 Fax: (704)521-8801 eviations (Alternates, Remarks, larifications, Etc.): Quoting Bally tandard Hermetic Pre-assembled Remote Refrigeration. Bally does not recommend the use of heavy carts, pallet jacks or fork lifts on top of the floors. arranty for floors subjected to this type of use would not be covered by Bally. Exclusions (Items Not upplied by Bally): helving, Racks, Interior Accessories Labor on arranties Alarm ystems upervision Tubing, iring for Rfg. Equipment ompressor Rack aulking and ealants Refrigeration ystems Refrigeration Accessories losure Panel and Trim leeves, Penetrations, Escutcheon Plates Floor Insulation and Vapor Barrier ancelled Orders: ancelled unshipped standard walk-ins will be charged a 30% restocking fee plus the cost of special panels. ancelled refrigeration systems will be charged a 30% restocking fee and the cost of any freight accrued. Buy-out items will be charged a 25% restocking fee plus any freight accrued. Agency Ratings: Bally units comply or surpass applicable Flame pread-25, UL, UL 723, & NF standards in a manner conforming to ATM E-84, and Factory Mutual standards. Quotation Limitations: This quotation was based upon the specifications given to Bally which may possibly be incomplete. Bally is not responsible for items missing from the quotation due to incomplete or excluded items in the specifications received from the customer. The customer is responsible for reviewing the quotation for omissions or deviations from the specifications given to Bally. All portions of the quotation are subject to revision upon receipt of detailed specifications or if changes are made following the delivery of the original quotation. Panel onstruction: Bally Panels are manufactured with environmentally friendly HF 245-FA polyurethane foam. This polyurethane foam offers the highest thermal insulation value and the most energy efficiency per cubic inch in comparison to similar foams. It has a zero Ozone epletion Potential (OP) and a low Global arming Potential (GP). It is not considered a Volatile Organic ompound (VO) in the U. tandard 4 Bally panels meet the 2009 Federal Energy tandards. Refrigerants: Unless otherwise specified, refrigeration systems are quoted with environmentally friendly HF R404A refrigerant. It has a zero Ozone epletion Potential (OP). The EPA lists it as an accep substitute for ozone-depleting substances. Automatic oor losers: Bally includes automatic door closers and spring loaded hinges on all doors 42 wide and smaller as a standard feature with no additional charge that meet the 2009 Federal Energy tandards. Motors: Bally units are quoted with E and P motors in compliance with federal energy standards, for increased energy savings. Lighting: Bally units are quoted with lighting in compliance with federal Energy tandards for increased energy savings. Optional Features: Bally offers additional optional energy-saving features such as alk-in Alarm & Light Management systems that comply or surpass the 2009 Federal energy regulations. Page 4 of 4

NATIONAL REFRIGERATION AN AIR ONITIONING ANAA ORP. 159 ROY BLV, PO BOX 2020 BRANTFOR, ON ANAA N3T 5Y6 BEHA030L6-HT3B EH-LINE HERMETI ONENING UNIT UBMITTE BY : Laura Ibbitson PURHAER : PROJET : POKANE ONVENTION ENTER ATE : 20 Mar 2013 ORER # : 03000.57745.00469-A00 ITEM # : 1 QUOTE # : Q20LLIA-A I # : PURHAER' PO # : TAGGING : opper tubing secured with cushion clamps rankcase heater Flooded head pressure control (non adjus) High efficiency enhanced copper tube and aluminium fin coil design MOEL FEATURE High efficiency P fan motor with internal overload protection Outdoor weather-resistant housing with removable hood Pre-formed piping Receiver with fusible plug and outlet valve uction ervice valve Units are shipped with Helium holding charge eatherproof electrical control box with compressor contactor and fused control circuit Adjus low pressure control with flex hose / fixed high pressure control PRE-ENGINEERE OPTION PAKAGE A - T B E 1 F G H J EFROT FUING - HO ET QTY Up to 30 Amps 35 Amps to 60 Amps ELETRI EFROT KIT (TIMELOK INL.) 1 Up to 40A Htrs, 30A Fans 1 Evap Up to 60A Htrs, 30A Fans 1 Evap Up to 40A Htrs, 30A Fans 2 Evap Up to 60A Htrs, 30A Fans 2 Evap Up to 60A Htrs, 40A Fans 3 Evap Up to 80A Htrs, 50A Fans 3 Evap 115V ontrol ircuit 30A ontactor 40A ontactor 60A ontactor AJUTABLE PREURE ONTROL anfoss ual with flex hose Johnson ual with flex hose eparate High/Low with flex hose MOEL OPTION ( * = hipped Loose ) BALL VALVE *Liquid Line *uction Line ABINET FINIH Painted Grey APAITY ONTROL BYPA HG Bypass to Evaporator HG Bypass to uction Line ompressor ircuit Breaker ompressor Time elay Relay ONENING UNIT PRION PAKAGE Tamper Proof crews rankcase Pressure Regulator ischarge Air Hood IONNET ITH Fused Non-Fused E ondenser Fan Motor + peed ontroller Extended 4-Year ompressor arranty Extended Leg Kit OIL OATING ElectroFin oating Heresite oating FIN AN MATERIAL Gold oat Fins opper Fins Hail Guard for ondenser Heated and Insulated Receiver Hoffmann Fan peed ontrol Insulated uction Line LIQUI LINE FILTER + IGHT GLA 1 ealed Liquid Line Lock-Out Relay LIQUI LINE OLENOI VALVE *tandard 230V oil *tandard 115V oil Oversized Receiver PHAE / VOLTAGE MONITOR 3-Lead Pump own Toggle witch Receiver Inlet Ball Valve ingle Point Electrical tainless teel Housing UTION AUMULATOR ith Heat Exchanger ithout Heat Exchanger UTION FILTER ealed Type TIME LOK Paragon 8145 tyle *230V Paragon 8145 tyle *115V Paragon 8145 tyle Two Valve Adj Flooded Head Pressure ontrol ind Guard QuickVac Valves VOLTAGE YTEM REFRIGERANT RATING UTION TEMP AMBIENT TEMP APAITY 208-230/3/60 R404A 3Hp -18.6 ºF 95.0 ºF 12,070 BTUH FAN OMPREOR IRUIT TOTAL QTY POER FLA/FAN TYPE QTY RLA LRA AMP ATT MA MOP 1 1.1 F12K6ETF5 1 11 85 12.1 14.9 25 im A im B 19 7/8 in 36 3/8 in imensions shown are for standard unit less options. ee certified drawing for more details. im 30 3/8 in * Indicates Option Is hipped Loose im 4 in MA.. Minimum ircuit Ampacity LIQUI 1/2 in MOP.. Maximum Overcurrent Protection UTION 7/8 in MA & MOP hown Here are reflective of the condensing unit ONLY. ingle point connections OUN - ILL show different on dataplate. EIGHT 292 lb APAITY 14 lb APPROVAL APPROVE BY : ATE : Approval of this drawing signifies that the equipment is accep under the provision of the job specifications. Any change made hereon by any person whomsoever subject to acceptance by NATIONAL REFRIGERATION at its home office. PAGE 1 OF 4

NATIONAL REFRIGERATION AN AIR ONITIONING ANAA ORP. 159 ROY BLV, PO BOX 2020 BRANTFOR, ON ANAA N3T 5Y6 NATIONAL REFRIGERATION will furnish equipment in accordance with this drawing and specifications, and subject to its published warranty. Approval of this drawing signifies that the equipment is accep under the provision of the job specifications. Any change made hereon by any person whomsoever subject to acceptance by NATIONAL REFRIGERATION at its home office. imensions shown are for standard unit less options. IMENION IMENION A 19 7/8 in IMENION B 36 3/8 in IMENION 30 3/8 in IMENION 4 in IMENION E IMENION F IMENION G 0 in IMENION H Order Item No: 1 BEHA030L6-HT3B EH-LINE HERMETI ONENING UNIT ATE : 20 Mar 2013 PURHAER : PROJET : POKANE ONVENTION ENTER UBMITTE BY : Laura Ibbitson ONNETION LIQUI UTION RAIN ATER IHARGE PAN LOOP HOT GA IE PORT HOT GA INLET HOT GA OUTLET OTHER HIPPING EIGHT APAITY 1/2 in 7/8 in 292 lb 14 lb APPROVAL NOTE: PAGE 2 OF 4

NATIONAL REFRIGERATION AN AIR ONITIONING ANAA ORP. 159 ROY BLV, PO BOX 2020 LO PROFILE BRANTFOR, ON ANAA N3T 5Y6 EVAPORATOR PURHAER : UBMITTE BY : Laura Ibbitson PROJET : POKANE ONVENTION ENTER ATE : 20 Mar 2013 ORER # : 03000.57745.00469-A00 ITEM # : 2 QUOTE # : Q20LLIA-A I # : PURHAER' PO # : TAGGING : MOEL FEATURE 3/8" Tubing coil construction (reduces refrigerant operating charge) Factory installed solenoid valve wire harness Heavy gauge textured aluminum cabinet construction resists scratches/corrosion pacious piping end compartment allows for easy assembly Hinged drain pan with central universal drain connection (3/4" drain) Front access to spacious electrical and header compartments BLP314LE-2B_EM chrader connection on suction header Attractive and durable high density polyethylene fan guards Ultra efficient Electronically ommutated Motor (EM) EM with martpeed Technology High efficiency enhanced copper tube and aluminium fin coil design PRE-AEMBLE EVAP porlan TXV, LLV,T-stat 1 martvapii with porlan TXV & olvlv KE2 emand efrost w/porlan TXV KE2 emand efrost w/porlan EEV *KE2 emand efrost w/porlan TXV *KE2 emand efrost w/porlan EEV anfoss TXV, LLV, T-stat martvapii with anfoss TXV & olvlv Emerson TXV, LLV,T-stat KE2 emand efrost w/ke2 EEV *KE2 emand efrost w/ke2 EEV AJUTABLE T-TAT *Johnson A19AB-24 *Johnson A419AB-1 *aginomiya *anfoss Ranco F25 - Adjus T, Fixed F Aux ideport onnector ABINET FINIH Painted hite Painted Black tainless teel MOEL OPTION ( * = hipped Loose ) P ENOR oil Temp ensor Return Air Temp ensor uction Pressure Transducer EMAN EFROT ELETRONI ONTROLLER KE2 Therm - emand efrost *KE2 Therm - emand efrost ual ircuit EEV ENOR/TRANUER BRAN P/Emerson Other - pecify in Notes ELETRONI ONTROLLER 1 martvapii *porlan Kelvin II EEV ontroller *Emerson EEV ontroller *Other EEV ontroller- pecify MFR Model in Notes EVAPORATOR PRION PAKAGE Tamper Proof crews EXPANION VALVE 1 porlan TXV anfoss TXV porlan EEV (less sens+trans) Emerson TXV OIL OATING ElectroFin oating Heresite oating FIN AN MATERIAL opper Fins Insulated rain Pan KE2 THERM *Router #20184 *8 Port witch #20166 *AT5e hielded able - 50ft w/connectors *ontactor Kit - 50A #20217 *Liquid / uction Heat Exchanger LIQUI LINE OLENOI VALVE anfoss 1 porlan Emerson Nitrogen harged and ealed Room Thermostat *Room Thermostat ire Fan Guards VOLTAGE YTEM REFRIGERANT AIR FLO EVAP. TEMP BOX TEMP APAITY 208-230/1/60 R404A 2860 FM -18.6 ºF -10.0 ºF 12,138 BTUH FAN HEATER IRUIT TOTAL QTY POER FLA/FAN TYPE QTY AMP AMP ATT MA MOP 3 0.07HP 0.6 1.8 180 2 15 EFROT HTR 11.9 2730 14.8 15 im A im B 62 1/4 in 49 1/4 in imensions shown are for standard unit less options. ee certified drawing for more details. im * Indicates Option Is hipped Loose im MA.. Minimum ircuit Ampacity ITRIBUTOR 1/2 in MOP.. Maximum Overcurrent Protection UTION 7/8 in OUN - EIGHT 109 lb HARGE 3 lb APPROVAL APPROVE BY : ATE : Approval of this drawing signifies that the equipment is accep under the provision of the job specifications. Any change made hereon by any person whomsoever subject to acceptance by NATIONAL REFRIGERATION at its home office. PAGE 3 OF 4

NATIONAL REFRIGERATION AN AIR ONITIONING ANAA ORP. 159 ROY BLV, PO BOX 2020 BRANTFOR, ON ANAA N3T 5Y6 NATIONAL REFRIGERATION will furnish equipment in accordance with this drawing and specifications, and subject to its published warranty. Approval of this drawing signifies that the equipment is accep under the provision of the job specifications. Any change made hereon by any person whomsoever subject to acceptance by NATIONAL REFRIGERATION at its home office. imensions shown are for standard unit less options. IMENION IMENION A 62 1/4 in IMENION B 49 1/4 in IMENION IMENION IMENION E IMENION F IMENION G 0 in IMENION H Order Item No: 2 BLP314LE-2B_EM LO PROFILE EVAPORATOR ATE : 20 Mar 2013 PURHAER : PROJET : POKANE ONVENTION ENTER UBMITTE BY : Laura Ibbitson ONNETION ITRIBUTOR UTION RAIN ATER IHARGE PAN LOOP HOT GA IE PORT HOT GA INLET HOT GA OUTLET OTHER HIPPING EIGHT HARGE 1/2 in 7/8 in 3/4 in 109 lb 3 lb APPROVAL NOTE: PAGE 4 OF 4

Electric efrost Made marter and impler It s mart Electronically ontrols: Box Temperature efrost Initiation efrost Termination Fan elay It s imple 2 Pipes, 2 ires, It s one! Eliminates wiring back to condensing unit Factory Pre-set to suit most applications Extremely simple user interface martvap II TM ontroller replaces these components Time lock Room Thermostat efrost Termination/ Fan elay Thermostat efrost Heater ontactor efrost Heater Fusing Available for electric defrost single phase low profile evaporators, up to 25 Amp. maximum overcurrent protection. Available for air defrost single phase low profile evaporators. onsult factory for other applications

The Ultimate Electric efrost Unit ooler Bally Refrigeration has taken the concept of electronic controls and made it simple. martvap II TM is a simple control located in the evaporator that controls box temperature and all aspects of the electric defrost. Evaporator includes factory installed: elected Nozzle Thermostatic Expansion Valve olenoid Valve isconnect witch (optional) By eliminating the time clock and heater contactor usually located in the condensing unit, the martvap II TM makes wiring the refrigeration system a breeze. Also eliminating the thermostat, defrost termination switch and the fan delay switch, martvap II TM reduces costly component failures and simplifies field installation. PLU - as an electronic controller, martvap II TM allows for more accurate temperature control in the box. martvap II TM is field adjus for unique applications. 2 Pipes + 2 ires = imple Bally Refrigeration is a orld leader in the insulated panel industry, providing topnotch insulated panels for commercial and institutional use in walk-in coolers, walk-in freezers, refrigerated buildings, modular structures, blast chillers and mortuary coolers. Bally Refrigeration also offers a complete line of refrigeration superior products, ideal for fast-freezing or fresh product storage in warehouses, processing plants and supermarkets. ITRIBUTE BY: General ales, Parts & ervice Manufacturing & Engineering 135 Little Nine rive, Morehead ity, N 28557 252-240-2829 1-800-24-BALLY FAX: 252-240-0384 e-mail: ballysales@ballyrefboxes.com www.ballyrefboxes.com ue to Manufacturer s policy of continuous product improvement, the Manufacturer reserves the right to make changes without notice. Bulletin: B10-VII

K-200 ERIE HOT ATER ANITIZING INGLE-TANK RAK ONVEYOR IHAHER pecial Features: Low water consumption - 84.7 gallons (320.6 liters) per hour, 0.35 gallons (1.34 liters) per rack Pumped final rinse isolates the machine from variations in water line pressure, ensuring consistent washing results Pumped auxiliary rinse zone supplements the final rinse for improved rinsing and increased efficiency tandard aste Air Heat Recovery ystem reclaims the waste heat generated by the machine and uses it as free energy to preheat the incoming rinse water. This reduces energy consumption and allows hot water sanitization from a cold water supply (as low as 50 F / 10 ) tandard internal booster heater works with the aste Air Heat Recovery ystem for improved efficiency MIKE 3 electronic controller for fully automatic operation and advanced service diagnostics. Each zone activates water flow only when a rack enters the zone to conserve water, energy and detergent tandard Features: ENERGY TAR Qualified apacity 240 racks per hour ater consumption 0.35 gallons (1.34 liters) per rack All 304-series stainless steel construction ouble-wall insulated construction on front, top and back to improve operator safety, conserve heating energy, and reduce noise and heat loss into the dishroom Improved side-drive system ensures complete water coverage from every angle, even the bottom of the rack, while reducing jerking motions that can shift ware Large, easily-removed pan strainer(s). Models equipped with a prewash include a separate prewash scrap basket Large, insulated front door(s) are spring-loaded to open easily and TAY open, without latching omputer-positioned wash arms in easily-removed manifolds. Arms and manifolds are stainless steel, eliminating high-wear gaskets and O-rings. Nozzles are slotted and concave to minimize clogging Front-sloping tanks for easier cleaning. External, footlever drain system makes draining fast, safe and simple Powerful 3hp (2.2 k) wash pump is 50% more powerful than the industry standard for outstanding cleaning ability. Pump motor is vertically-mounted to be self-draining and easily removed for servicing ingle-point drain connection ingle-point powered vent connection Low-level heater protection K-200 K-200 P K-200 LP Options: Revolutionary blower drying system - uses only 3 k of heating energy. Available in two lengths for a variety of ware requirements Top hemical avings ystem - acts as a pre-rinse to reduce the need for pre-scrapping; processes water continuously through cyclone separators to remove food soil; reduces detergent consumption by up to 50% Hinged front access door(s) team coil or electric heating ingle-point electrical connection External vent fan control Table limit switch (end stop or whisker switch versions) irect drive sideloader 90 powered loader or unloader Flanged feet rain water tempering kit Models: K-200: 6 4-3/4 (1950mm) chamber with wash, auxiliary rinse and final rinse zones K-200 P: Adds 19-5/8 (500mm) prewash to K-200 configuration. Overall length 8 1/2 (2450mm) K-200 LP: Adds 31-1/2 (800mm) prewash to K-200 configuration. Overall length 9 1/4 (2750mm) K-200 eries Updated 9-12 MEIKO 1349 Heil Quaker Blvd. LaVergne, TN 37086 (800) 55-MEIKO FAX (615) 399-6620 www.meiko.us

K-200 eries, left-to-right - electric heat control panel 3 7/8" [100mm] splash guard [above ] Top option 9-7/8" [250mm] load section is replaced with Top section. Adds 1'-7 5/8" [500mm] to overall machine length. oor open 6'-6 1/2" [1994mm] 4'-10" [1474mm] 7 1/4" [184mm] 6 7/8" [174mm] drain handle 123 9 1/4" [235mm] 1'-1 1/4" [335mm] 4'-5 1/8" [1350mm] 6'-4 1/8" [1934mm] 6'-8 1/8" [2034mm] 2'-1 5/8" [650mm] 2'-5 1/2" [750mm] 2'-6 3/8" [770mm] 2'-2" [660mm] 1 5/8" [40mm] 2 3/4" [70mm] 1'-1" [330mm] 1'-1" [330mm] 1'-10 1/2" [570mm] 3 1/8" [80mm] 123 1'-4 1/8" [410mm] 9 5/8" [244mm] 1" [25mm] 1'-2 5/8" [370mm] 2'-6 1/4" [770mm] 1'-8 1/2" 1'-0 1/4" [310mm] [521mm] 4 3/8" [110mm] 3'-1" [940mm] Prewash (if present) 9 7/8" [250mm] 1'-7 5/8" 3'-11 1/4" [1200mm] [500mm] K-200: Table-to- 6'-4 3/4" [1950mm] K-200 P: Table-to- 8' 1/2" [2450mm] K-200 LP: Table-to- 9' 1/4" [2750mm] 8" [203mm] splash guard [above ] K-200 P: 1'-7 5/8" [500mm] K-200 LP: 2'-7 1/2" [800mm] Horizontal clearance 1'-8 1/8" [510mm] Blower dryer option Blower dryer is at unload end of machine. plash guard is not used. Note addition of one terminal block for blower dryer heating elements. No splash guard above All dimensions from floor +/- 1/2" (13mm) due to adjus feet. 1-3 Vertical clearance 1'-6" [458mm] 4 3/4" [120mm] 4 4 7/8" [125mm] 10 3/8" [264mm] tandard dryer: Adds 1'-11 5/8" [600mm] Extended dryer: Adds 2' 11-1/2" [900mm] 4 6'-4 1/8" [1934mm] K-200 eries Updated 9-12 MEIKO 1349 Heil Quaker Blvd. LaVergne, TN 37086 (800) 55-MEIKO FAX (615) 399-6620 www.meiko.us

K-200 eries, right-to-left - electric heat 3 7/8" [100mm] splash guard [above ] control panel Top option 9-7/8" [250mm] load section is replaced with Top section. Adds 1'-7 5/8" [500mm] to overall machine length. 6'-8 1/8" [2034mm] 6'-4 1/8" [1934mm] 4'-5 1/8" [1350mm] 1'-1 1/4" [335mm] 9 1/4" [235mm] 123 drain handle 6 7/8" [174mm] 7 1/4" [184mm] 4'-10" [1474mm] oor open 6'-6 1/2" [1994mm] 2'-1 5/8" [650mm] 2'-5 1/2" [750mm] 3'-1" [940mm] 1'-0 1/4" [310mm] 1'-8 1/2" 4 3/8" [110mm] [521mm] 2'-6 1/4" [770mm] 1'-2 5/8" [370mm] 1'-4 1/8" [410mm] 9 5/8" [244mm] 1" [25mm] 123 3 1/8" [80mm] 1'-10 1/2" [570mm] 1'-1" [330mm] 1'-1" [330mm] 2'-2" [660mm] 1 5/8" [40mm] 2 3/4" [70mm] 2'-6 3/8" [770mm] Prewash (if present) 8" [203mm] splash guard [above ] Horizontal clearance 1'-8 1/8" [510mm] 1'-7 5/8" 3'-11 1/4" [1200mm] [500mm] K-200: Table-to- 6'-4 3/4" [1950mm] K-200 P: Table-to- 8' 1/2" [2450mm] K-200 LP: Table-to- 9' 1/4" [2750mm] Blower dryer option Blower dryer is at unload end of machine. plash guard is not used. Note addition of one terminal block for blower dryer heating elements. 9 7/8" [250mm] K-200 P: 1'-7 5/8" [500mm] K-200 LP: 2'-7 1/2" [800mm] No splash guard above All dimensions from floor +/- 1/2" (13mm) due to adjus feet. 1-3 Vertical clearance 1'-6" [458mm] 4 7/8" [125mm] 4 4 3/4" [120mm] 6'-4 1/8" [1934mm] 10 3/8" [264mm] 4 tandard dryer: Adds 1'-11 5/8" [600mm] Extended dryer: Adds 2' 11-1/2" [900mm] K-200 eries Updated 9-12 MEIKO 1349 Heil Quaker Blvd. LaVergne, TN 37086 (800) 55-MEIKO FAX (615) 399-6620 www.meiko.us

K-200 eries, left-to-right - steam heat control panel splash guard [above ] 3 7/8" [100mm] Top option 9-7/8" [250mm] load section is replaced with Top section. Adds 1'-7 5/8" [500mm] to overall machine length. oor open 6'-6 1/2" [1994mm] 4'-10" [1474mm] 7 1/4" [184mm] 6 7/8" [174mm] drain handle R 7 1/2" [190mm] 9 1/4" [235mm] 10 1/4" [260mm] 1'-1 1/4" [335mm] 4'-5 1/8" [1350mm] 6'-4 1/8" [1934mm] 6'-8 1/8" [2034mm] 2'-1 5/8" [650mm] 2'-5 1/2" [750mm] 2'-6 3/8" [770mm] 2'-2" [660mm] 1 5/8" [40mm] 2 3/4" [70mm] 1'-1" [330mm] 1'-1" [330mm] 1'-10 1/2" [570mm] 3 1/8" [80mm] R 1'-4 1/8" [410mm] 9 5/8" [244mm] 3 7/8" [100mm] 2 1/2" [65mm] 1" [25mm] 6 1/4" [160mm] 1'-2 5/8" [370mm] 2'-0 3/8" [620mm] 2'-6 1/4" [770mm] 1'-8 1/2" 1'-0 1/4" [310mm] [521mm] 4 3/8" [110mm] 3'-1" [940mm] Prewash (if present) 9 7/8" [250mm] All dimensions from floor +/- 1/2" (13mm) due to adjus feet. 1'-7 5/8" 3'-11 1/4" [1200mm] [500mm] K-200: Table-to- 6'-4 3/4" [1950mm] K-200 P: Table-to- 8' 1/2" [2450mm] K-200 LP: Table-to- 9' 1/4" [2750mm] Horizontal clearance 1'-8 1/8" [510mm] R Vertical clearance 1'-6" [458mm] 8" [203mm] splash guard [above ] Blower dryer option Blower dryer is at unload end of machine. plash guard is not used. Note different locations for steam supply line and condensate return connections. R tandard: 3'-1/4" [920mm] Extended: 4' [1220mm] tandard: 1'-3" [380mm] Extended: 2' 2-3/4' [680mm] 10 7/8" [275mm] 2'-0 3/8" [620mm] 9 5/8" [245mm] R K-200 P: 1'-7 5/8" [500mm] K-200 LP: 2'-7 1/2" [800mm] 9 1/4" [235mm] No splash guard above tandard dryer: Adds 1'-11 5/8" [600mm] Extended dryer: Adds 2' 11-1/2" [900mm] 6'-4 1/8" [1934mm] K-200 eries Updated 9-12 MEIKO 1349 Heil Quaker Blvd. LaVergne, TN 37086 (800) 55-MEIKO FAX (615) 399-6620 www.meiko.us

K-200 eries, right-to-left - steam heat 3 7/8" [100mm] splash guard [above ] control panel Top option 9-7/8" [250mm] load section is replaced with Top section. Adds 1'-7 5/8" [500mm] to overall machine length. 6'-8 1/8" [2034mm] 6'-4 1/8" [1934mm] 4'-5 1/8" [1350mm] 1'-1 1/4" [335mm] 10 1/4" [260mm] 9 1/4" [235mm] 7 1/2" [190mm] R drain handle 6 7/8" [174mm] 7 1/4" [184mm] 4'-10" [1474mm] oor open 6'-6 1/2" [1994mm] 2'-1 5/8" [650mm] 2'-5 1/2" [750mm] 3'-1" [940mm] 1'-0 1/4" [310mm] 1'-8 1/2" 4 3/8" [110mm] [521mm] 2'-6 1/4" [770mm] 2'-0 3/8" [620mm] 1'-2 5/8" [370mm] 6 1/4" [160mm] 1'-4 1/8" [410mm] 9 5/8" [244mm] 3 7/8" [100mm] 2 1/2" [65mm] 1" [25mm] R 3 1/8" [80mm] 1'-10 1/2" [570mm] 1'-1" [330mm] 1'-1" [330mm] 2'-2" [660mm] 1 5/8" [40mm] 2 3/4" [70mm] 2'-6 3/8" [770mm] Prewash (if present) All dimensions from floor +/- 1/2" (13mm) due to adjus feet. 8" [203mm] splash guard [above ] Horizontal clearance 1'-8 1/8" [510mm] 1'-7 5/8" 3'-11 1/4" [1200mm] [500mm] K-200: Table-to- 6'-4 3/4" [1950mm] K-200 P: Table-to- 8' 1/2" [2450mm] K-200 LP: Table-to- 9' 1/4" [2750mm] R Vertical clearance 1'-6" [458mm] 2'-0 3/8" [620mm] 9 7/8" [250mm] Blower dryer option Blower dryer is at unload end of machine. plash guard is not used. Note different locations for steam supply line and condensate return connections. tandard: 3'-1/4" [920mm] Extended: 4' [1220mm] tandard: 1'-3" [380mm] Extended: 2' 2-3/4' [680mm] 10 7/8" [275mm] R 6'-4 1/8" [1934mm] K-200 P: 1'-7 5/8" [500mm] K-200 LP: 2'-7 1/2" [800mm] No splash guard above 9 1/4" [235mm] tandard dryer: Adds 1'-11 5/8" [600mm] Extended dryer: Adds 2' 11-1/2" [900mm] 9 5/8" [245mm] R K-200 eries Updated 9-12 MEIKO 1349 Heil Quaker Blvd. LaVergne, TN 37086 (800) 55-MEIKO FAX (615) 399-6620 www.meiko.us

K-200 eries Utility onnections rain 2-15/16 (75mm) O vertical, gravity-fed drain outlet (HPE piping). Optional 3" NPT male adapter supplied. Recommend placement directly above 4 floor drain. Additional piping to drain (if so required) to be supplied by customer. onnection is 6-7/8" (174mm) AFF. If using optional 2 NPT adapter, connection is 5-5/8 (144mm) AFF. Refer to etail View: rain for suggested connection. Electrical connection(s) team-heated machines have a single electrical terminal block. Electrically-heated machines have three or four electrical terminal blocks: 1 - Motors and controls 2 - ash tank heaters 3 - Booster heaters 4 - Blower dryer heaters (if present) All connections are 4-wire with ground - no neutral. Incoming leads must be appropriately sized for electrical supply. Opening(s) in the machine for the supply lines are NOT provided and should be executed onsite using appropriate strain relief device(s). onnection for steam-heated machines, and terminal blocks 1-3 for electricallyheated machines, are 4 5-1/8 (1350mm)AFF. onnection at terminal block 4 for electrically-heated machines is 10-3/8" (264mm)AFF. Refer to utility chart on Page 7 for electrical load information. Vent connection Refer to etail View: Vent for suggested connection. The waste air connection must be corrosion-resistant and frost-free. In particular, provisions must be made to prevent air temperatures of 32 F (0 ) or colder from reaching the machine at any time. A provision for draining moisture from the waste air pipe is strongly recommended. 3 Machine exhaust, without blower dryer: 354 FM (602m h) 3 Machine exhaust, with blower dryer: 388 FM (651m h) 3 Additional room air recommended for indirect vent: 120 FM (170m h) R old water connection (final rinse) 3/4" NPT pipe connection is 1' 1-1/4" (335mm) AFF. Temperature cold as available (50 F / 10 optimum) onsumption 84.7 gals. (320.6 liters) per hour Recommended hardness 1-6 grains/u.. gal. arm water connection (fill) 3/4" NPT pipe connection is 9-1/4" (235mm) AFF. Temperature 110-140 F (43-60 ) Initial fill: - K-200-37.0 gals. (140 liters) - K-200 P - 52.8 gals. (200 liters) - K-200 LP - 60.7 gals. (230 liters) - Top option (if present) - add 10.6 gals (40 liters) Recommended hardness 1-6 grains/u.. gal. team connection (steam-heated machines) 2" NPT pipe connection Machines without blower dryer: pipe connection is 10-1/4" (260mm) AFF. Machines with blower dryer: pipe connection is 9-1/4" (235mm) AFF. 10-30 PI ONTANT steam pressure is REQUIRE. If pressure is above 30 PI, use of a regulator is REQUIRE (supplied by customer). The pipe connection does NOT reflect the steam line size from the boiler to the dishwasher. The necessary steam line sizing must be determined by the facility's steam engineer based on the pressure and volume requirements. onsumption 187 lbs. per hour (51k) ondensate return connection (steam-heated machines) 1" NPT pipe connection Machines without blower dryer: pipe connection is 7-1/2" (190mm) AFF. Machines with blower dryer: pipe connection is 9-5/8" (245mm) AFF. ondensate line MUT be pressure-free. rain onnection The machine is equipped with a 2-15/16" (75mm) O vertical, gravity-fed drain. If possible, the machine drain can simply be positioned directly above a 4" floor drain. If a floor drain is not in the correct location, or if local codes require a trap, a 2" indirect drain line may be attached using the supplied 2" NPT male adapter. hoose a piping material that: omplies with any applicable local and national codes Is rated for use with water temperatures up to 180 F/82 Is rated for 3-12 ph to accommodate detergents and rinse aid in the drain water 6-7/8" [174mm] 5-5/8" [144mm] Optional 2 NPT adapter Recommended Tabling onstruction Tabletop 34" (864mm) AFF Use silicone sealer between the and the machine to prevent leakage. 20-1/4" (515mm) recommended Table turndown flange 3/4" (19mm) max. Vent onnection FM ratings shown are recommended values only. Exhaust connection must be adequate for the exhaust air and comply with all applicable national and local codes. upplied with machine: Machine vent Vent collar. Attaches to top of machine at 4 positions ondensate drain tube By others: quare vent duct. leeves inside vent collar. Attaches 3 positions per side (12 total). Attachment hardware to comply with all applicable national and local code requirements. Vent duct (by others) 1' 4-7/8" (428mm) maximum duct size Vent collar (supplied) Machine exhaust vent Gap permits room air to enter vent. This is intended and must not be blocked. ondensate drain tube (supplied) Base of customersupplied vent duct to be 3-1/8" (79mm) from top of machine. 6' 4-1/8" (1934mm) AFF 6' 7-1/4" (2013mm) AFF K-200 eries Updated 9-12 MEIKO 1349 Heil Quaker Blvd. LaVergne, TN 37086 (800) 55-MEIKO FAX (615) 399-6620 www.meiko.us

K-200 eries Technical pecifications Operating apacities Racks per hour (NF rated)... 306 Racks per hour (standard)... 240 ishes per hour... 6,000 Glasses per hour... 8,640 onveyor pecifications onveyor belt speed (NF rated)... 8.51 feet/min. (2.59m/min.) onveyor belt speed (standard)... 6.67 feet/min. (2.03m/min.) Horizontal clearance... 1 8-1/8 (510mm) Vertical clearance... 1 6 (458mm) ater pecifications Minimum water temperatures: Prewash tank... No minimum - 110-140 F (43-60 ) typical ash tank... 160 F (72 ) Auxiliary rinse tank... 165 F (74 ) Final rinse... 180 F (82 ) Incoming water temperatures: Final rinse connection... old as available (50 F / 10 optimum) Tank fill connection... 110-140 F (43-60 ) Initial fill K-200... 37.0 gals. (140 liters) K-200 P... 52.8 gals. (200 liters) K-200 LP... 60.7 gals. (230 liters) Top option (all)... Add 10.6 gals. (40 liters) Venting pecifications Machine exhaust, without blower dryer... 354 FM (602m 3 /h) Machine exhaust, with blower dryer... 383 FM (651m 3 /h) Additional room air recommended for indirect vent... 120 FM (170m 3 /h) Total Machines without blower dryer... 474 FM (806m 3 /h) Machines with blower dryer... 503 FM (855m 3 /h) Incoming water line size Final rinse connection... 3/4 NPT Fill connection... 3/4 NPT Recommended water hardness... 1-6 grains/u.. gal. onsumption at 100% capacity:... 84.7 gals. (320.6 liters)/hr. 0.35 gals. (1.34 liters)/rack Final rinse flow rate... 1.41 gals.(5.34 liters)/min. Machine Electrical pecifications 208 V/60 Hz/3 Ph 230 V/60 Hz/3 Ph 460 V/60 Hz/3 Ph TB1 TB2 TB3 TB4 TB1 TB2 TB3 TB4 TB1 TB2 TB3 TB4 K-200, electric tank heat... 18.3A 66.7A 75.0A -- 18.3A 58.2A 65.5A -- 8.4A 29.8A 33.7A -- K-200 P, electric tank heat... 20.9A 66.7A 75.0A -- 20.9A 58.2A 65.5A -- 9.8A 29.8A 33.7A -- K-200 LP, electric tank heat... 28.1A 66.7A 75.0A -- 28.1A 58.2A 65.5A -- 12.3A 29.8A 33.7A -- K-200, steam coil tank heat... 18.3A -- -- -- 18.3A -- -- -- 8.4A -- -- -- K-200 P, steam coil tank heat... 20.9A -- -- -- 20.9A -- -- -- 9.8A -- -- -- K-200 LP, steam coil tank heat... 28.1A -- -- -- 28.1A -- -- -- 12.3A -- -- -- Top... +3.9A -- -- -- +3.9A -- -- -- +2.3A -- -- -- Blower dryer, electrically-heated machines... -- -- -- 16.0A -- -- -- 14.0A -- -- -- 9.2A Blower dryer, steam coil-heated machines... +16.0A -- -- -- +14.0A -- -- -- +9.2A -- -- -- Motor ratings ash pump motor... 3.0 hp (2.2 k) Prewash pump motor, K-200 P only... 0.75 hp (0.55 k) Prewash pump motor, K-200 LP only... 3.0 hp (2.2 k) Auxiliary rinse pump motor... 0.75 hp (0.55 k) Final rinse pump motor... 0.75 hp (0.55 k) onveyor motor... 0.125 hp (0.09 k) Vent motor... 0.25 hp (0.19 k) Top pump motor (if equipped)... 1.0 hp (0.75 k) Blower dryer motor (if equipped)... 0.5 hp (0.37 k) Electric tank heater ratings (electrically-heated machines only) ash tank... 24 k Auxiliary rinse tank... 12 k Booster heater... 15 k Blower dryer heater... 3 k team pecifications (steam-heated units only) team line connection... 2 NPT ondensate return connection... 1 NPT team pressure... 10-29 psi (1-2 bars) team consumption... 187 lbs./hr. (51 k)* * NOTE: team-heated machines use electrically-heated blower dryer (3 k). Note: All specifications are subject to change without notice based on MEIKO s dedicated product improvement program. K-200 eries Updated 9-12 MEIKO 1349 Heil Quaker Blvd. LaVergne, TN 37086 (800) 55-MEIKO FAX (615) 399-6620 www.meiko.us

Equipment pecification: K-200 eries Rack onveyor - Item No. Item will be an NF and ETL-listed MEIKO: K-200 single tank, rack conveyor dishwasher, consisting of a wash zone with 3 hp pump motor, a pumped auxiliary rinse zone with 3/4 hp pump motor, and a pumped final rinse zone with 3/4 hp pump motor. Total length of the machine (-to-) will be 6 4-3/4 (1950mm). K-200 P single tank, rack conveyor dishwasher, consisting of a prewash compartment with a 3/4 hp pump motor, a wash compartment with a 3 hp pump motor, an auxiliary rinse compartment with a 3/4 hp pump motor, and a final rinse compartment with a 3/4 hp pump motor. Total length of the machine (-to-) will be 8 1/2 (2450mm). K-200 LP single tank, rack conveyor dishwasher, consisting of a prewash compartment with a 3 hp pump motor, a wash compartment with a 3 hp pump motor, an auxiliary rinse compartment with a 3/4 hp pump motor, and a final rinse compartment with a 3/4 hp pump motor. Total length of the machine (-to-) will be 9 1/4 (2750mm). Unit will utilize an internal booster heater to maintain a 180 F (82 ) minimum fresh water sanitizing rinse. Final rinse will be pumped for constant pressure and consistent rinsing results regardless of variation in water supply pressure. Unit will be NFrated with speed of 8.51 feet (2.59m) per minute. Unit will have a capacity of 240 racks per hour at a standard speed of 6.67 feet (2.03m) per minute. Unit will consume an NF-rated 84.7 U.. gals. (320.6 liters) per hour (0.35 U.. gals./1.34 liters per rack). Electrical characteristics: 208V/60 Hz/3 Ph 230V/60 Hz/3 Ph 460V/60 Hz/3 Ph ash tank temperature will be maintained at a minimum of 160 F (72 ). Tank heating will be accomplished by: Thermostatically-controlled electric heating elements Thermostatically-controlled stainless steel steam coils irection of conveyor travel will be: Right-to-Left Left-to-Right Unit will have the following standard features: apacity of 240 racks/hr. and 0.35 gals./rack Pumped final rinse for constant pressure and consistent rinsing results regardless of variations in water supply pressure Pumped auxiliary rinse zone to supplement the final rinse zone aste air heat recovery system to reclaim heat generated by the machine, using it as free energy to preheat the incoming rinse water ouble-wall, insulated construction Mike 3 electronic controller for fully automatic operation, variable conveyor speeds and advanced service diagnostics ash arm spray pattern that ensures effective coverage with varying angles and offset spray jets. lotted, concave wash nozzles and captivated end caps to promote easier cleaning Rack rail-mounted pawl bar drive system for smooth travel at high speeds and an unobstructed wash pattern Front sloping V-shaped wash tank for complete tank drainage, accessibility, and cleanability Low level heater protection Powerful 3 Hp wash pump motor is self-draining. Pump motor is internal and vertically installed for easy access and serviceablity Pump housing and impeller constructed of stainless steel ingle point drain connection ingle point ventilation connection Large front access door(s) can be opened with one hand and remain open without latches, aiding machine accessibility and cleanability Large, removable pan strainer(s) Models equipped with a prewash include a separate prewash scrap basket Unit will incorporate a MIKE 3 electronic control system that allows operation at 3 different conveyor speeds (maximum 6.57 feet/ 2.00m per minute, 240 racks per hour) while consuming an NF-rated 84.7 gals. (320.6 liters) of water per hour (0.35 gals./ 1.34 liters per rack). Unit will have the following optional features (check all that apply): Blower dryer system incorporating a single blower and 3k External vent fan control electric heaters for complete drying of all dishes, crockery Table limit switch and silverware Inline (whisker switch) style 1 11-5/8 (600mm) in length 2 11-3/8 (900mm) in length End stop style Top chemical savings system Flanged, bolt-down feet Hinged front access doors rain water tempering kit ingle-point electrical connection (electric heat only) 90 loader 90 power unloader K-200 eries Updated 9-12 MEIKO 1349 Heil Quaker Blvd. LaVergne, TN 37086 (800) 55-MEIKO FAX (615) 399-6620 www.meiko.us