gas monitoring system

Similar documents
portable gas analyser

portable gas analyser

ARG 1

Dräger X-am 7000 Multi-Gas Detection

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

P R O D U C T D ATA S H E E T

STATIONARY GAS ANALYSER

Gas Detection - GD -

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

SENSORS TRANSMITTERS. Process monitoring

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

P R O D U C T D ATA S H E E T

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

3SP_H2S_50 Package

IGD.CO.UK

Datalogging as standard

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Recent Improvements in Process GC Instrumentation

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

LOW NOx MODULATING GAS BURNERS

Dräger X-am 2500 Multi-Gas Detection

IAQ_100 C Package

APPLICATION DATA SHEET

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

A New Standard of Excellence

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

YOUR PARTNER IN FIRE & GAS DETECTION

Danfoss gas detection units

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

EL-USB-TC Thermocouple Data Logger with USB Interface

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Danfoss gas detection unit Type GD Heavy Duty

Chlorine gas leak detector

Carbon Monoxide CO Transmitter ADT-X3-1110

MicroRay IR-100 NEW. Inspection MicroRay IR-100

GAS DETECTION International Gas Detectors CH4 NO

Complete Gas Analysis

SERIES 47K GAS SENSOR

Two-Channel Gas Controller

Reproducible Climate...

SIMRAD GD10PE IR GAS DETECTOR

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Dräger Polytron 8000 Stationary gas detector (EC)

Your competent partner for measuring and services.

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

Danfoss gas detection units

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

intrinsically safe detector for hydrocarbon gases

3 3SP_O3_5 C Package

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN June 2004

Gas cooler series TC-Standard+

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

Complete packages with Software and Controller

SAFESITE Multi-Threat Detection System

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

APPLICATION DATA SHEET

HYGROPHIL H process hygrometer

CEM Istanbul - Turkey. True trace emission monitoring system

continuous emissions monitoring Combustion & Environmental Monitoring

Xgard. Fixed detectors For flammable, toxic or oxygen gases

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

ALTAIR 5X Multigas Detector Product Specification

P R O D U C T D ATA S H E E T

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Portable sample gas conditioning PCS.smart

VHP ARD BIODECONTAMINATION SYSTEM

Automatic Isokinetic Sampler ST5

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

APPLICATION DATA SHEET

Accessories, interfaces, sensors and complete solutions.

Dräger X-am 7000 Multi-Gas Detection

AS950 PORTABLE SAMPLERS

Zircomat Oxygen Analyzers

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Emission Monitoring System

Using the Model 1500 Portable Chilled Mirror Hygrometer

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Static differential pressure measuring instruments. Pascal-ST/Z. for low measurement ranges Pa oder Pa

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Transcription:

www..com gas monitoring system Photon S is s most recent and most sophisticated apparatus. It was created based on portable gas analyser - Photon. As its sucessor it also uses gas sensors as the main measurement method - it can have 9 of them supplemented with 4 EC cells. Along with power supply with control center and the most efficient gas dryer this modular CEMS system is available to mount in 19 open frame rack. It is tailored to a very specific demands of customer, what is possible thanks to lot of available extensions and add-ons. Manufactured according to the principle of ISO 10396. 1

CONTROL MODULE WITH POWER SUPPLY Contains PC 104 computer with Windows CE operating system, that supervises the work of entire CEMS 6,4 large, VGA (640 * 480) colorful display with touch-pad for results presentation and data input RS232C and Ethernet ports for communication with PC computer 3 bays for optional modules (available in the front or back of the analyser): Analogue outputs / inputs Digital outputs / inputs Relays output Wi-Fi communication adapter 2x USB port for peripherals (mice, keyboards) Calculation of combustion and related parameters Large SSD (Solid State Drive) for storage of measurement data GAS CONDITIONER MODULE Equipped with heated hose with heated gas filter Large surface, fibre glass filters for removing dust, salt particles and soot Several versions of driers available - combination of NAFION and Peltier exchangers For NO- measurement - water reservoir and peristaltic pump for automatic control of NO channel s damp Room for O2 paramagnetic sensor MEASUREMENT MODULE Thermal insulation and stabilization of the sensors compartment Room for 9 sensors and 4 EC cells sensors, each with its own thermal stabilization (to 0,01 C) Double gas channel: the first humid one for NO- and the second, dry one for all other sensors Measurement of ambient and gas temperatures Measurement of atmospheric and differential pressures Measurement of chimney draft and flow velocity (with help of Pitot tube) 2

ADD-ONS, TAILORED SOLUTIONS (EXAMPLES) Possibility to prepare overpressure version With secure, NPT 1/4 gas connectors With option to perform leakage test of the entire device prior measurements Possibility to deliver with / without frame rack Possibility to exclude the display and PC-104 module from the power supply Possibility to adjust / implement special options to the device program CEMS Photon S is tailored each time according to a specific requirements. Separate implementations may differ considerably in terms of construction. Especially gas connections may be present or not depending on individual configuration. Hereby pictures and drawings present device in an example configuration. PHOTON S ANALYSER BUILT INTO 19 OPEN FRAME RACK CONTROL MODULE WITH 6,4 VGA COLORFUL DISPLAY WITH TOUCHSCREEN MEASUREMENT MODULE CAN BE FITTED WITH UP TO 9 AND UP TO 4 EC CELLS DRYER MODULE HOLDS O2 SENSOR (PARAMAGNETIC OR PARTIAL PRESSURE). PREPARES THE GAS SAMPLE DEHUMIDIFIES, REMOVES DUST, SALT PARTICLES 19 MODULES CAN BE FITTED IN STANDARD 19 RACKS (OPTIONALLY ANALYSER CAN BE EQUIPPED WITH ONE) 3

CONTROL UNIT 486 mm * 176 mm * 287 mm Dimensions (W * H * D) Weight 4 kg 5 kg Casing material Aluminum, powder coated Operating conditions T: 10 C 50 C, RH: 5% 90% (non-condensing) Storing temperature -20 C 55 C Power supply: input maximal power consumption 90V 230V AC 150 W Operating system Windows CE 5.0 Display 6,4 VGA (640 * 480) Data storage: type capacity Compact Flash card max 4GB 2 * USB Interface for external devices (USB disk, mouse, keyboard) Communication interface with PC computer RS - 232C, RJ45 (Ethernet) Analogue outputs: 8x voltage 8x current 0V 10V DC, max 10mA per output 0/4mA 20mA 0V 24V; Hi_3,5V OC; max. 50mA Digital I/O: 8x inputs 8x outputs Relays outputs: quantity type limitations 4 SPDT 24V AC; max: 5A 4 SPDT 230V AC; max: 5A GAS CONDITIONING UNIT WITH CONDENSATION & NAFION DRYER 486 mm * 176 mm * 538 mm Dimensions (W * H * D) Weight 9 kg 10 kg Casing material Aluminum, powder coated Operating conditions T: 10 C 50 C, RH: 5% 90% (non-condensing) Storing temperature -20 C 55 C Power supply: input maximal power consumption Cooler type Drying method 90V 230V AC 150 W (without heated hose) Outlet 1: Based on Nafion exchanger Outlet 2: Based on Peltier cooling element with fan (12V DC supply) Outlet 1: Water transfer through Nafion membrane driven by partial vapour pressure differential - first order kinetic reaction Outlet 2: Water condensation by rapid cooling down Cooling temperature Outlet 1: n/a Outlet 2: 0 C 20 C 5 minutes Ready to operate after 4

Maximum gas flow for efficient drying (at inlet gas temp. 100 C and RH 100%) 100 l/h Gas filters: quantity material 2 PA - body, PC - cover, viton - sealing Filter insert: length ID OD material pore size 32mm 12mm or 15mm 18mm or 20mm PE 5_m With built-in peristaltic pump Condensate removal Peristaltic pump capacity 38 ml/min Heated hose temperature + 180 C electronically stabilised ~ 5 C Heated hose temperature hysteresis Heated hose length 3m (optionally 5m or 10m) Heated hose power supply: input maximal power consumption Heated hose thermocouple wires 230V AC 1000W K-type (S-type optionally) GAS CONDITIONING UNIT WITH NAFION DRYER 486mm * 176mm * 538mm Dimensions (W * H * D) 7kg 8kg Weight Aluminium, powder coated Casing material Operating conditions T: 10 C 50 C, RH: 5% 90% (non-condensing) Storing temperature -20 C 55 C Power supply: input maximal power consumption 90V 230V AC 150 W (without heated hose) Cooler type Drying method Based on Nafion exchanger Water transfer through Nafion membrane driven by partial vapour pressure differential - first order kinetic reaction Cooling temperature n/a 1 minute Ready to operate after Maximum gas flow for efficient drying (at inlet gas temp. 100 C and RH 100%) 100l/h Gas filters: quantity material 2 PA - body, PC - cover, viton - sealing Filter insert: length ID OD material pore size 32mm 12mm or 15mm 18mm or 20mm PE 5_m Condensate removal n/a Peristaltic pump capacity n/a Heated hose temperature + 180 C electronically stabilised 5

Heated hose temperature hysteresis ~ 5 C Heated hose length 3m (optionally 5m or 10m) Heated hose power supply: input maximal power consumption 230V AC 1000W Heated hose thermocouple wires K-type (S-type optionally) Under pressure in Nafion collar ~ 500 mbar MEASUREMENTS UNIT 486mm * 176mm * 538mm Dimensions (W * H * D) 10 kg 16 kg Weight (depends on installed sensors) Aluminium, powder coated Casing material Operating conditions T: 10 C 50 C, RH: 5% 90% (non-condensing) Storing temperature -20 C 55 C 90V 230V AC 150 W Power supply: input maximal power consumption Warming up time max 90 minutes Warming up temperature About 18 C above unit s outside air temperature ±5 C Maximum outside temperature drift not affecting warming up temperature MEASUREMENTS Variable Method Range Resolution Accuracy Time (T90) Tgas - gas temperature K-type thermocouple -10 1000 C 0,1 C ± 2 C Tgas - gas temperature S-type thermocouple -10 1500 C 0,1 C ± 2 C Tamb - boiler intake air temperature PT500 resistive sensor -10 100 C 0,1 C ± 2 C Differential pressure Silicon piezoresistive pressure sensor -25 hpa +25 hpa 1 Pa (0,01hPa) ± 2Pa abs. or 5% rel. Gas flow velocity Indirect, with Pitot tube & pressure sensor 1 50 m/s 0,1 m/s 0,3 m/s abs. or 5% rel. Lambda λ - excess air number Calculated 1 10 0,01 ± 5% rel. qa - stack loss Calculated 0 100% 0,1% ± 5% rel. Eta - η combustion efficiency Calculated 0 120% 0,1% ± 5% rel. IL - incomplete combustion Calculated 0 100% 0,01% ± 5% rel. 6

Method Range Resolution Accuracy Time (T90) Conformity Electrochemical 20,95% 0,01% ± 0,01% abs. or 5% rel. ISO 12039; CTM-030 Electrochemical, partial pressure 20,95% 0,01% ± 0,01% abs. or 5% rel. ISO 12039; CTM-030 Electrochemical, partial pressure 25,00% 0,01% ± 0,01% abs. or 5% rel. ISO 12039; CTM-030 Electrochemical, partial pressure 100,00% 0,1% ± 0,1% abs. or 5% rel. ISO 12039; CTM-030 Paramagnetic 25,00% 0,01% ± 0,01% abs. or 5% rel. EN 14789; OTM-13 Paramagnetic 100,00% 0,1% ± 0,1% abs. or 5% rel. EN 14789; OTM-13 20 000 ppm 1 ppm EN 15058; METHOD 10 10% 0,01% ± 0,03% abs. or 3% rel. EN 15058; METHOD 10 100% 0,1% ± 0,3% abs. or 3% rel. EN 15058; METHOD 10 5% 0,01% ± 0,03% abs. or 3% rel. ISO 12039; OTM-13 25% 0,01% ± 0,03% abs. or 3% rel. ISO 12039; OTM-13 100% 0,1% ± 0,3% abs. or 3% rel. ISO 12039; OTM-13 5% 0,01% ± 0,03% abs. or 3% rel. 25% 0,01% ± 0,03% abs. or 3% rel. 100% 0,1% ± 0,3% abs. or 3% rel. 1 000 ppm 1 ppm ISO 10849; METHOD 7E 5 000 ppm 1 ppm ISO 10849; METHOD 7E 1 000 ppm 1 ppm ISO 10849; METHOD 7E Electrochemical 1 000 ppm 1 ppm ± 5ppm abs. or 5% rel. 60 sec CTM-022 O2 - OXYGEN CO - CARBON MONOXIDE CO2 - CARBON DIOXIDE CH4 METHANE NO - NITRIC OXIDE 7

Method Range Resolution Accuracy Time (T90) 1 000 ppm 1 ppm ISO 7935; METHOD 6C 5 000 ppm 1 ppm ISO 7935; METHOD 6C 1 000 ppm 1 ppm ± 5 ppm abs. or 5% rel. 70 sec Electrochemical 2 000 ppm 1 ppm ± 10 ppm abs. or 5% rel. 50 sec Electrochemical 20 000 ppm 1 ppm ± 10 ppm abs. or 5% rel. 70 sec Thermal Conductivity Detector 10% 0,1% ± 0,5% abs. or 5% rel. Thermal Conductivity Detector 25% 0,1% ± 0,5% abs. or 5% rel. Thermal Conductivity Detector 50% 0,1% ± 0,5% abs. or 5% rel. Thermal Conductivity Detector 100% 0,1% ± 0,5% abs. or 5% rel. 2 000 ppm 1 ppm ± 0,03% abs. or 3% rel. Conformity H2S- HYDROGEN SULPHIDE Electrochemical H2 - HYDROGEN N2O - NITROUS OXIDE ISO 21258 CHF3 - FLUOROFORM (REFRIGERANT R23) 2,5% 0,01% VOC - VOLATILE ORGANIC COMPOUNDS PIT - Photoionization Detector 100 ppm 1 ppm ± 5ppm abs. or 5% rel. 120 sec METHOD 21 PIT - Photoionization Detector 1 000 ppm 1 ppm ± 5ppm abs. or 5% rel. 120 sec METHOD 21 STANDARD EQUIPMENT SUPPLIED ALONG WITH THE DEVICE Each installation of the Photon S analyser is unique and requires individual approach to customer s requirements Generally, the installation consists of three main modules each in 19 rack: Control module with colorful display and touch panel Gas conditioning module Measurement module Besides, the necessary part of the CEMS system are: 19 frame or cabinet for installation of aforesaid modules Gas probe pipe Heated hose 8

ADDITIONAL EQUIPMENT NECESSARY FOR THE ANALYSER TO WORK Heated hose Heated hose with heated gas filter supplies gas sample to the analyser s conditioning module. Hose has M30x1 threaded connection to fix gas probe pipe. The other end has magnetic quick coupler and electric connector to connect it with the analyser. Standard length of hose is 3m, it is possible to order other lengths of hoses. It is especially advised when dealing with high humidity and SO2, NO2, and other gases highly reactive with water. Gas probe pipe Gas probe is immersed in the gas duct and is supposed to extract the gas sample and to measure its temperature. Exchangeable probes are easily connected to probe holders (with M30x1 fastening). They have thermocouple type K (in some configurations type S) for measurement of gas temperature and a threaded fixing cone. There are many probe pipes available. They differ in length and working temperature. For work efficiency it is advised to own different probe pipes to be able to adjust to the measurement place. The pipe with the heated hose is a complete gas probe. Stationary gas probe Gas probe designed specially for stationary purposes. Probe is available in different lengths and is equipped with suitable holder (different types are available). Optionally it may also be equipped with: Thermocouple for measurements of gas temperature Sintered stainless-steel filter (cleanable) - especially recommended when dealing with high concentration of dust and soot Blow-back cleaning option - valve that allows to switch between measured gas a n d the compressed air inlet that is used for cleaning the sintered filter OPTIONAL EQUIPMENT & SPARE PARTS Pitot tube Pitot tube is an accessory that allows to perform measurement of the flow velocity of the gas stream. The measurement is performed indirectly Pitot tube is connected to analyser s differential pressure sensor. Analyser recalculates the differential pressure on the Pitot tube s outlets to velocity. A few lengths of tubes are available. Pitot tube has 2m gas tubings to connect it with the analyser. It may be provided with a suitable holder for stationary purposes. ordering codes: pitot tube 800mm - Z00-PITOT-8002 pitot tube 500mm - Z00-PITOT-5002 Holder - Z00-PITOT-HA4 Heated filter Heated filter is installed right after the gas probe. It is best when it is paired with heated hose to prevent vapour from condensing. WIFI communication interfaces Optional interface allows to communicate wirelessly with Photon S analyser ordering code: ZMA3-ADAP-WIFI 9

CONTROL UNIT FRONT VIEW SLOTS FOR EXTENTION MODULES (ANALOGUE INPUTS, DIGITAL OUTPUTS, RELAYS OUTPUTS) MODULE OF ANALOGUE OUTPUTS (CURRENT AND VOLTAGE) USB CONNECTORS 6,4 VGA (640*480) COLORFUL DISPLAY WITH TOUCHSCREEN DIAGNOSTIC LEDS POWER SWITCH CONTROL UNIT REAR VIEW ETHERNET SOCKET MAINS CORD COMMUNICATION BETWEEN MODULES COOLING FAN SLOTS FOR EXTENTION MODULES (ANALOGUE OUTPUTS, ANALOGUEINPUTS, DIGITAL OUTPUTS, RELAYS OUTPUTS) 10

GAS CONDITIONING MODULE FRONT VIEW PERISTALTIC PUMP (WITH PELTIER DRYER ONLY) FINAL GAS FILTER CONDENSATE RESERVOIR (WITH PELTIER DRYER ONLY) GAS CONDITIONING MODULE CONDENSATE OUTLET (WITH PELTIER DRYER ONLY) POWER SWITCH REAR VIEW GAS CONNECTORS MAINS CORD COMMUNICATION BETWEEN MODULES COOLING FAN HEATED HOSE GAS FITTING (WITH MAGNETIC LOCK) PELTIER MODULE FAN HEATED HOSE ELECTRIC SOCKET GAS CONNECTORS WASTE GAS (FROM NAFION EXCHANGER) GAS FOR VENTILATION (FRESH AIR) 11 DRY GAS OUTLET #1 (FROM NAFION DRYER) DRY GAS OUTLET #2 (FROM CONDENSATION DRYER)

MEASUREMENT UNIT FRONT VIEW DIAGNOSTIC LEDS POWER SWITCH MEASUREMENT UNIT REAR VIEW COMMUNICATION BETWEEN MODULES MAINS CORD GAS AND ELECTRIC CONNECTORS COOLING FAN COMPARTMENT COVER GAS AND ELECTRIC CONNECTORS GAS INLET #2 (OPTIONAL) GAS INLET #1 GAS OUTLET 12 TEMPERATURE SENSOR SOCKET