Soil-Clik OWNER S MANUAL. Soil Moisture Sensor Wired Soil-Clik Module and Probe. Sensor for Compatible Hunter Controllers

Similar documents
Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Wireless Home Appliance Timer Remote Control Kit

Wireless Outdoor Air Reset Adaptor PN:

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

FEATURES AND SPECIFICATIONS

Installer Guide smart connect

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

Installer Guide smart connect

Universal Fan and Light Remote Control

Digital Thermometer with Ice Alert and Clock

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Wireless Rain Gauge with Rainfall Memory and Digital Clock MODEL: RGR382

CONNEX Smart Thermostat CST R00

Weather Light Model: BAR210 / BAR210U / BAR210A USER MANUAL. EU-Declaration of Conformity...7 FCC Statement...7 Declaration of Conformity...

Little Anne. Important Product Information

Driveway Alarm INSTALLATION MANUAL.

Honeywell Temperature & Humidity Sensor with LCD

Personal Ultrasonic Humidifier. FALLH-01 series

Installation and Operation Guide

Thermometer with Wired Sensor

Projection Alarm Clock

SYSTEM ENHANCEMENT MODULE

PRODUCT DIAGRAM PACKAGE CONTENTS

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

ADC-T2000. Smart Thermostat v1.5

PRODUCT DIAGRAM PACKAGE CONTENTS

Operation and Maintenance Manual

BBQ THERMOMETER DESCRIPTION OF PARTS. MODEL NO.: AW129/AWR129 Instruction Manual

IFS SFP Tranceivers User Manual

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

IN-OUT Thermometer with Cable Free Sensor and Clock

Smart Hub THERMOSTAT. Installation Manual

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

SC-6 Six Supervised Control Module

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

Smart Controller EMME ROOM-BY-ROOM. User Manual

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

programmable control model installation and setup guide M /11/ Hunter Fan Company

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

+ECO Solar Clock Model: RMR331ES / RMR331ESU / RMR331ESA USER MANUAL CONTENTS

W-505 W-505 CONTROL BRACKET INSTALLATION W-505 INSTALLATION. CAUTION! Do not use with wall dimmer or rocker switch.

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

Wireless External Alarm

Table of Contents. What to Expect with. Mounting Options. Tools Needed

CHOKING HAZARD-Toy contains

180 Degree Ceiling Mounted Occupancy Sensors

Integrated Sensor Suite with Fan-Aspirated Radiation Shield

Table of contents. Metra WBC-WBI RFID ISO Module - Technical Manual. Page 2

Wireless Rain Gauge with Indoor Temperature

DEHUMIDIFIER. User Manual 50BT, 70BT

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Wireless Driveway and Intruder Alert

Copyright Rollibot, LLC. All Rights Reserved USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

EW 40 Wireless Fan Control

Fume Hood Operating Display Panel

+ECO Solar Weather Clock Model: BAR332ES / BAR332ESA / BAR332ESU USER MANUAL CONTENTS

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

ShockLink. Important Product Information.

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

Campers Alert TM Portable System Hunters Alert TM Portable System

Wireless High Bay Sensor (WHS100) Installation Instructions

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

Wireless Color Weather Station

Homeowner s Installation Instructions & Operating Manual

TABLE OF CONTENTS. Box Contents...3. Quick Start Instructions Important Information Intended Use Meat Probe Use...

Ambient Weather RC-9362 Atomic Digital Wall Clock with Temperature User Manual

MILLA ELECTRIC FIREPLACE

Scan the below QR code to download Smart Flame

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

100 Ft. LASER DISTANCE METER

Wireless Thermostat (WTS10) Keypad Operation Guide

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Model: WS-8147U-IT Instruction Manual DC: ATOMIC DIGITAL CLOCK WITH MOON PHASE

Smart THERMOSTAT. Installation Manual

AGES. instruction manual DAISY BLOOM PROJECTION ALARM CLOCK

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

SUNRISE ALARM CLOCK. With Multicolor LED Lights HME040187N. Before using your Sunrise Alarm Clock, please read this manual.

1126 Series Ceiling Mount PIR Motion Detector

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

Digital Cooking Thermometer models / 00282

RF Projection Clock Model: RM939P POLERMO Projection Clock Model: RM939PA

HDCVI PTZ Network Camera

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

Safety Instructions. Be sure to observe the following instructions when using the device.

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL

Disclaimer. Trademarks. Copyright. Warranty

Transcription:

Soil-Clik OWNER S MANUAL Soil Moisture Sensor Wired Soil-Clik Module and Probe Sensor for Compatible Hunter Controllers

Introduction Soil-Clik is a soil moisture system that prevents overwatering when the soil is wet. Soil-Clik is designed for use with Hunter controllers that have normally closed smart sensor inputs, or with any AC-powered control system by interrupting the common wire to the valves. Module Probe 2

Table of Contents 4 Installation 4 Choosing the Probe Location 7 Installing the Probe 10 Choosing the Module Location 12 Connecting the Module to Hunter Products 12 Overview 13 ACC 13 ACC2 14 HC 14 HCC 15 I-Core 15 ICC2 16 PCC 16 Pro-C 17 Pro-HC 17 X-Core 18 Common Interrupt (Most AC-Powered Controllers) 19 Using the Soil-Clik with Solar Sync 20 Programming 20 LED Screen Overview 21 Programming Moisture Levels 22 Pausing Operation 22 Alarms 23 Troubleshooting Guide 23 Problems, Causes, and Solutions 24 Controller Compatibility 24 Controller Compatibility 25 Notices 25 FCC Notice 26 Certificate of Conformity to European Directives 3

Installation Choosing the Probe Location The moisture-sensing Soil-Clik probe must be installed within 1,000' (300 m) of the Soil-Clik module, using 18 AWG (1 mm 2 ) direct burial (UF) wire. Choose a zone with full sun exposure that is in the fastest-drying area of the landscape. If necessary, move valve wires so that this is the last (highest-numbered) station to water. Choosing the Zone Install the probe within the last typical zone to irrigate, so that normal irrigation will not interrupt watering prematurely. 1,000' (300 m) 4

Installation Choosing the Exact Spot Select an area with full sun exposure that represents the fastest-drying irrigated area. 5

Installation Place in the Root Zone In turf applications, the probe should be placed in the root zone, approximately 6" (15 cm) deep (adjust for actual turf conditions). For shrubs or trees, select a deeper depth that matches the root zone. For new plantings, choose a spot halfway down the root ball, adjacent to native soil. 6

Installation Installing the Probe 1. Soak the lower two-thirds of the probe for 30 minutes before installing. Do not allow water to cover the top cap where the wires are connected. 2. Use ½" (12 mm) PVC pipe to make a vertical hole to desired depth in the soil (outside diameter 7/8" (22 mm)). 7

Installation Installing the Probe (continued) 3. Mix a slurry of native soil and water, and pour it into the hole. 4. Place the sensor in a vertical position (do not tilt it more than 45 ) at the bottom of the hole. Do not install the probe horizontally! 8

Installation Installing the Probe (continued) 5. Pack native soil tightly around the probe. Soil must be in full contact with the probe. 6. Allow the probe to acclimate for two to three days and water normally, before proceeding to sensorbased irrigation. 9

Installation Choosing the Module Location The Soil-Clik module is designed for outdoor installation when necessary. However, electronics will benefit from a protected location when practical. An indoor location, or inside the controller enclosure (ACC, ACC2, I-Core) is recommended. If the module must be outdoors, place it away from direct sunlight and sprinkler spray for best results. Avoid placing the module near electrical boxes and sources of electrical interference. Mount within 6' (2 m) of the host controller. 6' (2 m) 10

Connecting the Probe to the Module Use only 18 AWG (1 mm 2 ) or larger direct burial rated wire, up to 1000' (300 m) from the module. Connect the gray/black probe wires to the two gray module wires with waterproof connections (polarity is not important in this system). White Yellow Installation Gray connection Gray/Black connection Avoid high-voltage lines or other sources of electrical interference. Module Probe 11

Connecting the Module to Hunter Products Overview 1. Gray Wires: Connection to Soil-Clik probe 2. Yellow Wires: Soil-Clik module power, requires 24 VAC power (100 ma max) ➌ ➋ 3. White Wires: Module output, to Hunter controller sensor input, or to interrupt 24 V common wiring to field ➊ Route all wires through low-voltage conduit hole in the controller enclosure. Make all external connections with waterproof connectors. Do not connect the Soil-Clik to high-voltage (120/230 VAC) wiring! 12

Connecting the Module to Hunter Products ACC ACC2 + SEN4 + + + SEN3 SEN2 SEN1 24 VAC + SEN1 SEN1 + SEN2 SEN2 + SEN3 SEN3 SEN4 SEN3 SEN2 SEN1 COM P/MV3 24VAC COM COM 1. Yellow power wires to the ACC 24 VAC and COM common power terminals 2. White wires to SEN sensor + and terminals 3. Or use the Common Interrupt method on page 18 1. Yellow power wires to the ACC2 24VAC and COM common power terminals 2. White wires to SEN sensor + and terminals 3. Or use the Common Interrupt method on page 18 13

Connecting the Module to Hunter Products HC HCC 24V 24V SENSOR 1 SENSOR 2 COMMON SEN 1 SEN 2 SEN C REM 24VAC 24VAC GND 1. Yellow power wires to the HC 24V power terminals 2. White wires to the SENSOR and sensor COMMON terminals 3. Or use the Common Interrupt method on page 18 1. Yellow power wires to the HCC 24VAC power terminals 2. White wires to the SENSOR and sensor COMMON terminals 3. Or use the Common Interrupt method on page 18 14

Connecting the Module to Hunter Products I-Core ICC2 SEN S1 S1 S2 S2 C C GND AC1 AC2 REM C P/MV SEN TEST REM 24VAC 24VAC GND 1. Yellow power wires to the I-Core AC1 and AC2 power terminals 2. White wires to SEN sensor terminals 3. Or use the Common Interrupt method on page 18 1. Yellow power wires to ICC2 24VAC power terminals 2. White wires to SEN sensor terminals 3. Or use the Common Interrupt method on page 18 15

Connecting the Module to Hunter Products PCC Pro-C AC2 GND AC1 AC2 REM SEN SEN AC1 GND SEN SEN 1. Yellow power wires to the PCC AC1 and AC2 power terminals 2. White wires to the SEN sensor terminals 3. Or use the Common Interrupt method on page 18 1. Yellow power wires to the Pro-C AC1 and AC2 power terminals 2. White wires to the SEN sensor terminals 3. Or use the Common Interrupt method on page 18 16

Connecting the Module to Hunter Products Pro-HC X-Core 24 VAC 24 VAC GND SEN-1 SEN COM SEN-2 24VAC REM SEN C 1. Yellow power wires to the Pro-HC 24VAC power terminals 2. White wires to the SEN sensor and SEN COM common terminals 3. Or use the Common Interrupt method on page 18 1. Yellow power wires to the X-Core 24VAC power terminals 2. White wires to the SEN sensor terminals 3. Or use the Common Interrupt method on page 18 17

Connecting the Module to Hunter Products 24V 24V Yellow White COM 1 2 3 4 Common Interrupt (Most AC-Powered Controllers) 1. Connect Yellow power wires to 24V power in the controller. 2. Cut field common wire(s), and splice one Soil-Clik white wire to each end of the common. 18

Connecting the Module to Hunter Products Using the Soil-Clik with Solar Sync Soil-Clik is ideal when installed together with Hunter Solar Sync. Solar Sync adjusts run times for weather conditions, and provides automatic rain and freeze shutdown. Soil-Clik prevents unnecessary watering when soil is still wet. The following controllers have a single sensor terminal and the Soil-Clik should be installed using the Common Interrupt method shown on page 18. ICC2, PCC, Pro-C, and X-Core 1. Connect Solar Sync to controller sensor terminal, as described in the Solar Sync owner s manual. 2. Do not connect to SEN terminals if Solar-Sync is already installed. The following controllers have multiple sensor terminals and can accommodate more than one sensor. The Solar Sync and Soil-Clik can be installed by using either the conventional or Common Interrupt methods. ACC, ACC2, HC, HCC, and I-Core 1. Connect Solar Sync to controller sensor terminal, as described in the Solar Sync owner s manual. Compatible with ACC version 5.0 and later Compatible with I-Core version 3.0 and later 19

Programming LED Screen Overview Soil-Clik is used to set a desired moisture level. The level may be changed with the + and - buttons. When the desired moisture has been reached, Soil-Clik will interrupt irrigation either through the controller s sensor input, or by breaking the common wire to the field. ➋ ➊ ➌ ➍ ➎ ➏ LCD SCREEN 1 Alarm 2 Measurement 3 Moisture level 4 Moisture setting 5 Watering interrupted 6 Pause/override 20

Programming Programming Moisture Levels The bar steps in the display represent centibars of soil water tension on a scale of 10 to 100. High numbers indicate dry soil, or soil from which it is very difficult for plants to extract moisture. Start with a midrange setting based on the table or local experience. Observe results, and adjust as needed. Press to increase, to decrease. The level of the arrows indicates the point at which irrigation will be shut off. When the moisture level is reached, Soil-Clik stops the irrigation. This is shown by the symbol. 0 10 Very wet 10 30 Sand 30 60 Silt and loam 60 100 Clay 100 Very dry 21

Programming Pausing Operation Press to override the Soil-Clik. It will allow the controller to water normally, even if the soil moisture level has been reached. Alarms The Alarm symbol shows an internal malfunction. Replace the Soil-Clik Module if this occurs. When it is in Pause mode, the Pause symbol is shown and the rest of the screen is blank. Press again to return to normal operation. Pause does not pause watering. It overrides the Soil-Clik, and allows watering. Press to update the moisture level reading. The Measurement icon will appear. An updated measurement (bars) will appear within 5 seconds. 22

Troubleshooting Guide Problems, Causes, and Solutions PROBLEM CAUSE SOLUTION Plants are too dry Moisture level setting too low Sensor in wrong location Plants are too wet Moisture level setting too high Sensor in wrong location Pause mode has been set Increase arrows (+ button) Move sensor or valve wires; sensor must be in last zone to water Decrease arrows (- button) Move sensor to a sunnier location Turn off Pause Moisture level seems incorrect Incorrect sensor installation/placement Ensure full soil contact with sensor Check sensor wiring Moisture always at max or minimum Failed sensor Use handheld sensor meter to verify operation Alarm symbol is displayed Module failure Replace module (part no. SC-MOD) Module display is blank Power failure Check power connection to host controller For more detailed information, application notes, or assistance, please visit us at www.hunterindustries.com. 23

Controller Compatibility Controller Compatibility The Soil-Clik is designed for use with Hunter ACC, ACC2, HC, HCC, I-Core, ICC2, PCC, Pro-C, Pro-HC, and X-Core controllers. Dimensions Module: 41/2" H x 31/2" W x 11/4" D (11.4 cm H x 8.9 cm W x 3.2 cm D) Probe: 21/4" H x 7/8" Dia (8.25 cm H x 2.22 cm Dia) Wire to probe: 1,000' (300 m) max, 18 AWG (1 mm 2 ) diect burial wire 24

Notices FCC Notice This device complies with FCC rules Part 15. Operation is subject to the following two conditions: 1. This device may not cause harmful interference and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for class B digital devices, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/tv technician for help The user is cautioned that changes and modifications made to the equipment without the approval of the manufacturer could void the user s authority to operate this equipment. 25

Notices Certificate of Conformity to European Directives Hunter Industries hereby declares that this remote control device is in compliance with the essential requirements and other relevant provisions of Directive 2014/30/EU. Declaration of Conformity: We, Hunter Industries Incorporated, 1940 Diamond Street, San Marcos, CA 92078, declare under our own responsibility that the Soil Clik, to which this declaration refers, conforms with the relevant standards: EN 61000-6-1 and EN 61000-6-3. Andrew Bera, Senior Regulatory Compliance Engineer Place San Marcos, CA Date May 1, 2018 26

Notes 27

Helping our customers succeed is what drives us. While our passion for innovation and engineering is built into everything we do, it is our commitment to exceptional support that we hope will keep you in the Hunter family of customers for years to come. Gregory R. Hunter, CEO of Hunter Industries RESIDENTIAL AND COMMERCIAL IRRIGATION Built on Innovation Hunter Industries Incorporated 1940 Diamond Street, San Marcos, California 92078, USA www.hunterindustries.com 2018 Hunter Industries Incorporated LIT-609-OM-EN 5/18