M6063A Compact Rotary Mixing Valve Actuator

Similar documents
T6984F,G Electronic Floating Control Thermostats

T6984 A,D,E Electronic Floating Control Thermostats

L8151A Triple Aquastat Relay

T7984 A,B,C Electronic Modulating Control Thermostats

T7079A,B Solid State Remote Temperature Controllers

Aquatrol Outdoor Temperature Compensators AQ675A for Floating Control Valves AQ775A for Injection Pumps

C6097A,B Pressure Switches

C554A Cadmium Sulfide Flame Detector

CR7075 Two-Stage Lighting Controller

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

T4398A,B High Performance Electric Heat Thermostats

Commercial/Industrial Combustion Control Level Three Announcement

T4098A,B Deluxe Electric Heat Thermostats

The T6140A,B Remote Bulb Temperature Controller

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

L4188A,B; L4189A,B; L6188A-C; L6189A-C Aquastat Controllers

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

Q7300L Series 2000 Commercial Thermostat Subbases

RA889A Switching Relay

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

T8011R Programmable Heat Pump Thermostat

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats

AQ255 and AQ257 Series Expansion Zoning Panels

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

H1008A,D Automatic Humidity Controls

AQ250 Series Hydronic Control Panels

F25F Media Air Cleaner

L7224A,C; L7248A,C,L Oil Electronic Aquastat Controllers

Q7100A,C,D Thermostat Subbases

R8888A,B Hydronic Circulator Zone Panels with Priority Control

F150E Media Air Cleaner

Q7300H Series 2000 Commercial Thermostat Subbases

C7232A,B Sensor and Controller

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

T8524 Deluxe Electronic Thermostat

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

Sola Hydronic Control. An Eco-Friendly Solution.

Product Manual SZ2161. Description The SZ2161 is a microprocessor-based controller designed for water source heat pump plant control applications.

T7100D Microelectronic Conventional Thermostat

R8182D,E,F,H,J Combination Protectorelay Primary Control and Aquastat Controller

T8112 Programmable Thermostat

T834C Heating-Cooling Thermostat

Instructions For A and Flame Simulators

- Data Brochure Universal Reset Module 422

IS Series Pressure Sensing Switches

ARGO AR SERIES CONTROLS

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

CP CP

- Data Brochure Mixing Control 360

F200E Charged-Media Air Cleaner

Immersion Temperature Controller

TAC Erie VL500. Application. Features. Zone Valve Control Center General Instructions

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Q382A,B Pilot Burners

D896 Automatic Vent Damper

AQ252 Universal Injection/Mixing Boiler Reset Control Panels

CAUTION: ELECTRICAL HAZARD

- Data Brochure Universal Reset Module 423

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

MODEL Day Programmable 1 Heat / 1 Cool Electric / Gas

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

T874 Multistage Thermostat and Q674 Subbase

T8411R Electronic Heat Pump Thermostat

W8703A Damper Interface Module

T4398A,B Precision Electric Heating Thermostat

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat

CT2700 An Electronic Round Programmable Thermostat

TK-1001, 1101, 1201, 1301, 1601

I/A Series 716C 1/16 DIN Temperature Controller

RA890G Protectorelay Primary Control

- Data Brochure Mixing Control 361

Deluxe Programmable Heat Pump Thermostat T8611M

Room Temperature Controller

Q7100A,C Thermostat Subbases

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

ProRadiant Basic Heating Control Installation Manual 2013

T7047C,G,H Remote Space Sensors

Two-Position Electric Duplex Room Thermostats

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

- Data Brochure Mixing Control 360e

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

B-40/B-41 Modulating Temperature Controller

- Data Brochure Universal Reset Control 364

Product Manual SZ2182

Heat Link. Technical Guide

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

TP970 Series CONVERTASTAT Kits

P7810A-D Pressuretrol Controller

Transcription:

M6063A Compact Rotary Mixing Valve Actuator PRODUC DAA FEAURES: 24 Vac floating input for automatic control. Single screw attachment to V5442 valve body. Multi-poise mounting. Color-coded position indicator. Manual valve operator. Auxiliary end switch for cascade control outputs. Sealed assembly; flylead electrical connections. APPLICAION he Corona series of Compact Rotary Valves and Actuators provide integrated mixing of boiler supply, boiler return, loop supply, and loop return water in hydronic heating systems. he V5442 valve can mix both loop supply water and boiler return water simultaneously to control loop supply temperature and boiler shock or flue gas condensation protection. hey may be plumbed in either a direct mixing or injection configuration. he effective Cv of the valves is increased when piped in an injection configuration. he M6063 actuator enables automatic mixing operation when used with an AQ675A Aquatrol Outdoor emperature Compensator, or 6984 proportional room thermostat. Contents Application... Features... Specifications...2 Ordering Information...2 Installation...3 Settings...3 Operation...5 Checkout and est...6 roubleshooting...6 Copyright Honeywell Limited/Limitée All Rights Reserved

M6063A Corona Compact Rotary Mixing Valve Actuator SPECIFICAIONS ORDERING INFORMAION SPECIFICAIONS Important he specifications given in this publication do not include normal manufacturing tolerances; therefore, an individual unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed. Models: he M6063A actuator enables automatic control of the V5442N 4-way rotary mixing valve by tri-state (floating) controllers. Electrical Ratings: Power Supply: 24 Vac, 50/60 Hz, 3 VA, SPD, or SP3 (tri-state) for proportional control. cable: = common; = clockwise rotation; = rotation. Auxiliary Switches: 24 Vac, 3 A, 24 VA pilot duty, Class 2, normally closed. Gray cable. S (black/gray pair) opens at left () end stop. S2 (brown/pink pair) opens at right () end stop. Enclosure rating: double insulated, IP44 (exceeds NEMA 3) Mechanical Specifications: Dimensions: see Fig.. orque: 60 in-lb. (7 Nm) Manual declutch. iming: 00 seconds for 90 (full) stroke. Shipping weight:.3 lb. (0.6 kg) emperature Ratings: Ambient: 32 F to 40 F (0 to 60 C) Water: 36 F to 230 F (2 to 0 C) Shipping: -40 F to 40 F (-40 to 60 C) Humidity Ratings: Less than 90% RH, non-condensing. Electrical Connections: Color-coded 40" ( m) flyleads Dimensions: See Fig.. Cross Reference: M6063 functionally replaces Centra VRK0-24 valve actuator when used with V5442 valve body. Controller Compatibility: PI or PID tri-state control signal for proportional control action, such as supplied by AQ675 Outdoor emperature Compensator, W964F Aquatrol reset controller, or 6984 floating commercial thermostat. Fig: M6063A dimensions in inches (mm). 3/6 (300) 3/6 (47) 2 3/4 (69) 4 (0) 3 3/6 (8) ORDERING INFORMAION When purchasing replacement or modernization products from your wholesaler or distributor, refer to the price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:. Your local Home and Building Control Sales Office (check white pages of your phone directory.) 2. Home and Building Control Customer Logistics Honeywell Inc. 885 Douglas Drive North Minneapolis, Minnesota 55422-4386 (62) 95-000 In Canada Honeywell Limited-Honeywell Limitée, 55 Gordon Baker Road, North York, Ontario M2H 3N7. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, aiwan, United Kingdom, U.S.A. 95C-0887 2

M6063A Corona Compact Rotary Mixing Valve Actuator INSALLAION WIRING INSALLAION When Installing this Product.... Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. 5. Follow local codes for installation and application. WIRING Control! CAUION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect all power supplies before installation. Actuator. If the boiler supply enters the valve body from the left side, orient the M6063 with the knob on the left end of the motor housing. If the boiler supply enters the valve body from the right side, orient the M6063 with the knob on the right end of the motor housing. See Fig.2. 2. Set the valve to position 5, then remove and discard the manual handle. 3. Orient the M6063 actuator so that the single long mounting screw threads into the same boss used to identify the boiler supply. Use the brass spacer to avoid case deformation. See Fig. 3. 4. Select the correct side of the position scale, and place in the manual adjustment knob of the actuator. See Fig. 3. Snap on the clear plastic cover. 5. Wire the actuator for operation. See Fig. 4 to 8. Fig: 2 V5442 Valve and Actuator orientation. A. Boiler supply enters B. Boiler supply enters from the left. from the right. All wiring must comply with applicable local codes, ordinances and regulations. Refer to Fig. 3 through 8 for typical wiring diagrams. M6063A are extra low voltage, class 2 devices. Mounting Valve We recommend that the reset controller be installed within 20" (0.5 m) of the valve body to keep wiring complexity to a minimum. Suppy boss (actuator mounting hub) Suppy boss (actuator mounting hub) he valve must be oriented correctly towards the boiler supply water in order to work correctly. Boiler supply water may enter from the left or right of the valve to be used with an M6063 actuator. Mixed loop supply exits the valve from the top of the valve. he valve stem socket must not point to the floor to prevent water from falling on the M6063. Fig: 3 M6063 actuator mounting on V5442N body. 3 95C-0887

M6063A Corona Compact Rotary Mixing Valve Actuator WIRING Fig. 4 M6063A basic wiring Fig. 5 M6063 wired to AQ675 Aquatrol Outdoor emperature Compensator, left boiler water entry. AQ675 Fig. 6. M6063 wired to AQ675 Aquatrol Outdoor emperature Compensator, right boiler water entry. AQ675 Power/est Call for Heat Min.Boiler Ret. Circulator Boiler Open Close PWR (HO) C CIRC C2 Mix. Min. emperature OFF 24V~ 4VA OHER Boiler Return Minimum Outdoor Low VC6800 Series Boil. Ret. Power/est Call for Heat Min.Boiler Ret. Circulator Boiler Open Close PWR (HO) C CIRC C2 Mix. Min. emperature OFF 24V~ 4VA OHER Boiler Return Minimum Outdoor Low VC6800 Series Boil. Ret. BOIL ES Mix Sup. BOIL ES Mix Sup. 3/4" /2" 50% 0% Out. 3/4" /2" 50% 0% Out. R W COM. OPEN ClOSE MIXING/INJ.VALVE HERMOSA R W COM. OPEN ClOSE MIXING/INJ.VALVE HERMOSA S S2 Gray Gray Cable Pink Gray Cable 4 95C-0887

M6063A Corona Compact Rotary Mixing Valve Actuator SEINGS OPERAION CHECKOU Fig. 7 M6063 wired to 6984D for room temperature control, boiler supply enters from left. Fig. 8 M6063 wired to 6984D for slab heating control with boiler feedback, boiler supply enters from right. Remote Sensor 6984D Refer to form no. 95C-083 6984D Refer to form no. 95C-083 (hot) NSB Input Mode Input Sensor Input Internal Sensor DIP Switch Settings DIP Switch Settings S5 0 S5 0 S6 0 }(90 sec.) S6 0 }(90 sec.) S7 S7 Power Supply 24 Vac Motor Close Output Motor Open Output 2 On/Off 24 Vac Class 2 2 24 Vac Class 2 ransformer ransformer A/C Optional 24Vac Air Conditioning Relay (hot) NSB Input Power Supply 24 Vac Mode Input Sensor Input Motor Close Output Motor Open Internal Sensor Output 2 On/Off 2 Boiler S S2 Gray Pink Gray Cable } o Loop o Loop Circulator Gray Cable } Circulator Relay Relay 2 Mode jumper sets Floating Output to heating sequence. For 2-stage heating control, remove mode jumper and interchange motor's brown and black leads (see fig. 8). If air conditioning interface used, set Output 2 cycle rate to 'Slow 4 cph' (S=0), Zero Energy Band to '5 F/3 C' (S2=), Setpoint Dial Definition to 'Centered' (S3=0, S4= 0). 2 6984 control range is 55 to 90 F (3 to 32 C). If supply water temperature exceeds 90 F, install remote sensor on REURN line and set thermostat to desired SPACE temperature Set Output 2 cycle rate to 'Slow 4 cph' (S=0), Zero Energy Band to 3 F/.5 C (S2=0), Setpoint Dial Definition to 'Cooling' (S3=, S4=0) SEINGS he indicator scale on the M6063 ranges from to 9, where (minimum) corresponds to no flow from boiler to loop and full return of boiler supply to boiler return. his scale is approximately proportional to radiation heat output, and inversely proportional to boiler return water temperature, but is not calibrated and intended for reference only. his scale matches the scale on the V5442 valve body. Each auxiliary switch opens at one end of the actuator travel. he black/gray switch opens when the actuator runs fully counterclockwise (powered on the black control line). he brown/pink switch opens when the actuator runs fully clockwise (powered on the brown control line). Either switch may be used to control auxiliary equipment such as a circulator relay when the valve is mixing supply water, but the appropriate switch must be chosen according to valve and actuator orientation. OPERAION he rotary control plug of the V5442 diverts boiler supply water to both the loop supply and boiler return. At the same time, the control plug also diverts loop return water to the boiler return and back to the loop supply. When the loop does not use much boiler water, most of it is returned to the boiler. he loop supply water temperature is the result of mixing boiler supply and loop return water, and boiler return water temperature is the result of mixing loop return water with boiler supply water. he valve control plug has a modified equal percentage mixing characteristic on the mixed loop output to give linear heat output in the space. he plug uses a linear mixing characteristic on the mixed boiler return to give linear temperature control of boiler return water. he M6063 may be used to control space temperature for comfort, boiler return water temperature to prevent boiler shock and condensation, or both simultaneously, depending on the sophistication of the control system. 95C-0887 5

M6063A Corona Compact Rotary Mixing Valve Actuator ROUBLESHOOING SERVICING CHECKOU AND ES Checkout. urn on loop and main circulators. 2. Depress the M6063 indicator knob to declutch the motor. Open the valve and verify that the loop is receiving full boiler supply. Check that equipment wired to the M6063 auxiliary switch comes on properly. 3. Close the valve to verify the loop is on 00% recirculation. Check that equipment wired to the M6063 auxiliary switch de-energizes in the valve closed position. 4. urn off the circulators. 5. Set the controller to its maximum setpoint. Verify that the valve has opened to full flow from the boiler. 6. Set the controller to its minimum setpoint. Verify that the valve has opened to full flow from the loop return. 7. Restore the controller to its operating settings. ROUBLESHOOING able 2. roubleshooting Symptom Possible Causes Action Space temperature too low. Boiler return temperature too low. Space gets colder as higher valve settings selected. hermostat set too low. 2. Mixed supply water not hot enough.. Boiler Aqustat control set too low. 2. Mixed return water not hot enough. 3. Aquatrol minimum temperature too low. Loop supply and boiler return pipes are reversed.. urn up thermostat. 2. Set V5442 to higher number. urn up Aquastat. 2. Set V5442 to lower number 3. Increase Aquatrol minimum temperature setting Switch control handle to opposite scale. SERVICING he M6063 contains no serviceable parts. If defective, replace the actuator. In automatic control systems where the V5442 has been motorized with an M6063 actuator, the V5442 should be operated every 3 days or so during the off season to ensure the valve does not seize up. Home and Building Control Honeywell Inc. Honeywell Limited-Honeywell Limitée 885 Douglas Drive North 55 Gordon Baker Road Minneapolis, MN oronto, ON 55422-4386 M2H 3N7 95C-0887 RJ 0/99 Printed in U.S.A. www.honeywell.com