Motorized Sweep Air Diffuser Water Tank LCD Panel Cooler Housing Water Inlet GFCI Plug EVAPORATIVE AIR COOLER Instruction Manual Model 246529 Drain Plug Locking Casters Manifold Water Distributor Circulator Water Pipe Motor Support Brace Motor Fan Blade Grill Standard Hose Connection Media Pad
EVAPORATIVE AIR COOLER Model 246529 TROUBLESHOOTING CONTENTS: Malfunction Reason Solution Package Contents 2 About The Product 3 Application 3 Technical Specification 4 Features 4 Warning Information 4,5 Control Panel / PCB 5 Remote Control 5 Control Functions 5 Set-Up 6 Maintenance 6 Troubleshooting 7 Detailed Pictures 8 Power indicator will not light up Non-responsive controls No Power No Power Breakers tripped Panel light is out Master Control is broken Power frequency interference Environment interference Panel is broken Unit is unplugged Check reset breaker on GFCI Plug Check breaker box in building Change the panel light Power off and on unit Remove or keep away from interference Change panel Thank you for purchasing an Evaporative Air Cooler from Global Industrial. Please Read These Instructions Carefully Before Operation. Please note that the actual appearance of the product purchased is subject to change and may vary from the illustrations in this instructions manual due to continuous product upgrades. Although there may be slight differences between the actual product and the illustrated version, it will not in any way affect the performance of the product you purchased. Fan will not work or fan speed is too low Motor does not work properly Drain valve leaks water Fan does not turn Motor is burnt out Master Control is broken Master is broken Panel is broken Drain valve is loose Change fan Change motor Change the panel Screw tightly PACKAGE CONTENTS: Diffuser does not work Motor is burnt out Crankshaft is broken Crankshaft is out of position Change motor Change crankshaft Return crankshaft to position 1 Evaporative Air Cooler Unit 1 Remote Control 1 Operating Instructions Manual Fan spouts water Water pipe has fallen off Check the water pipe Note: Instructions are for reference purposes only. If technical assistance is needed, please call Customer Service 800-645-2986. 2 www.globalindustrial.com Model 246529 7
TECHNICAL SPECIFICATION Model 246529 Fan Diameter 20 Max Airflow (CFM) 3,552 Power Supply / Frequency 115V/60Hz Power Consumption (Watts) 450 Style Axial Water Consumption (G/Hr) 1.05-1.59 Water Capacity (Gal) 15.85 Dimension (W x D x H) 33" x 18" x 55" Weight (lbs) 77 Effective Cooling Area (Sq. Ft.) 323-538 Media Pad Size 30.5"W x 9"D x 27"H WARNING: Low Voltage less than 110V or High Voltage greater than 120V may cause damage to motor and electronic controls. DO NOT use fan if power cord is damaged. DO NOT drive forklift, power trucks or any vehicle over power cord. If the product is not operating correctly, please refer to Troubleshooting Guide or contact Customer Service 800-645-2986. Any modification to fan will void warranty. Control Panel FEATURES Micro-computer programmed control panel with LCD display. 3-speed fan operation. Time setting function. Running Time. Starting Time. Motorized sweep to direct output airflow. Convenient remote control. Specially designed powerful 20" diameter fan. Thick cooling pad measures 30.5"W x 9"D x 27"H for improved heat absorption. 4 rubber casters with brakes. Remote Control Battery Not Included Uses CR2025 3V battery WARNING INFORMATION Before operating machine, please read instructions carefully. Operate in the following conditions: 65-113 F Operating Temperature. MAX with 113 F Water Temperature. Area must be free from airborne pollutants and contaminant's. Ventilated, open environment with fresh air supply. Electric voltage must not exceed 115V +/-5V voltage. CONTROL FUNCTIONS: Operate functions by pressing button on control panel. Power "ON/OFF" switch. Press "COOL" button to activate cooling function. Water pump will circulate water into the cooling pad for one minute, then the fan will activate. Airflow Wind "SPEED" for desired airflow setting (Low / Medium / High). "SWING" - Motorized sweep of diffusers. "TIMER" button to set automatic timer. Dual Timer. Timer can be set to start in x hours. Timer can be set to turn off in x hours. 4 www.globalindustrial.com Model 246529 5
SET-UP! WARNING! Unplug fan before removing media pad. Fan can start unexpectedly due to the timer control feature. Before operating machine, please follow the instructions listed below: Add Water. Clean water must be used. Use hose connection on left side (hose not included). Manually add water through the water inlet opening on right side. Pour water slowly to avoid water spillage and prevent risk of electric shock. Fill up to "MAX" level only. Plug the unit into a 115V/60Hz, single phase outlet (Check outlet for correct polarity) Power indicator will light up. Note: If the power cord is damaged, it must be replaced by the manufacturer or a qualified electrician to avoid hazards.! WARNING! Unit is not intended for use by children or persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use by a person responsible for their safety. MAINTENANCE To ensure unit releases fresh and clean air, always change the water when dirty and regularly clean the cooling pad. Remove the filter by removing the screws then pressing the lock. Rinse the filter under running water to wash off dirt. DO NOT use pressure washer. Pull out the cooling pad and wash both sides under running water. Note: Never use pressurized water. Note: Never use liquid detergent. This may damage the pad. Open the drainage valve to remove remaining water, and then clean the water tank thoroughly with a soft cloth to remove dirt. Wash off dirt from the water sensor, water pump and drainage valve. Use mild soap and soft, clean cloth when cleaning the housing and chassis. Note: Do not use strong chemicals when cleaning unit. 6 www.globalindustrial.com WARNING!! Do Not Use an Extension Cord with this Fan. Check the outlet that this fan is plugged into for correct polarity before using outlet. Do not open control box compartment. No serviceable parts inside. All repairs must be done by authorized technician. Disconnect the power cord before changing media or opening fan housing. Do not modify equipment or power cord, Warranty will be voided. Test GFIC breaker on cord before each use of fan. This product contains chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. ABOUT THE PRODUCT The Evaporative Air Cooler is a high-tech product which utilizes water evaporation and moving air to cool the air. The cooler consists of a fan, a corrugated and fluted paper media pad and a water supply sump and water circulation system that maintains the saturation of the media. As the moisture in the moving air evaporates there is a cooling effect. The water level in the sump if manually filled can be monitored by the sight tube on the front of the housing. For constant automatic feed the water level is continuous by a float valve in the sump tank. Model 246529 3