XM-360 Process Module, XM-361 Temperature Module, and XM-362 Isolated Temperature Module

Similar documents
XM-441 Expansion Relay Module

XM-440 Master Relay Module

Compact I/O End Caps/Terminators

POINT I/O Field Potential Distributor Module

POINT I/O Field Potential Distributor Modules

FLEX I/O Digital Input and Output Modules

Installation Instructions

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

CENTERLINE 2100 Motor Control Center (MCC) Doors and Units with Vertical Operating Handles

IEC Lighting Contactor Specifications

Bulletin 1608N MiniDySC Dynamic Sag Corrector

Micro800 Programmable Controller External AC Power Supply

SLC 500 Power Supplies

Safety Function: Single-beam Area Access Control (AAC)

Magnetically Coded Non-contact Switch (MC2)

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

NGC-40-IO Control and monitoring modules for use with the Raychem NGC-40 system Installation Instructions

Siemens Automation Products Siemens AG All rights reserved A5E AB, 08/2017 1

Solid-State Contactor Specifications

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

Lifeline 5 Cable-pull Safety Switch

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

SEL-3422 Motor Relay HMI Quick-Start Guide

SensaGuard TM Integrated Latch Installation Instructions

GETTING STARTED GUIDE NI AI/8 AO/4 DIO, 0 V to 5 V, 12 Bit, 20 ks/s Aggregate

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

AO Annunciator Module

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

C-Bus Four Channel Analogue Output Unit Installation Instructions

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Operation and Maintenance Manual

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

Certificate of Compliance

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Molded Case Circuit Breakers, Bulletin 140G

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

AUGUST 2016 CONTENTS:

Certificate of Compliance

Certificate of Compliance

Module Features are-configurable, no module jumpers to set

GETTING STARTED GUIDE NI NI-XNET Hardware Selectable Interface. Français Deutsch 日本語한국어简体中文. ni.com/manuals

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

IntelliDoX Operator Manual

PROFIBUS Optical Bus Terminal (OBT) SIMATIC NET. PG/PC - PROFIBUS PROFIBUS Optical Bus Terminal (OBT) Introduction 1. Components of the product

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

DESCRIPTION. 42 mm. 125 mm

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

INSTRUCTION & SERVICE MANUAL

REA 105 Arc Protection Module. Operator s Manual

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

4) Intrinsic Safety Certification

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

VAMP 120 & 121. Arc flash detection units. Product picture

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

Fisher LCP100 Local Control Panel

C-Bus Four Channel General Input Unit Installation Instructions

Certificate of Compliance

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

2007 XYCOM AUTOMATION, LLC.

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

GETTING STARTED GUIDE. NI 9212 and TB TC, ±78 mv, 24 Bit, 95 S/s/ch Simultaneous, Isothermal Terminal Block

COMPACT FLAME CONTROLLER CFC 2000

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

UNI 321. User s Guide

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

ISO INTERNATIONAL STANDARD

TraceNet ECM Series Control System

This is a preview - click here to buy the full publication INTERNATIONAL STAN DARD. Radio-frequency connectors

Sensor Interface Module Installation/Operation Instructions

Getting started with

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

Transcription:

1440-xxx06-00RE Installation Instructions XM-360 Process Module, XM-361 Temperature Module, and XM-362 Isolated Temperature Module Catalog Numbers 1440-TPR06-00RE, 1440-TUN06-00RE, 1440-TTC06-00RE Topic Page North American Hazardous Location Approval 5 Mount the Module 6 Module Indicators 7 Reset Switch 8 Self-Test 9 Install the XM Serial Configuration Utility Software 9 Specifications 10 Additional Resources 11

Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence. IMPORTANT Identifies information that is critical for successful application and understanding of the product. Labels may also be on or inside the equipment to provide specific precautions. SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures. ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE). 2 Rockwell Automation Publication ENMON-IN360F-EN-P - February 2014

Environment and Enclosure ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating. This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such environments. This equipment is supplied as open-type equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The enclosure must have suitable flame-retardant properties to prevent or minimize the spread of flame, complying with a flame spread rating of 5VA or be approved for the application if nonmetallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications. In addition to this publication, see the following: Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for additional installation requirements NEMA Standard 250 and IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures ATTENTION: To comply with UL/CSA restrictions and the CE Low Voltage Directive (LVD), all connections to this equipment must be powered from a single source compliant with the following: A Listed Class 2 power supply, or a Listed ITE safety extra low voltage (SELV) power supply with the 1440-5AFUSEKIT fuse kit, or a protected extra low voltage (PELV) power supply certified to 60950 with the 1440-5AFUSEKIT fuse kit. The same power source must power any device to which the module is connected via its side connector (1) or any of its non-isolated circuits that include: power, XMbus, 4 20 ma outputs, and setpoint multiplier circuits. (2) (1) Power transmission across the XM module side connector must not exceed 3 A. (2) These circuits are all functionally isolated, but do not have adequate insulation to satisfy the isolation requirements of some electrical safety standards. Therefore the ground requirements for the circuits, specified in the individual user s manuals, must still be applied. Preventing Electrostatic Discharge ATTENTION: This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: Touch a grounded object to discharge potential static. Wear an approved grounding wriststrap. Do not touch connectors or pins on component boards. Do not touch circuit components inside the equipment. Use a static-safe workstation, if available. Store the equipment in appropriate static-safe packaging when not in use. Rockwell Automation Publication ENMON-IN360F-EN-P - February 2014 3

ATTENTION: The serial communication port is intended for temporary local-programming purposes only and not intended for permanent connection. The serial cable and power connections are not to exceed 3.0 m (9.84 ft): This product is intended to be mounted to a well-grounded mounting surface such as a metal panel or DIN rail. For DIN rail mounting, use zinc plated yellow-chromate steel DIN rail to assure proper grounding. The use of other DIN rail materials (for example, aluminum or plastic) that can corrode, oxidize, or are poor conductors, can result in improper or intermittent grounding. Secure DIN rail to mounting surface approximately every 200 mm (7.8 in.) and use end-anchors appropriately. Do not remove or replace a Terminal Base unit while power is applied. Interruption of the backplane can result in unintentional operation or machine motion. This module is designed so you can remove and insert it under power. However, when you remove or insert the module with power applied, I/O attached to the module can change states due to its input/output signal changing conditions. Take special care when using this feature. IMPORTANT Install the overlay slide label to protect the serial connector and electronics when the serial port is not in use. European Hazardous Location Approval The following applies when the product bears the Ex Marking This equipment is intended for use in potentially explosive atmospheres as defined by European Union Directive 94/9/EC and has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of Category 3 equipment intended for use in Zone 2 potentially explosive atmospheres, given in Annex II to this Directive. Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 60079-0, EN 60079-15 and EN 60079-11. WARNING: The installation of the XM-36x module includes the following warnings: This equipment must be mounted in an ATEX-certified enclosure with a minimum ingress protection rating of at least IP54 ( as defined in IEC60529), and used in an environment of not more than Pollution Degree 2 (as defined in IEC 60664-1) when applied in Zone 2 environments. The enclosure must have a tool-removable cover or door. This equipment must be used within its specified ratings defined by Rockwell Automation. Provision must be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140% of the rated voltage when applied in Zone 2 environments. This equipment must be used only with ATEX-certified Allen-Bradley terminal base units. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. Connection of the modules to barriers and/or sensors located in dangerous areas is the responsibility of the user. The XM-360, XM-361, and XM-362 modules must be installed in accordance with specification control sheets 48295-HAZ and 48299-HAZ. 4 Rockwell Automation Publication ENMON-IN360F-EN-P - February 2014

North American Hazardous Location Approval The following information applies when operating this equipment in hazardous locations. Informations sur l utilisation de cet équipement en environnements dangereux. Products marked "CL I, DIV 2, GP A, B, C, D" are suitable for use in Class I Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code. When combining products within a system, the most adverse temperature code (lowest "T" number) may be used to help determine the overall temperature code of the system. Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation. EXPLOSION HAZARD - Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. Substitution of components may impair suitability for Class I, Division 2. If this product contains batteries, they must only be changed in an area known to be nonhazardous. Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu'à une utilisation en environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non dangereux. Chaque produit est livré avec des marquages sur sa plaque d'identification qui indiquent le code de température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de température le plus défavorable (code de température le plus faible) peut être utilisé pour déterminer le code de température global du système. Les combinaisons d'équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l'installation. RISQUE D EXPLOSION Couper le courant ou s'assurer que l'environnement est classé non dangereux avant de débrancher l'équipement. Couper le courant ou s'assurer que l'environnement est classé non dangereux avant de débrancher les connecteurs. Fixer tous les connecteurs externes reliés à cet équipement à l'aide de vis, loquets coulissants, connecteurs filetés ou autres moyens fournis avec ce produit. La substitution de composants peut rendre cet équipement inadapté à une utilisation en environnement de Classe I, Division 2. S'assurer que l'environnement est classé non dangereux avant de changer les piles. WARNING: The installation of the XM-36x module includes the following warnings: When you insert or remove the module while power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. If you connect or disconnect the serial cable with power applied to this module or the serial device on the other end of the cable, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. Be sure that power is removed or the area is nonhazardous before proceeding. If you connect or disconnect the XMbus cable with power applied to this module or any device on the network, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. If you connect or disconnect wiring while the field-side power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. When you press the reset button while power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. Wiring to or from XM-360, XM-361, and XM-362 modules, which enters or leaves the system enclosure, must utilize wiring methods suitable for Class I, Division 2 Hazardous Locations, as appropriate for the installation in accordance with the following product drawings: - Without Barriers - 48295-HAZ - With Barriers - 48299-HAZ Rockwell Automation Publication ENMON-IN360F-EN-P - February 2014 5

Mount the Module The XM 360, XM-361, and XM-362 modules mount on a XM-944 terminal base unit, catalog number1440-tb-e. We recommend that you mount the modules after you have connected the wiring on the terminal base unit. Refer to the XM-944 Process/Temperature Terminal Base Installation Instructions, publication GMSI10-IN024, or the module user guide for the specific module for wiring information. ATTENTION: The XM-360, XM-361, and XM-362 modules are compatible only with the XM-944 terminal base unit. Verify that the keyswitch on the terminal base unit is at position 5 for the modules. Do not attempt to install the XM-360, XM-361, and XM-362 modules on other terminal base units. Do not change the position of the keyswitch after wiring the XM-944 terminal base unit. 1. Make certain the keyswitch (A) on the terminal base unit (C) is at position 5 as required for the modules. 2. Make certain the side connector (B) is pushed all the way to the left. You cannot install the module unless the connector is fully extended. 3. Make sure that the pins on the bottom of the module are straight so they align properly with the connector in the terminal base unit. 4. Position the module (D) with its alignment bar (E) aligned with the groove (F) on the terminal base. 5. Press firmly and evenly to seat the module in the terminal base unit. The module is seated when the latching mechanism (G) is locked into the module. 6. Repeat the above steps to install the next module in its terminal base. All grounds in the system must be tied to the same point of the same grounding electrode system. Maintain a 2.54 cm (1 in.) minimum clearance between the module and adjacent equipment. There are no orientation restrictions. 6 Rockwell Automation Publication ENMON-IN360F-EN-P - February 2014

Module Indicators Each module has eight module status indicators, which are on top of the module. Module indicators Module Status (MS) Indicator Color State Description No color Off No power applied to the module. Green Flashing Red Module performing power-up self-test. Flashing Module operating in Program mode. (1) Solid Module operating in Run mode. (2) Red Flashing Application firmware is invalid or not loaded. Download firmware to the module. Firmware download is currently in progress. The module power voltage is incorrect. Solid (1) Program mode - Typically this occurs when the module configuration settings are being updated with the Serial Configuration Utility. In Program mode, the module does not perform its normal functions. The signal processing/measurement process is stopped, and the status of the alarms is set to the disarm state to prevent a false alert or danger status. (2) Run mode - In Run mode, the module collects measurement data and monitors each measurement device. An unrecoverable fault has occurred. The module may need to be repaired or replaced. Network Status (NS) Indicator Color State Description No color Off Module is not online: Module is autobauding. No power applied to the module; look at Module Status indicator. Green Flashing Module is online (DeviceNet network) but no connections are currently established. (1) Solid Module is online with connections currently established. Red Flashing One or more I/O connections are in the timed-out-state. Solid Failed communication (duplicate MAC ID or bus-off). (1) Normal condition when the module is not a slave to an XM-36x module, programmable controller, or other master device. Rockwell Automation Publication ENMON-IN360F-EN-P - February 2014 7

Channel Status Indicator (six in all) Color State Description No color Off Normal operation with alarm limits on the channel. No power applied to the module; look at Module Status indicator. Yellow Solid An alert level alarm condition exists on the channel (and no sensor-out-of-range or danger level alarm condition exists). Red Solid A danger level alarm condition exists on the channel (and no sensor-out-of-range condition exists). Flashing A sensor-out-of-range condition exists on the channel. Reset Switch The XM-360, XM-361, and XM-362 modules have an external reset switch on top of the module. The Reset switch can be used to reset all latched relays in the Relay Expansion module when it is attached to an XM-360, XM-361, or XM-362 module. Reset Switch IMPORTANT The Reset switch resets the relays only if the input is no longer in alarm or the condition that caused the alarm is no longer present. 8 Rockwell Automation Publication ENMON-IN360F-EN-P - February 2014

Self-Test The XM-360, XM-361, and XM-362 modules perform a self-test at powerup. The self-test includes a status indicator test and a device test. During the status indicator test, the indicators are turned on independently and in sequence for approximately 0.25 seconds. The device test occurs after the status indicator test. The Module Status (MS) indicator is used to indicate the status of the device self-test. MS Indicator State Flashing red and green Solid green or flashing green Description Device self-test is in progress. Device self-test completed successfully, and the firmware is valid and running. Flashing red Device self-test completed, the hardware is OK, but the firmware is invalid. The firmware download is in progress. Module power voltage is incorrect. Solid red Unrecoverable fault, hardware failure, or Boot Loader program may be corrupted. Install the XM Serial Configuration Utility Software The XM Documentation and Configuration Utility CD is packaged with the XM modules. It contains the XM Serial Configuration Utility software, a set of user guides, hazardous location installation drawings, and electronic data sheet (EDS) files that are used by network configuration tools such as RSNetWorx for DeviceNet software. The user guides are in portable document format (PDF), and must be viewed with Adobe Acrobat Reader software. To install the XM Serial Configuration Utility software, follow these steps. 1. Insert the XM Documentation and Configuration Utility CD-ROM into the CD-ROM drive. If autorun is Enabled Disabled Then The Setup program starts automatically and the XM Serial Configuration Utility opening screen appears. Follow these steps. 1. Click Start, and then click Run. The Run dialog box appears. 2. In the Open box, type x:\autorun, where x is the letter of the drive containing the XM Documentation and Configuration Utility CD-ROM. 3. Click OK. The XM Serial Configuration Utility opening screen appears. 2. Follow the instructions that appear to install the XM Serial Configuration Utility. 3. When you are finished installing the software, remove the XM Documentation and Configuration Utility CD-ROM from the CD-ROM drives; store it in a safe place Rockwell Automation Publication ENMON-IN360F-EN-P - February 2014 9

Specifications The following table lists the technical specifications for the XM-360, XM-361, and XM-362 modules. Specifications are the same for the three module types, except where noted. Product Feature Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) Temperature, surrounding air, max Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat) Vibration IEC 60068-2-6 (Test Fc, Operating) Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock) Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock) Emissions CISPR 11 (IEC 61000-6-4) ESD immunity IEC 61000-4-2 Radiated RF immunity IEC 61000-4-3 EFT/B immunity IEC 61000-4-4 Surge transient immunity IEC 61000-4-5 Conducted RF immunity IEC 61000-4-6 Enclosure type rating Voltages/ranges Power dissipation External over-current protection Isolation voltage Wiring category XM-36X -20 65 C (-4 149 F) 65 C (149 F) -40 85 C (-40 185 F) 5 95% noncondensing 2 g @ 10 500 Hz 15 g 20 g Class A 6 kv contact discharges 8 kv air discharges 10V/m with 1 khz sine-wave 80% AM from 80 2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 3V/m with 1 khz sine-wave 80% AM from 2000 2700 MHz ±2 kv at 5 khz on power ports ±1 kv at 5 khz on shielded signal ports ±1 kv at 5 khz on XMbus port ±2 kv line-earth(cm) on shielded signal ports ±2 kv line-earth(cm) on XMbus port 10V rms with 1 khz sine-wave 80% AM from 150 khz 80 MHz None (open-style) XM360/362 Supply: 24V DC, 0.3 A max, Class 2/SELV XM361 Supply: 24V DC, 0.4 A max, Class 2/SELV 7.2 W max 440-5AFUSEKIT for SELV/PELV power sources Not rated 2 - on shielded signal ports 3 - on Serial and power ports 2 - on XMbus ports 10 Rockwell Automation Publication ENMON-IN360F-EN-P - February 2014

Product Feature Wire type (1) North American temp code IEC temp code XM-36X Signal connections: shielded Power connections: unshielded T4 T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Certifications Certification (1) (when Description product is marked) c-ul-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E234338. c-csa-us CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for US and Canada. See CSA File 150115. CE European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions Ex European Union 94/9/EC ATEX Directive, compliant with: EN 60079-15; Potentially Explosive Atmospheres, Protection "n" EN 60079-11; Explosive Atmospheres, Protection "i" EN 60079-0; General Requirements II 3 G Ex nac [ic] IIC T4X Gc KC Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3 (1) See the Product Certification link at http://www.rockwellautomation.com for Declarations of Conformity, Certificates, and other certification details. Additional Resources For more information on the products described in this publication, use these resources. Resource Description 1440 XM Monitoring Modules Specifications Technical Data, publication 1440-TD001 Provides technical specifications for the 1440 series of monitoring modules. XM-360 Process Module User Guide, publication GMSI10-UM006 Provides installation and configuration information for the XM-360 Process Module, along with technical specifications and DeviceNet information and objects for the module. XM-361/362 Temperature Module User Guide, publication GMSI10-UM008 Provides installation and configuration information for the XM-361 and XM-362 Temperature Module, along with technical specifications and DeviceNet information and objects for the module. You can view or download Rockwell Automation publications at http:/www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. Rockwell Automation Publication ENMON-IN360F-EN-P - February 2014 11

Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support you can find technical and application notes, sample code, and links to software service packs. You can also visit our Support Center at https://rockwellautomation.custhelp.com/ for software updates, support chats and forums, technical information, FAQs, and to sign up for product notification updates. In addition, we offer multiple support programs for installation, configuration, and troubleshooting. For more information, contact your local distributor or Rockwell Automation representative, or visit http://www.rockwellautomation.com/services/online-phone. Installation Assistance If you experience a problem within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running. United States or Canada 1.440.646.3434 Outside United States or Canada Use the Worldwide Locator at http://www.rockwellautomation.com/rockwellautomation/support/overview.page, or contact your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to help ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Outside United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Allen-Bradley, LISTEN.THINK.SOLVE., Rockwell Software, Rockwell Automation, RSNetWorx, and XM are trademarks of Rockwell Automation, Inc. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication ENMON-IN360F-EN-P - February 2014 Supersedes Publication ENMON-IN360E-EN-P - October 2012 PN-210603 Copyright 2014 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.