Fused Connection Units

Similar documents
Power Socket Outlets

3 Pole & Fan Isolation Switch

INTEGRATED LED DOWNLIGHT IP65 FIRE & ACOUSTIC RATED WITH FLEXI-DRIVER

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

Installation & Operating Instructions

Emergency Assist Alarm Kit Single Zone

Whats in the box. NS1002-E Installation Guide Rev 1.0

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

THERMASREG TR 040 THERMASREG TR 060

Electrisaver User and Installation Instructions

INSTALLATION AND OPERATION MANUAL

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

TIMEGUARD WEATHERSAFE OUTDOOR POWER RANGE INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Technical Data. Dimensions

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Residual Current Devices

best practice guide BS EN 12320: 2001 Padlocks & padlock fittings to in association with Permission to reproduce extracts from BS EN 12320: 2001

RE-PR3-E-27 3-Phase Panel Mount 27kW

Centrifugal extract and condensation control fans

Meat Slicer Instruction manual

Water heating for your PV system. Installation and user guide. v1.1

Specialist Cleaning System & Long Lasting Residual Disinfection Solution

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

OFFICIAL JOURNAL OF IN VITRO DIAGNOSTIC MEDICAL DEVICES DIRECTIVE (98/79/EC)

P R O D U C T D ATA S H E E T

Datasheet - AZM 161SK-12/12RK-024

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 226/03)

Electronic Dual Cylinder Thermostat Installation Instructions

AP-EH500-L/RQA9837. Installation Guide

Extended Range. PRESFIX Packaged Pressurisation Sets AUTOMATIC MAKE-UP UNITS FOR SEALED HEATING AND CHILLED WATER SYSTEMS.

Manual. Electro Plus. Use and Installation ELECTRIC TOWEL HEATER

QFM21... Duct sensors. Symaro. for relative humidity and temperature

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 389/04)

Space Saver. Installation and user manual. Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk. Issue March 2018 smithsep.co.

Portable Sous Vide Instruction Manual

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

SURFACE WARM CEILING HEATERS

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Kentec Electronics Limited Unit Dartford Trade Park Fawkes Avenue Questor Dartford DA1 1JQ United Kingdom

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

DHF Introduction DHF 2

GORILLA HVLS Installation & Maintenance

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

Datasheet - AZM 161SK-12/12RK-024

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

AS/NZS 3133:2008 AS/NZS

ECONOBOOST EB II & EB III Compact Water Booster

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

SAFETY TECH. RRL Pendulum Test >36 (wet test) EN Class DS Bacterial resistance

This second part of the lesson & is dedicated to EMC legal aspect and standards.

P R O D U C T D ATA S H E E T

NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

500 SERIES FOOD WASTE DISPOSERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR 523 SERIES SERIES SERIES 17

360º Surface Mount Ceiling PIR Light Controller

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Auto Drain Installation Instructions.

Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Installation & Technical Guide. Domestic & Commercial.

Electronic 7 Installation Instructions

Technical Specification

CPX RIGID PENDANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Pie Warmer. Instruction manual. Model: GF454-A/GF455-A

Installation, Operation & Maintenance Instructions

>40 80 mm. Dishwasher EN Installation instructions. Appliance components >40. Recess for pipes >80. Front panel/decorative system.

Mechanically operated locks and locking plates

Pressurisation units & expansion vessels

Declaration of Conformity

KM300 Carbon Monoxide Detection System Installation Manual

Clean and fresh air, pure water, captivating greenery, refreshing light, infinite and open nature.

Water heating for your PV system. Installation and user guide. v1.3

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

PARAFFIN SECTION MOUNTING BATH

IMPERIAL FIRES CAST 1 / 2 INSTRUCTIONS IMPERIAL FIRES LTD. SAXON BUSINESS PARK HANBURY ROAD STOKE PRIOR BROMSGROVE B60 4AD

Technical Data. Dimensions

Elers Medical Antimicrobial

SensaGuard TM Integrated Latch Installation Instructions

Auto Drain Installation Instructions.

Wind Alarm Instrument x.x0x

For use with approved Bathstore head kits. Installation guide. Viso Digital installation instructions Page 1

Unipower HPL420. User s Manual. True Motor Power Monitor with... Typical Applications. High Trip Alarm. Low Trip Alarm.

ESCTDEB. Electronic Dual Cylinder Thermostat* User and Installation Instructions. Patent pending

XB-EFA-8L-BK & XB-EFA-8R-BK

Panamatic. Midi & Mini. Installation instructions.

SilvaClean Antimicrobial Laundry Additive

SCHEDULE OF RATES SHEET PRELIMINARIES

Transcription:

Fused Connection Units The smooth modern lines of the Polar accessory plate will fit easily into traditional and contemporary designs alike. Polar Fused Connection Units provide large twin earth terminals as standard, which greatly facilitates wiring and installation. All Polar 13A Fused Connection Units are tested and approved to BS1363 offering assured quality and safety.

Product Range Fused Connection Units With Optional Flex Outlet (Through Bottom) PRW049 3A Fused Connection Unit PRW050 PRW051 PRW052 PRW053 13A Fused Connection Unit 13A DP Switched Fused Connection Unit 13A DP Switched Fused Connection Unit with Neon 13A Fused Connection Unit with Neon PRW049 PRW050 PRW051 PRW052 PRW053 Errors & Omissions excluded. Specification is subject to change without notice. V1.0

Product Dimensional Drawings (mm) Product Inceptor Dimensional Max - Electrical Drawings Parameters (mm) PRW049, 050 PRW053 11 PRW051 60.3 11 PRW052 60.3 15 60.3 60.3 15 Errors & Omissions excluded. Specification is subject to change without notice. V1.0

Wiring Diagrams Product Inceptor Dimensional Max - Electrical Drawings Parameters (mm) Nout Nin Lout Lin LOAD SUPPLY LIN Nin LOUT NOUT LOAD SUPPLY Errors & Omissions excluded. Specification is subject to change without notice. V1.0

Technical Specification Fused Connection Units Material Composition Front Plate, Rocker Switch & Rear Housing: Urea Terminals: Brass Terminal Screws: Steel & Yellow Passivated Internal Mechanism: Formed Press Brass Silver on-lay Copper / Brass Contacts Voltage Current Rating Terminal Size Torque Value 240V~ 50Hz 13A (3A where applicable) 5mm ø 2.5Nm Cable Size 3 x 2.5mm 2 or 2 x 4.0mm 2 Double Pole (051, 052) Twin Earth Back Box Depth Warranty Anti Microbial Certified IP Rating Operational Temperature Yes 25mm - 47mm 20 Years Yes IP20-5 o to +40 o C Standards The Low Voltage Directive 2006/95/EC, Modified ISO 22196 BS 1363-4:1995+A4:2012 (KM10807 Kitemark Licence) Fuses to BS 1362:1973 Additional Information Ensure that the mains supply is isolated before commencing installation and refer to the circuit diagram with the relevant product. Bare earth cables must always be covered with appropriate sleeving and wired to the earth terminal. All white moulded accessories are manufactured using Urea Formaldehyde, which has similar inherent properties to antimicrobial additives that inhibit the growth of infectious diseases. All products were independently tested and achieved a 99.9% kill rate across all four types of the strains of bacteria - MRSA, E-Coli, Salmonella, and Klebsiella Pneumoniae. Errors & Omissions excluded. Specification is subject to change without notice. V1.0

DECLARATION OF CONFORMITY 1. Issuer Name Scolmore International Limited 2. Issuer Address 1 Scolmore Park, Landsberg, Lichfield Road Industrial Estate, Tamworth, Staffordshire, B79 7XB 3. Object(s) of Declaration Polar Range a. Group Fused Connection Units b. Model No. PRW049, PRW050, PRW051, PRW052, PRW053 4. The object of the declaration described above is in conformity with the requirements of the following Legislations: Document No Title 2006/95/EC Low Voltage Directive 5. All products contained within the aforementioned comply with the relevant standards and requirements listed below. KM10807 Kitemark Licence BS 1363-4 : 1995 + A4 : 2012 BS 1362 : 1973 (Fuse) 6. I hereby declare that the equipment named above has been designed to comply with the relevant sections of the above referenced specifications. The unit complies with all applicable Essential Requirements of the Directives. In conjunction with the above all manufacture and process controls are in accordance with ISO 9001:2008 Signed, for and on behalf of: Scolmore International Limited Steven Bettson BSc - Senior Technical Support Engineer 13