RHT RAIL HEATER. Rail & Switch Point Heating System. Pre-Terminated Lengths or Cut-to-Length from the Reel

Similar documents
Rail Network Heat Tracing Applications

DESTU. Direct Entry Sealed Termination Unit. Installation Instructions. Suitable for use in either safe or hazardous areas.

Self-Regulating Point Heating Performance Requirements

F1202 TRACE HEATING. Road & Ramp

Polymer solutions Heating mat EM2-CM

safety, efficiency, reliability and performance.

C Electrical Connection Kit

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

AquiTron. AT-WM Water Monitor DATA SHEET

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

PT9420 (Extended Range)

STATUS ALARM HISTORY ALARM RESET

Hazardous Area Portable Fan Heater The Bulldog

Installation Datasheet

External venetian blinds

OPERATION MANUAL MODEL 4610 ACCELEROMETER

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Cable Actuated Sensor Industrial Incremental Encoder Output

DP86 Constant Voltage with Fitting

Loadstar AC/DC Systems

PT9150 (Extended Range)

Popcorn Warmer Cabinet

OPERATION MANUAL MODEL & ACCELEROMETER

Hazardous Area Portable Fan Heater The Bulldog

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

PT9600. Cable Actuated Encoder Reel. General. Environmental

MSP340 Pressure Transducer

TE Connectivity's AMP NETCONNECT Cable Management

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Neon LED Rope Light Installation Instructions

XL-Trace System Application and Design Guide

MSP100 Pressure Transducer

ENERGY /// RAYCHEM CABLE CLAMPS RAYCHEM CABLE CLAMPS. Quick Reference Guide

Condensing Units CUS 15-60

DOMESTIC STEAM GENERATOR Installation Instructions

Gardian W51. Approvals

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

M7100 Pressure Transducer

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

Union County Vocational - Technical Schools Scotch Plains, New Jersey

OPERATION MANUAL MODEL 805 ACCELEROMETER

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

MODEL 4000A & 4001A ACCELEROMETER

Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

RayClic Connection System

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

VEROTEC Electronics Packaging

Cable Actuated Sensor Industrial User Scalable VDC Output

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

86BSD Digital Output

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Lo-Carbon Quadra Centrifugal Fan

Introduction. Technical Features

GAS MONITOR Model Model

Lamp Supply (Recommended)

FLUEBOOST. flueboost 350 gas fire model

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Firetex steel fire shutters

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery

Fill Point, Level Gauges, and Control Range

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

APPLICATION DATA SHEET

Hazardous Area Portable Fan Heater The Bulldog

RE-PR3-E-27 3-Phase Panel Mount 27kW

AlarmLine Linear Heat Detector

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

OPERATION MANUAL MODEL 8102 ACCELEROMETER

Cable Actuated Sensor Industrial User Scalable 4 20mA

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

M5200 Industrial Pressure Transducer

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

U5700 Submersible Liquid Level Pressure Transducer

Important Notes: Please read carefully before installing your refrigerator.

MODEL 834M1 ACCELEROMETER

Standard SPECIFICATIONS FEATURES APPLICATIONS

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Sub psi SPECIFICATIONS

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

MSP100 Pressure Transducer

PAC1500Xi PORTABLE APPLIANCE CHECKER

INSTALLATION, TESTING and MAINTENANCE

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

COMPONENT SOLUTIONS for the lighting industry

C A Heating Cable Gland Kit

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Transcription:

RHT HEATER Rail & Switch Point Heating System Pre-Terminated Lengths or Cut-to-Length from the Reel

Introduction Rail switch points suffer during the winter months from snow and ice blocking the moving rails and switch point mechanisms, causing failures and subsequent disruption to rail traffic. Existing heating systems vary considerably and can often be inefficient, unreliable, expensive to maintain and operate and generally unsuitable for the rigorous environment associated with rail heating. To combat these problems, Heat Trace Ltd have developed their RHT Rail & Switch Point Heating System. Utilising the latest surface heating technology, a high power, constant watt output heater, together with a highly energy efficient control system, the RHT Rail & Switch Point Heating System is an effective, highly reliable and energy efficient system. Installation The RHT heater can be supplied in preterminated lengths of 3, 4, 5 and 6 metres, fitted with a factory terminated cold lead. These cold leads may be fitted with a moulded 2 pin anti-vibration plug, if required, or supplied plain for connecting into a track-side junction box, or directly into the track-side transformer. The RHT heater can also be supplied in longer pre-terminated lengths up to a maximum of 23 metres (230 VAC) or 11 metres (115VAC). FEATURES & BENEFITS High power outputs up to 200 W/m Supplied in voltages 120VAC or 240VAC Flexible yet robust construction Parallel resistance - constant watt output Pre-terminated, or cut-to-length from the reel One heater for all applications Reduced stocking levels Compatible with existing connections and controls systems Reduced operating costs (when POWERMATCH system included) Competitively priced Alternatively, the heater may be cut to length from the reel then terminated and installed with the minimum of effort. This facilitates a simple one product stocking capability. No special equipment is required. Design The RHT Systems contain all the items necessary to provide protection against snow and ice for switch points, swing nose crossings, switch diamonds, braking areas and high speed curves. The heaters may be fitted at the base of the rail, or under the top flange, depending on the rail profile, track fittings, or user preference. The heaters apply heat directly to the rail - the most effective way to prevent snow and ice build up. The RHT heater is jacketed in a continuous aluminium extrusion offering a high degree of mechanical strength, yet retaining more flexibility than other metal sheathed heaters. For third, or live contact rail heating, an optional additional fluoropolymer outer sheath is available. (Also - See separate data sheet for CRH Self Regulating Contact Rail Heater - as used for Chicago Transit Authority 600 volt dc contact rail.) The specially designed heavy duty rail clip ensures continuous close contact with the rail, providing a highly effective and efficient system. Controls The control system utilises automatic controllers that activate the switch point heating according to local weather conditions using a combination of rail temperature, precipitation and snow sensors. Optional remote monitoring provides automatic defect reporting to assist in providing an effective preventative maintenance strategy. The unique POWERMATCH Controller can reduce annual operating costs by as much as 85-90 %. The RHT heater is designed to be compatible with existing control systems and trackside equipment. Heater Positions The RHT heater is suitable for use on both the stock rail and switch rail and can be mounted either at the top or bottom of the rail. Heavy duty clips are available for most rail profiles. STOCK STOCK SWITCH SWITCH Typical Heater Positions Full Product Acceptance for all Components 2

Heater Layout RHT HEATER COLD LEAD COLD LEAD CONNECTION BARREL CLIP BOTTOM CLIP RHT HEATER COLD LEAD COLD LEAD CONNECTION BARREL CLIP TOP CLIP Side Views of RHT Heater on Rail The size of the switch point will dictate the number and length of the RHT heaters deployed. RHT heaters are supplied in a range of lengths - 3m, 4m, 5m and 6m as standard, each fitted with a 2 core cold lead power cable. Heaters may be fitted in sets of 4, 8 or 12, depending on the heated length of the switch point. The heater is usually fitted to both the (fixed) stock rail and the (moving) switch rail. Typical Switch point Layout Heaters Cold Lead Connections The flexible cold lead cable can be connected to a moulded connection block located either in the centre, or at the side of the track. Alternatively, the cold lead may be connected directly into a track-side mounted junction box, or directly into the track-side isolating transformer. The trackside transformer is fed from a suitable local power supply. Track Side Transformer Cold lead cables Control Panel The RHT heater is normally located at the base of the rail using the special heavy duty spring clips provided. Typical heater Clips for use on UIC60 Rail Profile (Where J blocks are used on the rail, as with the old 113A rail profile, the heater is located behind the J block and runs along the bottom flange. Where it is not possible to locate the heater behind the J block, top rail clips may be used to position the heater along the top flange of the rail.) A barrel clip is used to secure the cold lead connection to the rail. All RHC rail clips are approved for use with rail and switch point heating applications. Their robust design means: Excellent weathering resistance. Resistance to corrosion by chemicals. High electrical insulation properties giving protection against bi-metallic contact corrosion. Top Rail Clip Barrel Clip for Cold Lead Connection Bottom Rail Clip Clips are available to suit most rail profiles currently in use 3

Control System 230VAC 50Hz CB1 6A MCB1A 40A KWH METER Control Systems will vary, depending on the complexity of the system. Control systems may be for a single switch point, or multiple switch point systems, with or without remote monitoring capabilities. 1 2 1 2 OFF AUTO MANUAL C1 C1 MCBB1 MCBB3 MCBC3 MCBC5 AR CT1 C1 DUAL OUTPUT TRANSFORMER The control cubicle generally contains, as a minimum, the following items of equipment: 4 ICELERT 407M (See seperate wiring diagram) 3 C1 JUNCTION BOX ICELERT MONITORING TERMINALS SNOW PRECIPITATION DETECTOR SENSOR HEATERS ON HEATERS OFF COLD SENSOR HOT SENSOR MCBC1 AR VOLT FREE COMMON ALARM AR COMMON ALARM MCB B MCB B2 MCB B3 MCB B4 MCB B5-10% MCB B6 0V -7.5% 110V -5% 0V -2.5% MCB C1 110V +2.5% MCB C2 SCREEN CORE MCB C3 MCB C4 MCB C5 MCB C6 B1 B2 B3 B4 B5 B6 C1 C2 C3 C4 C5 C6 a) an isolator on the incoming supply. b) a main contactor providing power to a circuit distribution board. c) a weather monitoring control unit. d) an override switch. e) a circuit distribution board (DB1) with MCBs for switch points heating. f) an optional circuit distribution board (DB2) with MCBs for tool transformers. Typical Control Schematic Diagram The Heat Trace control system utilises the Findlay Irvine Icelert controller and associated sensors. This system is already accepted and approved by many rail operators. An electronic weather monitoring device uses precipitation and track temperature sensors to detect weather conditions that could affect the operation of the points. When the environmental conditions deteriorate to pre-determined values the points heating is automatically energised. The monitoring device continues to monitor the temperature of the rails and cycles the switching on and off of the heater circuit to ensure that the rail temperature is maintained throughout the adverse conditions. The Control Cubicle contains the weather monitoring unit and control gear and is supplied from the Supply Cubicle. The control circuits include a manual override facility. An optional facility is a remote monitoring system. The system is used from a remote location to monitor the inputs from the sensors, adjust the settings of the weather monitoring unit and test the system to determine that the heaters are operating correctly. Increased Energy Savings The system may now also incorporate Heat Trace s patented POWERMATCH Controller which is capable of reducing the annual operating cost of switch point heating systems by as much as 85-90%! (For further details, please contact Heat Trace Limited - Transportation Division at Head Office.) Icelert 407M Icelert 386R Precipitation Sensor Rail Sensor POWERMATCH Unit Typical Control Panel 4

System Components RHT Heating Cable The RHT rail and switch point heater is a parallel resistance, constant watt output, high power heater, with an extruded aluminium outer sheath. RHT is available in preterminated lengths with a 2 core flexible cold lead power cable. RHT heaters can supplied with standard pre-terminated heated lengths of 3m, 4m, 5m, and 6m. The cold lead cable can be varied according to the installation requirements of each switch point. RHT is available with outputs of 100W/m, 150W/m and 200W/m RHT can be supplied in pre-terminated lengths up to a max of 23 metres for 230VAC, or 11 metres for 115VAC. Because RHT is a parallel resistance heater, it may also be supplied on the reel and cut to length as required on site. Standard reel sizes are 50 metres and 100 metres. Pre-terminated Heaters Catalogue Ref: 200RHT1-3M/X Catalogue Ref: 200RHT1-4M/X Catalogue Ref: 200RHT1-5M/X Catalogue Ref: 200RHT1-6M/X 3 metre heated length RHT rail heater @ 100W/m, 115VAC, with 6m cold lead (optional moulded anti-vibration plug) As above - but 4 metre heated length As above - but 5 metre heated length As above - but 6 metre heated length Ordering Example Power output (W/m) RHT Heater Voltage (2 = 230V; 1 = 115V) Heated length (m) Cold lead length (m) (plain end) Optional fitted with Anti-vibration plug 200 RHT 2-5M / 6 / AVP Reel Stock Catalogue Ref: 200RHT1-XXR Catalogue Ref: 150RHT1-XXR Catalogue Ref: 100RHT1-XXR 200W/m RHT rail heater, 115VAC XXR - denotes reel length in metres as above but 150W/m as above but 100W/m Catalogue Ref: 200RHT2-XXR Catalogue Ref: 150RHT2-XXR Catalogue Ref: 100RHT2-XXR 200W/m RHT rail heater, 230VAC XXR - denotes reel length as above but 150W/m as above but 100W/m 5

System Components RHT Rail Clips RHC rail clips are pressed from high quality CS70 spring steel strip, of 1.64mm thickness. Where fixings comprise two or more components, attachment is made using 430 gauge stainless steel rivets. RHC rail clips are coated with a combination of DELTA-Tone and DELTA-Seal finishes. The result is an extremely durable zinc rich base, coated with an organic resin sealant. Benefits are: Excellent weathering resistance. Resistance to corrosion by chemicals. High electrical insulation properties giving protection against bi-metallic contact corrosion. All RHC rail clips are approved by UK rail authorities for switch point heating applications. Catalogue Ref: RHC001HT Catalogue Ref: RHC013HT Catalogue Ref: RHC002HT Bottom rail clip, designed to hold the heater securely in position in base angle of rail and flange. For rail types: BS110, BS113, UIC54, UIC60 As above - but for rail type: UIC60B As above - but for rail type: UIC54A Catalogue Ref: RHC007 Top rail clip, designed to hold the heater securely in position under the top flange of the rail. For rail types: BS110, BS113, UIC54 Catalogue Ref: RHC004HT Catalogue Ref: RHC014HT Barrel clip, designed to hold the heater cold lead connection securely in position on rail For rail types: BS110, BS113, UIC54, UIC60 As above but for UIC60B (switch rail) Catalogue Ref: RHC005HT As above - but for rail type: UIC54A Catalogue Ref: RHC006HT As above - but for rail type: UIC54B NOTE Clips are available for the majority of rail profiles currently in use internationally 6

System Components RHT Connecting Blocks Anti-vibration, plug-in moulded socket block system for RHT rail heater complete with galvanised steel plate protection covers. Totally waterproof offering long term reliability. Quick installation facility reduces connection time. A system approved by UK rail authorities for switch point heating systems. Connector blocks can be supplied in kit form for localised assembly, or with pre-moulded 8 core cables with lengths of 7 metres to 60 metres Catalogue Ref: 4WAY/8C-1.5 4 way connector block for 8 core 1.5sq.mm cable Catalogue Ref: 4WAY/8C-4.0 4 way connector block for 8 core 4.0sq.mm cable Catalogue Ref: 8WAY/8C-1.5 8 way connector block for 8 core 1.5sq.mm cable Catalogue Ref: 8WAY/8C-4.0 8 way connector block for 8 core 4sq.mm cable Note All blocks, both 4 way and 8 way, are generally supplied with moulded in cables, as shown here and fitted with 7 metres of cable. RHT Control Systems Control Systems will vary, depending on the complexity of the system. Controls systems may be single switch point, or multi-switch point systems, with or without remote monitoring capabilities. A typical control cubicle contains the following items of equipment: a) an isolator on the incoming supply b) a main contactor - which is energised by the weather monitoring control unit and provides power to a circuit distribution board c) a weather monitoring control unit d) an override switch e) a circuit distribution board with MCBs for switch points heating (DB1) f) an optional circuit distribution board with MCBs for tool transformers (DB2) FULL DETAILS OF CONTROL SYSTEMS ARE AVAILABLE ON REQUEST 7

Presented by: Mere's Edge, Chester Road, Helsby, Frodsham, Cheshire, WA6 0DJ, UK. Tel: +44 (0)1928 726 451 Fax: +44 (0)1928 727 846 www.heat-trace.com The information given herein, including drawings, illustrations and schematics (which are intended for illustration purposes only), is believed to be reliable. However, Heat Trace Ltd makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. Users of Heat Trace Ltd products should make their own evaluation to determine the suitability of each such product for specific applications. In no way will Heat Trace Ltd be liable for any damages arising out of the misuse, resale or use of the product.