Section 11. Heating and Ventilation. Heating & Ventilation Systems. 1 of 6

Similar documents
Pressurization System

Environmental Systems

CIRRUS AIRPLANE MAINTENANCE MANUAL

United States Army Warfighting Center Fort Rucker, Alabama SEPTEMBER 2006

DC3Training.com N28AA DC-3 Pilot s Handbook

CHAPTER 11 AIR CONDITIONING

T-6B Electrical System. Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.

HEATER, AIR CONDITIONER AND VENTILATION

DASSAULT AVIATION Proprietary Data

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

TK-1001, 1101, 1201, 1301, 1601

Dash panel insert. Display symbol. Designation/definition symbol. Electronic immobiliser Lamp comes on when unauthorised car key is used

SAFETY INFORMATION NOTICE

Climate Control INTRODUCTION RECOMMENDED OPERATION

Model DDX Deluge Valve

COOPERATIVE PATENT CLASSIFICATION

CABINET PARTS REFRIGERATOR

SECTION 6-15 FIRE PROTECTION

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

7ED27DQXDN01 GABINETE

VENTILATION, HEATING AND AIR CONDITIONING*

CIRRUS AIRPLANE MAINTENANCE MANUAL

CABINET PARTS For Models: GD22DFXFW01, GD22DFXFN01, GD22DFXFB01 (White) (Almond) (Black)

CHAPTER 21 AIR CONDITIONING

AE October 1965 Reformatted October Hot Gas Bypass Control Systems

T0158_ATRcouvDEF_SYSTEM42notPEC.indd COUV1 19/05/10 16:29

HEATING AND VENTILATION

Plant Growth Cabinets

CABINET PARTS For Models: ED25UEXHW01, ED25UEXHT01 (White) (Biscuit)

TECHNICAL DATA. model c-2

C I R R U S HEATING DESCRIPTION A. Cabin Air Heating System - Serials thru

Hazardous Material Safety Program

CIRRUS AIRPLANE MAINTENANCE MANUAL

CABINET PARTS REFRIGERATOR. For Models: ED5VHGXMQ00, ED5VHGXMT00, ED5VHGXMB00 (White) (Biscuit) (Black) 8 03 Litho In U.S.A. (kdj)

CHAPTER 11 HEATING AND VENTILATION

MJC Cartridge Filter Unit Operation & Maintenance

CiciBoilerRoomsis yoursourceforboilerand burnerreplacementparts!

Front Roller (2) Screw Roller (Rear) (2) Screw Clip, Grille Screw Shim

WHIRLPOOL REFRIGERADOR GS2SHGXLQ01

Indirect gas-fired air heater

SEA FROST SHORE ASSIST SA-1 R-12 THIS MANUAL IS SUPPLEMENTAL TO THE SEA FROST R-12 ENGINE DRIVE MANUAL INSTALLATION INSTRUCTIONS

40E ELECTRIC FAN HEATER

CABINET PARTS REFRIGERATOR. For Models: GD2SHAXKQ03, GD2SHAXKT03, GD2SHAXKB03 (White) (Biscuit) (Black) 5 02 Litho In U.S.A. (mek) 1. Part No.

ATEX DRUM HANDLING SYSTEM

CABINET PARTS For Models: ED5LHEXTD00 (Universal Silver)

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

Canadair Regional Jet 100/200 - Lighting

CABINET PARTS. For Models: ED5SHAXMQ00, ED5SHAMXT00, ED5SHAXMB00 (White) (Biscuit) (Black) REFRIGERATOR. Part No Rev.A

CABINET PARTS. REFRIGERATOR For Models: KSRB22FHWH01, KSRB22FHBL01, KSRB22FHSS01, KSRB22FHBT01 (White) (Black) (Stainless Steel) (Biscuit)

Use of energy recovery systems in air conditioning, ventilation or screening

CIRRUS AIRPLANE MAINTENANCE MANUAL

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

COMPONENT MAINTENANCE MANUAL INDEX. Aug 2013

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Powers TM Controls TH 188 Unit Mounted Thermostat

Components for solar heating systems

generic moving map with bezel removed Avidyne Entegra MFD for Piper or Cirrus aircraft Avidyne Entegra PFD for Piper or Cirrus aircraft

2005 Dassault Falcon 900DX S/N 601

40E ELECTRIC FAN HEATER

CABINET PARTS For Models: KSRG22FKWH17, KSRG22FKBT17, KSRG22FKBL17 (White) (Biscuit) (Black)

BERMAD Fire Protection

OP44-1 REV 2: Removed depiction of air intake hole in the CB-907A Right Aft Case Baffle.

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

CABINET PARTS REFRIGERATOR. For Models: ED25PQXFW00, ED25PQXFN00 (White) (Almond) Litho In U.S.A. (mdg) 1. Part No

A/C-HEATER SYSTEM - MANUAL

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

USER AND MAINTENANCE MANUAL

CABINET PARTS For Model: ED5GTGXNQ14, ED5GTGXNB14 (White) (Black)

Automatic Condensate Drains ECO DRAIN Series

CABINET PARTS For Models: GS6SHAXKQ01, GS6SHAXKT01, GS6SHAXKB01, GS6SHAXKS01 (White) (Biscuit) (Black) (Stainless Steel)

CABINET PARTS For Models: ED5RHEXNL00 (Stainless VCM)

182T and T182T Air Conditioning System ICA Revision: Date: 17 September, 2008

REPAIR PARTS LIST. Model Nos (White On White) (Bisque) (Black) (Graphite) REFRIGERATOR

1956 FORD F-100 TRUCK

Development of multi-function CO2 Heat Pump Water Heater

Chapter 10. HVAC System

HRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series

Contour TM Screw Compressors

Broom 370. Location Solent, United Kingdom. Dimensions

Comfort. Description. Applications

Engine Fire Protection System

COMPAC GEN II HEAT/COOL VUX-A. an ISO 9001:2008 Registered Company #10 SUCTION HOSE COMPRESSOR #8 DISCHARGE HOSE EVAPORATOR DRIER CONDENSER

Permission granted to reproduce for educational use only. Describe the problems caused by excess

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

Instruction Manual. B Issue B. next Pump Accessories

Front Roller (2) Screw Roller (Rear) (2) Screw Clip, Grille Screw Insert, Air

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

CABINET PARTS For Models: 7GS2SHEXPQ03, 7GS2SHEXPL03 (White) (Stainless VCM) REFRIGERATOR

Installation, start-up use and maintenance manual

Installation Instructions Air Sourced 310 Heat Pump Module

Dornier 328Jet - Lights

ZERO AIR GENERATOR MODEL 7000 INSTRUCTION MANUAL

Instrument and Control Panels

CABINET PARTS. For Models: GD2SHAXNQ00, GD2SHAXNT00, GD2SHAXNB00, GD2SHAXNS00, GD2SHAXNL00 (White) (Biscuit) (Black) (Stainless Steel) (Stainless VCM)

Introduction to Pharmaceutical Freeze Drying

Figure 1. Ejector cross-sectional drawing. Figure 2. Precondenser to left of vacuum flasher. pressure.

Transcription:

Heating and Ventilation 1 of 6

HEATING AND VENTILATION SYSTEM General Ambient air, drawn in by a fan through a vent in the cowling above the cockpit is mixed with hot air (P2), tapped from the engines, and distributed by pipelines to the cockpit and cabin. Fresh air for the passengers is admitted by a scoop on each side of the aircraft, just aft of the pilot s doors, and passes through the trim panels to the individual louvres above each passenger's head. A vent just forward of the front windscreen can be operated by a handle in the cockpit to allow fresh air into the cockpit if desired. Each pilot s door is fitted with a sliding window. A 3-phase AC fan can be switched on to supply ambient air through the heater distribution pipelines if required. Fixed vents in the upper rear side walls of the cabin extract the air and ensure the flow through the aircraft. Controls and Indications Three controls are fitted on the overhead panel as shown in Figure 1. 1. A rotary temperature control knob, which automatically switches on the fan when moved from its COLD/ position. 2. A sliding distribution lever which can be set in 3 positions. Aft (), Centre (COCKPIT & CABIN) and Forward (COCKPIT ONLY). This lever controls a flap valve in the distribution pipelines by a teleflex control. 3. A ventilation switch on the left-hand side of the overhead panel to allow the fan to be ON when the temperature controller is at COLD/. The control for the cockpit ventilation flap is fitted to a cross member just above the instrument panel. COCKPIT & CABIN HOT COLD COCKPIT Heater Distribution Control Lever Regulator & Fan Control Micro-Switch VENTIL ON Fan Control Switch Figure 1 Heater Control Component Locations 2 of 6

Distributor Control Rod Thermostat Control Mechanism Pilots Diffuser Stale Air Evacuation Line Autopilot Hydraulics Heating Diffuser De-misting Diffuser Front Fresh Air Vent Heating-Ventilation Lower Diffuser Lower Cabin Diffuser Unit Upper Cabin Diffuser Unit Figure 3 Heat Distribution & Airframe Components 3 of 6

Limitations Because the heater draws compressor air from the engines, it must be switched for take-off and landing. Distribution The hot air from the engines compressors passes through a non-return check-valve to the regulation valve on the transmission decking. A pressure-reducing valve fitted to the regulation valve produces a control pressure to operate the system. When the regulation valve is opened the hot air passes forward to the mixing chamber where it is ejected into the ambient air drawn in by the fan. A thermostat downstream of the mixing chamber cuts off the hot air if the temperature reaches 90 C. The distribution pipelines direct the air to the four outlets in the bottom of the cabin, the pilots individual overhead louvres, the Autopilot hydraulic unit in the broom cupboard, the windscreen de-misting diffusers and the lower screen de-misting diffusers. The supply to the cabin can be cut off by means of the sliding control in the cockpit when not required. Electrical Power Supplies The fan is powered by 3-phase 200V 400 Hz AC current from Primary AC bus bar (CB HEATING VENTIL). The control DC supply for the fan contactor is from Secondary DC bus 2PP5 (CB HEATING VENT). System Operation Refer to Figure 3. With the temperature control valve in its COLD/ position the micro switch (39H) is open and the needle valve is off its seat allowing the control pressure (reduced P2 air pressure) to flow away via the vent to atmosphere. There is therefore no control pressure acting under the diaphragm (3) and the regulation valve is closed preventing P2 air from passing through to the ejector and into the mixing chamber. Should the fan switch (43H) now be made the contactor relay (40H) will be energised and the AC contactor made thus motoring the fan and blowing fresh air through the distribution pipelines. When the temperature control valve is turned towards the HOT position the cam on the valve makes the micro-switch (39H) and the fan starts running. Rotating the control closes the needle valve, reducing the leak of control P2 pressure. The pressure under the diaphragm (3) increases lifting the regulation valve off its seat and allowing hot air to pass through to the mixing chamber. Thus, the more the rotary control is turned, the more control pressure is increased and the more hot air is allowed through. The temperature of the hot air passing through the distribution pipelines depends entirely upon the setting of the rotary valve. To prevent overheating of the system a thermostat is fitted just downstream of the mixing chamber. Should the temperature exceed 90 C the thermostat valve opens and the control pressure leaks away thus closing the regulation valve under action of the return spring (2). If the rotary control is not in the COLD/ position when starting the engines fuel fumes will enter the heating ducts and pass into the cabin. To overcome this problem, when the start button is pressed, relay (48H) is energised and continues to be energised for 45 seconds after starter cut-out, giving an earth for the supply through the windings of the solenoid valve (47H). The solenoid valve is energised, opening the needle valve and the control pressure is vented to atmosphere. The regulation valve therefore, remains closed and no P2 air gets through to the distribution lines during this period. The Distribution Controller in the cockpit operates the Distribution Flap, which closes off the supply completely when the control is in its aft position. In the intermediate position the air is distributed to cockpit and cabin and in the forward position only the cockpit is supplied. 4 of 6

Starter Push-Button + 2PP5 P2 Air Double Check- P2 Air T : 45 sec To Other Consumers To Other Consumers 48 Regulation Fan Switch 43 1XP1 3-PHASE 1 2 Air Filter Pressure Reducing (Monitors control P2 air flow rate) 40 3 vent 47 Fresh Air Fan Mixing Chamber Temp Control Closed Thermostat 39 vent Needle Opens at 90ºC Warm Air Distribution Controller vent Warm Air Distribution Flap Key to Figure Cockpit Only Cockpit & Cabin 1. Regulation Body 2. Return Spring 3 Di h Figure 3 Heater Operation 5 of 6

P2 Air Bleed From Engines Solenoid Pressure Reducing Double Check- Fan Air Intake Mixing Duct & Thermostat Fan Regulator Filter Figure 4 Heater Components 6 of 6