Rapid-VIDITEST Calprotectin Card

Similar documents
RIDA TUBE Calprotectin

PIFA PlussPF4 RAPID ASSAY TRAINING QUIZ

PIFA Heparin Platelet Factor 4 ( PIFA HPF4 ) Rapid Assay IQCP QUIZ. 1. How would a technician verify their PIFA HPF4 device is within expiration?

ELISA Plate Washer MICRO WASH 1100 Page 1 of 29

QUICK MANUAL. In-vitro Diagnostics PT10V. c 2017 Samsung Electronics All rights reserved. For Veterinary use only

User Manual MICRO PLATE WASH. Page 1 of 40

Thermo Scientific KingFisher Total RNA Kit Instruction Manual Rev. 1.2

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE GUIDANCE EXECUTIVE (GE)

Thermo Scientific KingFisher Viral NA Kit Instruction Manual Rev. 1.2

c-series Water Bath Additive

Thermo Scientific Wellwash Versa User Manual. Rev. 1.0

Technical Update TAA.TU rev. 1

Thermo Scientific Wellwash User Manual. Rev. 1.0

PRODUCT INFORMATION IMPORTANT SAFETY INFORMATION PROGRAMMING MAINTENANCE TROUBLESHOOTING PARTS LIST WIRE DIAGRAMS

Sensors and Switches in Medical Chemistry and Immunoassay Analyzers

Zoom HT Microplate Washer. The Fastest Microplate Washer For The Life Sciences

HydroFlex FLEXIBLE AND RELIABLE MICROPLATE STRIP WASHING AND VACUUM FILTRATION IN A COMPACT, MODULAR PLATFORM. 21 CFR Part 11* 98/79/EC IVD-D*

PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance

Product Guide for Ludger Clean Post-endoglycosidase and Post-exoglycosidase Clean-up Plate

Models Product Information. Important Safety Instructions REV

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106

INFECTION PREVENTION AND CONTROL ON LINEN AND LAUNDRY MANAGEMENT. ROSAFE E. PERALTA, RN, MAN Chief Nurse MARYMOUNT HOSPITAL

Laird Thermal Systems Application Note. Bi-directional Microcontrollers Monitor and Protect Medical Equipment

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Thermo Scientific KingFisher Pure RNA Plant Kit Revision 1.0

This policy has been adopted by UNC Health Care for its use in infection control. It is provided to you as information only. Infection Control Manual

NON-TOUCH THERMOMETER User Manual

BIO-SPECTRUM TREATMENT DEVICE

Jennings Street School

Inherent Factors Affecting Soil ph. Soil ph Management

PC71 American Style Fridge Freezer

Thermo Scientific KingFisher Pure RNA Tissue Kit Revision 1.0

REQUIRED EQUIPMENT FOR ALL FOOD SERVICE ESTABLISHMENTS:

No Touch Thermometer

POLYMIX PX-IG 2000 Operating Instructions

THE COMPACT CENTRIFUGE: OPERATOR 1

SAFETY ACTION NOTICE By arrangement with NSS Health Facilities Scotland

Commit 2 Clean TM/MC. Bloodborne Pathogens Awareness Program

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

Pilot Freeze Dryers Smart Processes

Issued $2.50. DuraPark Type A2LS. Heavy-Duty Drum Brake Assembly. Maintenance Manual MM Supersedes Lucas Catalog No. XDA911 (July 1995)

$100 $100 $100 $100 $100 $200 $200 $200 $200 $200 $300 $300 $300 $300 $300 $400 $400 $400 $400 $400 $500 $500 $500 $500 $500

Drenches of Entomopathogenic Nematodes for Control of Fungus Gnats in Poinsettia Liners

Rain Forest Quick Guide

BLOOD BANKING AIISHIL" BLOOD BANK FREEZERS :

Recirculating Coolers

Inherent Factors Affecting Soil ph. Soil ph Management

LAB SAFETY FOR CUSTODIANS

Thermo Scientific KingFisher Pure RNA Blood Kit Revision 1.0

HydroSpeed plate washer for 96- and 384-well formats

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 389/04)

METHOD OF TEST FOR PREPARATION OF MARSHALL SPECIMENS 3. APPARATUS. Canadian Council of Independent Laboratories June 2016 LS-261 R27 ASTM D

CLEANING AND SANITATION Policy Owner: Erica Tennessen Policy Originated by (program or department): Program Applicable Programs: All Programs

HydroSpeed plate washer for 96- and 384-well formats

HI COD REACTOR and Test Tube Heater 2008 Series

MD-MINI Dry Bath. Instruction Manual

Applicable To Employees of the Gundersen St. Joseph s Hospital laboratories and Gundersen Tri-County Hospital laboratories.

Intro. of particular standards for IEC : rd edition 14 MARCH 2017

OPERATING INSTRUCTIONS

RNAscope LS 4-plex Fluorescent Assay

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

FW422 Integrated In Column Larder Fridge Manual for Installation, Use and Maintenance

CELITRON COMPACT SOLUTION FOR BIOHAZARD WASTE DISPOSAL Integrated Sterilizer and Shredder (ISS)

Compresstome VF-300-0Z User Manual

I N S T R U C T I O N S

Best Freeze Drying Solutions

9420* & * Coin Operated Models C* Commercial Models. Product Information. Important Safety Instructions

Zoom Microplate Washer and Washer-Dispenser. Reliable Solutions for Your Daily Work

Environmental Cleaning Tool Kit

ALLERGEN MIXING ASSISTANT

ELISA NIMBUS. Automated ELISA Processing System

CONGRATULATIONS ON CHOOSING THE WATERLOGIC 4 FIREWALL YOUR WATERLOGIC WATER DISPENSER

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 226/03)

Effective Date: 0 8 / 1 0 / 1 7. Replaces: 08/11/16. Formulated:1997 SPECIAL (MEDICAL) WASTE MANAGEMENT

Slide 1. Welcome to the on-line training course for Waste Management!

NIOX MINO External Quality Control

Introduction to Pharmaceutical Freeze Drying

Operation Manual PM-NIT-14006E

Absorbance range Resolution Accuracy Type of microplate Wavelength Optic system Light source Wavelength accuracy. Calculation method

Table of Contents. English

CHECKLIST NUTRIENT MANAGEMENT

Certificate of Compliance Section 1 - PRODUCT AND COMPANY IDENTIFICATION

THE UNIVERSITY OF NEWCASTLE- SCHOOL OF BIOMEDICAL SCIENCES ASHMAN LABORATORY

OFFICIAL JOURNAL OF IN VITRO DIAGNOSTIC MEDICAL DEVICES DIRECTIVE (98/79/EC)

Professional appliances - BW-REC

Operating Instructions

An Automated SPE Procedure and Analysis for the Extraction of Chlorpromazine and Thioridazine from Plasma Application Note 213

Owner s Manual. Model PH050006

INSTRUCTION MANUAL. operates with ISO9001 certified quality system. TECSYSTEM S.r.l Corsico (MI) Tel.: Fax:

VP, Facilities and Construction Management

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Rondo BENCHTOP INSTRUMENTS. Masters of precision

Thermo Scientific iems Incubator/Shaker HT User Manual

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

(Text with EEA relevance) First publication OJ EN 12322:1999/A1: Note 3 Date expired ( ) 19.8.

LAUNDRY POLICY Page 1 of 6 Reviewed: February 2017

INSTRUCTION MANUAL. operates with ISO9001 certified quality system. TECSYSTEM S.r.l Corsico (MI) Tel.: Fax:

STANDARDD OPERATING PROCEDURE FOR THE LUMINEX

Transcription:

Rapid-VIDITEST Calprotectin Card One Step Calprotectin Card Test. Instruction manual Producer: INTENDED USE: The Rapid-VIDITEST Calprotectin Card test is a rapid chromatographic immunoassay (non-invasive assay) for the qualitative detection of calprotectin in human feces specimens, which might be useful for the diagnosis of inflammatory gastrointestinal disorders. INTRODUCTION: Calprotectin is a calcium-containing protein that makes up 5% of the total protein and 60% of the cytosolic protein of neutrophil. It has bacteriostatic and fungistatic properties and is found in feces at levels six times higher than that in plasma. That fecal biomarker is useful to assess the activity of inflammatory bowel disease (IBD). IBD includes Crohn's Disease (CD) and Ulcerative Colitis (UC) and are associated with elevated neutrophils. This fecal calprotectin assay is useful in differentiating organic (IBD) from functional gastrointestinal disease (IBS: Intestinal Bowel Syndrome). It is a simple, non-invasive biomarker that is especially useful in children, who may require general anesthesia for colonoscopy. And this fecal calprotectin detection can predict relapse. PRINCIPLE: The Rapid-VIDITEST Calprotectin Card is a qualitative immunoassay for the detection of calprotectin in feces samples. The membrane is pre-coated with monoclonal antibodies against calprotectin on the test lines region. During testing, the sample reacts with the particles coated with anti-human calprotectin antibodies which were pre-dried on the test strip. The mixture moves upward on the membrane by capillary action. In the case of a positive result the specific antibodies present on the membrane will react with the mixture conjugate and generate colored line. A green colored band always appears in the control line and serves as verification that sufficient volume was added, that proper flow was obtained and as an internal control for the reagents. MATERALS PROVIDED: - Rapid-VIDITEST Calprotectin Card tests - Instructions for use - Specimen collection vial with buffer 1

MATERIALS REQUIRED BUT NO PROVIDED: - Specimen collection container - Disposable gloves - Timer SPECIMEN COLLECTION AND PREPARATION: Collect sufficient quantity of faeces (1-2 g or ml for liquid sample). Stool samples should be collected in clean and dry containers (no preservatives or transport media). The samples can be stored in the refrigerator (2-4ºC/36-40ºF) for 7 days prior to testing. For longer storage the specimen must be kept frozen at 20ºC/-4ºF. In this case, the sample will be totally thawed, and brought to room temperature before testing. PROCEDURES: To process the collected stool samples: Use a separate vial for each sample. 1. Unscrew the cap of the vial and introduce the stick three times into the fecal specimen to pick up the sample (1). Close the vial with the buffer and stool sample. This vial with the sample can be storage during 5 days. 2. Shake the vial in order to assure good sample dispersion (2). For liquid stool samples, aspirate the fecal specimen with a dropper and add approx. 10-20uL into the specimen collection vial with buffer. Test Procedure: Allow the tests, stool samples and buffer to reach to room temperature (15-30ºC/59-86ºF) prior to testing. Do not open the pouch until ready to perform the assay. 1. Remove the Rapid-VIDITEST Calprotectin Card from its sealed pouch and use it as soon as possible. Place in a clean and flat surface. 2. Shake the specimen collection vial to assure good sample dispersion. Break off the tip of the vial (3). 3. Use a separate device for each sample. Dispense 4 drops or 100 µl into the specimen well (S) (4). Start the timer. 4. Read the result at 10 minutes after dispensing the sample. 2

INTERPRETATION OF RESULTS: GREEN RED RED Negative Positive Invalid Invalid POSITIVE: Two lines appears across the central window, in the result line region (red test line marked with the letter T) and in the control line region (green control line marked with the letter C). A calprotectin positive result could be indicative of gastrointestinal inflammatory pathology is present. NEGATIVE: Only one green band appears across the control line region marked with the letter C (control line). A negative results shows that neither active gastrointestinal inflammation is present. INVALID: A total absence of the green control colored band regardless the appearance or not of the red test line. Note: Insufficient specimen volume, incorrect procedural techniques or deterioration of the reagents are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit and contact your local distributor. 3

NOTES ON THE INTERPRETATION OF RESULTS: The intensity of the red colored band in the result line region (T) will vary depending on the concentration of calprotectin in the specimen. QUALITY CONTROL: Internal procedural controls are included in the test: - A green line appearing in the control line region (C). It confirms sufficient specimen volume and correct procedural technique. - A clear background is an internal negative background control. If the test is working properly, the background in the result area should be clear and not interfere with the ability to read the result. LIMITATIONS: 1. Rapid-VIDITEST Calprotectin Card will only indicate the presence of calprotectin in the specimen (qualitative detection) and should be used for the detection of calprotectin in feces specimens only. Neither the quantitative value nor the rate of increase in calprotectin concentration can be determined by this test. 2. An excess of sample could cause wrong results (brown bands appear). Dilute the sample with the buffer and repeat the test. 3. Some stool samples can decrease the intensity of the control line. 4. In the case of patients with active neutrophilic inflammatory bowel diseases such as Crohn s disease and Ulcerative Colitis, would be positive for fecal calprotectin. Rapid-VIDITEST Calprotectin Card could be used for patients with chronic diarrhea. 5. Positive results confirm the presence of calprotectin in fecal samples; nevertheless, it can be due to several causes, inflammatory bowel disease, colorectal cancer and some enteropathies). Positive results should be followed up with additional diagnostic procedures by a physician to determine the exact cause of inflammation. 6. Neonatal fecal calprotectin levels have been reported higher than normal children with a median of 167µg/g. EXPECTED VALUES: Higher levels of calprotectin in the stool are associated with an increased risk of relapse in patients with inflammatory bowel disease (IBD). Some studies established equal or higher 50µg hfcp/g faeces as cut-off value to allow detect adult patients with GI inflammatory problems. PERFORMANCE CHARACTERISTICS: Sensitivity A sample containing calprotectin at concentration equal to or higher than 50µg/g faeces produces positive results when using Rapid-VIDITEST Calprotectin Card test. Different calprotectin dilutions were tested directly in the extraction buffer or spiked in a negative stool sample in accordance with the kit instructions to determinate the detection limit of the test. The detection of human calprotectin with Rapid-VIDITEST Calprotectin Card test showed >94% of sensitivity correlation compared to another commercial immunoassay (Calprest Eurospital). 4

Specifity The detection of human calprotectin with Rapid-VIDITEST Calprotectin Card test showed 93% of specificity correlation compared to another commercial immunoassay (Calprest Eurospital). The Rapid-VIDITEST Calprotectin Card test is specific for human Calprotectin, showing no cross-reaction with other calprotectins. STORAGE AND STABILITY: Store as packaged in the sealed pouch either at refrigerated or room temperature (2-30ºC/36-86ºF). The test is stable through the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use. Do not freeze. PRECAUTIONS: - For professional in vitro diagnostic use only. - Do not use after expiration date. - The test should remain in the sealed pouch until use. - Do not use the test if pouch is damaged. - Follow Good Laboratory Practices, wear protective clothing, use disposal gloves, do not eat, drink or smoke in the area. - All the specimens should be considered potentially hazardous and handled in the same manner as an infectious agent. - The test should be discarded in a proper biohazard container after testing. - The test must be carried out within 2 hours of opening the sealed bag. REFERENCES: 1. VIEIRA, A. et al., Inflammatory bowel disease activity assessed by fecal calprotectin and lactoferrin: correlation with laboratory parameters, clinical, endoscopic and histological indexes, BMC Research Notes 2009, 2:221. 2. HANAI, H. et al. «Relationship Between Fecal Calprotectin, Intestinal Inflammation, and Peripheral Blood Neutrophils in Patients with Active Ulcerative Colitis Digestive Diseases and Sciences, Sept. 2004, Vol 49, No 9, pp 1438-1443. 3. BONNIN TOMAS, A, et al. Calprotectina fecal como marcador diferencia entre patología gastrointestinal orgánica y funcional. Rev. Esp. de Enf. Dig. 2007, Vol 99, No 12, pp. 689-693. SYMBOLS FOR IVD COMPONENTS AND REAGENTS: In vitro diagnostic device Use by Batch code Manufacturer 5