IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

Similar documents
Inffusers. idl20 (2 WAY) ids60 (4 WAY)

Active Chilled Beams. Technical Data Bulkhead-Mounted Concealed Model With Horizontal Coil and Auxiliary Drain Pan

Active Chilled Beams. Technical Data Concealed Ceiling Mounted Model With Vertical Coil and Integral Drain Pan

DADANCO Technical Paper

Chilled Beam and Radiant Cooling Basics. Salt Lake City, UT ASHRAE Chapter December 2013 Nick Searle

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

Modular Active. Chilled. Beams

A REASONABLE ALTERNATIVE TO CHILLED BEAMS Dan Int-Hout Chief Engineer

ASHRAE JOURNAL ON REHEAT

APPLICATION GUIDE BEAMS

Chilled Beams. Getting a Warmer Reception

Underfloor Air Distribution:

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

Raised Access Floor - (AE Breadth Area)

KLIMA Active Chilled Beams

Displacement Ventilation

The Luxton-Reed Center. Product Showcase

Radiant Exchange in Stratified Environments: Considerations and Challenges for Hourly Energy Simulation of UFAD, DV, and Radiant Cooling Systems

DESCRIPTION OF TECHNOLOGY

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

HVAC Optimization with Cold Air Distribution

Air Conditioning Clinic

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

Adding More Fan Power Can Be a Good Thing

HVAC DISTRIBUTION and DELIVERY SYSTEMS

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Temperature Control and Zoning of UFAD Systems

Dehumidifying with Dedicated Outdoor Air

design brief This design brief provides an introduction into the design and application of DV. It addresses the following issues:

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

CONTROLLED CHILLED BEAM PUMP MODULE

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

UFAD Underfloor air distribution system

PRODUCTS TAO TAO PRODUCT: ADVANCING THE SCIENCE OF AIR DISTRIBUTION. temperature ambient optimizer. Redefine your comfort zone.

Better Air Dispersion for. Underfloor. Plenums

Unico Training. Class for R E Michel Salesmen

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

CHAPTER 4. HVAC DELIVERY SYSTEMS

In accordance with the Department of Labor and Industry s statute , Subd. 11,

NOVEMBER 2012 THE EUROPEAN EXPERIENCE

Appendix 13. Categories of Cooling and Heating systems

installation, operation & Maintenance manual Floor-mounted Induction units

DESIGNING MODULAR VAV SYSTEMS

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

In the past, contractors sized heating and cooling systems GETTING HVAC RIGHT

UNDERFLOOR PRODUCTS E3

Don t Turn Active Beams Into Expensive Diffusers

80-6-ISD A Better Solution for Proper Space Air Distribution

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Active & Passive Beams

Chilled Beams in Labs Eliminating Reheat & Saving Energy on a Budget

maximize displacement ventilation Opportunities

7. MECHANICAL SYSTEM DESIGN

Displacement Ventilation in Classrooms

Rittling Induction Units Catalog

THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units

installation, operation & Maintenance manual acb ceiling-mounted cassette models

Jim Aswegan Chief Engineer

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

CHAPTER IV AIR DISTRIBUTION AND BALANCE

Duct Design and Installation

Electric Duct Heaters. IDHB & IDHC Series

Improved Thermal Comfort & Energy Efficiency with low-pressure VAV diffusion design

High-Performance VAV Systems

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Questions??????? Thank you

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Selected Laboratory Energy Efficiency Measures

DADANCO E U R O P E. Induction unit. Installation, operation & maintenance manual. Induction Units

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

Technical Assignment 3 11/15/04. Executive Summary

SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS FANLESS FILTERLESS SPACE CONDITIONING

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

Space Air Diffusion II

EarthWise System Seminar

Active Chilled Beams

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

HVAC 101. H V A C S y s t e m s

Design Options For HVAC Distribution System. Course Content

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

textile air dispersion products

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

FAN WALL Technology. Product

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

Benefits Offered by Passive Dehumidification Wheel Speed Control

Air Conditioning Clinic

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Welcome to Unico! The Small Duct High Velocity (SDHV) System

HVAC Design Overview of Variable Air Volume Systems

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

VLT 6000 HVAC Application Booklet

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Airex University VAV Applications Displacement Ventilation

2. CURRICULUM. Sl. No.

Transcription:

IDL20e (2 way discharge) IDS60e ( way discharge) Frequently Asked Questions UDI (vertical discharge) Inffusers

INFFUSER FREQUENTLY ASKED QUESTIONS The following are frequently asked questions (FAQ s) on DADANCO Inffusers. To assist you in finding an answer to your question, the FAQ s have been put into the following groupings: 1. Introduction to DADANCO Inffusers 2. Comparing Systems using Inffusers and other Alternatives 3. Heating. Commissioning To gain the most benefit from the FAQ s, please take the time to read them all. This will provide a far better understanding of Inffuser performance. If you have a question that is not covered here, please feel free to contact us at (13) 56-5657. 1. INTRODUCTION TO DADANCO INFFUSERS 1.1 What is an Inffuser? An Inffuser is an induction diffuser that delivers an increased quantity of tempered supply air by inducing secondary room air into the primary air before discharging the mixed supply air through the air outlet to the conditioned space. The air supplied by the central air handler to the Inffuser is called primary air. The primary air is supplied to the Inffuser at a relatively low static pressure (typically 0.1-0.3 w.c.). Within the Inffuser the primary air is discharged from the primary air plenum into a mixing chamber through a series of nozzles. A zone of relative low pressure is created within the mixing area, thereby inducing room air (either directly from the room or from the return air ceiling plenum) into the mixing area. The induced room air is called secondary air. The secondary air mixes with the primary air, and the mixed supply air is delivered to the room through a conventional diffuser outlet. A certain additional amount of room air is aspirated into the supply air at the unit discharge. Induction Primary Air Secondary Air Secondary Air Supply Air Aspiration 1.2 What is the entrainment ratio? Entrainment ratio is the ratio of secondary (induced) air volume to primary air volume. This ratio is typically in the order of 1.0 to more than 2.0 for the Inffuser induction diffusers. When used in VAV systems, the induction ratio remains constant as the VAV unit modulates. 2

1.3 What is the difference between internal and external entrainment? Inffusers can induce the room air either directly from the room through a portion of the diffuser grille assembly (internal entrainment) or indirectly from the ceiling return air plenum (external entrainment). Internal Entrainment 1 External Entraiment 1 2 3 2 3 1. Primary Air 2. Mixing Chamber 3. Secondary Air. Supply Air 1. What types of Inffuser models are available? Many models are available. A sampling of standard model types available include: Square 1, 2, 3 or -way discharge Linear slot 1 or 2-way discharge Under-floor vertical discharge 2 x 2 Foot Foot or continuous slot To match the floor tile sizes As Inffusers use conventional diffusers for the discharge outlet, almost any diffuser can be incorporated into an Inffuser design. 3

1.5 What are common applications of Inffuser induction diffusers? Any air distribution system where an increase in the quantity of supply air delivered to the room at a more temperate temperature is of benefit is a candidate for Inffusers. The Inffuser makes effective use of the ability of the induction nozzles to entrain air from the occupied space, either directly from the room (internal entrainment) or from the return air ceiling plenum (external entrainment) to increase the total supply air delivered to the occupied space. The Inffuser induction diffusers also enable the use of lower primary air temperatures and thereby lower primary air quantities for a given sensible cooling load. The use of 5-50 ºF primary air can reduce the primary airflows by 20-30% as compared to conventional system designs without concerns over cold drafts/dumping, particularly a concern in variable air volume systems at low load, high turndown conditions. The primary air is mixed with the secondary room air and the mixed supply air is discharged into the room at temperatures about 60-65 ºF. With lower primary air temperatures humidity control is much improved through the higher latent cooling capacities, particularly beneficial in variable air volume systems at low sensible load conditions. Air buoyancy is improved in the cooling mode resulting in improved air outlet performance. Also the risk of stratification when in the heating mode is also reduced through the more temperate discharge temperatures. Inffusers are ideal for buildings and zones with low-medium sensible cooling and heating load densities. Common applications include offices, universities, hospitals, schools and libraries for both new construction and existing building renovations. Buildings most affected by space constraints where the reduction in the size of the central air handlers and ductwork system serving the terminal units can greatly simplify and facilitate the installation are also ideal candidates. Finally due to the energy savings possible with Inffusers when used in low temperature systems, probably the most common application is in those buildings that are striving to achieve LEED certification (as developed and administered by the US Green Building Council). Type Application Solution Existing Building New Building Improve the energy performance of an existing VAV or CAV system. Air distribution/movement of the existing system is inadequate and existing ductwork sizes are not large enough to permit supply airquantities to be increased. Cooling capacity of the existing system is inadequate and existing ductwork sizes are not large enough to permit supply air quantities to be increased. Replacement of fan-powered VAV units to eliminate fan energy and VAV terminal maintenance considerations. Displacement system designs requiring higher supply air temperatures where space for primary air ductwork infrastructure is limited. LEED certified designs where lower temperature primary air delivers benefits in fan energy savings and reduced system infrastructure. Where internal zone loads are very low (less than 10 15 BTUH/sq. ft. and good air circulation and good humidity control is required. Replace the existing diffusers with Inffusers. Reduce the primary airflow rate and corresponding temperature leaving the cooling coil to maintain the cooling capacity required. Fan power consumption decreases by the cube of the reduction in primary air flow. Retain the existing ductwork and use Inffusers to increase the supply air quantity and air movement being delivered to the conditioned space. Retain the existing ductwork and reduce the primary air temperature for increased cooling capacity using Inffusers to temper the air being delivery to the conditioned space. Replace the existing VAV terminals with single duct VAV terminals, retaining the existing ductwork, and replace existing diffusers with Inffusers to increase the supply air being delivered to the conditioned space. Design the system for lower primary air temperatures and air quantities using Inffusers to deliver higher supply air temperatures and air circulation rates to the space. Design the system for lower primary air temperatures and air quantities using Inffusers to deliver higher air circulation rates to the space. Design the system with medium temperature (50-55 F) primary air and flow rate of approximately 0.6 cfm/sq. ft. The INFFUSER can increase the air circulation rate in the space to over 1.2 cfm/sq. ft.

2. COMPARING SYSTEMS USING INFFUSERS AND OTHER ALTERNATIVES 2.1 Isn t an Inffuser similar to a high aspiration or swirl diffuser? No. The induction process is significantly different from the aspiration of room air at the diffuser discharge which occurs to a varying extent with all types of diffusers. The amount of air being induced by the Inffuser can be closely controlled and measured by varying the number and size of nozzles within the unit. With the Inffuser the mixing of the primary and room air occurs within the unit before the mixed tempered supply air is discharged into the room. The aspiration process relies on mixing the supply and room air within the room, in essence using the room as a mixing chamber. 2.2 Are the fan operating pressures comparable in systems using Inffusers with those using conventional diffusers? The fan operating pressures are about the same or slightly higher. Inffusers are typically selected at 0.1 0.3 w.c. inlet static pressure. 2.3 Are Inffusers only applicable to systems using low temperature primary air or variable air volume? No. Inffusers are suitable for use in any air distribution system where increased air movement and tempered primary air temperatures would be of benefit. 2. Are Inffusers quieter than typical diffusers? Inffuser noise levels are typically comparable to or lower than conventional diffusers. The DADANCO Inffusers have an added advantage with respect to noise levels through the use of the patented multi-lobed DADANCO nozzles. 2.5 How does the use of low temperature primary air compare with conventional system designs? Both systems will generally have the same installed refrigeration and heating capacities and as a result, common chiller and boiler plants. The main differences are in the air handling systems. With the reduced primary airflows the fan energy savings of low temperature systems using Inffusers can be significant typically 20 30% less. With respect to installed cost of systems using Inffusers, the Inffusers units normally cost somewhat more than conventional diffusers. There are, however, offsetting installed cost savings in the system. The size and cost of the central air handlers and ductwork/risers in the low temperature system are significantly reduced due to the reduction in primary airflows. The cost of the building s overall electrical infrastructure may also be reduced due to lower fan power requirements. Conventional Low Temp w/inffusers Net for Inffusers Installed Costs Central air handlers size Larger Smaller + + Ductwork/risers size Larger Smaller + + Ceiling space required Larger Smaller + + Operating Costs Fan energy Higher Lower + + Refrigeration energy Slightly lower Slightly higher - Pump energy Slightly higher Slightly lower + Comfort Thermal control Same/Slightly Worse Same/Slightly Better + Humidity control Worse Better + + Noise levels Same/Slightly Higher Same/Slightly Lower + Air Movement Lower Higher + + Other Contribution to LEED credits Little Significant + + 5

2.6 To what extent can the fan energy required be reduced with a low temperature primary air system design? For a given sensible cooling load as the primary air temperature is reduced, the amount of primary air needed to satisfy the same sensible cooling load is also reduced. Typically every 2 ºF reduction of the primary air temperature results in a 10% reduction in the primary airflow required to satisfy the same sensible cooling load. % Change in Primary Air Flow 50% 5% 0% 35% 30% 25% 20% 15% 10% 1 ( F ) Change 2 ( F ) Change 3 ( F ) Change ( F ) Change 5 ( F ) Change 6 ( F ) Change 7 ( F ) Change 8 ( F ) Change 9 ( F ) Change 10 ( F ) Change 5% 0% 10 12 1 16 18 20 22 2 26 28 30 32 3 36 Initial Delta T (F) The following example compares the operating conditions of a building zone of 5000 sq. ft. at a room design temperature of 75 F and a peak design sensible cooling load of 20 BTUH/sq. ft. of a conventional VAV system with a system using low temperature primary air. System Comparison of Low Temperature versus Conventional System Designs Fan motor power required at 100% of design cooling load (@ 2.8 w.c. static pressure, 67% efficiency w/drive losses) 6 All-Air VAV System @ 55 F Primary Air Inffuser System @ 8 F Primary Air Inffuser Difference Total primary airflow from the central air handler 605 cfm 310 cfm - 26% Supply airflow to the zone @100% of design cooling load 605 cfm 8289 cfm + 80% Supply airflow rate @ 100% of design cooling load 0.92 cfm/sq. ft. 1.65 cfm/sq. ft. + 80% Supply airflow to the zone @ 60% of design cooling load 2763 cfm 973 cfm + 80% Supply airflow rate @ 60% of design cooling load 0.55 cfm/sq. ft. 1.0 cfm/sq. ft. + 80% Primary duct size (for 0.0089 w.c. duct loss/foot) 35 x 16 (3.9 sq. ft.) 28 x 16 (3.1 sq. ft.) - 20% Central air handler coil face area (@ 500 fpm face velocity) 9.2 sq. ft. 6.8 sq. ft. - 26% 3.0 kw 2.2 kw - 26%

2.7 The major energy savings with the low temperature system designs is in fan power. What is the situation with pumping and chiller energy? If the chillers are providing lower water temperature to provide the lower primary air, the pumping energy required will be somewhat reduced and the chiller energy will be somewhat higher. The pump energy savings and chiller energy increase will be modest compared to the energy savings realized by the central air handlers providing the reduced quantity of primary air. 2.8 Should there be concerns about possible condensation on the face of the Inffuser due to the use of lower temperature primary air? No, as long as the system is designed to provide sufficient latent cooling capacity. The cold primary air is tempered up to a warmer temperature by the room air before being discharged into the room through the diffuser. Laboratory tests were conducted at varying primary air temperatures and room humidity levels. The tests results indicated that with a room design temperature of 75 ºF moisture did not form on the Inffusers face using 6 ºF primary air until the room s relative humidity reached 75%. With adequate latent cooling capacity being provided by the primary air, this condition will not occur. 3. HEATING 3.1 Can Inffusers be used successfully to provide heating from the ceiling or should heat from under-the-window (i.e. finned-tube radiation) be used? This is a common question. The use of overhead heating from the ceiling as opposed to under-the-window heating is dependent on the buildings envelope and not directly related to the choice of an Inffusers. Research tests on this subject compared comfort levels using five alternative methods for distributing the heat as follows: Discharging the heated air horizontally into the room through a one-way slot located at the ceiling above the window Discharging the heated air vertically down the window though a liner slot located at the ceiling above the window Discharging the heated air horizontally both into the room and into the window from a 2-way discharge linear slot located 2 1/2 feet away from the window Radiant ceiling panels located above the window Finned tube radiation located below the window While the results varied depending on the outdoor winter design conditions and the extent of glazing, the results generally indicated that there are no concerns with any of the methods tested if the heat loss along the perimeter is 300 Btu/lineal foot or less. Between 300 and 00 Btu/lineal foot heating from overhead was found acceptable only if the heated air is delivered toward the window horizontally (and hits the window at a velocity of around 75 feet per minute) or from below the window. Above 00 Btu/lineal foot the research found only finned-tube radiation or some other method of delivering the heat from under the window could be used to provide adequate comfort due to down draft issues. This guidance applies not only to Inffusers, but to any system (such as an all air VAV system) when considering the use of overhead versus under-the-window heating.. COMMISSIONING.1 How is the primary airflow to the Inffuser measured during system balancing? The way to accurately measure the primary air flow into the Inffuser is by reading the static pressure from the commissioning sampling tube on the unit. A primary air flow versus static pressure chart is provided for each unit. Do not utilize static pressure readings in the duct near the unit inlet and presume it will be the same as that in the unit s primary air plenum for commissioning purposes. This measurement could be up significantly different from that measured through the commissioned sampling tube. 7

260 North Elm Street Westfield, MA 01085 Ph: (13) 56 5657 Fax: (13) 568 538 www.dadanco.com info@dadanco.com DADANCO MESTEK Joint Venture LLC (DADANCO) is jointly owned by subsidiaries of Dadanco Pty Ltd headquartered in Adelaide, Australia and Mestek, Inc. headquartered in Westfield, MA. Mestek is a diversified manufacturer of HVAC products with sales of over $00m. Mestek s HVAC companies include Smith Cast Iron Boilers, Hydrotherm, RBI Boilers & Water Heaters, Sterling, Vulcan, Airtherm, Applied Air, Anemostat, Air Balance, Arrow United, L. J. Wing, Lockformer and many others. March 2013 8