SPLIT WALL-MOUNTED AIR CONDITIONER

Similar documents
AIR CONDITIONER SPLIT WALL MOUNTED

AIR CONDITIONER CASSETTE

AIR CONDITIONER CASSETTE

SPLIT WALL-MOUNTED AIR CONDITIONER

AIR CONDITIONER CASSETTE

CENTRAL AIR CONDITIONER SPLIT SYSTEM

SPLIT WALL-MOUNTED AIR CONDITIONER

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

INVERTER SPLIT - TYPE

CENTRAL AIR CONDITIONER SPLIT SYSTEM

Installation manual for room air conditioner

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

AIR CONDITIONER CONSOLE

INSTALLATION INSTRUCTIONS

KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

Air Conditioner. user installation & manual manual. imagine the possibilities

Choosing the installation site. Installation. 07 Choosing the installation site

CLIMATISEUR CENTRAL AVEC CONTRÔLE ÉLECTRONIQUE SPLIT SYSTÈME - SÉRIE CD CENTRAL AIR CONDITIONER WITH ELECTRONIC CONTROL

CLIMATISEUR CACHÉ SYSTÈME SPLIT AVEC COMMANDE

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

Installation Manual. WAS / WYS Series. For 9,000-36,000 BTU/hr Systems. Inverter+ and Inverter++ Models

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

42PHW / 42PHQ 42PHQ...K

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

Split Air Conditioner

Saunier Duval Clima, S.A.

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

High Wall Split Air Conditioners 53QHCT KHCT

Reverse Cycle Inverter Split System Air Conditioner

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Air Conditioner Service Manual KSWT SERIES INSTALLATION INSTRUCTION. Wall-mounted Split Type

INSTALLATION INSTRUCTION

Please read this manual carefully before installation and keep it for future reference. CONTENTS. Installation Manual. DIY Series

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

Ductless Split Air Conditioner

Installation Instructions

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER

ROOM AIR CONDITIONER INSTALLATION MANUAL

Installation Manual. SYSPLIT WALL FLEXI Series SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Installation Manual. All Model Numbers SERIES SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. KSIF Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

[FLARE CONNECTION TYPE] ATTENTION

Installation Manual Forest Series All Model Numbers

AIR CONDITIONER FLOOR CEILING

Installation manual. Split Type Room Air Conditioner

FDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed)

SPLIT-TYPE ROOM AIR CONDITIONER

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

INSTALLATION INSTRUCTIONS

DAIKIN AIR CONDITIONER

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI

Installation Instructions

Notices for installation

Ductless S plit Air Conditioner

HEAT PUMP INSTALLATION MANUAL

Installation Instructions

INSTALLATION MANUAL. R22 Split Series. Models FTY25GXV1 FTY35GXV1. Installation manual R22 Split series

Split Air Conditioner

SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO )

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF

DLCMRA. INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

Installation Instructions

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Saunier Duval Clima, S.A.

Safety Precautions (1)

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

Installation Instructions

Installation Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Reverse Cycle Inverter Split System Air Conditioner

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

FLEX MULTI SPLIT DUAL ZONE & TRI-ZONE INSTALLATION INSTRUCTIONS

1. BEFORE INSTALLATION

Nortek Global HVAC, LLC

Installation Manual. Oasis Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Mini-Split Air Conditioner

AS09HPAN AS12HPAN. Split-type Air Conditioner (Cooling and Heating)

Split-type Air-Conditioner

Split-type Air-Conditioner

UltraV Series Outdoor Units

Installation Instructions

Installation Instructions

Installation Instructions

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Installation Manual Super-Slim Four-Way Cassette

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

1. BEFORE INSTALLATION

Transcription:

SPLIT WALL-MOUNTED AIR CONDITIONER MODELS: WS 090C / WS 090H / WS00H EMAILAIR I N S T A L L A T I O N I N S T R U C T I O N S

ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2 LOCATION OF INDOOR AND OUTDOOR UNITS Shape Name Qty Used for Select the location considering the following: INDOOR UNIT Mounting rail Wall mounting of indoor unit. Choose a location which will provide good air circulation. Ensure that no objects or furnishings prevent air circulation. 2. Do not install the unit near a heat source or where it will be exposed to direct sunlight. Remote control with batteries Operation of unit 3. The location must allow convenient electrical drainage and tubing connections. 4. Installation site should provide an easy passage to outdoors. Remote control bracket Wall mounting of remote control 5.The unit must be mounted on a strong wall that will withstand vibrationgenerated noise. 6. Install the mounting plate as shown. Screws Washers Dowels Screws, Dowels 4 2 Wall mounting of indoor unit Wall mounting of the remote control bracket OUTDOOR UNIT.The location must allow easy servicing and provide good air circulation. 2. The unit may be suspended from a wall by a bracket (optional) or located in a free standing position on the floor (preferably slightly elevated). 3. Before the unit is suspended, ensure that the bracket is firmly connected and the wall is strong enough to withstand vibrations.. Outdoor unit drain connector Outdoor unit water drain 4.Unit location should not disturb neighbors with noise or exhaust air stream. 5. Place the mounting pads under the unit legs. Mounting pads 4 Padding of outdoor unit bottom supports 6. Install the outdoor unit as shown. Refer to the technical and service manual for allowed distances. 7. When the unit is installed on a wall, install the drain connector hose as shown. Cable ties 4 Securing wires in the indoor and outdoor unit Cable terminals Securing of grounding wire on the indoor and outdoor unit Fig.. Bottom of outdoor unit 2. Drain connector Fig. 2 Drain installation example Operation instructions Users' reference Installation instructions and template Installers' reference Air purifying filter (Optional) 2 Cleaning the air Fig Fig 2

Fig. 3. To attach 2. To remove Fig 4 Fig 3 Fig. 4. Mounting pads (x4)

3 ELECTRICAL REQUIREMENTS Electrical wiring and connections should be made by qualified electricians and in accordance with local electrical codes and regulations. The air conditioner units must be grounded. The air conditioner unit must be connected to an adequate power outlet from a separate branch circuit protected by a time delay circuit breaker, as specified on unit's nameplate. Voltage should not vary beyond ±0% of the rated voltage. 4 INSTALLATION OF THE INDOOR UNIT INSTALLATION OF THE FRONT INDOOR UNIT Removal of the right cover. Remove screw caps (2) from cover (). 2. Remove the three screws (3). 3. Rotate the right cover to remove it. Removal of the bottom cover. Remove screw caps (5) from the air outlet. 2. Loosen the screws (6) of the air outlet. 3. Pull the cover (4) down and then to the right to disengage it. REFRIGERATION TUBE ROUTING. There are four possible routes for installing the refrigeration tube as shown. 2. For routes (2) or (4), cut the side notches in the left or right panel. Fig 6 Fig.6. Righthand rear outlet 2. Lefthand outlet 3. Lefthand rear outlet 4. Righthand outlet Fig.5. Right cover 2. Screw caps 3. Screw 4. Bottom cover 5. Screw caps 6. Screws INSTALLATION OF THE MOUNTING RAIL. Figure 7 shows the location of the mounting rail relative to the unit size. 2. Locate the mounting plate as shown on the wall in a horizontal position, using a spirit level. 3. Mark the position of the four mounting holes on the wall and drill holes to accommodate the dowels. 4. Mount the mounting rail on to the wall by the screws. Ensure screws are tightened properly. 5. Mount the unit on the mounting rail. Fig.7. Indoor unit. 2. Mounting rail. Fig 5 Fig 7

PENETRATION OF WALL FOR TUBING. Mark the location of the hole on either side, according to tubing routings, as shown. and drill it at a 5 downward angle, as shown. 2. The hole is drilled at an angle to prevent condensed or rain water from penetrating back into the room. 3.Trim the hole in the wall with a ø70 mm commercial plastic tube. Fig 8 Fig. 8 A. Outdoor side B. Indoor side. Drill Ø70 mm 2. Wall 5 CONDENSATE HOSE CONNECTION. Attach the condensate drain hose to the corrugated hose in the rear groove of the indoor unit. 2. Wrap the drain hose together with the refrigerant tubes and electrical cables. 3. Ensure that the condensate drain hose is installed at all points in a downward slope manner. Fig. 9. Drain hose 2. Clamp 3. Downward slope Fig 9 4. When installing the drain hose avoid traps and U-bends. The end of the drain hose should not be immersed in water. Fig. 0. Trap 2. U-bend 3. End immersed in water Fig 0 5. For a lefthand outlet, lay the drain hose on the bottom of the indoor unit rear groove. Fig.. Electric cable 2. Refrigerant tubing 3. Condensate drain hose Fig 6. When the installation location requires long horizontal sections, a vent must be provided at the top of the hose to prevent overflow of the unit drain pan. Fig. 2. Vent 2. Downword drain 3. Water drain hose Fig 2 7. Upon completing the installation, test the water drain by pouring at least two liters of water into the unit drainpan. Check that the water drains off.

6 ELECTRICAL CONNECTIONS BETWEEN INDOOR AND OUTDOOR UNITS. To connect the indoor unit with the outdoor unit use the following electrical cables, protected for outdoor use: Fig. 3. Terminals 2. Cover 3. Cable tie SINGLE PHASE MODELS (see Fig. 4a) Coolingand heatingmodel: Multi wire cable : 5 wires x 2.5 mm² Twin wire cable: 2 wires x 0.5 mm² - For low voltage. Coolingonly model: Multi wire cable : 4 wires x 2.5 mm². Twin wire cable: 2 wires x 0.5 mm² - For low voltage. For units above 0 KW (see Fig.4b) The main power supply (5) will be connected to the outdoor unit. THREE PHASE MODELS (see Fig. 4c) The main power supply electrical cable must be of H05VV-K5G type and contain 5 x2.5 mm² conductors, connected to a thermally protected circuit breaker 3 x 2.5A. Fig. 3 NOTES:. The wire color codes can be selected by the installer. 2. Wires leading to terminals 8 and 9 must be in a separate twin wire cable, otherwise the electronic controls will be subject to operational malfunctions. 3. For cooling only model. Wire (5) should not be connected to terminal No. 5. 4. In some models the twin wire cable is factory-connected to the indoor unit. 2. Prepare inter-unit cable ends for connections. 3. Connect the cable ends to the terminals of the indoor and outdoor unit, as shown in Fig. 4a, Fig. 4b and Fig. 4c. Be sure to match the colored wires with the numbers shown on the indoor and outdoor unit terminal boards. 4. Connect the yellow/green ground wire to the ground terminal screw. 5. Secure multiple wire power cable with the cable clamps. 6. Fasten the twin wire cable to the power cable with cable ties. Fig. 4a Fig. 4b Fig. 4a/4b/4c. Outdoor unit 2. Terminal board 3. Control cable 4. Indoor unit 5. Power supply 6. Electrical interconnecting cable 7. Terminal board male/female Fig. 4c

7 REFRIGERANT TUBING CONNECT THE INDOOR TO THE OUTDOOR UNIT The indoor unit contains a small quantity of Helium. Do not unscrew the nuts from the unit until you are ready to connect the tubing. The outdoor unit is supplied with sufficient refrigerant charge for a 6 m tubing length. For additional charge, please refer to outdoor unit nameplate. To prevent crushing, bend tubes using a bending tool. NOTE: Use refrigeration type copper tubing only.. Use tubing diameter that corresponds to the tubing diameter of the indoor and outdoor units. Note that the liquid and suction tubes have different diameters. (See tube size, torque tightening table.) 2.Place flare nuts on tube ends before preparing them with a flaring tool. Use the flare nuts that are mounted on the supplied outdoor and indoor units. 3. Connect the four ends of the tubing to the indoor and outdoor units. 4. Insulate each tube separately, and their unions, with at least 6 mm of insulation. Wrap the refrigerant tubing, drain hose and electric cables together with a vinyl tape (UV protected). Caution! When unscrewing the valve caps, do not stand in front of them or the spindles at any time, as the system is under pressure. Tightening torques of unions and valve caps: Fig. 6. Wrench 2. Torque wrench 3. Union TUBE SIZE Liquid line 3/8" Suction line /2" Suction line 5/8" Suction line 3/4" Fig. 7 To prevent refrigerant leakage, coat the flared surface with refrigeration oil TORQUE 30-35 N.M. 50-54 N.M. 75-78 N.M. 80-00 N.M. Fig 6 Fig 7 Fig 8 Fig. 8. Suction valve 2. Service port 3.Liquid valve EVACUATION OF THE REFRIGERATION TUBES AND THE INDOOR UNIT After connecting the unions of the indoor and outdoor units, purge the air from the tubes and indoor unit as follows:. Connect the charging hoses with a push pin to the low and high sides of the charging set and the service port of the suction and liquid valves. Be sure to connect the end of the charging hose with the push pin to the service port. 2. Connect the center hose of the charging set to a vacuum pump. 3. Turn on the power switch of the vacuum pump and make sure that the needle in the gauge moves from 0 MPa (0 cm Hg) to -0. MPa (-76 cm Hg). Let the pump run for fifteen minutes. 4. Close the valves of both the low and high sides of the charging set and turn off the vacuum pump. Note that the needle in the gauge should not move after approximately five minutes. 5. Disconnect the charging hose from the vacuum pump and from the service ports of the suction and liquid valves. 6. Tighten the service port caps of both suction and liquid valves. 7. Remove the valve caps from both valves, and open them using a hexagonal Allen wrench. 8. Remount valve caps onto both of the valves. 9. Check for gas leaks from the four unions and from the valve caps. Test with electronic leak detector or with a sponge immersed in soapy water for bubbles. Fig 5 Fig. 5. INDOOR UNIT 2. Liquid tube (small dia.) 3. Suction tube (large dia.) 4. Plugs 5. Flare nuts 6. Tubing insulation 7. Suction tube 8. Liquid tube 9. OUTDOOR UNIT 0. Flare nuts. Suction valve (larger) 2. Liquid valve (small) Fig 9 Fig. 9. Charging set 2. Vacuum pump 3. OUTDOOR UNIT 4. Service valve NOTE: For additional R-22 charge of various tubing lengths, refer to outdoor unit nameplate. 5. Cap 6. Suction valve 7. Service valve* 8. Cap 9. Liquid valve 0. INDOOR UNIT. Suction flare connection 2. Liquid flare connection * In some models only

8 FINAL TASKS. Replace all valve caps and ensure that they are tightened properly. 2. Fill gaps on the wall between hole sides and tubing with sealer. 3. Attach wiring and tubing to the wall with clamps where necessary. 4. Operate the air conditioner together with the customer and explain all functions. 5. Explain filter removal, cleaning and installation. 6. Give the operating and installation manuals to the customer.

HEAD OFFICE 745 Springvale Road Mulgrave, Victoria 370 Tel: (03) 927 3505 Fax: (03) 927 355 VICTORIA MULGRAVE 745 Springvale Road Mulgrave, Victoria 370 Tel: (03) 927 3534 Fax: (03) 927 3540 NEW SOUTH WALES SILVERWATER 46-48 Derby Street Silverwater, NSW 228 Tel: (02) 9202 0444 Fax: (02) 9202 0488 QUEENSLAND ARCHERFIELD 4 Parkview Drive Archerfield, Qld. 408 Tel: (07) 3274 477 Fax: (07) 3274 452 TOWNSVILLE -5 Everett Street PO Box 49 Bohle Townsville, Qld. 488 Tel: (07) 4774 6552 Fax: (07) 4774 4967 WESTERN AUSTRALIA OSBORNE PARK 9 Howe Street Osborne Park, WA 607 Tel: (08) 9244 5699 Fax: (08) 9244 5437 SOUTH AUSTRALIA/NORTHERN TERRITORY ADELAIDE Suite 27, 8 Greenhill Road Wayville, SA 5034 Tel: (08) 8372 7866 Fax: (08) 8372 786 ECP (AUSTRALIA) PTY LTD ACN 082 755 655 WMN RC2 / CAT. NO. 439533 / ENGLISH / REV.05 02/2000