Revise the metric values throughout the standard to follow the soft conversions provided by the metric task group

Similar documents
Public Comment No. 16-NFPA 13D-2014 [ Section No ]

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

Committee Input No. 28-NFPA 13R-2013 [ Global Input ]

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements

Second Revision No. 2-NFPA [ Section No ]

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

freedom residential flush pendent sprinkler vk476 (K4.9)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

1 of /3/ :03 PM. Public Input No. 1-NFPA 13D-2015 [ Chapter 2 ]

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

WORKING DRAFT OF COMMITTEE MEETING OUTPUT

Second Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA

standard/quick response extended coverage light and ordinary hazard elo sprinklers

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Public Comment No. 20-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

Public Comment No. 2-NFPA [ Section No ]

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

First Revision No. 6-NFPA [ Section No. 2.2 ]

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE

RESIDENTIAL SPRINKLER INSTALLATION GUIDE


NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ]

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

SENJU SPRINKLER CO., LTD.

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

Second Revision No. 3-NFPA [ Section No. 2.3 ]

26 of 128 9/23/2014 9:25 AM

MONTECITO FIRE PROTECTION DISTRICT

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

Fire Prevention Coffee Break Training. May 2017

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

mirage standard response concealed pendent sprinkler vk492 (K5.6)

SAF-BCF SECOND REVISIONS WITH STATEMENTS

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

freedom residential Upright sprinkler vk467 (k4.9)

TECHNICAL DATA OBSOLETE


TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

TECHNICAL DATA OBSOLETE

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

MSC Guidelines for Automatic Sprinkler Systems

The distances in shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking garages.

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

freedom residential concealed pendent lead free sprinkler

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

Committee Input No. 60-NFPA [ Sections , ]

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

freedom residential concealed pendent Sprinkler vk458 (K7.4)


TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

Data Sheet 4.24 Issue F

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421

microfast sr/qr extended coverage pendent sprinkler

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

freedom residential concealed pendent sprinkler VK488 (K3.0)

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

MODEL V-BB SPECIFIC APPLICATION TECHNICAL DATA

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Location of Requirements Listed Category I appliances Type B gas vent 12.7 Listed appliances equipped with. Chimney Single wall metal pipe 12.

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

Transcription:

of 36 9/22/2014 9:37 AM Second Revision No. 14-NFPA 13D-2014 [ Global Comment ] Revise the metric values throughout the standard to follow the soft conversions provided by the metric task group Supplemental Information File Name 13_Metrification_-_AUT-RSS.xlsx Description metric conversions Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Jun 20 12:12:59 EDT 2014 Committee Statement Committee Statement: Response Message: The conversions proposed for the 2016 edition will be based on a soft conversion scheme as opposed to the traditional hard conversion. The attached spreadsheet provides the proposed conversion.

Piping Equivalents Conversion Factors (T.1.6.1.3) English (in.) Metric (mm) SI Unit Eng. Unit Factor 1/4 6 L gal 1 gal = 3.785 L 3/8 10 mm/min gpm/ft2 1 gpm/ft2 = 40.746 mm/min 1/2 15 dm3 gal 1 gal = 3.785 dm3 3/4 20 Pa psi 1 psi = 6894.757 Pa 1 25 bar psi 1 psi = 0.0689 bar 1 1/4 32 Pa --> bar - 1 bar = 1E5 Pa 1 1/2 40 1 3/4 45 Length 2 50 SI Unit Eng. Unit Factor 2 1/2 65 m ft 1 ft = 0.3048 m 3 80 m in 1 in = 0.0254 m 3 1/2 mm in 1 in = 25.4 mm 4 100 5 125 Area, Volume 6 150 SI Unit Eng. Unit Factor 8 200 m2 ft2 1 ft2 = 0.0929 m2 10 250 m2 in2 1 in2 = 0.0006452 m2 12 300 mm2 in2 1 in2 = 645.15 mm2 14 350 m3 ft3 1 ft3 = 0.02832 m3 16 400 mm3 in3 1 in3 = 16387 mm3 18 450 20 500 Other 24 600 SI Unit Eng. Unit Factor kj/kg Btu/lb 1 Btu/lb = 2.326 kj/kg g oz. 1 oz = 28.35 g kj/m2 Btu/ft2 1 Btu/ft2 = 11.356 kj/m2

of 36 9/22/2014 9:37 AM Second Revision No. 1-NFPA 13D-2014 [ Section No. 2.3.3 ] 2.3.3 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM A 53 ASTM A53/A53M, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless, 2010 2012. ASTM A 135 ASTM A135/A135M, Standard Specification for Electric-Resistance-Welded Steel Pipe, 2009 (2004). ASTM A 234 ASTM A234/A234M, Standard Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Moderate and High Temperature Service, 2010 2013 e1. ASTM A 795 ASTM A795/A795M, Standard Specification for Black and Hot-Dipped Zinc-Coated (Galvanized) Welded and Seamless Steel Pipe for Fire Protection Use, 2008 2013. ASTM B 32 ASTM B32, Standard Specification for Solder Metal, 2008. ASTM B 43 ASTM B43, Standard Specification for Seamless Red Brass Pipe, 2009. ASTM B 75 ASTM B75 /B75M, Standard Specification for Seamless Copper Tube, 2002 2011. ASTM B 88 ASTM B88, Standard Specification for Seamless Copper Water Tube, 2009. ASTM B 251 ASTM B251, Standard Specification for General Requirements for Wrought Seamless Copper and Copper-Alloy Tube, 2010. ASTM B 813 ASTM B813, Standard Specification for Liquid and Paste Fluxes for Soldering Applications of Copper and Copper-Alloy Tube, 2010 (2010). ASTM B 828 ASTM B828, Standard Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings, 2002. ASTM F 437 ASTM F437, Standard Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80, 2009. ASTM F 438 ASTM F438, Standard Specification for Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40, 2009. ASTM F 439 ASTM F439, Standard Specification for Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80, 2009 2013. ASTM F 442 ASTM F442/F442M, Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR), 2009 2013 e1. ASTM F 876 ASTM F876, Standard Specification for linked Polyethylene (PEX) Tubing, 2011 2013 e1. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 13:34:11 EDT 2014 Committee Statement Committee Statement: standards date updates

of 36 9/22/2014 9:37 AM Response Message: Public Comment No. 16-NFPA 13D-2014 [Section No. 2.3.3] Public Comment No. 29-NFPA 13D-2014 [Section No. 2.3.3]

of 36 9/22/2014 9:37 AM Second Revision No. 13-NFPA 13D-2014 [ Section No. 4.5 ] 4.5* Documentation. Documentation shall be available provided upon request to ensure adequate demonstrate that the water supply, listed devices, and adequate sprinkler coverage have been addressed comply with the requirements of this standard. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 16:54:30 EDT 2014 Committee Statement Committee Statement: Response Message: The word adequate is difficult to enforce. The revised language makes the section more enforceable.

Second Revision No. 2-NFPA 13D-2014 [ Section No. 5.1.1.1 ] 5.1.1.1* Where a sprinkler is removed from a fitting or welded outlet, it shall not be reinstalled except as permitted by 5.1.1.1.1. 5.1.1.1.1 Dry sprinklers shall be permitted to be reinstalled, where they are not removed by applying torque at the point where the sprinkler is attached to the barrel when removed in accordance with the manufacturer s installation and maintenance instructions. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 14:06:11 EDT 2014 Committee Statement Committee Statement: The first draft language eliminates the possibility of removing dry sprinklers with a head wrench even if the manufacturer recommends it. At least one manufacturer recommends installing and removing their dry sprinklers with a head wrench. The wording has been modified to allow the use of a head wrench if the manufacturer recommends it. Response Message: Public Comment No. 26-NFPA 13D-2014 [Section No. 5.1.1.1] Public Comment No. 27-NFPA 13D-2014 [Section No. A.5.1.1.1.1] of 36 9/22/2014 9:37 AM

of 36 9/22/2014 9:37 AM Second Revision No. 4-NFPA 13D-2014 [ Section No. 5.1.2.1 ] 5.1.2.1 Tanks, expansion tanks, gauges, pumps, hangers, waterflow detection devices, and valves shall not be required to be listed. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 14:24:08 EDT 2014 Committee Statement Committee Statement: Response Message: Gauges are not always required but when they are utilized, should not be required to be listed. Public Comment No. 10-NFPA 13D-2014 [Section No. 5.1.2.1]

of 36 9/22/2014 9:37 AM Second Revision No. 6-NFPA 13D-2014 [ New Section after 8.2.5.6 ] 8.2.5.7 Small areas created by architectural features, such as planter box windows, bay windows, and similar features, shall be evaluated as follows: (1) Where no additional floor area is created by the architectural feature, no additional sprinkler protection is required. (2) Where additional floor area is created by an architectural feature, no additional sprinkler protection is required, provided all of the following conditions are met: (a) (b) (c) (d) The floor area shall not exceed 18 ft 2 (1.7 m 2 ). The floor area shall not be greater than 2 ft (0.61 m) in depth at the deepest point of the architectural feature to the plane of the primary wall where measured along the finished floor. The floor shall not be greater than 9 ft (2.7 m) in length where measured along the plane of the primary wall. Measurement from the deepest point of the architectural feature to the sprinkler shall not exceed the maximum listed spacing of the sprinkler. (3) The hydraulic design shall not be required to consider the area created by the architectural feature. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 15:13:12 EDT 2014 Committee Statement Committee Statement: This language has long been in the annex of NFPA 13D and it is clear that additional floor area created by certain architectural features are not required to have additional sprinkler coverage. As this language is in the annex and not in the enforceable body of the standard, this intent is not consistently applied to such architectural features. Moving this language to the body of the standard will make it clear that additional sprinkler protection is not required in these small areas. As these areas are not required to be included in the hydraulic design area of the systems, these areas are distinct from shadow areas Response Message: Public Comment No. 32-NFPA 13D-2014 [New Section after 8.2.5.6]

Second Revision No. 5-NFPA 13D-2014 [ Section No. 8.2.7 ] 8.2.7 Closets. In all closets and compartments, including those housing mechanical equipment, that are smaller than 400 ft 3 (11.3 m 3 ), a single sprinkler at the highest ceiling space shall be sufficient without regard to obstructions or minimum distances to wall. pendent, upright, and sidewall residential sprinklers shall be permitted to be installed in either of the following situations: (1) Within 18 in. (460 mm) of the ceiling to avoid obstructions near the ceiling (2) at At the highest ceiling space shall be sufficient level without regard to obstructions or minimum distances to wall Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 15:03:32 EDT 2014 Committee Statement Committee Statement: Small closets, especially those housing mechanical equipment, frequently contain obstructions that make it difficult to place sprinklers within 12 inches of the ceiling. Allowing residential sprinklers to be located further down would allow adequate sprinkler protection of these small closets while avoiding ceiling level obstructions such as ducts and pipes. Based upon CFAST Computer Fire Model, an analysis was performed comparing the performance of sprinklers located 6 inches down from a ceiling in a small room to the performance of sprinklers 18 inches down from the ceiling in an even smaller closet. Based upon this analysis it appears that residential sprinklers 18 inches down from the ceiling in a closet up to 400 ft3 react to a fire at least as quickly as residential sprinklers 6 inches down from a ceiling in a small room. Using equivalency concepts, residential sprinklers could be allowed to be installed within 18 inches of the ceiling in small closets. Response Message: Public Comment No. 11-NFPA 13D-2014 [Section No. 8.2.7] Public Comment No. 25-NFPA 13D-2014 [New Section after 8.2.7] of 36 9/22/2014 9:37 AM

of 36 9/22/2014 9:37 AM Second Revision No. 8-NFPA 13D-2014 [ Section No. 8.3.3 ] 8.3.3 Sprinklers shall not be required in clothes closets, linen closets, and pantries that meet all of the following conditions: (1) The area of the space does not exceed 24 ft 2 (2.2 2.1 m 2 ). (2) The walls and ceilings are surfaced with noncombustible or limited-combustible materials as defined in NFPA 220. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 16:10:13 EDT 2014 Committee Statement Committee Statement: Editorial. Delete the (3) Response Message: Public Comment No. 12-NFPA 13D-2014 [Section No. 8.3.3]

0 of 36 9/22/2014 9:37 AM Second Revision No. 9-NFPA 13D-2014 [ Section No. 10.4.3 ]

1 of 36 9/22/2014 9:37 AM 10.4.3

2 of 36 9/22/2014 9:37 AM Unless the pipe size is in accordance with the prescriptive pipe sizing method of 10.4.9, pipe shall be sized by hydraulic calculations in accordance with the methods described in NFPA 13, with the manufacturer's listed installation instructions, with 10.4.4, or with the following general method for straight-run systems connected to a city water main of at least 4 in. (102 mm) in diameter: The pipes shall be sized using one of the following techniques: (1) The simplified calculation method of 10.4.4, which can only be used for connections to a city water main of at least 4 in. (100 mm) in diameter (2) The prescritive pipe sizing method of 10.4.9 (3) The hydraulic calculation procedure for NFPA 13 (4) The manufacturer s listed installation instructions The system flow rate shall be established in accordance with Sections 10.1 and 10.2, and it shall be determined that the flow allowed by the water meter meets or exceeds the system demand and that the total demand flow does not exceed the maximum flow allowed by the piping system components. The water pressure in the street shall be determined. Pipe sizes shall be selected. * Pressure loss for a water meter, if any, shall be determined and deducted using one of the following: Table 10.4.3(a) shall be permitted to be used, even where the sprinkler demand flow exceeds the meter's rated continuous flow. Higher pressure losses specified by the manufacturer shall be used in place of those specified in Table 10.4.3(a). Lower pressure losses shall be permitted to be used where supporting data are provided by the meter manufacturer. Pressure loss for elevation shall be deducted as follows: Building height above street (ft) 0.433 = pressure loss (psi) Building height above street (m) 0.098 = pressure loss (bar) * Pressure losses from the city main to the inside control valve shall be deducted by multiplying the pressure loss associated with the pipe material by the total length(s) of pipe in feet (meters). Pressure loss for piping within the building shall be deducted by multiplying the pressure loss associated with the pipe material by the total length(s) of pipe in feet (meters). Pressure loss for valves and fittings shall be deducted as follows: The valves and fittings from the control valve to the farthest sprinkler shall be counted. The equivalent length for each valve and fitting as shown in Table 10.4.3(b), Table 10.4.3(c), or Table 10.4.3(d) or Table 10.4.3(e) shall be determined and the values added to obtain the total equivalent length for each pipe size. The equivalent length for each size shall be multiplied by the pressure loss associated with the pipe material and the values totaled. In multilevel buildings, the steps in 10.4.3 (1) through 10.4.3 (8) shall be repeated to size piping for each floor. If the remaining pressure is less than the operating pressure established by the testing laboratory for the sprinkler being used, the sprinkler system shall be redesigned. If the remaining pressure is higher than required, smaller piping shall be permitted to be used where justified by calculations.

3 of 36 9/22/2014 9:37 AM The remaining piping shall be sized the same as the piping up to and including the farthest sprinkler unless smaller pipe sizes are justified by calculations. Table 10.4.3(a) Pressure Losses in psi in Water Meters Meter Size (in.) Flow (gpm) 18 or less 23 26 31 39 52 5 8 9 14 18 26 38 * 3 4 7 11 14 22 35 * 1 2 3 3 4 6 10 1 1 2 1 1 2 2 4 7 2 1 1 1 1 2 3 For SI units, 1 gpm = 3.785 L/min; 1 in. = 25.4 mm; 1 psi = 0.0689 bar. *Above maximum rated flow of commonly available meters. Table 10.4.3(b) Equivalent Length in Feet of Fittings and s for Schedule 40 Steel Pipe Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Pattern Cock 1 1 2 2 5 2 0 12 28 15 4 5 1 1 4 1 3 2 6 2 0 15 35 18 5 7 1 1 2 2 4 2 8 3 0 18 43 22 6 9 2 2 5 3 10 3 1 24 57 28 7 11 For SI units, 1 in. = 25.4 mm; 1 ft = 0.3048 m. Table 10.4.3(c) Equivalent Length in Feet of Fittings and s for Type K Copper Tube Diameter (in.) 45 Radius turned degrees) straight through) Gate Angle Y Pattern Cock 3 4 0 1 0 3 1 0 7 14 7 2 0 1 1 2 2 6 2 0 14 33 18 5 6 1 1 4 1 3 2 5 2 0 14 32 16 5 6 1 1 2 2 4 2 8 3 0 18 43 22 6 9 2 2 6 3 12 4 1 28 66 33 8 13 For SI units, 1 in. = 25.4 mm; 1 ft = 0.3048 m. Table 10.4.3(d) Equivalent Length in Feet of Fittings and s for Type L Copper Tube Diameter (in.) 45 Long- Long- Radius turned degrees) straight through) Gate Angle Y Pattern Cock 3 4 0 2 0 4 1 0 8 18 10 3 0 1 1 3 3 7 2 0 16 38 20 5 7 1 1 4 1 3 2 6 2 0 15 35 18 5 7 Check Check Check

4 of 36 9/22/2014 9:37 AM Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Pattern Cock 1 1 2 2 4 2 9 3 0 20 47 24 7 10 2 2 6 4 12 4 1 30 71 35 9 14 For SI units, 1 in. = 25.4 mm; 1 ft = 0.3048 m. Table 10.4.3(e) Equivalent Length in Feet of Fittings and s for Type M Copper Tube Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Pattern Cock 3 4 0 2 0 4 1 0 10 21 11 3 0 1 2 3 3 8 3 0 19 43 23 6 8 1 1 4 1 3 2 7 2 0 16 38 20 5 8 1 1 2 2 5 2 9 3 0 21 50 26 7 11 2 3 7 4 13 5 1 32 75 37 9 14 For SI units, 1 in. = 25.4 mm; 1 ft = 0.3048 m. Check Check Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 16:11:08 EDT 2014 Committee Statement Committee Statement: Section 10.4.3, as written is confusing and not "user friendly". This revision seeks to simplify and clarify the acceptable methods for sizing sprinkler pipes for NFPA 13D systems. This comment's does not change the existing requirements of this section, but instead changes the requirements from paragraph form to a list form for ease of interpretation. The 12 step general method originally included in section 10.4.3 has been retained but renumbered as section 10.4.4. Response Message: Public Comment No. 23-NFPA 13D-2014 [Section No. 10.4.3]

5 of 36 9/22/2014 9:37 AM Second Revision No. 15-NFPA 13D-2014 [ Section No. 10.4.4 ]

6 of 36 9/22/2014 9:37 AM 10.4.4* General Pipe Sizing Method.

7 of 36 9/22/2014 9:37 AM Smaller pipe sizes than those determined by 10.4.3 shall be permitted where justified by calculations for systems connected to city water mains of at least 4 in. (102 mm) in diameter. The following is the general pipe sizing method for straight-run systems connected to a city water main of at least 4 in. (100 mm) in diameter in accordance with 10.4.3(1) : (1) The system flow rate shall be established in accordance with Sections 10.1 and 10.2, and it shall be determined that the flow allowed by the water meter meets or exceeds the system demand and that the total demand flow does not exceed the maximum flow allowed by the piping system components. (2) The water pressure in the street shall be determined. (3) Pipe sizes shall be selected. (4) * Pressure loss for a water meter, if any, shall be determined and deducted using one of the following: (a) (b) (c) Table 10.4.4(a) Table 10.4.4(a)Table 10.4.3(a) shall be permitted to be used, even where the sprinkler demand flow exceeds the meter's rated continuous flow. Higher pressure losses specified by the manufacturer shall be used in place of those specified in Table 10.4.4(a) Table 10.4.4(a)Table 10.4.3(a). Lower pressure losses shall be permitted to be used where supporting data are provided by the meter manufacturer. (5) Pressure loss for elevation shall be deducted as follows: (a) (b) Building height above street (ft) 0.433 = pressure loss (psi) Building height above street (m) 0.098 = pressure loss (bar) (6) * Pressure losses from the city main to the inside control valve shall be deducted by multiplying the pressure loss associated with the pipe material by the total length(s) of pipe in feet (meters). (7) Pressure loss for piping within the building shall be deducted by multiplying the pressure loss associated with the pipe material by the total length(s) of pipe in feet (meters). (8) Pressure loss for valves and fittings shall be deducted as follows: (a) (b) (c) The valves and fittings from the control valve to the farthest sprinkler shall be counted. The equivalent length for each valve and fitting as shown in Table 10.4.4(b) Table 10.4.4(b)Table 10.4.3(b), Table 10.4.4(c) Table 10.4.4(c)Table 10.4.3(c), or Table 10.4.4(d) Table 10.4.4(d)Table 10.4.3(d) or Table 10.4.4(e) Table 10.4.4(e)Table 10.4.3(e) shall be determined and the values added to obtain the total equivalent length for each pipe size. The equivalent length for each size shall be multiplied by the pressure loss associated with the pipe material and the values totaled. (9) In multilevel buildings, the steps in 10.4.4(1) 10.4.4(1)10.4.3 through 10.4.4(8) 10.4.4(8)10.4.3 shall be repeated to size piping for each floor. (10) If the remaining pressure is less than the operating pressure established by the testing laboratory for the sprinkler being used, the sprinkler system shall be redesigned. (11) If the remaining pressure is higher than required, smaller piping shall be permitted to be used where justified by calculations. (12) The remaining piping shall be sized the same as the piping up to and including the farthest sprinkler unless smaller pipe sizes are justified by calculations. Table 10.4.4(a) Pressure Losses in psi in Water Meters Meter Size Flow (gpm) (in.) 18 or less 23 26 31 39 52 5 8 9 14 18 26 38 * 3 4 7 11 14 22 35 * 1 2 3 3 4 6 10 1 1 2 1 1 2 2 4 7

8 of 36 9/22/2014 9:37 AM Meter Size (in.) Flow (gpm) 18 or less 23 26 31 39 52 2 1 1 1 1 2 3 For SI units, 1 gpm = 3.785 L/min; 1 in. = 25.4 25 mm; 1 psi = 0.0689 bar. *Above maximum rated flow of commonly available meters. Table 10.4.4(b) Equivalent Length in Feet of Fittings and s for Schedule 40 Steel Pipe Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Pattern Cock 1 1 2 2 5 2 0 12 28 15 4 5 1 1 4 1 3 2 6 2 0 15 35 18 5 7 1 1 2 2 4 2 8 3 0 18 43 22 6 9 2 2 5 3 10 3 1 24 57 28 7 11 For SI units, 1 in. = 25.4 25 mm; 1 ft = 0.3048 m. Table 10.4.4(c) Equivalent Length in Feet of Fittings and s for Type K Copper Tube Diameter (in.) 45 turned degrees) straight through) Gate Angle Y Pattern Cock 3 4 0 1 0 3 1 0 7 14 7 2 0 1 1 2 2 6 2 0 14 33 18 5 6 1 1 4 1 3 2 5 2 0 14 32 16 5 6 1 1 2 2 4 2 8 3 0 18 43 22 6 9 2 2 6 3 12 4 1 28 66 33 8 13 For SI units, 1 in. = 25.4 25 mm; 1 ft = 0.3048 m. Table 10.4.4(d) Equivalent Length in Feet of Fittings and s for Type L Copper Tube Diameter (in.) 45 Long- Radius Long- Radius turned degrees) straight through) Gate Angle Y Pattern Cock 3 4 0 2 0 4 1 0 8 18 10 3 0 1 1 3 3 7 2 0 16 38 20 5 7 1 1 4 1 3 2 6 2 0 15 35 18 5 7 1 1 2 2 4 2 9 3 0 20 47 24 7 10 2 2 6 4 12 4 1 30 71 35 9 14 For SI units, 1 in. = 25.4 25 mm; 1 ft = 0.3048 m. Table 10.4.4(e) Equivalent Length in Feet of Fittings and s for Type M Copper Tube Check Check Check Diameter (in.) 45 Long- Radius Gate Angle Y Pattern Cock Check

9 of 36 9/22/2014 9:37 AM turned degrees) straight through) 3 4 0 2 0 4 1 0 10 21 11 3 0 1 2 3 3 8 3 0 19 43 23 6 8 1 1 4 1 3 2 7 2 0 16 38 20 5 8 1 1 2 2 5 2 9 3 0 21 50 26 7 11 2 3 7 4 13 5 1 32 75 37 9 14 For SI units, 1 in. = 25.4 25 mm; 1 ft = 0.3048 m. Supplemental Information File Name SR-15_Tables.docx Description Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Fri Jun 20 12:17:20 EDT 2014 Committee Statement Committee Statement: Response Message: The general method of pipe sizing has been moved from section 10.4.3 to 10.4.4 to correlate with SR-9. The wording and method itself remains unchanged. Public Comment No. 19-NFPA 13D-2014 [Section No. 10.4.4]

Table 10.4.4(a) Pressure Losses in psi in Water Meters Meter Size Flow (gpm) (in.) 18 or less 23 26 31 39 52 ⅝ 9 14 18 26 38 * ¾ 7 11 14 22 35 * 1 2 3 3 4 6 10 1½ 1 1 2 2 4 7 2 1 1 1 1 2 3 For SI units, 1 gpm = 3.785 L/min; 1 in. = 25.4 mm; 1 psi = 0.0689 bar. *Above maximum rated flow of commonly available meters. Table 10.4.4(b) Equivalent Length in Feet of Fittings and s for Schedule 40 Steel Pipe Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Cock Check Pattern 1 1 2 2 5 2 0 12 28 15 4 5 1 ¼ 1 3 2 6 2 0 15 35 18 5 7 1 ½ 2 4 2 8 3 0 18 43 22 6 9 2 2 5 3 10 3 1 24 57 28 7 11 For SI units, 1 in. = 25.4 mm; 1 ft = 0.3048 m.

Table 10.4.4(c) Equivalent Length in Feet of Fittings and s for Type K Copper Tube Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Cock Check Pattern ¾ 0 1 0 3 1 0 7 14 7 2 0 1 1 2 2 6 2 0 14 33 18 5 6 1 ¼ 1 3 2 5 2 0 14 32 16 5 6 1 ½ 2 4 2 8 3 0 18 43 22 6 9 2 2 6 3 12 4 1 28 66 33 8 13 For SI units, 1 in. = 25.4 mm; 1 ft = 0.3048 m. Table 10.4.4(d) Equivalent Length in Feet of Fittings and s for Type L Copper Tube Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Cock Check Pattern ¾ 0 2 0 4 1 0 8 18 10 3 0 1 1 3 3 7 2 0 16 38 20 5 7 1 ¼ 1 3 2 6 2 0 15 35 18 5 7 1 ½ 2 4 2 9 3 0 20 47 24 7 10 2 2 6 4 12 4 1 30 71 35 9 14 For SI units, 1 in. = 25.4 mm; 1 ft = 0.3048 m.

Table 10.4.4(e) Equivalent Length in Feet of Fittings and s for Type M Copper Tube Diameter (in.) 45 Long- Radius turned degrees) straight through) Gate Angle Y Cock Check Pattern ¾ 0 2 0 4 1 0 10 21 11 3 0 1 2 3 3 8 3 0 19 43 23 6 8 1 ¼ 1 3 2 7 2 0 16 38 20 5 8 1 ½ 2 5 2 9 3 0 21 50 26 7 11 2 3 7 4 13 5 1 32 75 37 9 14 For SI units, 1 in. = 25.4 mm; 1 ft = 0.3048 m.

Second Revision No. 10-NFPA 13D-2014 [ Section No. 12.3.2 ] 12.3.2 Any sprinkler that is operated, damaged, corroded, covered with foreign materials, or showing signs of leakage shall be replaced with a new listed sprinkler having the same performance characteristics as the original equipment. 12.3.2.1* Where replacing residential sprinklers manufactured prior to 2003 and that are no longer available from the manufacturer and are installed using a design density less than 0.05 gpm/ft 2 (204 mm/min), a residential sprinkler with an equivalent K-factor (± 5%) shall be permitted to be used provided the currently listed coverage area for the replacement sprinkler is not exceeded. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 16:20:10 EDT 2014 Committee Statement Committee Statement: It is preferred to replace existing sprinklers with the same model when it is available so that the systems continue to operate as it was designed. Response Message: Public Comment No. 13-NFPA 13D-2014 [Section No. 12.3.2.1] Public Comment No. 17-NFPA 13D-2014 [Section No. 12.3.2.1] Public Comment No. 24-NFPA 13D-2014 [Section No. 12.3.2] Public Comment No. 30-NFPA 13D-2014 [Section No. 12.3.2.1] 0 of 36 9/22/2014 9:37 AM

1 of 36 9/22/2014 9:37 AM Second Revision No. 3-NFPA 13D-2014 [ Section No. A.5.1.1.1.1 ] A.5.1.1.1.1 Provided dry sprinklers are removed by utilizing a pipe wrench on the barrel, where permitted by the manufacturer, they can be reinstalled. If a dry sprinkler is removed by utilizing the sprinkler wrench on the boss of the sprinkler, the dry sprinkler should not be reinstalled. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 14:16:13 EDT 2014 Committee Statement Committee Statement: Response Message: This annex section is no longer warranted due to the change to 5.1.1.1.1 which addresses the allowance to reinstall dry sprinklers that were removed in accordance with the manufacturers maintenance and installation requirements.

2 of 36 9/22/2014 9:37 AM Second Revision No. 12-NFPA 13D-2014 [ Section No. A.6.2 ]

3 of 36 9/22/2014 9:37 AM A.6.2

4 of 36 9/22/2014 9:37 AM The connection to city mains for fire protection is often subject to local regulation of metering and backflow prevention requirements. Preferred and acceptable water supply arrangements are shown in Figure A.6.2(a)through Figure A.6.2(d). Where it is necessary to use a meter between the city water main and the sprinkler system supply, an acceptable arrangement as shown in Figure A.6.2(c)and Figure A.6.2(d)can be used. Under these circumstances, the flow characteristics of the meter are to be included in the hydraulic calculation of the system [see Table 10.4.4(a)]. Where a tank is used for both domestic and fire protection purposes, a low water alarm that actuates when the water level falls below 110 percent of the minimum quantity specified in 6.1.2 should be provided. The effect of pressure-reducing valves on the system should be considered in the hydraulic calculation procedures. Figure A.6.2(a), Figure A.6.2(c), or Figure A.6.2(d)are acceptable methods for getting the water supply into the unit for a stand-alone sprinkler system (one that does not also provide direct connections to the cold water fixtures) because the common supply pipe for the domestic system and the sprinkler system between the water supply and the dwelling unit has a single control valve that shuts the sprinkler system, which helps to ensure that people who have running water to their domestic fixtures also have fire protection. This serves as a form of supervision for the control valve and can be used to make sure that the valve stays open in place of other, more expensive options such as tamper switches with a monitoring service. Some water utilities insist on separate taps and supply pipes from the water supply to the dwelling unit for fire sprinkler systems as shown in Figure A.6.2(d), due to concerns about shutting off the water supply for nonpayment of bills and the desire not to shut off fire protection if this ever occurs. While these types of arrangements are acceptable, they might not be cost efficient and should be discouraged due to the extra cost burden this places on the building owner. The concern over shutting off the water for nonpayment of bills is a nonissue for a number of reasons. First, the water utilities rarely actually shut off water for nonpayment. Second, if they do shut off water for nonpayment, they are creating violations of all sorts of health and safety codes, allowing people to live in a home without running water. Concern over the fire protection for those individuals when they are violating all kinds of other health codes is disingenuous. More likely, the water utility will not shut off the water and will follow other legal avenues to collect on unpaid bills, such as liens on property. Millions of people should not have to pay hundreds of millions of dollars to install separate water taps and lines for the few services that might get shut off. Figure A.6.2(a) Minimum Requirements for a Stand-Alone System. Figure A.6.2(b) Acceptable Arrangement for Stand-Alone Piping Systems Option 1.

5 of 36 9/22/2014 9:37 AM Figure A.6.2(c) Acceptable Arrangement for Stand-Alone Piping System Option 2.

6 of 36 9/22/2014 9:37 AM Figure A.6.2(d) Acceptable Arrangement for Stand-alone Piping Systems Option 3. Supplemental Information File Name NFPA_13D_F.A.6.2_b_.pdf NFPA_13D_F.A.6.2_c_and_d_.pdf G13D-6r2.jpg G13D-7r2.jpg G13D-55r1.jpg Description Fig A.6.2(b) Fig A.6.2(c) and (d) Fig A.6.2(b)-rev Fig A.6.2(c)-rev Fig A.6.2(d)-rev

7 of 36 9/22/2014 9:37 AM Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 16:46:22 EDT 2014 Committee Statement Committee Statement: Response Message: Figures A.6.2(b), (c), and (d) have been revised to more accurately reflect the recommended location for the system gauges.

8 of 36 9/22/2014 9:37 AM Second Revision No. 7-NFPA 13D-2014 [ Section No. A.8.2.5 ] Global SR-14

9 of 36 9/22/2014 9:37 AM A.8.2.5

0 of 36 9/22/2014 9:37 AM The objective is to position sprinklers so that the response time and discharge are not unduly affected by obstructions such as ceiling slope, beams, light fixtures, or ceiling fans. The rules in this section, while different from the obstruction rules of NFPA 13, provide a reasonable level of life safety while maintaining the philosophy of keeping NFPA 13D relatively simple to apply and enforce. Fire testing has indicated the need to wet walls in the area protected by residential sprinklers at a level closer to the ceiling than that accomplished by standard sprinkler distribution. Where beams, light fixtures, sloped ceilings, and other obstructions occur, additional residential sprinklers are necessary to achieve proper response and distribution. In addition, for sloped ceilings, higher flow rates could be needed. Guidance should be obtained from the manufacturer. A series of 33 full-scale tests were conducted in a test room with a floor area of 12 ft 24 ft ( 3.6 3.7 m 7.2 m) to determine the effect of cathedral (sloped) and beamed ceiling construction, and combinations of both, on fast-response residential sprinkler performance. The testing was performed using one pendent-type residential sprinkler model, two ceiling slopes (0 degrees and 14 degrees), and two beam configurations on a single enclosure size. In order to judge the effectiveness of sprinklers in controlling fires, two baseline tests, in which the ceiling was smooth and horizontal, were conducted with the pendent sprinklers installed and with a total water supply of 26 gpm ( 98 100 L/min) as required by this standard. The results of the baseline tests were compared with tests in which the ceiling was beamed or sloped, or both, and two pendent sprinklers were installed with the same water supply. Under the limited conditions used for testing, the comparison indicates that sloped or beamed ceilings, or a combination of both, represent a serious challenge to the fire protection afforded by fast-response residential sprinklers. However, further tests with beamed ceilings indicated that fire control equivalent to that obtained in the baseline tests can be obtained where one sprinkler is centered in each bay formed by the beams and a total water supply of 36 gpm ( 136 135 L/min) is available. Fire control equivalent to that obtained in the baseline tests was obtained for the smooth, sloped ceiling tests where three sprinklers were installed with a total water supply of 54 gpm ( 200 205 L/min). In a single smoldering-started fire test, the fire was suppressed. Small areas created by architectural features such as planter box windows, bay windows, and similar features can be evaluated as follows: Where no additional floor area is created by the architectural feature, no additional sprinkler protection is required. Where additional floor area is created by an architectural feature, no additional sprinkler protection is required, provided all of the following conditions are met: The floor area does not exceed 18 ft 2 (1.7 m 2 ). The floor area is not greater than 2 ft (0.65 m) in depth at the deepest point of the architectural feature to the plane of the primary wall where measured along the finished floor. The floor area is not greater than 9 ft (2.9 m) in length where measured along the plane of the primary wall. Measurement from the deepest point of the architectural feature to the sprinkler should not exceed the maximum listed spacing of the sprinkler. The hydraulic design is not required to consider the area created by the architectural feature. Where the obstruction criteria established by this standard are followed, sprinkler spray patterns will not necessarily get water to every square foot of space within a room. As such, a sprinkler in a room with acceptable obstructions as outlined in this standard might not be capable of passing the fire test (specified by ANSI/UL 1626, Residential Sprinklers for Fire-Protection Service, and other similar laboratory standards) if the fire is started in one of these dry areas. This occurrence is not to be interpreted as a failure of the sprinkler. The laboratory fire tests are sufficiently challenging to the sprinkler without additional obstructions as a safety factor to account for the variables that actually occur in dwellings, including acceptable obstructions to spray patterns. The rules on 8.2.5.1 and 8.2.5.2 were developed from a testing series conducted by the National Fire Sprinkler Association and The Viking Corporation that included fire modeling, sprinkler response tests, sprinkler distribution tests, and full-scale fire tests (Valentine and Isman, Interaction of Residential Sprinklers, Ceiling Fans and Similar Obstructions, National Fire Sprinkler Association, November 2005 ). This test series, along with additional industry experience, shows that a difference exists between obstructions that are tight to the ceiling and obstructions that hang down from the ceiling, allowing spray over the top. Residential sprinklers require high wall wetting, which means that they tend to spray over

1 of 36 9/22/2014 9:37 AM obstructions that hang down from the ceiling. The test series showed that the fan blades were not significant obstructions and that as long as the sprinkler was far enough from the fan motor housing (measured from the center of the housing), the sprinkler could control a fire on the other side of the fan in a small room. In larger rooms, the sprinkler will need to be augmented by additional sprinklers on the other side of the fan. The test series showed that the fan on low or medium speed did not make a significant difference in sprinkler performance. On high speed (pushing air down), the fan did impact sprinkler performance, but fire control was still achieved in small rooms. In larger rooms, it is expected that additional sprinklers would be installed. The test series also showed that the fan blowing down was more significant than the fan pulling air up. The rules in 8.2.5.6 were developed from years of experience with obstruction rules and an additional test series conducted by the National Fire Sprinkler Association with the help of Tyco International (Valentine and Isman, Kitchen Cabinets and Residential Sprinklers, National Fire Sprinkler Association, November 2005 ), which included fire modeling, distribution tests, and full-scale fire tests. The test series showed that pendent sprinklers definitely provide protection for kitchens, even for fires that start under the cabinets. The information in the series was less than definitive for sidewall sprinklers, but distribution data show that sprinklers in the positions in this standard provide adequate water distribution in front of the cabinets and that sidewall sprinklers should be able to control a fire that starts under the cabinets. When protecting kitchens or similar rooms with cabinets, the pendent sprinkler should be the first option. If pendent sprinklers cannot be installed, the next best option is a sidewall sprinkler on the opposite wall from the cabinets, spraying in the direction of the cabinets. The third best option is the sidewall sprinkler on the same wall as the cabinets on a soffit flush with the face of the cabinet. The last option should be putting sprinklers on the wall back behind the face of the cabinet because this location is subject to being blocked by items placed on top of the cabinets. It is not the intent of the committee to require sprinklers to be installed under kitchen cabinets. Submitter Information Verification Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 15:15:43 EDT 2014 Committee Statement Committee Statement: Response Message: The annex language being deleted from this section is being moved to a new section in 8.2.5.7. Public Comment No. 4-NFPA 13D-2014 [Section No. A.8.2.5] Public Comment No. 31-NFPA 13D-2014 [Section No. A.8.2.5]

2 of 36 9/22/2014 9:37 AM Second Revision No. 11-NFPA 13D-2014 [ Section No. A.10.4.3 ]

3 of 36 9/22/2014 9:37 AM A.10.4.4

4 of 36 9/22/2014 9:37 AM The determination of public water supply pressure should take into account the probable minimum pressure conditions prevailing during such periods as during the night or during the summer months when heavy usage can occur. The possibility of interruption by floods or ice conditions in winter also should be considered. [See Figure A.10.4.4(a), Figure A.10.4.4(b), Table A.10.4.4(a), Table A.10.4.4(b), Table A.10.4.4(c), and Table A.10.4.4(d).] Figure A.10.4.4(a) Calculation Sheet. Figure A.10.4.4(b) Calculation Sheet Elevated Tank, Booster Pump, Pump Tank Supply. Table A.10.4.4(a) Pressure Losses in psi/ft for Schedule 40 Steel Pipe (C = 120) Pipe Size (in.) Flow Rate (gpm)

5 of 36 9/22/2014 9:37 AM 10 12 14 16 18 20 25 30 35 40 45 50 1 0.04 0.05 0.07 0.09 0.11 0.13 0.20 0.28 0.37 0.47 0.58 0.71 1 1 4 0.01 0.01 0.02 0.02 0.03 0.03 0.05 0.07 0.10 0.12 0.15 0.19 1 1 2 0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.03 0.05 0.06 0.07 0.09 2 0.01 0.01 0.01 0.01 0.02 0.02 0.03 For SI units, 1 gal = 3.785 L; 1 psi = 0.0689 bar; 1 in. = 25.4 mm; 1 ft = 0.3048 m. Table A.10.4.4(b) Pressure Losses in psi/ft for Copper Tubing Types K, L, and M (C = 150) Flow Rate (gpm) Tubing Size (in.) Type 10 12 14 16 18 20 25 30 35 40 45 50 3 4 M 0.08 0.12 0.16 0.20 0.25 0.30 0.46 0.64 0.85 L 0.10 0.14 0.18 0.23 0.29 0.35 0.53 0.75 1.00 K 0.13 0.18 0.24 0.30 0.38 0.46 0.69 0.97 1.28 1 M 0.02 0.03 0.04 0.06 0.07 0.08 0.13 0.18 0.24 0.30 0.38 0.46 L 0.03 0.04 0.05 0.06 0.08 0.10 0.15 0.20 0.27 0.35 0.43 0.53 K 0.03 0.04 0.06 0.07 0.09 0.11 0.17 0.24 0.31 0.40 0.50 0.61 1 1 4 M 0.01 0.01 0.02 0.02 0.03 0.03 0.05 0.07 0.09 0.11 0.15 0.17 L 0.01 0.01 0.02 0.02 0.03 0.03 0.05 0.07 0.10 0.12 0.16 0.19 K 0.01 0.01 0.02 0.02 0.03 0.04 0.06 0.08 0.11 0.13 0.17 0.20 1 1 2 M 0.01 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.05 0.06 0.08 L 0.01 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.05 0.07 0.08 K 0.01 0.01 0.01 0.01 0.02 0.02 0.03 0.05 0.06 0.07 0.09 2 M 0.01 0.01 0.01 0.01 0.02 0.02 L 0.01 0.01 0.01 0.01 0.02 0.02 K 0.01 0.01 0.01 0.01 0.02 0.02 For SI units, 1 gal = 3.785 L; 1 psi = 0.0689 bar; 1 in. = 25.4 mm; 1 ft = 0.3048 m. Table A.10.4.4(c) Pressure Losses in psi/ft for CPVC Pipe (C = 150) Nominal Pipe Size (in.) Actual Pipe Size (in.) Flow Rate (gpm) 10 12 14 16 18 20 25 30 35 40 45 50 3 4 0.874 0.05 0.07 0.10 0.13 0.16 0.19 0.29 0.40 0.53 0.68 0.85 1.03 1 1.101 0.02 0.02 0.03 0.04 0.05 0.06 0.09 0.13 0.17 0.22 0.28 0.34 1 1 4 1.394 0.01 0.01 0.01 0.01 0.02 0.02 0.03 0.04 0.05 0.07 0.09 0.11 1 1 2 1.598 0 0 0.01 0.01 0.01 0.01 0.02 0.02 0.03 0.04 0.04 0.05 2 2.003 0 0 0 0 0 0 0.01 0.01 0.01 0.01 0.01 0.02 Table A.10.4.4(d) Pressure Losses in psi/ft for PEX Pipe (C = 150) Nominal Pipe Size (in.) Actual Pipe Size (in.) Flow Rate (gpm) 10 12 14 16 18 20 25 30 35 40 45 50 3 4 0.68 0.18 0.25 0.33 0.43 0.53 0.64 0.97 1.36 1.81 2.32 2.88 3.50 1 0.875 0.05 0.07 0.10 0.12 0.16 0.19 0.28 0.40 0.53 0.68 0.84 1.03 1 1 4 1.07 0.02 0.03 0.04 0.05 0.06 0.07 0.11 0.15 0.20 0.26 0.32 0.39 1 1 2 1.263 0.01 0.01 0.02 0.02 0.03 0.03 0.05 0.07 0.09 0.11 0.14 0.17 2 1.653 0 0 0 0.01 0.01 0.01 0.01 0.02 0.02 0.03 0.04 0.05 Submitter Information Verification

6 of 36 9/22/2014 9:37 AM Submitter Full Name: Matthew Klaus Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Jun 19 16:30:28 EDT 2014 Committee Statement Committee Statement: These Annex notes have been renumbered to correlate with public comment 19 and 20. Response Message: Public Comment No. 21-NFPA 13D-2014 [Section No. A.10.4.3]