Arrow Hart hospital grade self-test GFCI receptacles

Similar documents
Arrow Hart specification grade GFCI receptacles

Gfci Self Test Duplex 20A 125V WH

AF/GF dual-purpose receptacles

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

Specification Grade Straight Blade Receptacles. Quality solutions that provide reliable connectivity in all applications

Tamper & Weather Resistant Receptacles

Residential Occupancy & Vacancy Sensors

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

AHAC-DT MicroSet dual tech low/line voltage ceiling sensors

Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Aspire LED, CFL & Incandescent Dimmer

Toggle AL series dimmer

Toggle AL series dimmer

Slide AL series dimmer

Smart AL series dimmers

Smart AL series dimmers

SAL06PBK 300/600W 120V Dimmer. Features. Dimensions and Weight. Long Description

Decorator AL series dimmer

MORE PROTECTION. MORE FUNCTIONALITY. IN MORE ENVIRONMENTS.

Aspire smart AL dimmer

3099-2E. Technical Information

Receptacles. Wiring Devices Receptacles. Receptacle Families. Receptacle Colors. Standard Grade. Academy Series Outlets. Decorator Standard Grade

Recp Duplex 20A 125V 2P3W STR Swire WH

AUTOGUARD Hubbell Self Test Ground Fault Circuit Interrupters. More innovation. More protection. More safety.

Recp HG Dup 20A 125V 2P3W STR B/Swire WH

Wallbox Lighting Controls Project Name:

The Safer Living Collection

TAMPER & WEATHER RESISTANT RECEPTACLES

Installation Instructions

SECTION (16140) - WIRING DEVICES

Extra Heavy Duty Industrial & Hospital Grade GFCI Receptacles

Introducing Hermaphroditic Blade and Receptacle Connector

PART GENERAL 1.01 SECTION INCLUDES

2014 NEC for. Understanding the. AFCI protection AFCI code compliant safety. Eaton is a registered trademark.

GE Industrial Solutions. Residential Electronic Circuit Interrupters

The most complete line of proven safety solutions.

0ACDT2000MV Ultasonic/Infared Occ Sensor

Lighting and Fan Speed Controls

CIRCUITPRO Self Test Ground Fault Receptacles

Switch Toggle DP 20A 120/277V Swire Iv

Marathon Special Products

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

Installation and Operation Manual

ASCO Series 185 Power Transfer Switches

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Gen Purpose Wiring Devices - Gen Purpose Switches

AH8219HG Conn HG 15A 125V 2P3W STR BW

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

Sure-Lites. 13" [330mm] 3 1/8" [80mm] 4 3/4" [121mm] Emergency Light w/remote Capacity SEL SERIES

T6984F,G Electronic Floating Control Thermostats

A. This Section provides requirements and specifications for wiring devices, wiring device accessories, and wiring device assemblies including:

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

DTA. Motor thermistor relay. Benefits. Description

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

RZI06, RZE06, RZI10, RZM10

SIMPLEX WEATHERPROOF CONTROL PANELS

Project. Comments. Prepared by. - EZ Hang feature facilitates fast - Prorated 5-year battery warranty - Overload / Short Circuit - NEC/OSHA

IllumaTech Innovations

White Paper: Installation Guidelines for Receptacles on Small Appliance Branch Circuits in the City of Chicago

CAUTION READ CAREFULLY

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

Wallbox Lighting Controls Project Name:

Arc-Fault Circuit Interrupters (AFCIs) Frequently Asked Questions

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Power Blocks - Splicer/Distribution

4SNLEDLD548SLUNV 4snledld548slunvl840cd1u

Remote Alarm Panels Features

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS

Ground Breaking Innovation

SPECIFICATION SUBMITTAL

Introducing SlimSeal SSL Connector

We ve Got Panels Under Control.

Across-the-Line SERIES MP300 Combined Manual and Automatic

WH231/WR231. General Features. Operational Information. Discharge 11 gpm at 40 psig (0.69 lps at 28 m) 7.8 gpm at 80 psig (0.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

XP Series Non-Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

SAFETY INFORMATION AND WARNINGS

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

Communications Point Data Base for Communications Protocol IEC

TS 910/TS 920 AUTOMATIC TRANSFER SWITCHES OWNERS MANUAL

Soft Start Series MP700 Solid State, Reduced Voltage

OPTOTRONIC Power Supply OT96W/24V/UNV/DIM

Quality. Trust. Value. Safety.

Effective May 2017 Supersedes October 1998 (S )

Attention-grabbing performance from two new stacklights

GFCI Products Buying Guide

Two Circuit Heavy Duty Burner Connector

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

EDS Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

CHAPTER 20 SERVICE EQUIPMENT

Job No A. Submit the following equipment, materials and products, including all fittings and accessories:

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS

Transcription:

Description 2-pole, 3-wire grounding 15A, 125V/AC; 20A, 125V/AC NEMA 5-15, 5-20 Design features Performs periodic self-tests to ensure integrity of GFCI protection. Meets and exceeds 10 ka short circuit testing and Underwriters Laboratories (UL) UL943 safety standards Visual trip indicator light gives quick notification of a tripped or end of life condition Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used SGFH15 Ground termination with back wire clamp provides secure wiring and reduces installation time Tamper resistant shutters help prevent foreign objects from being inserted Line side terminals are backed out and staked for fast installation Horizontal test/reset button alignment provides larger unobstructed area Test and reset buttons are color matched to provide superior aesthetics TRSGFH20 Tapered back wire openings handle multiple wire sizes and types for applications up to #10 AWG solid or stranded wire When downstream receptacles are wired from load side, a 20A feed-through rating offers full protection Line-load miswiring protection: GFCIs will not provide power downstream when wired incorrectly Tri-combo head terminal and mounting screws Hospital grade models UL Listed, fully compliant with all latest UL943 Class A GFCI and UL498 hospital grade requirements Tamper resistant models comply with 2017 NEC Article 406.12 for all dwelling units Lock-out functionality prevents miswired line-load connections and GFCI circuitry damage Each device carries a 20A feed-through rating Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations Matching standard size thermoplastic wallplate included

Table 1. Hospital grade self-test GFCIs Rating Catalog no. Description A V/AC NEMA Color suffix SGFH15 Hospital GFCI, 15 125 5-15R B, GY, LA, SGFH15F Hospital GFCI, 15 125 5-15R B, GY, LA, SGFH20 Hospital GFCI, 20 125 5-20R B, GY, LA, SGFH20F Hospital GFCI, 20 125 5-20R B, GY, LA, Table 2. Hospital grade self-test tamper resistant GFCIs Rating Catalog no. Description A V/AC NEMA Color suffix TRSGFH15 Tamper resistant hospital GFCI, 15 125 5-15R B, GY, LA, TRSGFH15F Tamper resistant hospital GFCI, TRSGFH20 Tamper resistant hospital GFCI, TRSGFH20F Tamper resistant hospital GFCI, 15 125 5-15R B, GY, LA, 20 125 5-20R B, GY, LA, 20 125 5-20R B, GY, LA, Table 3. GFCI status indicator Test indicator RED LED Test indicator AMBER LED Diagnosis Action OFF OFF Device is functioning properly OR branch circuit may have no power Manually depress TEST button to trip device. Amber light should come ON If Amber light does not come ON, check if there is power to the branch If Amber light does come ON, manually depress the RESET button to restore power to the device If GFCI does not reset, replace GFCI If GFCI does reset, device is functioning properly OFF ON Device is in tripped state Manually depress the RESET button to restore power to the device If GFCI does not reset, replace GFCI Blinking OFF Device s end of life indication OR device is in reset state Blinking ON Device s end of life indication OR device is in tripped state Manually depress TEST button to trip device. Amber light should come ON If Amber light does not come ON, check if there is power to the branch If Amber light does come ON, manually depress the RESET button to restore power to the device If it does not reset, and/or the blinking continues, replace GFCI Manually depress the RESET button to restore power to the device If it does not reset, and/or the blinking continues, replace GFCI Applications are designed with the safety of the user in mind. In commercial and industrial areas like public bathrooms, breakrooms and food service areas, the NEC requires. Arrow Hart self-test are UL Listed and fully compliant with all of the latest UL943 Class A GFCI and UL498 requirements. The self-test GFCIs conduct an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available. Additionally, GFCIs incorporate a safety lock-out functionality to protect against mis-wired line-load connections and GFCI circuitry damage. Table 4. Specifications Catalog no. SGFH and SGFH F series TRSGFH and TRSGFH F series Device type Hospital grade duplex GFCI 15A & 20A Hospital grade tamper resistant duplex GFCI, 15A & 20A Wiring type Back & side wire Back & side wire Testing & code compliance culus Listed to UL 498 and UL 943, file no. E60120 Meets all UL 943 (GFCI), UL 498 (receptacles), UL 498 Hospital grade and applicable CSA requirements NOM certified Environmental specifications Flammability: Meets UL 94 requirements; V2 rated Temperature rating: -35ºC to 66ºC (-31ºF to 150.8ºF) Electrical specifications Dielectric voltage: Withstands 2000V per UL 498 Current interrupting: Yes, at full-rated current Temperature rise: Max. 30ºC (86 F) after 100 cycles of overload @ 150% of rated current (DC) Trip time: 0.025 seconds (Class A) Frequency: 60 Hz; Voltage: 125V; Amperage: 15A/20A 20A feed-through Short circuit testing: Meets and exceeds 10 ka Maximum interrupting capacity: 20 Amps Mechanical specifications Terminal accommodation: #14-10 AWG Voltage ratings: Permanently marked on device culus Listed to UL 498 and UL 943, file no. E60120 Meets all UL 943 (GFCI), UL 498 (receptacles), UL 498 Hospital grade and applicable CSA requirements NOM certified Flammability: Meets UL 94 requirements; V2 rated Temperature rating: -35ºC to 66ºC (-31ºF to 150.8ºF) Dielectric voltage: Withstands 2000V per UL 498 Current interrupting: Yes, at full-rated current Temperature rise: Max. 30ºC (86 F) after 100 cycles of overload @ 150% of rated current (DC) Trip time: 0.025 seconds (Class A) Frequency: 60 Hz; Voltage: 125V; Amperage: 15A/20A 20A 20A feed-through Short circuit testing: Meets and exceeds 10 ka Maximum interrupting capacity: 20 Amps Terminal accommodation: #14-10 AWG Voltage ratings: Permanently marked on device 2 EATON www.eaton.com/arrowhart

Technical Data Table 6. Materials Catalog no. SGFH and SGFH F series TRSGFH and TRSGFH F series Top housing Thermoplastic, nylon Thermoplastic, nylon Bottom housing Polycarbonate Polycarbonate Strap 0.047 thick steel, zinc plated 0.047 thick steel, zinc plated Line contacts 0.030 thick brass 0.030 thick brass Terminal & ground screws #8-32 steel, brass plated; neutral screw nickel plated, ground screw green Terminal clamps 0.070 thick steel 0.070 thick steel #8-32 steel, brass plated; neutral screw nickel plated, ground screw green Table 5. Color ordering information For ordering devices, include Cat. no. followed by the color code: B (Brown), BK (Black), GY (Gray), LA (Light Almond), RD (Red), V (Ivory), W (White) B BK GY LA RD V W (Brown) (Black) (Gray) (Lt. Almond) (Red) (Ivory) (White) Wiring diagrams Figure 1. One cable (2 or 3 wires) entering the box Figure 2. Two cables (4 or 6 wires) entering the box EATON www.eaton.com/arrowhart 3

Product dimensions Figure 3. SGFH15 Line art with dimensions Figure 4. SGFH20 Line art with dimensions 1.68 (42.7mm) 1.30 (33mm) 1.68 (42.7mm) 1.30 (33mm) 4.20 (106.6mm) 4.20 (106.6mm) 3.28 (83.3mm) 3.28 (83.3mm) 1.26 (32mm) 1.26 (32mm) Figure 5. TRSGFH15 Line art with dimensions Figure 6. TRSGFH20 Line art with dimensions 4 EATON www.eaton.com/arrowhart

Certifications & compliances Catalog no. SGFH15 SGFH15F TRSGFH15 TRSGFH15F SGFH20 SGFH20F TRSGFH20 TRSGFH20F KEY: culus NOM Arrowlink Build-To-Spec Build-To-Spec Customizable Devices 203 Cooper Circle Peachtree City, GA 30269 United States Eaton.com Canada Operations 5925 McLaughlin Road Mississauga, Ontario, L5R 1B8 Canada EatonCanada.ca Mexico Operations Carr. Tlalnepantla - Cuautitlan Km 17.8 s/n Col. Villa Jardin esq. Cerrada 8 de Mayo Cuautitlan, Mexico CP 54800 Mexico Eaton.mx Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2018 Eaton All Rights Reserved Printed in USA Publication No. TD620023EN (REV. 1) April 2018 Eaton is a registered trademark. All other trademarks are property of their respective owners.