age 1 of 14 Test Report Report o.: AGC10737170807SS01 RODUCT DESIGATIO : Laser pointer touch pen BRAD AME : /A MODEL AME : MO8097, MO8193 CLIET : Mid Ocean Brands B.V DATE OF ISSUE : Aug.18, 2017 STADARD(S) : E 60825-1:2014 REORT VERSIO : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd. CAUTIO: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context.
Report o.: AGC10737170807SS01 age 2 of 14 TEST REORT E 60825-1 Safety of laser products art 1:Equipment classification and requirements Report reference o... : AGC10737170807SS01 Tested by (+ signature)... : Kangta Kang Review by (+ signature)... : Vicky Lv Approved by (+ signature)... : Matte He (Authorized officer) Date of issue... : Aug.18, 2017 Contents... : Total 14 pages Testing laboratory ame... : Attestation of Global Compliance (Shenzhen) Co., Ltd. Address... : 2/F., Building 2, o.1-o.4, Chaxi Sanwei Technical Industrial ark, Gushu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Testing location... : Same as above Applicant ame... : Mid Ocean Brands B.V Address... : Hermesweg 9 3771 D Barneveld The etherlands Manufacturer ame... : Address... : Test specification Standard... : E 60825-1:2014 Test procedure... : type test rocedure deviation... : /A on-standard test method... : /A Test Report Form/blank test report Test Report Form o.... : AGC60825-1A2 TTRF originator... : AGC Master TTRF... : Dated 2014-12
Report o.: AGC10737170807SS01 age 3 of 14 Test item roduct designation... : Laser pointer touch pen Brand name... : /A Model ame... : MO8097, MO8193 Rating(s)... : 4.5V (Built-in 3 pcs button cell) rotection Class of equipment... : Class 2 Test case verdicts Test case does not apply to the test object : (/A) Test item does meet the requirement... : (ass) Test item does not meet the requirement.. : F(ail) Testing Date of receipt of test item... : Aug.09, 2017 Date(s) of performance of test... : Aug.16, 2017 Attachments Attachment A... : hotos of product General remarks This report shall not be reproduced except in full without the written approval of the testing laboratory. The test results presented in this report relate only to the item tested. Clause numbers between brackets refer to clauses in IEC 60825-1 (E 60825-1). "(see remark #)" refers to a remark appended to the report. "(see Annex #)" refers to an annex appended to the report. Throughout this report a comma is used as the decimal separator. Report Revise Record Report Version Revise Time Issued Date Valid Version otes V1.0 / Aug.18, 2017 Valid Original report General product information The two models have the same laser module, just the apperance is different. Summary of testing The test part of product was classified as Class 2 product. Copy of marking plate
Report o.: AGC10737170807SS01 age 4 of 14 E 60825-1 4 EGIEERIG SECIFICATIOS 4.1 General remarks Modification 4.2 rotective housing 4.2.1 General 4.2.2 Service 4.2.3 Removable laser system 4.3 Access panels and safety interlocks 4.3.1 Access panels of protective housing roduct Class...: Accessible emission during removal of access panel...: The removal of the panel gives access to laser radiation levels designated by X in the table Accessible emissions after removal...: 4.3.2 Deliberate override mechanism 4.4 Remote interlock connector 4.5 Manual reset 4.6 Key control 4.7 Laser radiation emission warning 4.7.1 Class 3R (λ<400 nm; λ>700 nm), 3B and 4 4.7.2 Audible or visible warning 4.7.3 Operational control and laser aperture 4.7.4 Laser emission distributed through more than one output 4.8 Beam stop or attenuation 4.9 Controls 4.10 Viewing optics a) Human access to laser radiation in excess of Class 1M prevented when the shutter is opened or attenuation varied b) Opening of the shutter or variation of the attenuation prevented when exposure to laser radiation in excess of Class 1M is possible
Report o.: AGC10737170807SS01 age 5 of 14 E 60825-1 4.11 Scanning safeguard 4.12 Walk-in access a) Means provided so that any person inside the housing can prevent activation of a Class 3B or 4 laser hazard b) A warning device provides adequate warning of emission to any person within the housing c) Where walk-in access during operation is intended or reasonably foreseeable, emission of laser radiation that is equivalent to Class 3B or Class 4 while someone is present inside the enclosure of Class 1, Class 2 or Class 3R product shall be prevented by engineering means 4.13 Environmental conditions - climatic conditions - vibration and shock 4.14 rotection against other hazards 4.14.1 on-optical hazards (product safety standard) - electrical hazards; - excessive temperature; - spread of fire from the equipment; - sound and ultrasonic; - harmful substances; - explosion; 4.14.2 Collateral radiation 5 LABELLIG 5.1 General LASER RODUCT CLASS...: Class 2 Labelling location (roduct / User instruction / ackage) Warning label Hazard symbol (Figure 1) Explanatory label (Figure 2) 5.2-5.6 Text on explanatory label...: See copy of marking plate 5.7 Aperture label 5.8 Radiation output and standards information
Report o.: AGC10737170807SS01 age 6 of 14 E 60825-1 Max output of laser radiation...: ulse duration...: -- Emitted wavelength...: The name and publication date of the standard...: 5.9 Labels for access panels 5.9.1 a) f) Warning wording used...: 5.9.2 Labels for safety interlocked panels Warning wording used...: 5.10 Warning for invisible laser radiation...: 5.11 Warning for visible laser radiation...: 6 OTHER IFORMATIOAL REQUIREMETS 6.1 Information for the user a) adequate instructions for proper assembly, maintenance and safe use and description of the classification limitations, if appropriate b) warning for Class 1M and 2M c) laser beam parameters for radiation above the AEL of Class 1 Wavelength...: 655nm Beam divergence...: 50 ulse duration...: Maximum power or energy output...: 0.496mW d) embedded laser products and other incorporated laser products e) ME and OHD for Class 3B and Class 4 laser products For collimated beam Class 1M and 2M lasers the extended OHD (EOHD) f) information for the selection of eye protection g) reproduction of labels h) location of laser apertures i) listing of controls, adjustment of procedures and warning statement j) information about laser energy source if not incorporated in the manual
Report o.: AGC10737170807SS01 age 7 of 14 E 60825-1 6.2 urchasing and service information a) safety classification of each laser product stated in descriptive material b) adequate instructions for servicing available 7 ADDITIOAL REQUIREMETS FOR SECIFIC LASER RODUCTS 7.1 Applicable other parts of the standard series IEC/E 60825 IEC 60825-2 (Safety of optical communication systems) IEC 60825-4 (Laser guards) IEC 60825-12 (Safety of free space optical communication systems used for transmission of information) Further information may be found in: IEC/TR 60825-3 (Guidance for laser displays and shows) IEC/TR 60825-5 (Manufacturer s checklist for IEC 60825-1) IEC/TR 60825-8 (Guidelines for the safe use of laser beams on humans) IEC/TR 60825-9 (Compilation of maximum permissible exposure to incoherent optical radiation) IEC/TR 60825-10 (Application guidelines and explanatory notes to IEC 60825-1) IEC/TR 60825-13 (Measurements for classification of laser products) IEC/TR 60825-14 (A user s guide) IEC 62471 (CIE S 009) (hotobiological safety of lamps and lamp system) 7.2 Medical laser products Class 3B and Class 4 medical laser products comply with IEC 60601-2-22 7.3 Laser processing machines Comply with IEC/ISO 11553-1 7.4 Electric toys Comply with IEC 62115 7.5 Consumer electronic products
Report o.: AGC10737170807SS01 age 8 of 14 E 60825-1 Complying with IEC 60950 or IEC 60065 8 CLASSIFICATIO 8.2 Classification responsibilities 8.3 Classification rules 8.3a Radiation of a single wavelength 8.3b Radiation of multiple wavelengths 1) Laser product emission two or more wavelengths in spectral regions shown as additive in Table 5... : 2) Laser product emission two or more wavelengths in spectral regions not shown as additive in Table 5... : 8.3c Radiation from extended sources...: 1.5mrad (assumed) Value of angular subtense (mrad)... : min. 8.3d on-uniform retinal image radiance profile, noncircular and multiple sources 8.3e Time basis 1) 0.25s 2) 100s 3) 30000s 8.3f Repetitively pulsed or modulated lasers 1) Exposure from any single pulse not exceeding the AEL for a single pulse 2) Average power for a pulse train 3a) Constant pulse energy and pulse duration 3b) Varying pulse widths or varying pulse durations 9 DETERMIATIO OF ACCESSIBLE EMISSIO LEVELS 9.1 Tests Single fault eliminated Housing material withstanding degradation Fault detection 9.2 Measurement conditions... : a, b, c, d, e, f, h
Report o.: AGC10737170807SS01 age 9 of 14 E 60825-1 Measured laser radiation... : See table measured laser radiation, calculations and comparison with AEL limits 9.3 Measurement geometry 9.3.1 General, evaluation scheme a) Simplified (default) method b) Increased AEL by parameter C 6 9.3.2 Default (simplified) evaluation Condition applied... : Condition 2 Aperture stop diameter (mm)... : 7mm Measurement distance (mm)... : 70mm 9.3.3 Extended sources C 6... : C 6=1 9.3.3a Aperture diameters Condition applied... : Aperture stop diameter (mm).... : Angular subtense of the apparent source... : 9.3.3b Angle of acceptance Condition applied... : 1) hotochemical retinal limits... : Angel of acceptance... : 2) All other retinal limits... : Angel of acceptance... :
Report o.: AGC10737170807SS01 age 10 of 14 E 60825-1 9.3 TABLE: Calculation of Accessible emission limit (AEL) Class 2 Time base t: 0.25s Wavelength λ : 655.0nm Beam shape Angular Subtense α: 1,5mrad osition of app. source: Distance r (Rth): 70mm Distance r (hc): Aperture d (Rth): 7mm Aperture d (hc): Angle of acc. γp (Rth): Angle of acc. γ p (hc): Breakpoint T1: ulse width t pw: Breakpoint T2: eriod duration: C1: umber of pulses : C2: C 5: C3: C 6: 1 C4: C 7: AEL limits: = 1mW ote(s): -- 9.3 TABLE: Radiant power under normal and fault condition Ambient temperature: 25 C Ambient radiation: 0.397µW compensated with zero function of power meter Measurement condition: Condition 2 according to standard. Measurement Input current Measured radiant power ormal condition* -- 0.496 mw Fault condition : Resistor short circuit -- 0.002 mw ote(s): *: Under normal operation, the output light shape of the product as a line. Conclusion: The measured emission level of the product did not exceed the accessible emission level of Class 2; the test subject was classified as Class 2 Laser product. Appended table EQUIMET MAUFACTURE IFORMATIO ( DATA SHEET ) ABOUT THE COTAIIG LASER COMOET/S Manufacturer... : Symbol technologies Inc.
Report o.: AGC10737170807SS01 age 11 of 14 E 60825-1 Type designation... : -- Structure... : -- Wavelength... : 655nm Output power (min. and max.)... : -- Radiation is Continuous... : Yes ulsed... : o ulse time... : o ulse repetition frequency... : o Others... : o IC U UIT Manufacturer... : Type designation... : Others... : TRASMITTER/TRASCIEVER UIT Manufacturer... : Type designation... : Others... :
Report o.: AGC10737170807SS01 age 12 of 14 Attachment A hotos of product Fig.1 Overall view Fig.2 art view
Report o.: AGC10737170807SS01 age 13 of 14 Fig.3 art view Fig.4 art view
Report o.: AGC10737170807SS01 age 14 of 14 Fig.5 art view ---End of Report---