IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Similar documents
Caledonian Flame Retardant Coaxial Cables

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Caledonian fire Resistant signal & Data cables

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Caledonian Fire resistant Coaxial Cables

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

FIRE RESISTANT CABLES

Multi-Core Fire Resistant Cable

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

PRODUCT CATALOGUE Norröna

High Performance LSZH Fire Resistant Cable

Photovoltaic Cables EN H1Z2Z2-K

CATEGORY 6A FTP RJ45 SOLUTION

BS /1000V XLPE Insulation LSZH Sheath Cables

Compact Module. Category 6A FTP Cabling System 1.1

Caledonian. FIREFLIX ire Resistant Coaxial Cables

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

Catalogue Telecommunication Cables INTRODUCCIÓN

Firecel Safety Cables

SPECIAL ELECTRICAL AND OPTICAL CABLES

Introduction.

Telecommunication Cables

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

SAS Security and Alarm Safety Cables

Cable technology for highest safety requirements

Traction Cable Radox 3 GKW

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Catalogue. Instrumentation & Control Cables

Shipboard & Offshore Cables

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

The Quality Connection. BETAflam Fire Resistant Safety Cables

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

fire resistant cables

Catalogue Power Cables

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Rolling Stock Cables.

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

CABLES FOR ALARM AND SAFETY SYSTEMS

Total Fire Solutions. Includes BS 8519 and the updated BS :

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

OIL & GAS INDUSTRY OTHER INDUSTRIES

FIRE PERFORMANCE CABLE

Comtran Cable. Hub-LINK Cables for Transit Applications

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Single core cables with reduced wall thickness

Havells Fire Survival Cables

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

UV RESISTANT ACCORDING TO HD 605 RULE

ENHANCED FIRE PERFORMANCE CABLE

INTERNATIONAL STANDARD

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

INTERNATIONAL STANDARD

FIRE RESISTANT CABLES FP200 GOLD

S Low loss coax cables with foamed PE

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

DNVGL-CP-0402 Edition February 2016

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

STANDARDS INSTALLATION. Certificate No 077m

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

DNVGL-CP-0399 Edition March 2016

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

FIRE RESISTANT CABLES FP400

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

DNVGL-CP-0401 Edition February 2016

TYPE APPROVAL CERTIFICATE

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Tratos Railway Cables

LSOH Flexible Cables

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Fire Resistant Cables

Evolution of Cable Fire Safety Standards in Australia

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Transcription:

ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire APPLICATION Cat5E is a cable standard for Gigabit Ethernet and other network protocol, suitable for basic voice and data installations up to 100. In addition, these cables can be offered with copper wire braid armoured & flame retardant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable. STANDARDS Basic design to EN50173 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* Smoke Emission IEC 61034-1&2; EN 61034-1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* No Toxic gases NES 02-713; NF C 20-454 Note: Asterisk * denotes superseded standard. 102 Caledonian

Caledonian Flame Retardant Data Cables www.caledonian-cables.co.uk www.addison-cables.com VOLTAGE RATING CABLE CONSTRUCTION Conductors: 24AWG solid bare copper. Insulation: HDPE. Twinning: Two coloured insulated conductors twisted together to form a pair. Outer : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.) Cat5E F/UTP: These cables have collective shielding of aluminium/polyester tape with drain wire. Cat5E SF/UTP: These cables have double collective shieldings of aluminium/polyester tape & copper wire braid. Physical AND THERMAL PROPERTIES Temperature range: -30 C ~ +75 C bending radius during installation (mobile state): 8 x Overall bending radius during operation (fixed state): 4 x Overall Electrical Properties AWG 24 Conductor mm 0.53 Maximum DC Resistant@20 C Ω/100m 9.38 Maximum DCR Unbalance % 5 Maximum Mutual Capacitance pf/m 55.8 Maximum Capacitance Unbalance pf/100m 330 Characteristic Impedance@1-100 Ω 100+/-15 Maximum Propagation Delay Skew ns/100m 45 Transmission Properties Maximum Attenuation NEXT PSNEXT ELFEXT PSELFEXT RL /100m /100m /100m 0.772 1.8 67.0 64.0 66.0 63.0 1 2.0 65.3 62.3 63.8 60.8 20.0 4 4.1 56.3 53.3 51.7 48.7 23.0 8 5.8 51.8 48.8 45.7 42.7 24.5 10 6.5 50.3 47.3 43.8 40.8 25.0 16 8.2 47.3 44.3 39.7 36.7 25.0 20 9.3 45.8 42.8 37.7 34.7 25.0 ADDISON 103

ADDISON Maximum Attenuation NEXT PSNEXT ELFEXT PSELFEXT RL /100m /100m /100m 25 10.4 44.3 41.3 35.8 32.8 24.3 31.25 11.7 42.9 39.9 33.9 30.9 23.6 62.5 17.0 38.4 35.4 27.8 24.8 21.5 100 22.0 35.3 32.3 23.8 20.8 20.1 CONSTRUCTION PARAMETERS Cable Code Conductor Over Insulation Pairs Screen Overall mm mm mm Cat5E U/UTP 0.5/0.51 0.91 4 Nil 5.1 Cat5E F/UTP 0.53 1.00 4 Overall Aluminum Tape Screen 6.3 Cat5E SF/UTP 0.53 1.00 4 Overall Aluminum Tape Screen & Copper Wire Braid 6.6 EN 50173 N Rated Voltage Standard Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1 NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4 Zero Low Toxicity NES 02-713/NF C 20-454 Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074 Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073 IEC60754-1 EN50267-2-1 104 Caledonian

Caledonian Flame Retardant Data Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant CAT5e CWB/SWB/SWA Armoured Data Cables FTX-CAT5e U/UTP4P24 cwb/swb/swa FTX-CAT5e f/utp4p24 cwb/swb/swa FTX-CAT5e sf/ftp4p24 cwb/swb/swa LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation LSZH Inner Tinned Copper Drain Wire Braid or Wire Armoured APPLICATION Cat5E is a cable standard for Gigabit Ethernet and other network protocol, suitable for basic voice and data installations up to 100. In addition, these cables can be offered with copper wire braid armoured & flame retardant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable. STANDARDS Basic design to EN50173 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* Smoke Emission IEC 61034-1&2; EN 61034-1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* No Toxic gases NES 02-713; NF C 20-454 Note: Asterisk * denotes superseded standard. VOLTAGE RATING ADDISON 105

ADDISON CABLE CONSTRUCTION Conductors: 24AWG solid bare copper. Insulation: HDPE. Twinning: Two coloured insulated conductors twisted together to form a pair. Inner : Flame retardant, low smoke and halogen-free polyolefin, coloured black. Armouring: cwb: copper Wire Braid swb: Steel Wire Braid swa: Steel Wire Armour Outer : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.) Cat5E F/UTP: These cables have collective shielding of aluminium/polyester tape with drain wire. Cat5E SF/UTP: These cables have double collective shieldings of aluminium/polyester tape & copper wire braid. Physical AND THERMAL PROPERTIES Temperature range: -30 C ~ +75 C bending radius during installation (mobile state): 8 x Overall bending radius during operation (fixed state): 4 x Overall Electrical Properties AWG 24 Conductor mm 0.53 Maximum DC Resistant@20 C Ω/100m 9.38 Maximum DCR Unbalance % 5 Maximum Mutual Capacitance pf/m 55.8 Maximum Capacitance Unbalance pf/100m 330 Characteristic Impedance@1-100 Ω 100+/-15 Maximum Propagation Delay Skew ns/100m 45 Transmission Properties Maximum Attenuation NEXT PSNEXT ELFEXT PSELFEXT RL /100m /100m /100m 0.772 1.8 67.0 64.0 66.0 63.0 1 2.0 65.3 62.3 63.8 60.8 20.0 4 4.1 56.3 53.3 51.7 48.7 23.0 8 5.8 51.8 48.8 45.7 42.7 24.5 10 6.5 50.3 47.3 43.8 40.8 25.0 106 Caledonian

Caledonian Flame Retardant Data Cables www.caledonian-cables.co.uk www.addison-cables.com Maximum Attenuation NEXT PSNEXT ELFEXT PSELFEXT RL /100m /100m /100m 16 8.2 47.3 44.3 39.7 36.7 25.0 20 9.3 45.8 42.8 37.7 34.7 25.0 25 10.4 44.3 41.3 35.8 32.8 24.3 31.25 11.7 42.9 39.9 33.9 30.9 23.6 62.5 17.0 38.4 35.4 27.8 24.8 21.5 100 22.0 35.3 32.3 23.8 20.8 20.1 LSZH Outer Copper Wire Braid Armoured Aluminium/Polyester Tape Solid Copper Conductor PE Insulation LSZH Inner Tinned Copper Drain Wire Braid or Wire Armoured CONSTRUCTION PARAMETERS Cat5E SF/UTP Cable Code Construction No. of elements No. of cores in element Conductor diameter Insulation Inner Outer Overall Weight mm mm mm mm mm kg/km CAT5e U/UTP CWB 4 2 0.53 0.2 0.6 1.0 7.68 97 CAT5e U/UTP SWB 4 2 0.53 0.2 0.6 1.0 7.68 93 CAT5e U/UTP SWA 4 2 0.53 0.2 0.6 1.0 8.68 165 CAT5e F/UTP CWB 4 2 0.53 0.2 0.6 1.0 8.28 116 CAT5e F/UTP SWB 4 2 0.53 0.2 0.6 1.0 8.28 112 CAT5e F/UTP SWA 4 2 0.53 0.2 0.6 1.0 9.28 192 ADDISON 107

ADDISON Cable Code Construction No. of elements No. of cores in element Conductor diameter Insulation Inner Outer Overall Weight mm mm mm mm mm kg/km CAT5e SF/UTP CWB 4 2 0.53 0.2 0.6 1.0 8.76 123 CAT5e SF/UTP SWB 4 2 0.53 0.2 0.6 1.0 8.76 119 CAT5e SF/UTP SWA 4 2 0.53 0.2 0.6 1.0 9.76 216 EN 50173 N Rated Voltage Standard Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1 NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4 Zero Low Toxicity NES 02-713/NF C 20-454 Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074 Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073 IEC60754-1 EN50267-2-1 108 Caledonian

Caledonian Flame Retardant Data Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant CAT6 Data Cables FTX-CAT6 U/UTP4P24 FTX-CAT6 F/UTP4P24 FTX-CAT6 SF/FTP4P24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire APPLICATION Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables are with copper wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable. STANDARDS Basic design to EN50173 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* Smoke Emission IEC 61034-1&2; EN 61034-1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* No Toxic gases NES 02-713; NF C 20-454 Note: Asterisk * denotes superseded standard. VOLTAGE RATING ADDISON 109

ADDISON CABLE CONSTRUCTION Conductors: 23AWG solid bare copper. Insulation: HDPE. Twinning: Two coloured insulated conductors twisted together to form a pair. Outer : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.) Cat6 F/UTP: These cables have collective shielding of aluminium/polyester tape with drain wire. Cat6 SF/UTP: These cables have double collective shieldings of aluminium/polyester tape & copper wire braid with drain wire. Physical AND THERMAL PROPERTIES Temperature range: -30 C ~ +75 C bending radius during installation (mobile state): 8 x Overall bending radius during operation (fixed state): 4 x Overall Electrical Properties AWG 23 Conductor mm 0.56/0.57 Maximum DC Resistant@20 C Ω/100m 9.38 Maximum DCR Unbalance % 3 Maximum Mutual Capacitance pf/m 5.8 Maximum Capacitance Unbalance pf/100m 30 Characteristic Impedance@1-100 Ω 100+/-15 Maximum Propagation Delay Skew ns/100m 18 Transmission Properties Maximum Attenuation /100m NEXT PSNEXT ELFEXT /100m PSELFEXT /100m 0.772 1.8 76.0 74. 70.0 67.0 1 2.0 74.3 72.3 67.8 64.8 20.0 4 3.8 65.3 63.3 55.7 52.7 23.0 8 5.3 60.8 58.8 49.7 46.7 24.5 10 6.0 59.3 57.3 47.8 44.8 25.0 16 7.6 56.3 54.3 43.7 40.7 25.0 20 8.5 54.8 52.8 41.7 38.7 25.0 25 9.5 53.3 51.3 39.8 36.8 24.3 31.25 10.7 51.9 49.9 37.9 34.9 23.6 62.5 15.4 47.4 45.4 31.8 28.8 21.5 RL 110 Caledonian

Caledonian Flame Retardant Data Cables www.caledonian-cables.co.uk www.addison-cables.com Maximum Attenuation /100m NEXT PSNEXT ELFEXT /100m PSELFEXT /100m 100 19.8 44.3 42.3 27.8 24.8 20.1 155 25.2 41.5 39.5 23.9 20.9 18.8 200 29.0 39.8 37.8 21.7 18.7 18.0 250 32.8 38.3 36.3 19.8 16.8 17.3 CONSTRUCTION PARAMETERS Cable Code Conductor Over Insulation Pairs Screen RL Overall mm mm mm Cat6 U/UTP 0.57/0.58 1.02 4 Nil 6.0 Cat6 F/UTP 0.57/0.58 1.02 4 Overall Aluminum Tape Screen 6.3 Cat6 SF/UTP 0.57/0.58 1.02 4 Overall Aluminum Tape Screen & Copper Wire Braid 6.6 EN 50173 N Rated Voltage Standard Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1 NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4 Zero Low Toxicity NES 02-713/NF C 20-454 Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074 Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073 IEC60754-1 EN50267-2-1 ADDISON 111

ADDISON Flame Retardant CAT6 CWB/SWB/SWA Armoured Data Cables FTX-CAT6 U/UTP4P24 cwb/swb/swa FTX-CAT6 F/UTP4P24 cwb/swb/swa FTX-CAT6 SF/UTP4P24 cwb/swb/swa LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation LSZH Inner Tinned Copper Drain Wire Braid or Wire Armoured APPLICATION Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables are with copper wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable. STANDARDS Basic design to EN50173 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test) (Vertically-mounted bundled wires & cable test) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* Smoke Emission IEC 61034-1&2; EN 61034-1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* No Toxic gases NES 02-713; NF C 20-454 Note: Asterisk * denotes superseded standard. VOLTAGE RATING 112 Caledonian

Caledonian Flame Retardant Data Cables www.caledonian-cables.co.uk www.addison-cables.com CABLE CONSTRUCTION Conductors: 23AWG solid bare copper. Insulation: HDPE. Twinning: Two coloured insulated conductors twisted together to form a pair. Inner : Flame retardant, low smoke and halogen-free polyolefin, coloured black. Armouring: cwb: copper Wire Braid swb: Steel Wire Braid swa: Steel Wire Armour Outer : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.) Cat6 F/UTP: These cables have collective shielding of aluminium/polyester tape with drain wire. Cat6 SF/UTP: These cables have double collective shieldings of aluminium/polyester tape & copper wire braid with drain wire. Physical AND THERMAL PROPERTIES Temperature range: -30 C ~ +75 C bending radius during installation (mobile state): 8 x Overall bending radius during operation (fixed state): 4 x Overall Electrical Properties AWG 23 Conductor mm 0.56/0.57 Maximum DC Resistant@20 C Ω/100m 9.38 Maximum DCR Unbalance % 3 Maximum Mutual Capacitance pf/m 5.8 Maximum Capacitance Unbalance pf/100m 30 Characteristic Impedance@1-100 Ω 100+/-15 Maximum Propagation Delay Skew ns/100m 18 Transmission Properties Maximum Attenuation /100m NEXT PSNEXT ELFEXT /100m PSELFEXT /100m 0.772 1.8 76.0 74. 70.0 67.0 1 2.0 74.3 72.3 67.8 64.8 20.0 4 3.8 65.3 63.3 55.7 52.7 23.0 8 5.3 60.8 58.8 49.7 46.7 24.5 10 6.0 59.3 57.3 47.8 44.8 25.0 16 7.6 56.3 54.3 43.7 40.7 25.0 20 8.5 54.8 52.8 41.7 38.7 25.0 25 9.5 53.3 51.3 39.8 36.8 24.3 RL ADDISON 113

ADDISON Maximum Attenuation NEXT PSNEXT ELFEXT PSELFEXT RL /100m /100m /100m 31.25 10.7 51.9 49.9 37.9 34.9 23.6 62.5 15.4 47.4 45.4 31.8 28.8 21.5 100 19.8 44.3 42.3 27.8 24.8 20.1 155 25.2 41.5 39.5 23.9 20.9 18.8 200 29.0 39.8 37.8 21.7 18.7 18.0 250 32.8 38.3 36.3 19.8 16.8 17.3 LSZH Outer Copper Wire Braid Armoured Aluminium/Polyester Tape Solid Copper Conductor PE Insulation LSZH Inner Tinned Copper Drain Wire Braid or Wire Armoured CONSTRUCTION PARAMETERS Cat6 SF/UTP Cable Code Construction No. of elements No. of cores in element Conductor diameter Insulation Inner Outer Overall Weight mm mm mm mm mm kg/km CAT6 U/UTP CWB 4 2 0.58 0.2 0.6 1.0 7.88 115 CAT6 U/UTP SWB 4 2 0.58 0.2 0.6 1.0 7.88 109 CAT6 U/UTP SWA 4 2 0.53 0.2 0.6 1.0 8.88 189 CAT6 F/UTP CWB 4 2 0.58 0.2 0.6 1.0 8.48 126 CAT6 F/UTP SWB 4 2 0.58 0.2 0.6 1.0 8.48 132 CAT6 F/UTP SWA 4 2 0.58 0.2 0.6 1.0 9.48 213 CAT6 SF/UTP CWB 4 2 0.58 0.2 0.6 1.0 8.96 154 114 Caledonian

Caledonian Flame Retardant Data Cables www.caledonian-cables.co.uk www.addison-cables.com Cable Code Construction No. of elements No. of cores in element Conductor diameter Insulation Inner Outer Overall Weight mm mm mm mm mm kg/km CAT6 SF/UTP SWB 4 2 0.58 0.2 0.6 1.0 8.96 148 CAT6 SF/UTP SWA 4 2 0.58 0.2 0.6 1.0 9.96 242 EN 50173 N Rated Voltage Standard Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1 NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4 Zero Low Toxicity NES 02-713/NF C 20-454 Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074 Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073 IEC60754-1 EN50267-2-1 ADDISON 115