Preventing Fires And Explosions In Pilot Plants And Laboratory Units

Similar documents
OUTLINE FOR FIRE PREVENTION ACTIVITY

NFPA 45 NFPA 211 NFPA 1600

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

SEMICONDUCTOR FABRICATION FACILITIES

Todd Jekel, Assistant Director, IRC Feb. 8, Standard Definition. What is a machinery room?

INTERNATIONAL STANDARD

SEMICONDUCTOR FABRICATION FACILITIES

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

(h) Pesticide Application.

Laboratory Safety Audit

Laboratories and Hazardous Materials. Company Overview

INSPECTOR I SKILLS ADMINISTRATION

Laboratory Safety Audit

GASEOUS HYDROGEN SYSTEMS

CO 2 Fire Extinguishing Systems

Installation Instructions Remote Blowers

Presentation to. IOSH Food and Drink Group. Danny McDougall Richard Perkin

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

Explosion Protection Engineering Principles

A. General Safety LAB/ROOM: INSPECTED BY: DATE:

Chapter 10: Laboratory Equipment

Engineering Standard. Saudi Aramco DeskTop Standards

Before proceeding with the selection process, let s briefly look at the various explosion protection options:

-SAMPLE- Safety Inspection Checklist: Manufacturing

MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

Knowledge Objectives (2 of 2) Fuel Gas Systems. Skills Objectives. Introduction. Fuel Gas Systems (1 of 6) 12/20/2013

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

NFPA 99 for Facility Managers

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas

Narrative Reports As Regulated by 780 CMR, Section 903.0

Intumescent Fire Dampers

Caresaver Universal Refrigerant Recovery Unit

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

Plant Processing and Extraction Facilities

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ENGINEER AND THE TECHNICIAN DESIGNING FIRE PROTECTION SYSTEMS.

USER S INFORMATION MANUAL

PART 2. Basic Code Requirements - Semiconductor & Microelectronic Facilities using HPM s

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

Survey of electrical equipment installed in hazardous areas on tankers

Part I Extraction Process Equipment

Correctly Classifying and Determining Fire Protection Requirements for High- Hazard Group H Occupancies in New York State (2010 codes)

HEALTH AND SAFETY INDUCTION CHECKLIST

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Requirements for ships carrying hydrogen and compressed natural gas vehicles

HOT WORK SAFETY PROGRAM:

Standard for tests for flammability of plastic materials for parts in devices and appliances

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Combustible Dust Hazard Recognition and Control NFPA Standards for Combustible Dusts

IMC Significant Changes Summary Tier I

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

University of California, Davis Laboratory Self-Inspection Checklist

DOUGLAS L. BARRY FIRE CHIEF

ICC Update - Laboratory Issues Code Changes / Proposals / Trends of Interest 10/2005

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Emergency shutdown systems. Procedures for bypassing ESD s

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

TetraTek, Inc. Regulatory. Compliance. Emergency Response. Nuclear Facility Compliance. Compliance. Fire Protection.

Design & Construction Standards, Revised January

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

Making sense of risk Risk engineering. Metalworking operations

RIDE WITH US. Natural Gas Vehicle Maintenance Facilities

LABORATORY EQUIPMENT. A. Section Accessibility for People with Disabilities. B. Section Plumbing Basic Materials and Methods

RAGAGEP UPDATE. Douglas Reindl, Director, IRC 2016 IRC R&T Forum

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

FIFTH CLASS POWER ENGINEER S

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016)

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SEF Presents: Common Questions for a Chemical Safety Program. Wednesday September 20, 2017

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

Description of the European standard EN 378: Refrigerating systems and heat pumps Safety and environmental requirements

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements

CLASS POWER ENGINEER S CERTIFICATE

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Public Input No. 3-NFPA [ Chapter 2 ]

Safety by Design. Phone: Fax: Box 2398, RR2, Collingwood, ON L9Y 3Z1

Fire protection on chemical manufacturing sites

PLAN REVIEW SUBMITTAL GUIDE

SECTION AIR COILS

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

SECTION (15530) - REFRIGERANT PIPING

Numerical Standards Listing

(Information about THERMAL dampers for gas-fired appliances available on request.) WARNING

POLICY STATEMENT: Policy Number: Section 600 Physical Plant. Date Adopted: May 7, Date(s) Revised: September 4, 2012

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

5.07 Air Replenishment Systems

Committee on NFPA 51A

WORKPLACE INSPECTION CHECKLIST FOR LABORATORY ENVIRONMENTS

DIRECTIVE NO: D-B

Laboratory Information

BUILDING/FIRE CODE REFERENCES 2006 EDITION

Transcription:

Preventing Fires And Explosions In Pilot Plants And Laboratory Units Richard Palluzi ExxonMobil Research and Engineering Co 1545 Route 22 East Annandale, NJ 08801 October, 1998 1

Introduction Pilot plants and laboratory units in petrochemical service pose a special risk of fire and/or explosion Routine handling of significant volumes of flammable materials Frequent elevated temperatures and pressures Novel operations October, 1998 2

Other Challenging Factors Exploratory nature of research Limited understanding of the chemistry Small size of the equipment Frequent need for unit modifications Need to ensure safety while still allowing research to continue October, 1998 3

October, 1998 4

October, 1998 5

October, 1998 6

Comprehensive Approach Required No single activity can ensure safety Ensuring safety requires many complementary and overlapping programs This presentation will discuss some of ExxonMobil s key areas which have proved successful October, 1998 7

Focus Design, construction and maintenance Numerous critical BBS and overall company safety programs and procedures also support and maintain a site wide safety culture October, 1998 8

Major Areas Preconstruction safety reviews Research specific standards Leak tight design Proper construction Area electrical classification Ventilation Proper storage Proper maintenance Control of change procedure October, 1998 9

Preconstruction Safety Reviews Key element in ensuring original design is safe Often preceded by other safety reviews for more hazardous operations conceptual safety review(s) preliminary safety review(s) October, 1998 10

Comprehensive Review Reviews proposed design in complete detail Piping Wiring Layout Operation Identify potential hazards: Equipment Layout Vessel design Materials Control systems Leakage Operations Fire/explosion Failure modes Etc. October, 1998 11

Assesses Proposed Design Assesses risks against a company wide matrix Recommends corrective actions where appropriate Recommends deviations and variances from approved standards/procedures where appropriate Approves proceeding to construction October, 1998 12

Research Specific Standards Ongoing effort since 1960 s Addresses research specific needs Over 60 standards currently exist New standards developed annually Existing standards continuously updated October, 1998 13

Research Specific Standards (cont d) Comprehensive review process across several different sites and organizations Standards include: Prescriptive designs for common recurring needs Performance requirements for varying needs Risk assessment guidelines for special cases October, 1998 14

Area Electrical Classification Chemical Storage Cabinets Compressed Gas Cylinder Location and Installation Conduit Sealing Fittings Decommissioning Deviation Procedures Electrical Furnace Installations Electrical Heaters In Electrically Classified Areas Electrically Heated Isothermal Sandbath Design Emergency Showers and Eye Wash Fountains Flow Limiting Devices Gas Compressors Gaskets Hot Boxes for Compressed Gas Cylinders Identification Of Pilot Plant and Laboratory Piping Illumination Guidelines Inert Atmosphere Dry Box (Glove Box) Installations Insulation Leak Testing Location of Utility Branch Line Isolation Valves Materials of Construction Nonmetallic Tubing and Hoses Over Temperature Protection Piping (General, Gas, Liquid and Liquefied Gas) Piping Inspection and Hydrostatic Testing Potable/Process Water Segregation Pressure Gauge Specification and Installation Pressure Ratings of Common Fittings Pressure Regulators Pressure Relief Devices Pressure Vessels Protective Shielding Requirements Pump Systems Quick Disconnects Reach Rod Design Pressure Relief & Overpressure Protection Rotameter Pressure Protection Systems Safety Shut Down Systems Sampling Systems Sewer Systems Steam Piping Symbols For Use On P&ID s Vent Lines Wet Meter Test Installation October, 1998 15

Standard Compliance is Mandatory Rigorous deviation procedure Engineering review Safety standards committee recommendation Site Standards Committee recommendation Management approval Deviations are routinely approved but only after careful review ensures that adequate mitigating measures are in place October, 1998 16

Leak Tight Design Specific designs with increasing levels of containment required for: More hazardous materials Multiple user systems Higher risk designs Specific components and equipment or performance based specifications often mandated for most leak free operation October, 1998 17

Continued Focus On Achieving Unit Integrity Pilot plant and laboratory start up and operations group to assist in initial start up as well as ongoing problems Provides additional specialty skills, training and equipment to assist operators Specific leak test procedures covered in safety standards Ensures safety and promotes efficiency October, 1998 18

Proper Construction Significant effort in quality control including: Uniform procedures Site wide training Proper design Proper component selection Proper installation Ongoing construction supervision October, 1998 19

Ongoing Effort Problems identified during start up are addressed through: Revised standards; Modified designs; Improved training; and/or Appropriate communications Considerable effort devoted to ensuring new tools, techniques and training are identified and deployed properly. October, 1998 20

Area Electrical Classification Detailed site standards for area electrical classification of all research areas Pilot plant areas Engine test cells Containment cells Laboratories Hoods Detailed drawings indicating the area electrical classification of all areas are maintained and followed October, 1998 21

Area Electrical Classification (cont d) In general, Class I Division 2 construction is mandated Safety standards provide alternate designs for some special research needs intended to ensure meeting intent while allowing more flexibility October, 1998 22

Examples Positive pressure enclosures General purpose construction for units with minimal inventories Ventilation barriers Equipment separation Barricades Special conditions and equipment October, 1998 23

Area Electrical Classification (cont d) Most hood interiors are electrically classified Even with high ventilation rates, releases have been found to cause fires and explosions before dilution This increases construction cost and difficulty but has proven to significantly reduce the potential for fires and explosions October, 1998 24

Experience Has Shown Area Electrical Classification: Minimizes the risk of explosions Reduces the risk of fire usually to a minor hazard Can accommodate almost all research needs Can be done with minimal adverse operational impact with careful design October, 1998 25

Ventilation All areas have strict ventilation standards Pilot plant and engine test cells: CFM/square foot of floor area Laboratories: Air changes/hour Hoods: Face velocity Both high and low point ventilation is required for pilot plant areas Proper ventilation patterns are also mandated October, 1998 26

Ventilation (cont d) Smoke tests are often required After new equipment is installed In difficult to assess situations As a final check Most areas are also continuously monitored for combustible and/or toxic materials Typically inside the pilot plant area, engine test cell or laboratory Typically outside the laboratory hood October, 1998 27

Local Exhaust Local exhaust is provided extensively Common uses include: Sampling Filling Draining and product collection Areas of high leak potential Components that need to be removed frequently Components requiring frequent maintenance October, 1998 28

Hoods Almost all laboratory units must be placed in a hood or ventilated enclosure These meet NFPA-45, ASHRAE 110 and AIHA Laboratory Ventilation requirements Site wide safety training addresses safe use and owner responsibilities Strong maintenance program ensures safe operation October, 1998 29

Hoods (cont d) Frequent surveys confirm proper use and operation Allows identification and early correction of problems Latest focus is addressing over crowded hoods Eliminating corresponding high turbulence and/or low draft areas October, 1998 30

Appropriate Storage Hazardous materials must be stored properly Full compliance with NFPA-45 and local building/fire codes mandated Gas cylinders not allowed in laboratories and pilot plant areas Stored outside or in separate cylinder storage areas Solvents stored in flammable storage cabinets whenever possible October, 1998 31

Appropriate Storage (cont d) Hoods not used for storage Quantities necessary for operations routinely challenged and reassessed October, 1998 32

Proper Maintenance Routine maintenance of all common safety equipment and systems is an integral part of ExxonMobil procedures All safety systems must be checked on a basis determined during the design Strong work permit and lock/tag out programs October, 1998 33

Site Wide Programs All relief devices are sized, issued from a central source and automatically checked Interval varies with service from annually to every four years Regulators issued from a central source and also automatically inspected Interval varies with service from annually to every four years All gas monitors calibrated quarterly No operator action required to initiate inspections October, 1998 34

Control of change procedure Changes required for all modifications no matter how trivial Level of review varies with identified hazard and assessed risk Both procedural and operational controls in place to ensure all modifications are reviewed before work is started Safety system access for modification or disabling tightly controlled October, 1998 35

Summary Preventing fire and explosions in a petrochemical research operation requires attention to numerous different areas Each area helps contribute to the overall safety of the research site The combination has helped ExxonMobil maintain a safe research environment October, 1998 36