BRA FACT FINDER Number 19

Similar documents
SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING

Understanding Applications for Alternate Refrigerants. Ron Bonear Emerson Climate Technologies

Refrigerant Glide and Effect on Performances Declaration

REFRIGERANT CHANGEOVER

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

System Considerations for Refrigerant Blends with Temperature Glide

R-407A R-448A R-449A

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

Comparative Performance of HFO Blends in a Condenser

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

TEST REPORT #2. System Drop-in Test of L-40, L-41a and N-40b in Ice Machines

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Understanding Applications for Alternative Refrigerants

Pressure Enthalpy Charts

Technical Training Associates Presents. Commercial Refrigeration Equipment Servicing Part 1

Understanding Applications for Alternative Refrigerants

Refrigerant changeover guidelines

Embraco Position Paper: Light Commercial Refrigeration

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Solstice 452A (R-452A) Reduced GWP and Discharge Temperature for Transport Refrigeration, Plug-Ins and Condensing Units

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

DOE and EPA Impacts to Commercial Refrigeration

R134a Refrigerant Charging Chart Trucks Mybooklibrary

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Gary Parker Refrigerants Product Manager

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

2016 Annual Conference

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Large AC units using a variety of low-gwp options

FACT SHEET 9 Large Air-Conditioning (air-to-air)

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

New Refrigerants & Selecting Capital Equipment

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

Gary Parker Refrigerants Product Manager

Guidance for Stationary Refrigeration & Air-Conditioning

Suction Accumulators. Introduction. Suction Accumulators

CHAPTER 1 INTRODUCTION

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

Overview of refrigerant alternatives in the air conditioning sector *

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

R-404A Alternative with Low Compressor Discharge Temperature

see notes on refrigerant type Refrigerant Type ASHR AE Refrigerant Composition (Mass % ) Zeotropes

Refrigerant & Energy Regulations Update

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

FACT SHEET 6 Transport Refrigeration

Low GWP Refrigerants for Air Conditioning Applications

The cold chain in the fishery sector. Refrigeration Technology Review

CO 2 transcritical FTE System Full Transcritical Efficiency

Designing evaporators and condensers for refrigerant mixtures with high temperature

Chapter 2. Alternatives to HCFCs and their Characteristics

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Use of hydrocarbon refrigerants in commercial refrigeration and air conditioning equipment

Tube-in-tube heat exchanger Type HE

THERMOSTATIC EXPANSION VALVES Part 2

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

COMPARATIVE PROPERTIES AND EFFICIENCY OF R-421A FOR RETROFIT USE TO REPLACE R-22

10/4/2013. The Changing State of Refrigerants

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

Guidance. Service of Hydrocarbon Refrigerant Equipment in a Retail Environment

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

ISSN Vol.08,Issue.21, November-2016, Pages:

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

The Essentials Of Working With R-410A

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Chillers for High Ambient Conditions: What Technologies and Fluids?

SOLSTICE L40X (R-455A)

Refrigerants and lubricants

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Scroll Chillers Transition from HCFC-22 to HFCs

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

Negative Superheat? Time to Check Your Tools

Evaluation of HCFC Alternative Refrigerants

RDT Refrigeration Book

Product Brochure 2018 NEW. Flexis. High-Wall Split Systems

RSES Technical Institute Training Manual 1 70 hours, 70 NATE CEHs, 7.2 CEUs

From the Field to the Supermarket

Refrigerant and Energy Regulations Update

Transcritical CO2 Bottle Cooler Development

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

The Saturation process

Honeywell Refrigerants. Retrofit Guidelines. R-404A/R-507A to: R-448A Solstice N40

Technical Information

Technical Bulletin (TB )

LECTURE-17. Multi-Stage Vapour Compression Refrigeration. 1. Introduction

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Transcription:

BRA FACT FINDER Number 19 Issue: 1 Date: March 2017 A practical guide to using refrigerants with a temperature glide This document is the second in a series of bulletins produced by the BRA following the publication of the PURR report (Putting into use Replacement Refrigerants). It is intended to provide advice for Service Engineers considering retrofitting high GWP systems. Some of the information will also be useful in the case of new installations. The guide is intended to cover single condensing unit and evaporator applications. R404A is the most commonly used high GWP refrigerant, and hence the replacement refrigerants identified in the PURR document have been used to illustrate the issues with retrofitting. These are supported with information from Component and Equipment manufacturers. Any comments with regard to R404A are equally applicable to R507. Potential Replacement Refrigerants for R404A R404A R407A R407F R448A R449A R452A GWP (AR4) 3922 2107 1825 1387 1397 2140 Glide K 0.8 6.4 6.4 6.1 6.1 6.4 Pressure @-10 C 3.4 2.2 2.6 2.4 2.6 3.0 Vapour (dew point) Pressure @-25 C 1.5 0.9 0.9 0.9 1.0 1.2 Vapour (dew point) Pressure @ 40 C 17.2 17.5 18.3 17.6 17.5 18.1 Liquid (bubble) Pressure @ 55 C Liquid (bubble) 24.8 25.2 26.2 25.2 25.3 25.9 The above table compares the replacement refrigerants currently available to replace R404A.

They all have broadly similar characteristics when compared to R404A: Wider Temperature Glide Higher compressor discharge temperatures Lower Mass flows Generally slightly lower suction pressures and slightly higher discharge pressures All classified as non-flammable and not subject to any flammability restrictions Although it will usually be possible to retrofit R404A with one of the replacements, they should not be considered as a Drop In, as some system adjustments will be necessary to ensure that the replacement refrigerant will operate efficiently. What is Glide? Refrigerant blends classified in the R400 series are mixtures containing a number of component refrigerants (between two and five depending on their intended performance). The scientific term for such a product is a zeotropic blend. Because the individual component refrigerants have different boiling points, the blend does not evaporate (or condense) at one temperature (at a given pressure), but over a temperature range this is referred to as the Temperature Glide. The Temperature Glide is defined as the difference between the Dew Point (when the refrigerant is 100% vapour) and the Bubble Point (when the refrigerant is 100% liquid) at a given pressure. Refrigerant slide rules and mobile phone apps will give both temperatures for any R400 series refrigerant, and hence the glide can be calculated. The glide will vary depending on the blend components; hence R404A has a glide of less than 1K, whilst R407A and F have a glide of more than 6K. As R404A has a very low glide, it has been possible to ignore this when setting up systems. However, ALL R404A alternatives (HFC and HFC/HFO blends) have a glide. Therefore, in setting up a system with one of these blends (whether retrofit or new build), the temperature glide must be taken into account to ensure that the system operates safely as intended, and so that its optimum performance can be obtained, whilst also ensuring the expected life time of the equipment. A characteristic of zeotropic refrigerants is that the composition of the vapour is different from that of the liquid. This is why it is recommended that ALL refrigerant blends should be charged in the liquid phase to ensure the correct composition is maintained. A question often raised is what effect does this characteristic have in the event of a leak?? Much work has been done over the years to understand this issue by refrigerant manufacturers. The conclusions are basically that in the event of a slight leak, a system can be topped up with the virgin refrigerant with no detrimental effect on system performance. HOWEVER, in the case of a severe leak (>50% of the charge lost), it is always safer to remove what refrigerant remains, identify and repair the leak, and re-charge the system completely with virgin product.

Retrofitting Systems In general high temperature systems e.g. chill food can be retrofitted to a lower GWP refrigerant, such as those listed, with minimal system modifications or changes being required. However for low temperature systems, the increased discharge temperatures may result in additional compressor cooling being necessary for systems such as frozen food. Information should be sought regarding individual compressor types or models. A number of hermetic compressor manufacturers have approved the use of R452A due to it having a lower discharge temperature than the other alternatives, although this is at the expense of a higher GWP. Published information is now available for Condensing Units with alternative refrigerants. In general for chill applications the condensing unit duty will be similar to R404A. The situation for frozen food applications is: For a typical freezer application with an evaporating temperature of around -25 C, condensing unit duties are likely to be similar to that when used on R404A For frozen food cabinets where the evaporating temperature is more typically around -35 C, there is likely to be a decrease in duty which will vary according to the refrigerant and the type of compressor. It is recommended that the performance and application range of condensing units fitted to frozen food cabinets should be checked prior to carrying out a retrofit. Due to the lower mass flow and different superheat characteristics of the replacement refrigerants, it will be necessary to consider whether to replace the expansion valve or use the existing one. Information on the use of existing expansion valves is available, but in general it is recommended to use a valve optimised for the refrigerant being used. For larger systems the use of an electronic expansion valve should be considered as this will enable easier setting up of the superheat. The pressure rating of the Pressure Relief Valve should also be checked as R407A/F, R448A and R449A have slightly higher discharge pressures than R404A. Pressure switches should be adjusted to cater for the different refrigerant pressures.

The Retrofit Process A number of refrigerant manufacturers have published guidelines on carrying out retrofits and these should be followed. It is essential that the system is re-commissioned and adequate time allocated to this. In particular that the expansion valve superheat must be adjusted to ensure that the refrigerant is 100% vapour when leaving the evaporator. This means that the superheat, when correctly measured between evaporator inlet and outlet, must at minimum exceed the value of the glide for that particular refrigerant. The measured superheat should be the sum of the glide and any superheat created by the expansion valve. If we assume that the superheat on a typical healthy R404A system is 6K, then on an equivalent system with one of the replacement refrigerants it will need to be 12K to ensure that no liquid refrigerant is allowed to leave the cooler and ensure the continued safe operation of the compressor. The following table shows the effect of temperature glide, when comparing R404A and R407F, operating on a freezer coldstore with a room temperature of -18 C and a design evaporating temperature of -25 C. As the temperature glide of R404A is less than 1K this has been ignored. It is assumed that the TEV superheat has been set correctly. Cold Store Temperature -18 C Refrigerant R404A R407F Design Evaporating Temperature C -25-25 Low Side Pressure 1.5 1.0 Temperature at TEV outlet -25-31 (bubble point C) Equivalent dew point temperature C -25-25 Glide K 0 6 Temperature at TEV bulb -19-19 (Dew point C) Temperature Difference between TEV outlet 6 12 and bulb K Superheat K (Temperature difference less glide) 6 6 Insufficient superheat will lead to lower duty from the evaporator and possibly liquid refrigerant entering the compressor. Below the two illustrations illustrate a refrigerant comparator showing comparison of Bubble Points and Dew Points for the above example.

R404A evaporating temperature -25 C R407F evaporating temperature -25 C 1 Useful References: Institute of Refrigeration Service Engineers Section Fundamentals and Theory series Measuring Superheat June 2010 Institute of Refrigeration Service Engineers Section Technical Bulletin No.2 Thermostatic Expansion Valves Institute of Refrigeration Service Engineers Section Technical Bulletin No.37 Zeotropic Refrigerant Blends October 2012 Institute of Refrigeration Guidance Note 27 Refrigerant Glide March 2016 BRA PURR Report September 2015 available at http://www.feta.co.uk/associations/bra/publications The BRA disclaim all liability to any person for anything or for the consequences of anything done or omitted to be done wholly or partly in reliance upon the whole or anypart of the contents of this Fact Finder