CR Series Command Relays

Similar documents
Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Honeywell Durafit LED Retrofit Kit

C7232A,B Sensor and Controller

T7079A,B Solid State Remote Temperature Controllers

T7984 A,B,C Electronic Modulating Control Thermostats

T7200D,E Series 2000 Commercial Microelectronic Thermostats

T6984F,G Electronic Floating Control Thermostats

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

IS Series Pressure Sensing Switches

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

Power Supply Display Module PSDM. Installation and Operation Manual

CR7075 Two-Stage Lighting Controller

RA889A Switching Relay

T834C Heating-Cooling Thermostat

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Operations Manual. Motion Detector Module Model ZS10

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

T6984 A,D,E Electronic Floating Control Thermostats

Emotron M10 Shaft Power Monitor. Instruction manual English

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

Q7800H Integrated Burner Control Subpanel

TP970 SERIES ASPIRATING WALL BOX ASSEMBLIES BEFORE INSTALLATION

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Commercial/Industrial Combustion Control Level Three Announcement

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Thermal Management Products & Accessories for Enclosures

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

MICRO SWITCH E6/V6 Series

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Operating Instructions. For. Alarm Control Module. Model SSR 500

4 & 8-POINT ANNUNCIATORS Instruction Manual

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

T7100D Microelectronic Conventional Thermostat

MICRO SWITCH BAF/DTF Series

HP970 and TP970 Series Standard Covers and Accessories

INTRODUCTION / TABLE OF CONTENTS

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

Powers Controls Low Temperature Detection Thermostat

T8411R Electronic Heat Pump Thermostat

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

T7350 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

Table of Contents. Protective Relays

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Remote Booster Power Supplies

MBCE-110/230UV Flame Sensor Module

AM Series Proportional Thermostatic Mixing Valve

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Sitron s CF Line of Flow Switch Monitors

Sensor Selection Guide. Sensing for Building Applications

Duct and Rough Service Carbon Monoxide Sensor

Vapor-logic 3 to Vapor-logic4

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Installation Instructions CS3 Three Phase Solid State Relay

D454.F.CE Product Guide

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

TC-5231 Series, TC-5232, & TC-5241 Series

FSW300 Series Flow Switch

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Must be installed by a trained, experienced technician

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

T4398A,B Precision Electric Heating Thermostat

T874 Multistage Thermostat and Q674 Subbase

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

Powers Controls ET 134 Low Temperature Detection Thermostat

CII FCAC-150 Series Relay

Inventory Management Guide

Installation, Operation, and Troubleshooting Instructions

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

T7047C,G,H Remote Space Sensors

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

Process Alarm Module RTA 421

Transcription:

CR Series Command Relays FEATURES INSTALLATION INSTRUCTIONS Patented 35mm Din-rail mounting flange (US Patent 7,416,421) SPDT Form 1C Relay contacts Pilot duty rated LED status indication Stackable for streamlined installation Can be used with any Honeywell analog current sensor or switch APPLICATION The CR (Command Relay) Series brings control (start/stop) functionality to your load trending and fan/pump/motor status monitoring applications. Each unit has a Form 1C-SPDT relay which means you have both a N/O and a N/C contact in the same unit. (See Table 1 for output ratings). The patented 35mm Din-Rail Mounting Flange (US Patent #7,416,421) will allow you to use the CR Series with any Honeywell analog current sensor or switch. This will reduce your inventory by not having to stock as many different items. The stacking feature will also allow you to reduce the required panel space, since up to two CR Series Command Relays may be stacked together during installation. The command relays are for use with: Motor control Lighting applications Interposing relay Control pumps/compressors Appliances/industrial equipment SPECIFICATIONS Din Rail: 35mm Dimensions: 34.32 mm W x 41.46 mm H x 33.52 mm D Unit Weight: 2 oz (0.125lb.) Enclosure: UL94-5VB / Burgundy Operating Temp: -15 to 40 C (5 to 104 F) Operating RH: 0 to 95% RH, non-condensing Status LED: All units Approvals: UL 508 (E179139) CE 62-0414-03

Table 1. CR Models. Part # Contact Rating Max. Switching Voltage Max. Switching Current CR-DC-5A 5A @ 250VAC General Use 5A @ 125VAC Resistive 5A @ 30VDC Resistive 1/4HP, 120/250/277VAC C150 Pilot Duty 5 A (NO)/3 A (NC) CR-DC-12A CR-12DC-12A CR-24AC-10A CR-115AC-8A CR-230AC-8A 12A @ 250VAC General Use 12A @ 250VAC Resistive 12A @ 30VDC Resistive 12A @ 250VAC General Use 12A @ 250VAC Resistive 12A @ 30VDC Resistive 10A @ 250VAC General Use 10A @ 250VAC Resistive 10A @ 30VDC Resistive 8A @ 250VAC General Use 8A @ 250VAC Resistive 8A @ 30VDC Resistive 8A @ 250VAC General Use 8A @ 250VAC Resistive 8A @ 30VDC Resistive 12 Amps 12 Amps 10 Amps 8 Amps 8 Amps 62-0414 03 2

TOP VIEW [2] Ø 3/16 (5) 1-5/16 (34) 1-7/64 (28) 2-57/64 (73) 3-19/64 (84) FRONT VIEW 1-33/64 (39) 1-5/8 (41) 1-11/32 (34) DIN RAIL SIZE M33142 Fig. 1. Dimensions in in (mm). INSTALLATION WARNING This product is not intended to be used for Life or Safety applications. WARNING This product is not intended for use in any hazardous or classified locations. WARNING Electrical Shock Hazard. Can cause severe injury, death or property damage. Disconnect and lock out all power sources before installation as severe injury or death may result from electrical shock due to contact with high voltage wires. INSTALLATION When Installing This Product 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in these instructions to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out operation as provided in these instructions. Make sure that all installations are in compliance with all national and local electrical codes. The Command Relays require an external power source for the relay coils (see Table 2). Table 2. Electrical Ratings. Honeywell Model # Coil Voltage Rated Current CR-DC-5A 23 to 31.2VDC 15mA @ 24VDC CR-DC-12A 20 to 31.2VDC 16mA @ 24VDC CR-12DC-12A 10 to 15.6VDC 30mA @ 12VDC CR-24AC-10A 16 to 26.4VAC 28mA @ 24VAC CR-115AC-8A 80 to 132VAC 10mA @ 115VAC CR-230AC-8A 165 to 264VAC 5mA @ 230VAC WARNING Electrical Shock Hazard. Can cause severe injury, death or property damage. Never rely on the Red LED to determine whether power is present at the command relay. The Red LED will indicate whether the relay coil is energized (LED On) or De-energized (LED OFF). 3 62-0414 03

1. The Command Relays may be mounted in any position using the (2) #8 x 3/4 Tek screws and the mounting holes in the base or snapped directly on to the 35mm DIN rail (see Fig. 2 and 3). 3X M33166 M33159 Fig. 4. Switches and sensors snapped to the command relay. Fig. 2. Relay placed on rail. 3X M33167 M33160 Fig. 3. Relay removed from rail. 2. The Honeywell current switches and sensors may be snapped directly on to the top of the command relays (see Fig. 4) or multiple command relays may be snapped directly on to the top of each other (see Fig. 5). Fig. 5. Multiple command relays snapped on top of each other. 3. Leave a minimum distance of 1 in (3 cm) between the command relays and any other magnetic devices such as contactors and transformers. WIRING Honeywell recommends the use of a 14 to 24 AWG wires, copper wire only for all command relay coil installations. The command relay DC coil terminals are polarity sensitive. Honeywell recommends the use of 12 to 14 AWG wires, copper wire only for all command relay contacts (Output) installations. The maximum tightening torque to be used on the terminal block connections is 0.6 Nm or 5.3 in-lbs. See Fig. 6 and 7 for sample wiring diagrams. 62-0414 03 4

ACI COMMAND RELAY N.C. COMMON N.O. CONTROLLER DO (RELAY COIL) CONTROL POWER CONTACTOR FAN/ PUMP/ COMPRESSOR MOTOR M33175 Fig. 6. Wiring with command relay. ACI SPLIT-CORE SWITCH CONTROLLER DI (STATUS) DO (RELAY COIL) ACI COMMAND RELAY CONTROL POWER CONTACTOR FAN/ PUMP/ COMPRESSOR MOTOR M33176 Fig. 7. Wiring with command relay and split-core switch. 5 62-0414 03

TROUBLESHOOTING Problem LED is on but the Command Relay didn t activate LED didn t turn on and the Command Relay didn t activate LED not on but the Command Relay is Activated Solution Disconnect the wires from the command relay output. Measure the resistance across the contacts with an Ohmmeter. Verify the voltage at the coil input See Table 1 on page 2. Disconnect the wires from the command relay output. Measure the resistance across the contacts with an Ohmmeter. LED not indicating correctly, may have been damaged WEEE Directive At the end of their useful life the packaging and product should be disposed of via a suitable recycling centre. Do not dispose of with household waste. Do not burn. 62-0414 03 6

7 62-0414 03

By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you. Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 customer.honeywell.com U.S. Registered Trademark 2012 Honeywell International Inc. 62-0414 03 M.S. Rev. 10-12 Printed in United States