Fire Risk Assessment

Similar documents
Fire Safety Policy. (The Regulatory Reform (Fire Safety) Order 2005) Last Reviewed: January Next Review: January 2019

EAST DEAN & FRISTON VILLAGE HALL FIRE RISK ASSESSMENT

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

KING S HOUSE SCHOOL FIRE RISK MANAGEMENT POLICY & PROCEDURES

FIRE SAFETY & EMERGENCY EVACUATION STRATEGY AND POLICY

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

Fire. This policy applies to all members of our school community, including those within the EYFS setting.

Fire Risk Assessment

1970s building housing main school reception and support offices. Well managed buildings with no significant risk of a fire occurring.

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Fire Risk Assessment Safety Checklist

Health & Safety Guidance

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Slight Harm Moderate Harm Extreme Harm Low Trivial Risk Tolerable Risk Moderate Risk Medium Tolerable Risk Moderate Risk Substantial Risk

Wellsprings Primary School. Fire Emergency Evacuation Plan

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

Well managed building mean risk is normal. Fire action notices should be displayed by all alarm break glass call points.

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

FIRE SAFETY RISK ASSESSMENT

STOCKLINCH VILLAGE HALL FIRE RISK ASSESSMENT

FIRE RISK ASSESSMENT

LYHA Fire Safety Policy

Fire Risk Assessment Borough High Street

FIRE SAFETY RISK ASSESSMENT

H&S Forum. Fire Safety Policy Glascote Academy

Fire Safety Risk Assessment for Treowen, Wonastow, Monmouth, NP25 4DL

FIRE PRECAUTIONS AND EMERGENCY EVACUATION PROCEDURES

Fire Safety Procedures & Risk Assessment Policy

Arbour House. Fire Policy and Procedures

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Fire Risk Assessment. Guidance Notes. Location details. Risk Rating. Assessors. General notes

Charlotte Building, 17 Gresse Street, London W1T 1QL

FIRE RISK ASSESSMENT

FIRE SAFETY POLICY. This policy refers to both Wellington Senior School and Wellington Prep School

Kings Fire Safety Policy

Fire Risk Assessment Guidance

Fire Safety Policy Date: 0

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School

Millfield Schools Fire Risk Prevention Policy

MONRO PAVILION RISK ASSESSMENT FORM. Date(s) Monday 1 Wednesday 3 July. External Contact & Nos Sarah Taylor - Venue Information

OAKTHORPE PRIMARY SCHOOL FIRE RISK ASSESSMENT POLICY NOVEMBER 2016

FIRE RISK ASSESSMENT CHECKLIST

Fire Safety, Procedures and Risk Assessment Policy

CONTRACTOR GUIDELINES

Sandwell Valley School and Sandwell Community Care Trust Training. 150 Birmingham Road, West Bromwich, B70 6QT

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

Fire Risk Assessment

UNIVERSITY COLLEGE LONDON PREMISES FIRE SAFETY HANDBOOK. Regulatory Reform (Fire Safety) Order 2005 DARWIN BUILDING

Fire Safety in Communal Areas Policy

FIRE RISK ASSESSMENT Self Assessment

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

GREAT DENHAM PRIMARY SCHOOL FIRE SAFETY POLICY September 2017

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

FIRE RISK ASSESSMENT

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

ST Edmunds Scout and Guide Headquarters. Fire Risk Assessment

PREMISES FIRE SAFETY LOGBOOK

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

FIRE POLICY ST.GEORGES AND OUR LADY QUEEN OF PEACE PARISHES OF WORCESTER INTRODUCTION. Fire is one of the most common workplace hazards.

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

St Edward s Oxford FIRE SAFETY POLICY

LEICESTER GRAMMAR SCHOOL TRUST FIRE SAFETY POLICY

Fire Risk Assessment

Bishopstone Village Hall Health and Safety and Fire Evacuation Policy

FIRE SAFETY IN PURPOSE BUILT BLOCKS OF FLATS

Fire Risk Management Policy. UK September 2017

FIRE PREVENTION, PROCEDURES AND RISK ASSESSMENT POLICY

Fire Safety. A TUC guide for trade union activists

Fire Safety Management Policy. This plan should be read in conjunction with the Health and Safety Policy.

A basic guide to... Fire Safety for Scout Premises

FIRE SAFETY POLICY. Adequate fire alarm systems that are tested at the required intervals

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

ST JOHN S (KINGSDOWN) VILLAGE HALL, UPPER STREET, KINGSDOWN, DEAL, KENT, CT14 8BJ Registered Charity Number

The Regulatory Reform (Fire Safety) Order 2005 Fire Risk Assessment Proforma

FIRE RISK ASSESSMENT NOT KNOWN 15/10/ SOMERTON COURT BROADMOSS DRIVE SIMON ROFFEY

Fire Risk Assessment - HMO (including accommodation with integrated fire systems)

Fire Risk Assessment. Index. Part 1 Introduction Part 2 The Fire Risk Assessment Part 3 The Management Action Plan

Fire Risk Assessment (FRA) Checklist

Following a near miss (after a fire or where evidence suggests that a fire could have occurred).

ChurchSafety InfoSheet: New Fire Regulations Regulatory Reform (Fire Safety) Order 2005

The Basement Risk Assessment Form

- CONSTRUCTION FIRE SAFETY STANDARDS

Byker Various post codes. Your Homes Newcastle Health and Safety (fire) Officer Date of Fire Risk Assessment 18 th February nd October 2014

Risk Assessment: Fire

Fire Safety Policy. Investing in success. Dukes Centre Dukes Avenue Kingston KT2 5QY 1. Policy

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

Fire safety procedure

Printing works and warehouse area Press Lane, 21 Ink Street, Presstown. PR3 3SS Postcode: Assessor signature:

Fire Safety, Fire Procedures and Fire Risk Assessment Policy. Three Schools Policy

SOUTHERN HEALTH NHS FOUNDATION TRUST

Fire Safety Audit: Part B - Questionnaire (Questionnaire Devised By Mr.R.R.Nair) Yes No x

Ealing Independent College. Fire Policy. This Policy Applies to all students and staff of Ealing Independent College

GHS 8-4 Fire Policy and Procedures

fire risk assessment For use by landlords of small premises Premises Address

University of London

FIRE EMERGENCY PLAN AND FIRE RISK (PREVENTATION) POLICY

FIRE PROCEDURES 1. APPOINTMENTS

ThamesWater Metering Managed Service. Office SHEQ Induction

Transcription:

Fire Risk Assessment Department The Cockpit Risk Assessment number PM/06/2015 Date. 17 th June 2015 Review due date 17 th June 2016 Activity: Fire safety risk assessment Location: The Cockpit Name of Assessors: Deb Jones Dave Wybrow Appendix A contains Legislation Considered: Regulatory Reform (Fire Safety) Order HSE Risk Matrix. Risk rating to be expressed numerically. Building information The Cockpit was built in the 1970 s with a steel frame and concrete with brick infill. Solid floor to ground, suspended plank to first floor. Roof is largely of flat construction with felt over stramite boarding. Windows are single glazed with a mixture of timber and metal frame. Main stair to upper floors is of cantilevered terrazzo. Doors to common areas are 30min fire type. Activities information The building is used for the rehearsing and production of plays, music, and other public entertainment. As well as in house productions, outside productions companies hire The Cockpit. They are required to conduct their own risk assessments and their manager and technical crew are given a briefing and given copies of the house rules.

Fire hazards assessed are: Possible sources of ignition. Sources of fuel. Who is at risk? Means of detecting a fire. Means of giving a warning. Means of escape. Means of fire fighting. Mandatory signage. Persons as risk These are staff, visitors, contractors and anyone else on the premises. Consideration should be given to seating person with mobility disabilities in an area they would not be overwhelmed by a rush to leave the auditorium. It is vital that staff practice evacuations and for helping disabled persons to quickly and safely leave the premises during an emergency evacuation. Means of Automatic detection Automatic heat/smoke detectors are situated throughout the building and the existing automatic fire detecting system is audible only. Consideration should be given to upgrading this with a link to a monitoring centre as a fire during the night may cause considerable damage before an alarm is raised. The current system is tested once a week by a member of staff and a record retained. Means of warning The alarm sounds at 65 decibels and is audible in every room throughout the building. Appropriate instructions on what to do in the event of a fire is given at staff inductions and fire training. This is reinforced with posters on the inside of all rooms, including; dressing rooms, work areas, studios, and office doors. Means of Fire Fighting A programme for training fire wardens is in place. The instructions are: on discovering a fire; raise the alarm by activating a fire call point and warning persons nearby. Only then and providing the person does not place themselves in undue risk should the fire be tackled using the fire fighting equipment provided.

Means of escape In assessing the means of escape, the following factors have been taken into account: Level of protection from fire spread on escape routes Number of people using the route Mobility of persons using the route Width and capacity of escape routes Time/distance to reach a place of (reasonable) safety Internal or external location of escape route Doors on escape routes Emergency lighting Signage The Safety Signs and Signals Regulations require approved signage, and are at the following locations; Manually operated emergency call points All fire fighting equipment Emergency evacuation routes Rooms have an evacuation plan on the inside of the door Emergency evacuation exits Sources of Ignition Room Action/Control Measure SH LR RL Battery charging, electrical switchgear Battery Room Regular maintenance and good housekeeping to remove rubbish and other combustibles. Warning signs displayed. Electrical switch gear and/or fuse board Workshop, Ground floor intake room and corridor Continue regular maintenance. Electric isolator to be identified to all visiting production companies technical crew. Warning signs displayed. Large amounts of electrical Control Room. Replace any equipment or leads which show signs of wear or

equipment Battery switch gear. damage. PAT testing to be carried out in accordance with the prescribed schedule of testing. Trip barriers to be in place to prevent overloading. Redundant leads to be isolated and removed or boxed in. Musical equipment and costume Store room in Studio 1 and workshop A water and CO2 fire extinguisher are to be placed in the room. The smoking ban must be enforced by staff or persons hiring rooms. 5 1 5 Large amount of cabling Technicians office A regular check by the venue or maintenance technician is to be carried out to reduce the likelihood of a build up of heat in coiled cables which may lead to a fire. Sources of fuel Room Action/Control Measure SH LR RL Wood, props, paint Workshop Carry out a regular check to remove excess stock and to maintain a minimum stock of flammable materials. Store flammable materials in fire proof metal cupboards. Maintain no smoking and no naked flame rules. Any hot work to have written risk assessment and the approval of the Cockpit Manager 5 1 5 Timber props Basement stores Remove unnecessary items before they become a hazard 5 1 5 Costume Basement stores Deploy water extinguisher 5 1 5 Hydrogen gas being produced during charging batteries Battery room Ventilation bricks to be kept free of obstructions, monitoring and maintenance of charger. Comserve (maintenance contractors) to carry out tests and any remedial action required.

Persons at risk Room Action/Control Measure SH LR RL Staff, incoming companies, contractors, visitors, studio hirers All areas Include fire safety procedures and rules in staff inductions. Familiarise all occupants with procedures, including practice of emergency evacuations. Provide visitors and contractors with safety information. No more than four wheelchair bound persons to be permitted on site during any performance. Safety literature sent to visiting companies in advance of their arrival, and published on our website. Members of the public Toilets, foyer, auditorium and seating area. Regular maintenance and good housekeeping to remove rubbish and other combustibles. Include fire safety procedures and rules in staff inductions. It is vital that staff practice evacuations and for helping disabled persons to quickly and safely leave the premises during an emergency evacuation. Means of detection Data Action/Control Measure Automatic fire alarm system Audible only Only effective when the building has persons on site. Recommended that the system is extended to a 24 hour alarm centre. Rooms within rooms Bar Office Control Box Workshop Studio 2 Maintain visibility through shutter Maintain visibility through vision panel Visible through panels Visible through vision panel Visible through vision panel Rooms where a fire may remain undetected for some time Basement Tank room Battery room Automatic fire detection to be installed at these locations

Technicians office View panel to be installed into the door of the technicians room (pending, meanwhile locks changed to avoid entrapment). Areas where dust may be produced Workshop Dust extraction systems to be activated whenever work that produces dust is undertaken within the workshop. This system needs to be tested to ensure the safe removal of airborne particulates. Every technician who works in a dust laden atmosphere must complete an industrial asthma self assessment form every 12 months. Means of Warning Room Action/Control measure Audible warning All areas The system is to be checked each week by a member of the staff and a record kept. The visual emergency alert in the Sound Box is to be tested at the same time. Means of Fire Fighting Data Action/Control measure Fire extinguishers See Fire Extinguisher positions document. To be visually checked each week by a member of staff and a record kept, and to be checked every 12 months by an engineer Means of escape Data Action/Control measure Listed on the floor plan all the doorways on the routes Emergency exit width: 1. Downstage left exit from auditorium 1.25m 2. Push bar exit to car park 1.2m 3. Boiler room doors 1.5m

4. Workshop exit to car park 1.1m 5. Backstage corridor to dressing rooms 1.1m 6. Backstage corridor to workshop/car park 1.1m 7. Backstage corridor to foyer 1.1m 8. From basement via male dressing room 1.1m 9. From basement via female dressing room 1.1m 10. Downstage right exit 1.1m 11. Downstage right exit to foyer 1.2m 12. From auditorium to foyer 1.5m 13. Auditorium to foyer 1.5m 14. Bottom of front stairwell 1.5m 15. Front entrance 1.4m 16. Gantry entrance 0.8m 17. Front roof exit 0.8m 18. east roof exit 0.8m 19. Racks room roof exit 0.8m 20. Corridor to front exit 0.8m 21 Landing to front stairs 0.8m List doors on escape routes that do not open in the direction of travel Door 10, doors 17 and 18 (roof) when being used for escape from the west side of the building this route needs to be signed as an alternate emergency exit Means of escape Data Action/control measure List internal doors on escape routes that do not have smoke seals or intumescent strips Doors 1, 5, 10, 15 Fit smoke seals List any holdes or gaps in walls, ceilings and floors, e.g where cables or pipes go through them Doors 6, 9, 10 Put fire-stopping material in gaps around pipes and cables

Escape routes across roofs Escape routes across the roof slipper in wet or icy weather A non slip surface to be provided along the roof escape route Signage Data Action/control measure Fire door, keep closed All fire doors have fire door keep closed sign Maintain fire door keep closed signs on all fire doors Management Action Plan To be completed by: Completed Date: Comments First aid training provided to key staff October 2015 October 2014 All staff to receive fire warden training March 2016 March 2015 To happen on a rolling basis 3 times a year, to ensure inclusion of all staff The ventilation in the battery room is to be checked by Comserve (maintenance company) and any remedial action taken Monthly Monthly Comserve check monthly Intumescent strips to be fitted into the fire doors identified, and also an audit taken to ensure they re all fitted October 2015 View panel to be installed into the door of the technicians office October 2015

Put fire stopping gaps above doors 6, 9, and 10 October 2015 Door 10, doors 17 and 18 (roof) when being used for escape from the west side of the building this route needs to be signed as an alternate emergency exit October 2015 Fire action notice to be placed above all call point and extinguishers July 2015 Connection of fire alarm to a monitoring centre Ongoing Pending quotes Procedure put in place to ensure clear fire route along the roof July 2014 July 2014 Complete Escape routes across roofs, a non slip surface to be provided along the roof escape route October 2015 October 2014 Has been done but needs to be re-done Assessors Name: Deb Jones Signature : Deb Jones Date 17 th June 2015 Name: Dave Wybrow Signature : Dave Wybrow Date 17 th June 2015

Appendix A The Regulatory Reform (Fire Safety) Order 2005 The Regulatory Reform (Fire Safety) Order 2005 which came into effect in October 2006 places the responsibility of fire precaution, fire suppression and detection onto the premises responsible person. The definition of a responsible person is; any person who has to any extent control of the premises. The order requires implementation of control methods that as far as is reasonably possible reduces risks to an acceptable level for employees, non-employees and those affected by their activities. Risk of Fire Good Practice Good Housekeeping to be carried out. No unauthorised electrical equipment to be used. Fire Risk Assessment under RRFSO to be reviewed annually. Desks and work areas to be kept clear of unnecessary paper. Vents on computers to be kept clear.

Likelihood Severity No Injury First Aid Injury Lost Time (Over 3 days) Major Injury or Disabling Disease Death Improbable 1 2 3 4 5 Remote 2 4 6 8 10 Possible 3 6 9 12 15 Probable 4 8 12 16 20 Very Likely to Occur Risk Rating 16 to 25 5 10 15 20 25 Action Required High risk and may require the provision of considerable resources involving special equipment, training, high levels of supervision and consideration of the most effective methods of eliminating or controlling hazards. 6 to 15 Medium risk and will require an appropriate level of resources. 1 to 5 Low risk but actions should still be taken to try to reduce these risks further, if possible, within reasonable limits.