HUMIDITY AND TEMPERATURE CONTROLLER

Similar documents
ULTRASONIC HUMIDIFIER UHF

ULTRASONIC HUMIDIFIER

AIR HANDLING UNITS RESISTORS HUMIDIFIER: REH

INSTRUCTION MANUAL. PLASTIC MENDER mod. ITA

NRS1/NRS1-R RAIN SENSOR LOW TENSION HEATED RAIN SENSOR (R-RADIO VERSION) MANUAL FOR INSTALLATION AND USE. Symbols used in the manual.

USER S MANUAL. Rectifier 1 10 A/10 48 V for Kliar Line Art

SWITCHING POWER GENERATOR FOR 0.9 & 1.2 KW MAGNETRON TECHNICAL NOTE

Firefighting units constructed in compliance with UNI EN and UNI standards

USER S MANUAL. 4 5-liters Tanks e- coating and galvanic Plant with Ultrasonic Art

Regulation EASY CLIMA VERSION 1.6 TECHNICAL MANUAL

ELECTRONIC HUMIDISTAT: H200

PLATING DIVISION. LEGOR GROUP S.p.A. Via del Lavoro, Bressanvido (VI) Italy - tel fax

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

INSTALLATION & USER MANUAL

Humidity Controller Specification and Installation Instructions. Model HRO20

I/O logger box. User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT!

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

eed quality electronic design USER s MANUAL

SCHMIDT LED Measured Value Display MD Instructions for Use

± 3% or better at 40%RH and 23ºC [73ºF] 0.8 mm 2 [18 AWG] minimum

Plug-n-Play Humidity Controller. IHC-200 User Manual. Version 1.3s. Inkbird Tech. Co., Ltd.

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Intellicomfort CH140GSM

ELECTRONIC HUMIDISTAT: H270

CHATTANOOGA JUNIOR STAR

Chiller Organizer 2/3

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

LCF Touch Modbus Datasheet Application Security Advice Caution

EasyTech.Full Temperature Controller for Pellet Stove. Idro

LaserPoint srl - Via Burona, Vimodrone (Milano) - Italy Phone Telefax

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

CFR1 05 I N S T R U C T I O N S MANUAL C F R : I N S T R U C T I O N S A N D M A I N T E N A N C E M A N U A L

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

LCF Touch. Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet. Application. Security Advice Caution.

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

ECP200 EXPERT. Use and maintenance manual READ AND KEEP ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS REV ING

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

ECP200 BASE 2 / 4. Use and maintenance manual READ AND KEEP ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS REV ING

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Two-Channel Gas Controller

N M AirControl AHU. Control manual

Danfoss gas detection units

TEMPERATURE CONTROLLER (STANDARD MODEL)

WIO200 Water in oil sensor

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Control of the system, MLP RO pump station

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

LCF Touch (from firmware version 1.7)

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

GB-DAS. Installation and user manual DEVIreg 850 controller

Temperature & Humidity Controllers

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

WILLHI WH1436H Digital Humidity Controller Manual (NEW VERSION)

EC2-5x2 Series Condensing Unit Controllers

Electronic Temperature Controller 70304,

Gas Controller Module GC-06

Room thermostats with LCD for wall mounting

Process Alarm Module RTA 421

TURBO

WIO200 Water In Oil measuring instrument

PolyGard 2-channel Gas Controller MGC-03

PHOTOVOLTAIC HEAT CONTROLER PVHC 2.01 USER MANUAL

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

INSTRUCTION FOR THE USER THC V E OIL BLU

ST 53.1 User s manual

KM300 Carbon Monoxide Detection System Installation Manual

Danfoss gas detection units

INSTALLATION AND OPERATING MANUAL

Manual. Controls. Basic Comfort Comfort Plus

RE-PR3-E-27 3-Phase Panel Mount 27kW

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

Thermal protection device for electric units

Options for Diesel Fire Pump Controllers

BSR Addressable Fire Detection control panel. Installation operation manual

Room thermostat with Auto Timer, Option External Input

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Premier External TD. Installation Manual INS352-3

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Manual & Technical Documentation V1.1

Smart thermostat with Humidification/De-humidification control

E-COMBI EVO E-SYSTEM EVO

Power Supply Display Module PSDM. Installation and Operation Manual

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Instructions for the fan motor control system, SILVER C

FEMA ELECTRÓNICA. Panel meter for Pt100/RTD (2 and 3 wires), and thermocouples J, K, T, E, S, R, N, C,

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

EC Series Wall Unit Humidifier

DC200 Digital Dispenser Operating Manual

5230IG. Thermotouch 3.2aP Wireless Heating Thermostat

OGB Poly Care 2 Incubator Service Manual

Transcription:

HUMIDITY AND TEMPERATURE CONTROLLER HT INSTALLATION, MAINTENANCE AND USER MANUAL Elsteam S.r.l.. Ver. 14.01.UK

ToC 1. PACKAGE CONTENT... 3 2. SECURITY MEASURES... 3 1.1 GENERAL MEASURES... 3 1.2 THERMO-HYGROMETRIC CONDITIONS OF THE INSTALLATION... 3 1.3 WASTE DISPOSAL... 3 1.4 WARRANTY... 3 3. MANUFACTURER... 4 4. 4 CONFORMITY DECLARATION... 5 5. WORKING PRINCIPLE... 6 6. CHARACTERISTICS... 6 7. HT CONTROLLER BEHAVIOUR... 7 8. HT CONTROLLER PROGRAMMING MENU... 7 9. ELECTRICAL CONNECTIONS... 8 10. HT CONTROLLER BOARD (COMPONENT SIDE)... 9 11. HUMIDITY/TEMPERATURE PROBE CONNECTION (LINPICCO A420):...10

Please before using your equipment read this guide carefully, by noting all the precautions and safety instructions reported in it. Keep your equipment in good operative conditions. Familiarize with the working and security instructions related to the operation of your apparatus before trying to make it function. Keep this guide and any other booklet provided with your apparatus to be able to refer to them later. 1. Package content HT controller packaging contains: The controller The humidity and temperature probe (LINPICCO-A420) This user guide A single-phase 230 Vac // 0-12 Vac transformer (option) 2. Security measures 1.1 General Measures People who are not familiar with this type of equipment or who have not read this manual carefully should not be allowed to use the humidifier Your controller has been designed to be used with AC voltage 12V or 230Vac 50/60Hz if the optional transformer is bought. Do not attempt to use the humidifier with a different kind of power supply. Check that the mains voltage corresponds to that of the controller. Your controller must always be turned off before any maintenance. All maintenance and repair work must be performed by the manufacturer, its service agent or qualified service personnel. 1.2 Thermo-hygrometric conditions of the installation Make sure that the environmental conditions of the place where the humidifier is installed are compatible with the requirements of the product as specified in this manual. Each product Elsteam cannot be installed exposed to the weather or freezing temperatures, unless different terms are explicitly expressed in related document. 1.3 Waste Disposal Directive 2002/96/EC of the European Parliament and the relevant national rules impose an obligation not to dispose of WEEE as unsorted municipal civil, but to set up a special collection for obsolete parts of the humidifier. It is still given the option to the buyer to return the humidifier into disuse at Elsteam Ltd. in case of purchase of an equivalent humidifier. Elsteam will dispose of them in their own or through its agents. The disposal of electrical or electronic components in an abusive manner and not in accordance with applicable regulations is forbidden by the law. In the event of illegal disposal of electrical and electronic waste, the penalties are specified by local waste disposal legislation. 1.4 Warranty Elsteam S.r.l. acknowledges to its products guarantees of law applicable at the time of sale of the product, and in any case guarantees at all times, even ten years after the sale, the free replacement of

components which considers the apparent problem of construction. Misuse and lack of maintenance will be automatic forfeiture of any form of guarantee. 3. Manufacturer Manufacturer Elsteam S.r.l. Sede legale amministrativa Via ENRICO FERMI 496, 21042 CARONNO PERTUSELLA (VA) - ITALY Contatti Tel.: (0039) 029659890 Fax: (0039) 0296457007 Email: infocomm@elsteam.com Web: www.elsteam.com

4. 4 Conformity Declaration ELSTEAM S.r.l. Azienda IL COSTRUTTORE Via Enrico Fermi, 496 21042 VA Indirizzo Cap Provincia Caronno Pertusella Città Italy Stato DICHIARA CHE LA MACCHINA Umidificatore a resistenze Descrizione Modello REH REH 2013 Serie/Matricola Anno costr. Umidificatore Proporzionale ad Alta Pressione Denominazione commerciale Umidificazione di ambienti Uso previsto E conforme alle direttive comunitarie 2006/95/CEE Direttiva Bassa Tensione del Consiglio 27 Dicembre 2006 89/336/CEE Compatibilità Elettromagnetica EMC modificata da: - Direttiva 91/263/CEE del Consiglio del 29 aprile 1991 - Direttiva 92/31/CEE del Consiglio del 28 aprile 1992 - Direttiva 93/68/CEE del Consiglio del 22 luglio 1993 - Direttiva 04/108/CEE del Consiglio del 15 dicembre 2004 Claudio Cattaneo Responsabile Dirigente Funzione Claudio Cattaneo Responsabile Dirigente Funzione 2013 Anno

5. Working Principle Elsteam HT controller is a programmable humidity and temperature controller. operational modes: It has following Hygrostat + Thermostat (default) Thermostat Hygrostat Thermostat operational mode can be programmed for cooling or heating; Humidistat mode can be programmed for humidifying or dehumidifying. 6. Characteristics Technical characteristics Input 4-20mA humidity probe PT1000 temperature probe RS485 (not available) Output 1 ON/OFF output (relay) Temperature heating 1 ON/OFF output (relay) Temperature cooling 1 ON/OFF output (relay) Humidity humidifying 1 ON/OFF output (relay) Humidity dehumidifying 1 linear output (0-5V) Temperature 1 linear output (0-5V) Humidity 1 output Attivazione (+5V o +12V) 1 ON/OFF output (relay) Alarm Power Supply Power Dimensions [mm] LxPxA Weight [kg] Electrical Connections 12Vac o 12Vdc Mechanical 6,5x6,5x16 cm

7. HT controller behaviour The controller has two lines display and 4 keys keyboard: SET OK + - During normal operational mode, press SET key to enter/exit programming mode. Buttons + and - are used to move between items in menu or increase/decrease parameters value. OK key is used to confirm parameter value. By pressing + or - buttons while not modifying a menu parameter allows the user to change display data: Temperature Humidity Set Point Date Time 8. HT controller programming Menu To move between menu items use + and - buttons. Language: o Italian (default). o English. o French. Working Mode: o Hygrostat + Thermostat (default) o Thermostat o Hygrostat Thermostat working mode (if thermostat mode selected): o Heating (default). o Cooling. Hygrostat working mode (if hygrostat mode selected): o Humidifying (default). o Dehumidifying. Temperature set point (if thermostat mode selected). Humidity set point (if hygrostat mode selected). Temperature hysteresis (if thermostat mode selected): default 1 C. Humidity hysteresis (if hygrostat mode selected): default 3%. Temperature threshold 1 (if thermostat mode selected): default 15%. Humidity threshold 1 (if hygrostat mode selected): default 15%. Alarm: default: OFF. Alarm Hours (if alarm on): default 1h o If alarm is on relay is activated if the parameter does not reach the set point within parameter value time (hours) Last alarm: display information concerning last occurred alarm. Alarm string: string to display during alarm conditions (ex. assistance phone number) Time setting Day setting 1 If the value passes the set point (temperature /or humidity) by parameter value the linear output reach 100% (5V).

9. Electrical Connections Pin Description 1 Power Supply 0Vac. 2 Power Supply 12Vac. 3 Output +12 Vcc. 4 GND 5 RS485-A (not used) 6 RS485-B (not used) 7 Linear Output 0 5Vcc humidity 8 Linear Output 0 5Vcc temperature 9 GND current loop input (4-20mA humidity probe) 10 PT1000+ Input (temperature probe) 11 PT1000- Input (temperature probe) 12 ON/OFF output +V (+V can be set to +5Vcc or +12Vcc at farm). Default 12Vcc 13 Alarm Relay contact 14 Alarm Relay contact 15 Humidity Relay 1 contact (humidification) 16 Humidity Relay 1 contact (humidification) 17 Humidity Relay 2 contact (dehumidification) 18 Humidity Relay 2 contact (dehumidification) 19 Temperature Relay 1 contact (heating) 20 Temperature Relay 1 contact (heating) 21 Temperature Relay 2 contact (cooling) 22 Temperature Relay 2 contact (cooling)

10. HT controller board (component side)

11. Humidity/Temperature probe connection (LinPicco A420): LinPicco A420 Probe rear connections Connections A420 Controller W5 PT1000 Pin 10 W6 PT1000 Pin 11 W10 Current Loop Vcc+ Pin 3 W7 Current Loop Return Pin 9