INFORMATION SHEET TAS2KW1100 BELIEF AIR HEATER KIT

Similar documents
INSTALLATION INSTRUCTIONS PT-A HEAT/AC STANDARD KIT FORD E-SERIES VANS

Forced air mobile diesel heating systems.

1. AirTop Air Heater. 2. AirTop Heater Kit. 3. AirTop Evo Air Heater. 4. ThermoTop Water Heater. 5. Isotemp Water Heaters

Forced air mobile diesel heating systems.

Dreison International Inc. TURBO Precleaners. Pow-R-Quik Starters. Marion Fluid Power. HydraMotion. SuperTrapp Industrial Mufflers

YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER

Forced air mobile diesel heating systems.

A HEATER KIT With Diesel Engine Connection Fittings

TOOLS REQUIRED: Crimping tool A/C Recovery Unit Wrench set up to 1 ¼ 4 Hole saw

VA175 SOLDAVAC. Air and Vacuum Pick-Up System

CLIMATE EBERSPÄCHER DIESEL HEATERS MOBILE LIVING MADE EASY.

REPLACEMENT PARTS MANUAL

EBERSPÄCHER DIESEL HEATERS

HEATING. Additional heating

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Homestyle Stack Washer/Dryers

DaVinci Heat Exchanger

Product Support Bulletin

Calaer Marine add-on kit manual. 2kW Calaer air heater 4kW Calaer air heater

Home Stack Washer/Dryers

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw

Home Stack Washer/Dryers

DaVinci Heat Exchanger Touch-Screen Version

Installation manual. 2kW Calaer air heater 4kW Calaer air heater

Homestyle Stacked Washer/Dryer

BlueHeat Coolant Heater

BlueHeat AirTop 2000 Heater

Webasto UK Product Catalogue. Valid from January 2015

CONTENTS. 1. Planning The Installation Installation Trial Operation Final Check Wiring Diagrams...

Homestyle Stacked Washer/ Dryer

Truma Combi D 6 AU. Installation instructions Page 2

Homestyle Stacked Washer/Dryer

CYCLONE XHE - MODEL BTH-300A/400A See Page 2

INSTALLATION INSTRUCTIONS

Air Heater. Air Top 3500 Diesel. Supplemental Installation Instructions for: Van Body Vehicles

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

COMPLETE HEATING SYSTEMS FROM ESPAR

Accessories. Safety Shut-off Valves. Certifications. Accessories. ASV375NT Safety Shut-off Valve. Combination Gas Control/Valve

Ultra Boiler Series 1 & 2 Jacket Parts

27" GAS DRYER MODELS: MGD7100DW0 (White) MGD7100DC0 (Chrome Shadow) 05/08/ Maytag Part No. W Rev. A

Retrofit an evacuated tube collector to an existing cylinder Updated

INSTALL INSTRUCTIONS KK-S-HVAC SPRINTER VAN REAR HVAC SYSTEM

29" GAS DRYER MODELS: MGD7000AW1 (White) MGD7000AG1 (Cosmetallic) 07/02/ Maytag Part No. W Rev. A

Home Stacked Washer/Dryer

4111 Cab Parking Heater Affects: Related:

COMPACT 3020 HE COMBI BOILERS

INSTALLATION MANUAL PROHEAT A2/A4

INFRARED RADIANT HEATERS

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6

Operating instructions for the DA 8-2 Extractor

OASIS NE-S Heating System

Service life twice as long (6,000 operating hours). Automatic altitude adjustment of the Hydronic M10 / M12 up to 3,500m.

RECON Strobe Install. Here I Will Explain How To Install RECON s 90 Watt Strobe Kit. You Should Have:

HVAC SYSTEMS COMMERCIAL VESSELS

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

OASIS NE Heating System

OFFICE of the FIRE COMMISSIONER. Recreational Vehicles Life Safety Requirements

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

WASHER & DRYER REPAIR

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

INSTALLATION AND USER INSTRUCTIONS

OASIS Heating System. Installation and. Operating Manual. Diesel and AC Heating System for Recreational Vehicles and Yachts

GAS DRYER MODELS: (White) (Chrome Shadow) 01/28/ Sears Brands, LLC Part No. W Rev. A

Gas and Electric 4kW Space Heater SH4312B/ SI4312B INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

MODULES. Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

GAS DRYER MODELS: MGD8200FW0 (White) MGD8200FC0 (Chrome Shadow) 05/24/ Maytag Part No. W Rev. A

BlueHeat Coolant Heater

27" GAS DRYER MODELS: WGD95HEDW0 (White) WGD95HEDC0 (Chrome Shadow) 05/13/ Whirlpool Corporation Part No. W Rev.

CABS/BLADES/ SPREADERS/ACCESSORIES

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

MOUNTING INSTRUCTIONS

abt W Lamp Paraffine Oil n. 0,125 l/h 12 V = (11-14,5 V) 220 x 285 x 115 mm

27" GAS DRYER MODELS: 7MWGD87HEDC0 (Chrome Shadow) 08/19/ Whirlpool Corporation Part No. W Rev. A

HOT WATER BOILER ( MBH)

CHAPTER 11 HEATING AND VENTILATION

OUH Suspended Oil Unit Heater

Recreational Vehicle RRP List. valid from January 2013

Commercial Stacked Washer/ Dryers

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

DESIGN CLASS FUNCTION

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

Marine Catalog

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

GAS DRYER MODELS: WGD8000DW0 (White) 03/30/ Whirlpool Corporation Part No. W Rev. C

Flue & Flue Kits for NVx, VPC & NVS

VERTICAL POWER VENT KIT

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400TRLT INDIRECT FIRED HEATER TRAILER

Parts Catalogue. /

IN020 Rev F Page 1 of 8

Please Read and Save These Instructions.

For more Parts Information:

COMBUSTION AIR SYSTEM

Everest Star 7900 II Series and 8012II

Transcription:

INFORMATION SHEET TAS2KW1100 BELIEF AIR HEATER KIT TOOLS & ASSOCIATED SALES IMPORT FROM CHINA TAS2KW BELIEF HEATERS WITH THE FOLLOWING SPECIFICATIONS SPECIFICATIONS HEAT POWER (W) 2000 2KW RATED VOLTAGE 12V DC FUEL CONSUMPTION 0.12-0.24L/HOUR RATED POWER CONSUMPTION WATTS 14-29 WEIGHT OF HEATER 2.6KG SIZE 311 X 120 X 121MM SIZE BASE PLATE 168 X 200MM WE SERVICE AND CARRY PARTS FOR ALL OUR HEATERS KITS AND THE UNIT COMES WITH 12 MONTHS PARTS AND LABOR RETURN TO BASE WARRANTY

TAS 2KW BELIEF HEATER UNIT WIRING LOOM TAS1100 HEATER KIT KIT COMPONENTS FUEL PUMP HARNESS FUEL PUMP FUEL LINE NYLON X 5M BUNDLE CABLE TIES CONTROL SWITCH BITS BAG\FILTER\JOINERS COMBUSTION AIR PIPE EXHAUST PIPE 24MM X 1M COMBUSTION AIR PIPE SILENCER + CLAMP PUMP SILENT MOUNT PIPE SILENT MOUNT ELBOWS FUEL LINE SILENT CLAMP AND INSULATION X 2 EXHAUST /FUEL PUMP MOUNTING BRACKET EXTRAS THAT COME IN OUR KITS EXHAUST MUFFLER 24MM + CLAMPS X 3 + 22-24 MM ADAPTER MOUNTING PLATE HEAVY DUTY 60MM DUCTING + 2 CLAMPS VENTS AND GRILLS NON DIRECTIONAL X 2

10L EASY FIT FUEL TANK SUPPLIED WITH TAS1100 KIT 10 L PLASTIC FUEL TANK QUICK CONNECT COUPLING MALE QUICK CONNECT COUPLING FEMALE FUEL STRAW FITTED TO FUEL TANK FUEL FILTER FITTED TO TANK FUEL PUMP FITTED TO TANK USING SILENT MOUNT SILENT ELBOWS X 2 FITTED TO TANK TANK BREATHER SPLASH BOX TANK BREATHER FUEL STRAW FITTED QUICK CONNECTS SELF SEALING COUPLINGS FUEL FILTER SPLASH BOX CONTAINS FUEL SPILLS SILENT ELBOWS REDUCES PUMP NOISE SILENT MOUNT REDUCES PUMP NOISE 5L EASY FIT FUEL TANK FOR EXTERNAL FITTING (OPTION) TOOLS & ASSOCIATED SALES P\L 166 DIXON POINT ROAD SANDFORD TAS 7020 WEB ;WWW.DIESELHEAT.COM.AU EMAIL: DIESELHEATAUST@GMAIL.COM MOBILE : 0418 130971

BASIC FITTING INSTRUCTIONS ARE AS FOLLOWS HEATER IS MOUNTED TO A STAINLESS STEEL HEAVY DUTY PLATE HEAVY DUTY STAINLESS STEEL FLOOR MOUNTING PLATE EXHAUST, AIR COMBUSTION PIPE AND FUEL PIPE IS CONNECTED TO HEATER BASE 145MM HOLE IS CUT THROUGH THE FLOOR AREA TO OUTSIDE ENVIRONMENT HEATER WITH BASE IS SCREWED TO FLOOR AND SEALED WITH SILICON HOT AIR DUCTING, WIRING LOOM AND CONTROL SWITCH IS CONNECTED INSIDE FUEL DOSING PUMP, EXHAUST, MUFFLER MOUNTED UNDERNEATH FUEL LINE CONNECTED TO DOSING PUMP AND RUN TO FUEL TANK SUPPLY POWER SUPPLY CONNECTED DIRECTLY TO BATTERY BANK FUEL TANK MOUNTED EXTERNAL OR INTERNAL DEPENDING ON REQUIREMENTS HEATER OPERATION OUR TAS2KW HEATERS HAVE ADJUSTABLE RHEOSTAT CONTROLLERS FULLY ADJUSTABLE FROM LOW TO HIGH; IT HAS 2 MODES OF OPERATION (1) TEMPERATURE SENSE OPERATION IN THIS MODE THE HEATER SENSES HEATED AIR ON THE COLD AIR INPUT SIDE OF THE HEATER AND WILL REGULATE THE HEAT OUTPUT BY SLOWING DOWN THE FUEL SUPPLY AND SLOWING THE FAN SPEED, IF SET TOO LOW THE HEATER WILL CYCLE ON AND OFF WITH THE HEATER GOING THROUGH STARTUP AND SHUT DOWN CYCLES, THIS USES 12 AMPS ON STARTUP AND 2 AMPS ON RUN, THIS CREATES A LARGE DRAIN ON BATTERY RESOURCES (2) HEAT OUTPUT OPERATION IN THIS OPERATION THE HEATER CAN BE TURNED DOWN AND CAN BE REGULATED BETWEEN 1-2 KW, THE BURNER WILL CONTINUE TO RUN AND WILL NOT COMPLETELY TURN OFF, SO IT WILL NOT GO THROUGH THE 12 AMP STARTUP PROCEDURE AND ONLY DRAWS AROUND 1-2 AMPS IT IS A LOT KINDER ON BATTERY RESOURCES (3) NOISE WE SUPPLY IN OUR KITS AS STANDARD BOTH EXHAUST MUFFLERS AND COMBUSTION AIR SILENCERS, THIS REDUCES THE EXTERNAL NOISE CONSIDERABLY IT IS NOT SO MUCH FOR YOU INSIDE BUT FOR OTHER PEOPLE CAMPING AROUND YOU. WE HAVE SPENT CONSIDERABLE TIME IN REDUCING THE TICKING NOISE THAT IS PRODUCED FROM THE FUEL PUMP, OUR KITS HAVE SILENT MOUNTS,AND SILENT RUBBER ELBOWS TO MAKE THE PUMP QUIETER

EXAMPLES OF FITTING

FUEL TANK INFORMATION FUEL CAN BE DRAWN FROM THE VEHICLES FUEL TANK FOR MOTOR HOMES THIS MAY REQUIRE REMOVAL OF THE FUEL TANK AND INSERTING A FUEL STRAW PROVIDED IN THE KIT, SOMETIMES THIS IS NOT PRACTICAL SO SUPPLEMENTARY FUEL TANKS CAN BE FITTED, WE USE 6 BASIC TYPES 5L/10L/20L SQUAT/20L MILITARY AND 12L SQUARE, THESE ARE USED IN CONJUNCTION WITH QUICK CONNECT COUPLINGS FOR EXTERNAL FILLING AND SPLASH CONTAINERS FOR INTERNAL FITTING ALL COME WITH EXTERNAL BREATHERS FITTED, FOR CARAVAN MOTOR HOMES FUEL TANKS CAN BE FITTED INTERNALLY IF ROOM IS AVAILABLE OR EXTERNALLY ON DRAW BARS OR BUMPER BARS, WHATEVER IS THE MOST PRACTICAL DELIVERY WE DELIVER PER AUSTRALIA POST, NORMAL OR EXPRESS, NORMAL DELIVERY IS 4-5 WORKING DAYS EXPRESS IS OVERNIGHT TO MAJOR TOWNS, COST VARIES FROM $40 TO $80 DEPENDING ON KIT TYPE AND POST CODE, IF YOU SUPPLY YOUR POSTCODE WE CAN QUOTE DELIVERY COST PLEASE NOTE THE HEATER UNIT ONLY USES ON HIGH.24 L /HOUR SO 10L WILL LAST 41.66 HOURS WE CAN CUSTOM BUILD YOU KIT FOR YOU CARAVAN, CAMPER TRAILER, SLIDE ON, MOTOR HOME, FIFTH WHEELER, CABIN, CAMPER VAN FOR MORE INFO CONTACT GRAEME 0418130971 WWW.DIESELHEAT.COM.AU DIESELHEATAUST@GMAIL.COM PLEASE NOTE ALL OUR KITS COME WITH FULL FITTING INSTRUCTIONS PLUS PHONE SUPPORT IF REQUIRED WE SERVICE WHAT WE SELL