Infrared Ceiling Mount Sensor

Similar documents
Infrared Ceiling Mount Sensor

Infrared Wall Mount Occupancy Sensor

Wireless Wall-Mount Sensor

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Installation Instructions

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Wireless Wall-Mount Sensor

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

DS160/161 Request To Exit PIR sensors Installation Instructions

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Wireless Wall-Mount Sensor

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

ViveTM Basic Packages

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Vive PowPak Fixture Controls

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

VESICA LINEAR SUSPENDED VES L

Sensors and Detectors

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Versatility. Maximum Energy Savings

Ever evolving energy code requirements and the large demand for energy

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Installation Instructions

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

Maestro 0 10 V Dimmer Sensor

Bryant Evolution Connex Control (SYSTXBBECC01-B) Occupancy Sensing Sequence of Operation

, ,

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

LPCMPIRM65 & LPCMPIRDSI65

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

FR-A180 FR-A360. Occupancy detector. Use

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

Installation Instructions

Document # R01

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Technical Application Guide

180 Degree Ceiling Mounted Occupancy Sensors

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

µdim Microwave Sensors User Manual

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Maestro Occupancy Sensor C L Dimmer

LPC3BSP65 & LPC3BDP65

360º Surface Mount Ceiling PIR Light Controller

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

D-Tect 2 GJD300 Quad PIR Movement Detector

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

EcoSystem H-Series 347 V~ Ballast Overview

Mini Product Guide.

LUX Hardwired - Installation Notes

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

UP 258E11 OPTISENS OFFICE

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

Maestro Occupancy Sensing Switch

Model #: RC3 Model #: RC3D Model #: RC3DE SAFETY INSTRUCTIONS

IP65 High Bay Dual Sense Sensor

Specifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950

English. Italiano. Português. Françias. Español

A. This Section includes the following lighting control devices:

Maestro Dual-Circuit Occupancy Sensing Switch

Integrated PIR detectors

60W Multi PIR Bulkhead

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

PMCSF6 OCCUPANCY SENSOR

Wireless High Bay Sensor (WHS100) Installation Instructions

Viewguard Motion detctors PIR and DUAL detectors

Commercial Series TriTech Motion Detector. Reference Guide

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

IP65 High Bay Dual Sense Sensor

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

D-TECT Dual Tech. GJD360 Triple Technology External Detector

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

MALAVIYA NATIONAL INSTITUTE OF TECHNOLOGY JAIPUR. No. F5(1587)ST/MNIT/Estate/2016 Phone : ,

A. This Section includes the following lighting control devices:

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Reduce lighting energy costs with controls

360 Surface Mount Ceiling PIR Light Controller

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

Transcription:

Infrared Ceiling Mount Sensor 69655c 0.07. The LOS-CIR Series passive infrared ceiling-mount sensors can integrate into LutronR systems or function as stand-alone controls using a LutronR power pack. The sensor uses a small semiconductor heat detector that resides behind a multi-zone optical lens. The detector is sensitive to the heat emitted by the human body. In order to trigger the sensor, the source of heat must move from one range of detection to another. Non-moving hot objects will not cause the lights to turn on. Features Intelligent, continually adapting Passive Infrared (PIR) sensor Passive Infrared (PIR) sensing Reliable motion detection with high error immunity Snap-locks to ceiling-mounted cover plate Non-Volatile Memory: settings saved in protected memory are not lost during power outages 50 ft( to 500 ft( ( m( to 0 m() coverage when mounted on an 8 ft to ft (. m to.7 m) ceiling Affords choice of turning lights off or dimming to a preset level in the unoccupied state when integrated with a LutronR system. Models Available Model Color Coverage Field of View LOS-CIR-50-WH White 50 ft( ( m() 60 LOS-CIR-500-WH White 500 ft( (0 m() 60 Self-Adaptive Feature The LOS-CIR Series sensors provide reliable detection with high error immunity. The internal microprocessor analyzes the information from the PIR technology and determines the optimum setting to use in order to properly cover the space.

Specifications 69655c 0.07. Regulatory Approvals ULR and culr listed Operating voltage: 0 V-, IEC PELV/NECR Class Operating current: ma nominal Control output: 0 V- active high logic control signal with short-circuit protection, open collector when unoccupied Environment Temperature: F to 0 F (0 C to 0 C) Relative humidity: less than 95%, non-condensing For indoor use only Timer Adjustment Automatic mode: Continually adapting sensor automatically adjusts settings to the space Manual mode: 8 to 0 minutes Test mode: 8 seconds LED Lamp : infrared motion detected Housing Rugged, high-impact, injection-molded plastic Color-coded leads 6 in (5 cm) Adaptive Functions Installation: 60 minutes Learning: weeks for response to error conditions, air current adaptation, and timer optimization Post-learning occupancy periods hour circadian occupancy periods learned Weekly occupancy periods learned Adjustments in post-learning period Generally occupied periods (threshold = high-sensitivity mode) Generally unoccupied periods (threshold = miser mode) Dimensions. in (8 mm).5 in ( mm) Front View Side View

Wiring: System Control 69655c 0.07. packs may be required when interfaced to LutronR lighting control systems. If more than occupancy sensor is connected to the same input, a power pack is required. A maximum of occupancy sensors can be connected to the same input. If more than sensors are required per input, use one of the following models: LOS-CDT-500R-WH, LOS-CDT-000R-WH, or LOS-CDT-000R-WH. Supply Options LutronR Lighting Control System Digital microwattt EcoSystemR Energi Savr NodeT GRAFIK 5000T/6000R/7000T GRAFIK EyeR 000/000 GRAFIK EyeR QS HomeWorksR HomeWorksR QS LCP8T microwattr QuantumR RadioRAR RadioRAR Softswitch8R Pack Required? No No No, when used with seetouchr wallstations with occupancy sensor connections. No, when used with seetouchr wallstations with occupancy sensor connections. No No, when used with seetouchr wallstations with occupancy sensor connections. * Some system components do not supply external power for occupancy sensors. Refer to individual product specifications for more information.

Wiring: Stand-Alone Control 69655c 0.07. to Sensors with Pack Line 0 / 77 / 7 V~ 60 Hz; 0 V~ 50 / 60 Hz Neutral (+0 V-) Blue (signal) (common) Pack White Lighting Load NOTE: Maximum occupancy sensors. Switching Multiple Loads with Auxiliary Packs Line 0 / 77 / 7 V~ 60 Hz 0 V~ 50 / 60 Hz Neutral Lighting Load Auxiliary Pack (+0 V-) Blue (signal) (common) Pack White Lighting Load NOTE: Maximum of devices total (occupancy sensors and auxiliary power packs) can be connected to a power pack.

Installation 69655c 5 0.07. Sensor Setup Sensor setup is available as a service by Lutron. For more information see the Sensor Layout and Tuning service document (LutronR P/N 605). Sensor Placement The occupancy sensor must have an unobstructed view of the room. Do not mount behind or near tall cabinets, shelves, indirect hanging fixtures, etc. Do not place sensor within ft (. m) of air vents, air handlers, windows, fans, etc., as this may cause false triggering. Closely follow the diagrams shown concerning major and minor motion coverage. The sensor can detect major motion (e.g. person taking a half-step) at a greater distance than it can detect minor motion (e.g. writing at a desk or reading a book). May not detect occupancy with no significant difference between ambient and body temperatures. Range Diagrams Major motion detection Minor motion detection 6.5 ft (.9 m) ft (.7 m) LOS-CIR-50 ft (.7 m) ft (6.7 m) LOS-CIR-500 5

Mounting 69655c 6 0.07. Normal Mounting Twist and lock threaded mounting post onto cover plate. Drill through ceiling tile with assembly, using cutter end of the threaded mounting post. Secure with washer and nut. Mounting to Non-Standard Ceiling or Fixture Mount twist-lock cover plate using mounting screws, nuts, and washers (included). Drill/punch wire routing hole through ceiling tile at center of cover plate. /6 in ( mm) Cutter end Mounting Plate Dimensions 0.5 in (. mm).5 in (6 mm). in (06.6 mm) Wire Lengths Number of Sensors Number of Auxiliary 0 0 0 Packs AWG 750 ft 75 ft 50 ft 75 ft 50 ft 50 ft 0.5 mm( 65 m 80 m 0 m 90 m 0 m 0 m 0 AWG 00 ft 600 ft 00 ft 600 ft 00 ft 00 ft 0.75 mm( 70 m 65 m 0 m 65 m 0 m 65 m 8 AWG 00 ft 00 ft 800 ft 00 ft 800 ft 800 ft Using the Infrared Mask Typical Mask Patterns Conference Room Mask 80 Mask Full Mask Center Ceiling Mount (Mask blocks sensor seeing out doorway into hall) Corner Ceiling Mount (No mask needed) Rectangular Areas Over the Door Specific Areas You Wish to Mask 6

69655c 7 0.07. Sensor Adjustments Override Settings Auto/Manual Threshold LED Motion Indicator Reset Learned Settings A Off (Default) Automatic (Normal) Auto Threshold Adjustment Lights indicate motion Retain Settings (Normal) On Manual on / off (Override) High Sensitivity (Low turn-on threshold) Disable LED Indicator Erase all learned settings; Restart Learning (Toggle On) OFF Strong Airflow Compensation Over Doorway Installation Timer Adjust Auto Sensitivity B Off (Default) Disable Compensation (Normal) No (Normal) Adjust Timer Automatically Adjust Sensitivity Automatically On Enable Compensation (Use increased turn-on threshold) Use Manual Setting (No adjustment) Adjust Sensitivity Manually OFF Timer Test Mode Factory Settings. Remove the retainer cover.. Rotate the black timer adjustment knob to about midway ( o clock).. Return setting to minimum setting (full CCW). : Infrared sensitivity 75% default A B Factory Settings o clock Full CCW : Timer 8 min NOTE: The timer will remain in the 8 second test mode for hour, then automatically reset to 8 minutes.. To manually take the timer out of the 8 second test mode, turn the timer adjustment approximately /6 in (.5 mm) clockwise to make the setting slightly above minimum (just above the 8 minute setting). 7